Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 3B CHANDRALOK APARTMENT 3RD FLOOR KUTCHERY ROAD RANCHI JHARKHAND PIN 834001 | RANCHI | JHARKHAND | 834001 | L1 | Accepted-AOC MS Associated Buildcon is lowest and accepted | |
| 2 | L2₹28.3 L+₹67,426 (2.44%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.8 L+₹3.2 L (11.6%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹31.8 L+₹4.2 L (15.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹36.8 L+₹9.2 L (33.2%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹40.8 L
EMD Value
₹81,600
Closing Date
4 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Y K Gour
HQ CWE Ranchi, MES, Dipatoli Cantt
PROVN OF UG HT 11 KV CABLE ALONGWITH CONNECTED ITEMS TO JCOs ORs MD ACCN AT BIRSA MUNDA LINES AT KHOJATOLI AREA POWER HOUSE UNDER GE RANCHI
2024_MES_640603_1
80599/1498/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Ranchi
Refer as per tender documents
6 documents required · 6 mandatory
₹500
GE Ranchi
₹81,600
Yes
HQ CWE Ranchi
30 Mar 2024
5 Feb 2024
12 Mar 2024
5 Feb 2024
4 Mar 2024
19 Feb 2024
5 Feb 2024 - 10 Feb 2024
10 Feb 2024
Amount
Supply, installation, connection, testing and commissioning of outdoor type 11 KV SF6 insulated, 630 Amps rupturing capacity upto 250 MVA, extensible outdoor fixed type (IP67), RMU (Ring maint unit) with one incomming load breaking switch and one outgoing VCB with manual operated vacuum circuit Breaker having digital type overload and earthfault protection, ammeter, inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having minimum thickness 2.5+0.5 mm having IP 67 Degree of protection RMU should be provided with internal busbars, as well as earthing. Busbars should be of copper, padlock provisions & complete with all accessories. The RMU shall be type tested for internal arc test of not less than 21KA/1 sec as per IEC62271-200. RMU shall be equipped with site replaceable bushing. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP 54 protection complete all as specified and as directed. (a) Vaccum circuite Breaker module should consist of following accessories: (i) 630 Amps Vacuum Breaker module for making and breaking of fault current alongwith Earth Switch of full making capacity. VCB should be capable to bear 40 dead short circuit operation. (ii) Short time current - not less than 21 KA 1 Sec (iii) Making Capacity 50 KA (iv) Auxiliary contacts - 1NO + 1NC (v) Power frequency withstand voltage - 28 KV (vi) Impulse withstand voltage - 75Kv (vii) Nominal operating gas pressure - 1.3 (minimum) Bar abs. (viii) front cover mechanism - IP 2X (ix) Cable box for front termination for the cable suitable upto 3 core 95 Sqmm, 11 KV XLPE cable
(x) Right angle boots (push on type) (xi) Self Powered Microprocessor based Relay (3 O/C & E/F) with standard settings (xii) Digital ampear meter with RYB (xiii) Suitable site replaceable Cable bushings (xiv) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector & VCB (xv) Capacitive voltage indication fixed type system (xvi) Mechanical indications for breaker ON, OFF, Earth, TRIP, Spring Charged-Discharged. (b) RMU will include following also:- (i) Microprocessor based IDMT (50, 50N, 51, 51N) relay for overcurrent, short circuit and earth fault protection- 01 Nos. (ii) RYB phase indications for 1 incoming (Load Breaking Switch) and 1 out going (Compact fixed type VCB)- 2 sets. (iii) Cable support bus bars, standard for 2 way unit-01 Nos. (iv) Bushings for external busbar connection along with Busbar cover & Sleeved busbars for coupling- 01 set. (v) Necessary interlocking arrangement for safety and operations (vi) Operation Handle for Manual Operation- 01 Nos. (vii) Manometer- 1 Nos. (viii) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (ix) Above Switchgear shall confirm to all relevant IEC/IS Standards. (x) Manual operation of Vacuum Circuit Breaker.
(xi) Coupling of RMU and metering module shall be with the help of bolted type arrangement, so that the coupling at site shall be easy. Plug-in-type bushing shall not be acceptable. (xii) All cable bushing shall be replaceable type. (xiii) Module shall be accommodated as per manufacture's design. (xiv) RMU cable box shall be front accessible type to have easy access to protection and metering CTs. Vacuum Interupter shall be of same make. Cable box shall be arc proof with bolted door and interlocked with respective earthing switches. Doors shall be removable for the ease access to terminate cables. (xv) Any other item not mentioned above but required for proper functioning of RMU shall be provided and deemed to be included in quoted rate. Note:- (i) RMU shall be installed on suitable PCC foundation as per manufactures drawing. (ii) Cost of PCC /Earth work deemed to be included in the rate quoted. (iii) The contractor shall submit the NABL Accredited lab test reports of the RMU's in original and the same shall be produced well before claiming RAR payment of the RMU. (iv) Pre-despatch inspection shall be carried out by Rep of Accepting Officer. All arrangement for the same shall be arranged by the contractor & shall be considered within quoted rates. (v) Design, drawing of RMU to be submitted by the contractor for approval from the Garrison Engineer prior to manufacturing.
Earthing complete including taking down of old one with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No-3 of SSR- Part-1 connected to earth strip all as specifed or indicated including testing on completion and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm meduim grade watering pipe, 40 mm GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and directed.
Supply laying testing and commissioning XLPE insulated screened, PVC badded galvanized steel strip on wire armoured, electric, power cables (heavy duty) with aluminium conductor 11KV/6.6 KV, earthed system cross sectional area 95 Sq mm X 3 core laid in trenches or passing through pipe or fixed to poles complete all as directed.
S & F Cable joint kit for 11 KV(earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and acessories suitable for 03 core XLPE armored aluminium conductor cable of size 95 sq mm complete all as directed.
S & F Cable joint kit for 11 KV(earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and acessories suitable for 03 core XLPE armored aluminium conductor cable of size 95 sq mm complete all as directed.
Mannual excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for laying under ground cables/erection of pole and getting out in hard/dense soil, complete all as directed.
Mannual excavation in trenches n. exc 1.5 m wide & n. exc 1.5 m in depth for laying under ground cables/erection of pole and getting out in hard rock/ road complete all as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as directed.
Removal of excavated surplus material (Soil) to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as directed.
Sand filling in cable trenches for cable protection with clean dry sand unwashed including gently put in trences.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 flat size300mmX180mmX40mm complete all as directed.
S & F GI pipe light grade100 mm dia as protection to cable along the pole / across road crossing/through culvert/passing through ceiling/walls with necessary clamps-02 nos(Flat iron 50x6mm) with ,nuts and bolts complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, floors etc complete all as directed.
S & F cable route indicator/Marker made up of PCC block in PCC 1:2:3 (using 20mm graded aggregate) of size 900x300x100mm thick with Danger/11 KV cable/MES embossing on route indicator/Marker and painting as per approved colour and buried in ground 45 cm depth including pot hole of 450x400x200mm and PCC 1:4:8 ( using 20mm graded aggregate) for grouting complete all as directed.
Raj Construction
arics infrastructure
M/S Akash Enterprises
B.K. ROY & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .