Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.7 L+₹7.2 L (25.1%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L2 | Rejected-Finance Being 2nd lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF ONE ADDN INFRASTRUCTURE /LAB IN PM SHRI KV AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2024_MES_664755_1
8124/SAR-T-09/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE(AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) SARSAWA
₹66,000
Yes
4 Oct 2024
9 Jul 2024
19 Sept 2024
9 Jul 2024
12 Sept 2024
30 Jul 2024
9 Jul 2024 - 30 Jul 2024
Amount
Surface dressing not exc 15cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge. Note : Removing of vegetation / shrubs / brushwood / undergrowth and carrying away rubbish to a distance of 50 m deemed to included in quoted rate.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes etc not exc 10Sqm on plan and not exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Earth filling under floors including spreading, leveling, watering and well ramming in each layers not exc 25 cm thick complete all as specified and directed. Note :- Soil obtained from excavation under item 2.00 here-in-before shall be used for filling.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for form work to sides of Pillars, posts, struts piers, columns etc in square, rectangular or polygonal, rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork to chajjas,shelf, chullah hoods, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams,plinth beams, bases for columns, mass concrete and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design Mix) using 20mm graded stone aggregate in lintels upto 1.5m clear span, seismic and other similar bands, lintel bands and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in columns, pillars, piers, posts, struts and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in chajjas, shelf and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No.18 above but 5mm dia and over up to & including 10mm dia in stirrups, spacers & binders.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 all as specified & directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls including finishing the surface fair and even complete all as specified.
M&L for rendering 10mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick work of walls including finishing the surface fair and even complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for providing cement concrete in type B0 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to (consolidated thickness 65mm or less) as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified& directed by Engr-in-Charge.
M&L for 15mm thick plaster over top of roof slab/chajjas in CM 1:4 mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement all as directed. Note : - Supply only water proofing admixture shall be measured and paid for separately.
Supply only integral liquid water proofing compound
M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces completed all as specified and directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate), as in sub base all as directed by Engineer-in-charge.
M&L Vetrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.42 sqm, but not 1.00 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick cement screeding in CM 1:6 Complete all as specified and directed by Engr-in-Charge.
M&L Vitrified Ceramic tiles 10mm thick double charged (square/rectangular) polished, area of each tiles exceeding 0.42 sqm, but not 1.00 sqm, in vertical surfaces as skirting and dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 10mm thick rendering in CM 1:4 Complete all as specified and directed by Engr-in-Charge.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types and over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge Note : Glazing/panelling measured and paid saperately in respective items.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed. Note : Glazing/penelling measured and paid saperately in respective items.
S&F factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified and directed.
S&F anodized aluminium door shutters, aluminium section weighing 0.55 kg/m, with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed.
Supply only 5mm thick Tinted Coloured glass fixed to metal frame complete all as specified and directed.
S&F anodized aluminium grill with power coating (minimum thickness 50 micron) of approved pattern and fixed to the existing window/ventilator frame with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed by Engr-in-Charge.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples & scrwed complete all as specified and directed
Supply and fixing stainless steel hinges 100mm long medium weight to pressed steel/angle iron frames by welding/screws all as specified.
S&F aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed
S&F extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked.
S&F 300 mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, ISI marked complete all as specified.
S&F 25mm dia curtain rod,stainless steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
S&F galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
S&F galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F door closer hydraulically regulated, designation No. 2, aluminium (Die cast) body, universal type (ISI marked) suitable for door shutters of 701 to 850mm in width and weight between 36 to 60 Kg and fixed complete all as specified & as directed.
S&F PVC connection 600 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F 15mm bore stop / angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F 15 mm bore bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed
S&F Pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified
S&F 32mm dia Brass chromium plated bottle traps for wash basins/urinals with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed Complete all as specified
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal with access door complete all as specified.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) floor trap plain with PTMT grating including jointing with solvent cement, diameter of outlet 100mm, complete.
S&F vitreous china counter top basin size 450 x 525 x 195 mm shape oval of Jaquar or equivalent of PARRYWARE / MARC / KINGSTON / SOMANY / ESS ESS / SIECO / KOHLER / HINDWARE / PRAYAG / PARKO including 32 mm CP waste coupling complete all as specified & directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor.
M & L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
S/F Stainless steel kitchen sink, single bowl handmade kitchen sink with multi-functional and silver 1mm thick (weight not less 6kg ) with plugs, washers and waste pipe including bedding in cement mortar or including and fixing cast iron cantilever brackets and connecting union to pipe bowl size 600x450x250 mm including flush pipe of polyethylene of low or high density or PVC 32mm bore with long screwed shanks and fly nuts complete all as specified & directed by Engr-in-Charge.
M&L for preparation of newly plastered/unplastered surfaces of ceilings & applying two coats of oil bound distemper (OBD) complete all as specified..
M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemper over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
Material and labour for preparation of new plastered surfaces and applying two coat exterior emulsion paint over a coat of primer paint complete all as specified and as directed any tint.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified.
Providing and laying prepolished cement concrete Chequered tiles 30cmx30cmx25mm thick, with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape heavy duty , set,jointed and pointed in neat cement slurry in floors over screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge.
M & L for concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :- One light / fan point controlled by one way switch
All as per above item No-75 here in before but One 5 Amp socket outlet on independent board.
All as per above item No-75 here in before but One 5 Amp socket outlet on same board.
All as per above item No-75 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
S&F socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed.
S&F in socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in switch 6 amps modular type one one way complete all as directed.
S&F in switch 16 amps modular type one one way complete all as directed.
S & F in of modular Fan Regulator fan step regulator,120W- single module ISI Marked complete all as specified as as directed.
S&F of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 2.5 sqmm (Nominal area) drawn in and including concealed PVC conduit of suitable size as directed with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be of same.
S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 6 ways 240 V including connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be of same.
S&F in of Double door distribution board 4 way TPN when MCB to be used as incomer powder coated with Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, complete all as specified and directed (Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.)
S&F MCB SP 5 to 40 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F MCB TPN 63 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply and fixing Earthing to DBs with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
S&F enviroment friendly indoor decorative 20 Watt LED Aluminium Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for laying cable complete all as specified and directed by Engineer-in-Charge.
Material & labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Material and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge.
Supplying, laying, jointing , testing and commisssioning underground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volt grade with size of 35 Sqmm 3.5 core confirming to IS: 7098 part-I ammended upto date, laid in trenches, along pole/wall/across road etc as per site condition .Note:- Exacavation/Earth work , brick & sand protection shall be measured and paid saperately.
Labour for augering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI wire 4 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate No. 3 of MES Schedule Part-I (1991) & including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 15 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE :(i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ (ii) On testing if the desired earth resistance is not obtained i.e, less than 5 ohm then earthing will be regenerated at no extra cost till the desired earth resistance is obtained
Supply, installation, testing & commissioning floor mounted LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, 8Minimum IP43 degree of protection to be proided as per IS 12063-1987 / IEC 60529.including all accessories like lamps, push buttons, interlocks, CT, PT, Meters . Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthing bus bar and stud with plate to be provided both side of LT Panel. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm). Incoming:Aluminium busbar 4 pole of rating 100 Amps - 01 set (a) MCCB 4 Pole 16 KA 63 Amp, adjustable type with spreader link - 01 Nos (b) Digital type Amp meter & voltmeter , 3 phase with CT- 01 set (c ) LED indicating lamp three Nos (RYB)-01 set Outgoing:-(a) MCCB , 4 pole , 10 KA, 40 A, adjustable type with spreader link- 02 Nos.
M&L for GI pipe light grade of size 40 mm bore with all fittings such as socket, union etc complete all as specified and directed.
Supply, install, testing and commissioning of energy efficient dual inverter type split type air conditioner unit 1.5 TR capacity alongwith copper condensor coil , indoor/outdoor unit suitable for working on 230 volts, 50 Hz complete with cordless remote control unit using green gas refrigerant and with inbuilt anti dust for better indoor air quality having memory function , dry mode , auto mode , on/off timer in remote with 5 star rating include cutting the holes and making good the surface with existing colour complete all as specified and directed by Engr-in-charge. Note:- Cost of iron stand for fixing outdoor unit and copper tubing along with insulation for connecting indoor and outdoor unit is included in quoted rate.
S & F single pole and neutral encloser with a two pin and earth plug and socket complete with one single pole MCB 20 A, 240 volt, 10 KA, C curve complete all as specified and directed.
Supply and fix Automatic voltage stabliser 4 KVA , ISI marked digital wall mount , input voltage 160-260 V, Rated output voltage 195-245 , rated currentb14.5 amp , insulation class B suitable for 1.5 ton air conditioner with inbuilt electronic over load trip , protection against high/ low voltage & timer for 10 seconds , efficiency more than 97% complete all as specified and as directed.
S & F wiring for circuit / submain wiring alongwith earth wire with 2x4.0 sq. mm + 1x4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor unsheathed in PVC conduit , single core cable in surface / recessed as required complete all as specified and directed.
RADHA ENTERPRISES (BID ID -3076614)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .