Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 CrAccepted-AOC MILAN NAGAR DIBRUGARH ASSAM PIN 786003 | DIBRUGARH | ASSAM | 786003 | ₹8.8 Cr | L1 | Accepted-AOC As per tender conditions |
| 2 | L2₹12.4 Cr+₹3.6 Cr (40.4%)Rejected-AOC BADRI RAI COMPANY ARUN KUMAR RAI DULIAJAN STATION ROAD P O DULIAJAN P S DULIAJAN DIBRUGARH PIN 786602 | DULIAJAN | DIBRUGARH | ASSAM | 786602 | ₹12.4 Cr+₹3.6 Cr (40.4%) | L2 | Rejected-AOC As per tender conditions |
Tender Value
Refer Docs
EMD Value
₹20 L
Closing Date
14 Sept 2023, 2:30 pmClosed
BHASKAR J. BARMAN
Brahmaputra Cracker and Polymer Limited, C and P Department, Administrative Building, PO_Lepetkata, Dist_DIBRUGARH, Assam, Pin Code_786006
Please refer Tender documents.
2023_BCPL_165270_1
BCPL/CNP/LE23W059BB/02767
Open Tender
Civil Works - Buildings
Works
540 days
BCPL, Lepetkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹20 L
Yes
BCPL, Lepetkata
3 Jan 2024
22 Aug 2023
15 Sept 2023
22 Aug 2023
14 Sept 2023
22 Aug 2023
30 Aug 2023
Amount
Short Text : Earth work in excavation by mechanical m Long Text : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.:All kinds of soil
Short Text : Earth work in excavation by mechanical m Long Text : Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.: All kinds of soil.
Short Text : Excavating trenches of required width fo Long Text : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for all kinds of soil:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Short Text : Filling available excavated earth (exclu Long Text : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Short Text : Filling local earth Long Text : Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth <(>,<)> sides of foundation etc. complete.
Short Text : Extra for every additional lift of 1.5 m Long Text : Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials:All kinds of soil
Short Text : Sand filling in plinth Long Text : Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Short Text : Plinth protection 50mm thick Long Text : Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Short Text : Cement concrete (1:5:10): upto plinth Long Text : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
Short Text : Cement concrete (1:5:10): above plinth Long Text : Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
Short Text : Waterproofing material in concrete Long Text : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Short Text : RCC upto plinth: 1:2:4 Long Text : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
Short Text : Centering and shuttering : foundation Long Text : Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Short Text : Centering and shuttering : Suspended flo Long Text : Suspended floors, roofs, landings, balconies and access platform
Short Text : Centering and shuttering : Shelves (Cast Long Text : Shelves (Cast in situ)
Short Text : Centering and shuttering : Lintels Long Text : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Short Text : Centering and shuttering : Columns Long Text : Columns, Pillars, Piers, Abutments, Posts and Struts
Short Text : Centering and shuttering : Stairs Long Text : Stairs, (excluding landings) except spiral-staircases
Short Text : Centering and shuttering : Edges of slab Long Text : Edges of slabs and breaks in floors and walls:Under 20 cm wide
Short Text : Centering and shuttering :Chajjas Long Text : Weather shade, Chajjas, corbels etc., including edges
Short Text : Extra for additional height in shutterin Long Text : Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Short Text : Design mix concrete-M30 upto plinth Long Text : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement (PPC) content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.: All works upto plinth level
Short Text : Steel reinforcement - upto plinth Long Text : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Short Text : Steel reinforcement - above plinth Long Text : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Short Text : Plastering drip course/ groove Long Text : Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Short Text : Design mix concrete-M30 above plinth Long Text : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement (PPC) content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.: All works above plinth level upto floor V level
Short Text : Add for using extra cement in the items Long Text : Add for using extra cement in the items of design mix over and above the specified cement content therein.
Short Text : Brick work (1:6) upto plinth Long Text : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Short Text : Brick work (1:6) above plinth Long Text : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Short Text : Half brick masonry (1:4) Long Text : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level: Cement mortar 1:4 (1 cement :4 coarse sand)
Short Text : Granite cladding/ platforms:18 mm thick Long Text : Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade: Area of slab over 0.50 sqm
Short Text : Ceramic wall tiles in dao, skirting etc. Long Text : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of minimum size 300x600 mm or as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.Size should not be less than 300x600 mm.
Short Text : Clay/Terracotta ventilated rainscreen ti Long Text : Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 250/ 300/ 400mm and length of 595 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework(Alloy 6063 T5/T6) consisting of vertical 'T' (for intermediates)/ 'L'(for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 600mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x25x2mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self-drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns)of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal ‘C’ clamps using special SS clips of required size which shall be inserted and pressed into position on the ‘C’ clamps holding the tiles and the cut-tiles shall be glued at points to the horizontal ‘C’ clamps by using MS Polymer sealant adhesive. The vertical joint open groove between two adjacent tiles shall be 5mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge. Note : Scaffolding wherever required to be paid separately:With 16mm thickness (+/- 10%) terracotta tiles of other than grey colors
Short Text : Structural Glazing Long Text : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T<(>&<)>P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Short Text : Powder coated aluminium frames for fixed Long Text : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron)
Short Text : CP brass cupboard knobs Long Text : Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete.
Short Text : Extra for providing frosted glass panes Long Text : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Short Text : Flush door shuter: 35 mm Long Text : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Short Text : CP brass cupboard locks Long Text : Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete: Size 50 mm
Short Text : Aluminium sliding door bolts: 300 x 16 m Long Text : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
Short Text : Aluminium sliding door bolts: 250 x 16 m Long Text : Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
Short Text : Aluminiumtower bolts: 250 x 10 mm Long Text : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
Short Text : Aluminiumtower bolts: 150 x 10 mm Long Text : Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm
Short Text : Aluminium handles-anodized: 125mm Long Text : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Short Text : Door stopper: Twin rubber Long Text : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete: Twin rubber stopper
Short Text : Magnetic catcher: double strip Long Text : Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete: Double strip (horizontal type)
Short Text : Two track two panels sliding window made Long Text : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made:Two track two panels sliding window made of (small series) frame 52 x 44 mm <(>&<)>sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Short Text : Three track three panels sliding window Long Text : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge: Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Short Text : Steel roller for uPVC sliding window Long Text : Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete.
Short Text : Fly proof wire gauze of uPVC windows Long Text : Providing & fixing fly proof wire gauze to uPVC windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete:Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Short Text : T-iron frames for door/window/ventilator Long Text : Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Short Text : Pressed steel door frames Long Text : Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: [Profile C] Fixing with adjustable lugs with split end tail to each jamb
Short Text : Steel work in built section Long Text : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete: Hot finished welded type tubes
Short Text : M.S. fan clamp Long Text : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Short Text : MS sheet box for ceiling fan clamp Long Text : Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Short Text : Steel work built up sections in grating Long Text : Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required :In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Short Text : SS railing Long Text : Providing and fixing factory made stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Short Text : Providing & fixing glass panes Long Text : Providing & fixing glass panes with putty and glazing clips in uPVC doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Short Text : 52 mm thick hardened concrete flooring Long Text : 52 mm thick cement concrete flooring with concrete hardener topping<(> ,<)> under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Short Text : Vitrified tiles flooring: 600 x 600mm Long Text : Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size : Size of Tile 600 x 600 mm
Short Text : Double charge vitrified tile flooring:12 Long Text : Providing and laying double charge vitrified floor tiles of size 600x600 mm (DGVT) (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Double charge vitrified tile polished finish of size
Short Text : Granite flooring Long Text : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Short Text : Phenol bonded bamboowood flooring Long Text : Providing & fixing in position Phenol bonded Bamboowood flooring with planks of sizes 14mm thick, minimum 1800mm length andminimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducer of size 1900mm x 44mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.:
Short Text : Second class deodar wood flooring Long Text : 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with :Second class deodar wood
Short Text : UPVC rainwater pipes Long Text : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes: 110 mm diameter
Short Text : uPVC Coupler 110 mm Long Text : Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion:Coupler 110mm
Short Text : Door Bend 87.5° Long Text : Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion: Door Bend 87.5° 110 mm
Short Text : 110 mm Shoe (plain) Long Text : Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion:110 mm Shoe
Short Text : Water thinnable cement primer Long Text : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Short Text : Unplasticised -PVC clips 110 mm Long Text : Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete:110 mm
Short Text : Aluminium alloy roofing sheets Long Text : Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T<(>&<)>P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
Short Text : 12 mm cement plaster (1:6) Long Text : 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Short Text : 15 mm cement plaster (1:6) Long Text : 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Short Text : 6 mm cement plaster (1:3) Long Text : 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Short Text : Ready mixed pink or Grey primer Long Text : Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Short Text : Painting with synthetic enamel paint Long Text : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Short Text : White cement based putty Long Text : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Short Text : Wall painting: acrylic emulsion paint Long Text : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.: Two coats
Short Text : 15mm thk False ceiling-calcium silicate Long Text : Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 <(>&<)>7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.: With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles
Short Text : Subgrade preparation Long Text : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the subgrade and disposal of surplus earthwith lead upto 50 metres.
Short Text : 60mm thick paver block Long Text : Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Short Text : kerb stone of M-25 grade cement concrete Long Text : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Short Text : Eater closet pan (European type) Long Text : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Short Text : White Vitreous China Flat back wash basi Long Text : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Short Text : White vitreous china pedestal for wash b Long Text : Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Short Text : Providing and fixing PTMT shelf Long Text : Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms.
Short Text : Stainless Steel kitchen sink Long Text : Providing and fixing factory made Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Short Text : P.V.C. flexible waste pipe Long Text : Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe: 32mm dia
Short Text : Providing and fixing mirror Long Text : Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
Short Text : CPVC pipes exposed to wall: 20mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 20 mm nominal outer dia Pipes
Short Text : CPVC pipes exposed to wall: 25 mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 25 mm nominal outer dia Pipes
Short Text : CPVC pipes exposed to wall: 40 mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 40 mm nominal outer dia Pipes
Short Text : Concealed CPVC pipes: 15mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.: 15 mm nominal dia Pipes
Short Text : Concealed CPVC pipes: 20 mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.: 20 mm nominal dia Pipes
Short Text : CPVC pipes exposed to wall: 50 mm Long Text : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge: 50 mm nominal outer dia Pipes
Short Text : G.I. connection with main and distributi Long Text : Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
Short Text : Gun metal gate valve: 20mm NB Long Text : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Short Text : Gun metal gate valve: 40mm NB Long Text : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Short Text : Gun metal gate valve: 50mm NB Long Text : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
Short Text : Ball valve (brass): 20 mm NB Long Text : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Short Text : G.I. Union: 40mm NB Long Text : Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal bore
Short Text : Uplasticised PVC connection pipe Long Text : Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length and 15 mm nominal bore
Short Text : Sand filling around GI pipe Long Text : Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50 mm diameter pipe
Short Text : G.I. Union: 20mm NB Long Text : Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20 mm nominal bore
Short Text : G.I. Union: 50mm NB Long Text : Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50 mm nominal bore
Short Text : Water storage tank Long Text : Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Short Text : C.P. brass bib cock : 15mm NB Long Text : Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
Short Text : C.P. brass bib cock long body : 15mm NB Long Text : Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms:15 mm nominal bore
Short Text : C.P. brass stop cock (concealed): 15mm N Long Text : Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Short Text : SW gully trap: 100 x 100 mm Long Text : Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Short Text : NP2 class RCC pipes 150mm dia Long Text : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Short Text : Brick masonary manhole Long Text : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Short Text : Extra depth for brick masonary manholes Long Text : Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5:Size 90x80 cm
Short Text : Waterproofing: Polyurethane Long Text : Supplying and applying high build elastomeric waterproofing coating based on pure, htdrophobic polyurethane/poly urea, cold applied of spray/brush applied membrane of approved make with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3 mm as per ASTM C1305, no leakage upto 7 barsof water pressure as per DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying smartcare PU magnum or approved equivalent in two coats with a consumption of 1 kg per sqm on a primed surface with smartcare primer etc., complete as per manufacturers specification
Short Text : Waterproofing: Polymer modified cementat Long Text : Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Short Text : WPC flush door: 35 mm thick Long Text : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately):35 mm thick
Short Text : WPC door window frames: 45 x 70 mm Long Text : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made::Frame size 45 x 70 mm
Short Text : WPC door window frames:65 x 100 mm Long Text : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made::Frame size 65 x 100 mm
Short Text : WPC flush door: 30mm thick Long Text : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately):30 mm thick
Short Text : Waterproofing - Brushbond or equivalent Long Text : Providing and laying water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Providing and laying 6 mm thick(1 cement :3 sand) cement plaster including water proofing compound (1 kg per 50 kg of cement) as per direction of Engineer-in-charge. (b) Providing and applying two coats of Brushbond RFX/HS Latex Shield 2K or equivalent of acrylic polymer modified cementations water proof coating, Brushbond RFX shall contain a liquid polymer component and a cementations powder component, which shall be mixed as per manufacturer's instructions and applied over concrete surface strictly maintaining the coverage specified by manufacturer. The applied materials of Brushbond RFX should have a weight not less than 1 gm when tested abrasian resistance according to ASTM-D4060. pull off adhesion of greater than 1 N/mm2 as per ASTM-D4541 and static crack accommodation of 1 mm according to ASTM-C836. Strictly following instructions as per Fosroc specifications and as per direction of Engineer-in-charge. (c) Providing and laying 40 mm thick grading of cement concrete (1cement:2 sand :4 stone aggregate) ( 10 mm & down stone aggregate) including water proofing compound( 1 kg per 50 kg of cement) & finish the top surface with laying glass fibre cloth of approved quality in top smooth with making pattern of groove 300x300 mm as per direction of Engineer-in-charge.
Short Text : S.W.R. pipe - 110mm dia. Long Text : Providing and fixing in position S.W.R. PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 including jointing with Adhesive of approved make. The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqm) .The work shall be carried out as per manufaturer specification and as per direction of Engineer-incharge. (i) Single Socketed pipe:110 mm dia pipe
Short Text : PVC door bend 87.5 degree Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592, suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge: Bend 87.5° with door 110mm diameter
Short Text : PVC bend 87.5 degree (without door) Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge: Bend 87.5° without door 110mm diameter
Short Text : PVC door tee - 110mm dia Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge: 110 mm dia single Tee with door
Short Text : PVC tee - 110mm dia (without door ) Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge: 110 mm dia single Tee without door
Short Text : PVC coupler 110 mm dia. Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge.: Coupler 110 mm
Short Text : PVC Pipe Clamp with rubber seal - 110 mm Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge.:Pipe Clamp with rubber seal for 110 mm dia pipe
Short Text : Terminal guard / Vent Cowel 110 mm dia Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge.: Terminal guard / Vent Cowel 110 mm diameter
Short Text : PVC floor trap 110 x 90mm Long Text : Providing and fixing in position PVC moulded fittings/ accessories for SWR PVC pipe (working presure 6 kg/sqcm) conforming to IS: 13592 , suitable for use in sanitary system including jointing with Adhesive and rubber seal ring of approved make.The item is inclusive of the rate of rubber seal ring (working presure 6 kg/sqcm) .The work shall be carried out as per manufacturer specification and as per direction of Engineer-incharge: Floor -Trap 110 x 90 mm
Short Text : C.P Overhead shower 15mm inlet Long Text : Providing and fixing C.PJaquar Overhead Shower 200x200mm square single flow chrome with arm as per direction of engineer in charge - 15 mm inlet
Short Text : CP brass two way bib cock Long Text : Providing and fixing CP brass two way bib cock of Jaguar make continental series or equivallent approved quality :
Short Text : Towel rail 600mm long Long Text : Providing and fixing single towel rail 600 mm long of Jaquar make Cat No. ACN-CHR-1111SM complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour or equivalent range as appropved by engineer in charge.
Short Text : SS curtain rods:25 mm dia Long Text : Providing and fixing Stainless steel curtain rods (SS202) (Weight 350 gm/m) with two nos Stainless Steel brackets 25mm dia (Medium) i/c SS support fixed with stainless steel screws and PVC sleeves etc., wherever necessary complete : 25 mm dia
Short Text : C.P brass Health Faucet Long Text : Providing and fixing C.P brass Health Faucet of standard designed of Jaquar make as per direction of engineer-in-charge: 15 mm inlet
Short Text : Internal electric installations Long Text : Internal electric installations with light (LED ceiling light/ bracket lights, decorative lights) and fan fixtures (wall hanging, exhaust fan) as per drawing or as directed by EIC
Short Text : Power wiring and plug Long Text : Power wiring and plug including MS boxes, conduits,modular switch , sockets as per as per drawing or as directed by EIC
Short Text : Lightning conductors Long Text : Ligtning conductors as per drawing or as directed by EIC
Short Text : Telephone conduits Long Text : Telephone conduits and connections as per drawing or as directed by EIC
Short Text : Acoustic treatment- pinewood slats Long Text : Supply & installation of Anutone Salon Slats Surco or equivalent made of pinewood E1 grade fiberboard, melamine laminated finish, groove perforated slats L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centers), backlined with Soundtexblack acoustical fleece, tongue-groove edge for a seamless look, 1-test fire retardant grade, size 128x2440x16mm, volume density of base board 700Kg/m3, weight 8Kgs/m2 (L16), 10.5Kgs/m2 (L32) installed by using Anutone Strut framework system.Anutone Strut framework system includes Anutone Strut CC22 aluminium core cross channel having thickness 0.55mm, length 3600mm, knurled web 40mm, depth 22mm and equal flanges 15mm is fastened to wall or framework behind vertically/horizontally at every 600mm c/c. Anutone Strut CC18 aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge <(>&<)>centre brackets is then fixed perpendicular to the Strut CC22 Cross channel with the help of fasteners at every 400mm centers. Slats Surco of size 128x 2440x16mm in then fixed perpendicular to CC18 with suitable edge & centre brackets. Short edges of the panel are staggered. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise.Panels are backlined with Anutone SynthPF 5x25 held in position with dab spots of Anutone Stick S7Technical Parameters • Fire (Class) – 1 & P (For FR grade) • Acoustics – NRC 0.77 (For E300* Mounting) • Thermal conductivity (W/mk)– na • Climate (°C, RH) – 50, 70 • Light reflectance (%) – 75 (Maple Arce) • Green (VOC, RC %) – Low, 25
Short Text : Acoustic treatment- fabric wrapped pinew Long Text : Supply and Installation of Anutone Soak Cord, square edge, fabric wrapped pinewood fiber panel of size 600x2400x20mm, density 400 kgs/m3, weight 8kg/m2 installed by using Anutone Strut framework system with non-visible fasteners using Anutone Strut H-Spline.The Anutone Strut framework systems includes Anutone Strut CC22 Cross Channel having thickness 0.55mm, length 3600mm, knurled web 40, depth 22mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm c/c. Anutone Strut H-Spline having sectional thickness 2mm and length 2400mm to be fixed perpendicular to the Strut CC22 Cross Channel at 600mm centers. The Kerfed edge fabric wrapped panels shall be then inserted into the Strut H-spline along their long edges of 2400mm against framework to perfect fit with staggered short edges. Note: Thickness is given for bare Panels, 4mm for cord fabric.(fabric colour as per choice) Optiona l: The system is backlined with the acoustical infill Anutone SynthPF 5x50Technical Parameters • Fire (Class) – 1 & P • Acoustics – NRC 0.95 (For 25mm C50 Mounting) • Thermal conductivity (W/mk)– 0.08 • Climate (°C, RH) – 50, 90 • Light reflectance (%) – colour dependant • Green (VOC, RC %) – Low, 30
Short Text : Stage crafting and lighting: 125W parlig Long Text : CE Certified 125W LEDParlight
Short Text : Stage crafting and lighting: 95W parligh Long Text : CE Certified 95W LED PARCAN light
Short Text : Stage crafting and lighting: 195W spotli Long Text : CE Certified 195W LED Profile Spotlight
Short Text : Stage crafting and lighting: 400W blinde Long Text : CE Certified 400W LED BLINDER Light 3200K
Short Text : Stage crafting and lighting: 150W moving Long Text : CE Certified 400W LED BLINDER Light 3200K
Short Text : Stage crafting and lighting: MS suspende Long Text : Customised MS Suspenders
Short Text : Stage crafting and lighting: Diecast alu Long Text : Diecast Aluminium C Clamp with safety chain.
Short Text : Stage crafting and lighting: safety bond Long Text : Safety bond with lock clip
Short Text : Stage crafting and lighting: name plate Long Text : 79mm Round Identification name plate
Short Text : Stage crafting and lighting: MSC track Long Text : MSC-Track with black epoxy polyester powder coated
Short Text : Stage crafting and lighting: light bar Long Text : Fixed stage lightbar, length 6 Mtrs
Short Text : Stage crafting and lighting: FOH light b Long Text : Fixed FOH lightbar, length 10Mtrs
Short Text : Stage crafting and lighting: winglader Long Text : Winglader
Short Text : Stage crafting and lighting: MS frame Long Text : MS, frame construction
Short Text : Stage crafting and lighting: IEC lightin Long Text : MS Fabricated 4way IEC Lighting Junction box
Short Text : Stage crafting and lighting: signal out Long Text : MS Fabricated 5pin DMX Signal OUT Junction box
Short Text : Stage crafting and lighting: signal in j Long Text : MS Fabricated 5pin DMX Signal IN Junction box
Short Text : Stage crafting and lighting: loop juncti Long Text : MS Fabricated 5pin DMX Signa Loop Junction box
Short Text : Stage crafting and lighting: lighting co Long Text : 1024 channel DMX Lighting Console
Short Text : Stage crafting and lighting: FRLS cable Long Text : FRLS 3Core 1.5 SQMM Cable
Short Text : Stage crafting and lighting: DMX splitte Long Text : DMX Splitter
Short Text : Stage crafting and lighting: 5 pin XLR c Long Text : 5Pin XLR Male & Female Connectors
Short Text : Stage crafting and lighting: termination Long Text : SITC of 5Pin XLR Termination Connectors for DMX
Short Text : Stage crafting and lighting: FRLS cable Long Text : FRLS 4Core 4SQMM Cable
Short Text : Stage crafting and lighting: FRLS cable Long Text : FRLS 7Core 1.5 SQM Cable
Short Text : Stage crafting and lighting: signal cabl Long Text : DMX Signal Cable
Short Text : Stage crafting and lighting: main curtai Long Text : Main Curtain (Velvet) - horizontal Open
Short Text : Stage crafting and lighting: rear curtai Long Text : Rear Curtain (Black) - Horizontal Open
Short Text : Stage crafting and lighting: wings Long Text : Fixed Wings
Short Text : Stage crafting and lighting: Frills Long Text : Frills
Short Text : Stage crafting and lighting: Scallop Long Text : Scallop
Short Text : Stage crafting and lighting: overhead gr Long Text : Fabrication of Overhead Grid on Stage
Badri Rai and Company
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .