Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC SATYAPIRTALA CHINSURAH DIST HOOGHLY 712101 | CHINSURAH | HOOGHLY | WEST BENGAL | 712101 | L1 | Accepted-AOC LOWEST RATE QUOTED | |
| 2 | L2₹2.5 L+₹5,052.48 (2.04%)Rejected-Finance 14 NANILAL CHATTERJEE LANE RISHRA 712248 WEST BENGAL | RISHRA | HOOGHLY | WEST BENGAL | 712248 | L2 | Rejected-Finance HOGHEST RATE QUOTED | |
| 3 | L3₹2.5 L+₹7,356.78 (2.98%)Rejected-Finance BABUGANJ STRAND ROAD HOOGHLY 712103 | HOOGHLY | HOOGHLY | WEST BENGAL | 712103 | L3 | Rejected-Finance HOGHEST RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹4,000
Closing Date
4 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer_PWD_Hooghly_Electrical_Division
Office of The Executive Engineer, PWD, Hooghly Electrical Division , Purta Bhavan 3rd Floor , Sarat Sarani , Kodalia , Hooghly
Electrical Installation work for the proposed Indoor Game Facility Room at the Gurudeb Bhawan campus of Chandernagore College, Hooghly
2022_WBPWD_417055_1
WBPWD/EE/HED/NIeT-21/ 2022-23
Open Tender
Electrical Work/ Equipment
Item Rate
10 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,000
HOOGHLY ELECTRICAL DIVISION
21 Dec 2022
21 Oct 2022
7 Nov 2022
21 Oct 2022
4 Nov 2022
21 Oct 2022
28 Oct 2022
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average Run 8 Mtr [4(c)/ E-25 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board [3(i) / E- 20]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
2 module [2(a)/E-17]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
6 module [1(b)/E-17]
Supplying & Fixing modular type plug socket /switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required.
16 A modular type plug socket [4(b)/E-17]
16 A modular type switch [3(b)/E-17]
6 A 5-pin modular type plug socket [4(a)/E-17]
6 A modular type switch [3(a)/E-17]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes (in mm) flushed in wall & 3 mm thick bakellite cover as per GS.
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
200 x 150 x 65 [11(d)/E-4 ,13(d)/E-5]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens Enclosure (8GB32102RC14) / Schneider Enclosure-(A9HSND12) or equivalent model of Legrand / L&T/ Crabtree] as per direction of EIC. [ 13 / D- 9 & D-10 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/Schneider/Siemens/ Crabtree/ L&T as per direction of EIC.]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing 240V, 32A DP Sheet steel Main Switch on flat/angle iron frame on wall as per GS. [1(a)/D-1] (Make - L&T / Siemens / Havells)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
Supply & fixing of 240V, 50Hz Analog Time Switch (Make- L&T GIC, Cat No. J648B1 or equivalent make/model of Havells/Hager) in existing 4 way SS enclosure for controlling of exhaust fan as per direction of EIC.
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [Make- Gloster / KEI / Havells/ RR Kabel]
2 Core 16 Sq.mm
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. [3(a)/ F-1]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [2(a)/F-1]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 16 Sq.mm [7(a)/F4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 16 Sq. mm [8(b- iv) /F5]
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings as per GS
40mm dia [11(c)/F-6]
Supply of 36 W Recessed mounted 2' x 2' LED light fittings having 120lm/Watt and CCT- 6500K with glare-free uniform illumination. (Make- Magik- Aculux, Cat No.- PCAC036C or equivalent model/cat of Phillips / CG/ Wipro as approved by EIC) (with 3 years warranty and warranty certificate to be provided)
Fixing of square recessed mounted LED fittings after cutting of false ceiling / matching & finishing the same incl. necessary connection as per direction of E.I.C.
Supply of 450mm sweep wall bracket fan(high speed) with metal body & blades (Make- Orient - Wall-II Tornado or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc. (with 2 years warranty and warranty certificate to be provided)
Supply of heavy duty Exhaust fans of following size complete with all accessories (Make- EPC) as per direction of EIC.
9"( 230mm ) Speed 1370 RPM
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [29/C-4]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS.
Supply & Fixing of 240V, 45 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Make- Magik-Solis Plus, Cat No.- SPSP045C or equivalent model of Philips/Wipro/CG as approved by EIC) on existing MS Pipe/Mini Pole/Long Pole as per direction of E.I.C. (with 5 years warranty and warranty certificate to be provided)
Fixing only outdoor/street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [18/C-3]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming for Soft Soil. [1(a)/G-1]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5(c)/G-3]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Add GST @18% Rs.
Add LWC @1% except item no.- 17, 24, 26 & 27 Rs.
SANDIP TRADERS
D. D. ENTERPRISE
technical_822264.pdf
PDF • 0.32 MB
techsummary_822264.pdf
PDF • 0.60 MB
finance_822264.pdf
PDF • 0.48 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_822264.pdf
PDF • 0.71 MB
NIT21-22-23.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .