| Sl No | Description | Qty | Unit | M/s Singh Electrical Works L1 | ANIKET COOLING AND REFRIGERATION CO L3 | P. M. COOLING AND ENGINEERING CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply ,Installation ,testing and commissiong of the following capacity Air Cooled Ceiling Suspended Ductable AC units, controls, necessary accessories of Rotary Type Scroll Compressor should be present on outdoor Unit.Refrigerant - R410 / R407 Compatible
(Make:-Hitachi/Mitsubishi /Blue Star /O'General)
5.5 TR DUCTABLE UNIT ( 2200 CFM) | 1 | Nos | 2,31,917 ₹2.3 L | 1,58,900 ₹1.6 L | 1,48,600 ₹1.5 L |
| 1.10 | 3 TR DUCTABLE UNIT ( 1200 CFM) | 1 | Nos | 87,934 ₹87,934 | 1,35,925 ₹1.4 L | 1,22,634 ₹1.2 L |
| 1.20 | 2 TR DUCTABE TYPE CONCEALED SPLIT ( 700 CFM) | 2 | Nos | 50,976 ₹1.0 L | 62,500 ₹1.3 L | 57,500 ₹1.1 L |
| 1.30 | 1.5 TR DUCTABE TYPE CONCEALED SPLIT ( 550 CFM) | 1 | Nos | 44,604 ₹44,604 | 55,600 ₹55,600 | 52,800 ₹52,800 |
| 2.00 | Dismantling of existing 2.5 Tr Ductable AC machine indoor units including ACP, continous grill,pipe lines with all accessaries and refixing the same after repair and renovation work at the desired place by necessary arrangements with mending good damages as per direction of EIC. | 3 | item | 1,274 ₹3,822 | 2,500 ₹7,500 | 3,000 ₹9,000 |
| 3.00 | Supply & Charging of extra Refrigerant Gas (410 A) in Air conditioning system. | 35 | kg | 943 ₹33,005 | 715 ₹25,025 | 650 ₹22,750 |
| 4.00 | Supply, installation, testing and commissioning of copper pipe line for Liquid Line and Suction Line with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 13/19 mm thick closed cell elastomeric nitrile rubber insulation with proper taping (make: Accroflex/Armacell/Suprime) as per direction E.I.C..
22.2 mm dia with 19 mm thick insulation | 9 | RMT | 1,083 ₹9,747 | 810 ₹7,290 | 825 ₹7,425 |
| 4.10 | 19.1 mm dia with 19 mm thick insulation | 9 | RMT | 828 ₹7,452 | 805 ₹7,245 | 790 ₹7,110 |
| 4.20 | 15.9 mm dia with 13 mm thick insulation | 30 | RMT | 465 ₹13,950 | 390 ₹11,700 | 380 ₹11,400 |
| 4.30 | 12.7 mm dia with 13 mm thick insulation | 12 | RMT | 421 ₹5,052 | 285 ₹3,420 | 290 ₹3,480 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
29 Jan 2024, 1:00 pmClosed
EEI,KNHED, PW Dte
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Repair and renovation of electrical installation work for the proposed modification of seminar hall and for Air conditioning work and Other electrical installation work at IBTMIH ,Kolkata- SITC of AC System
2024_WBPWD_642881_1
WBPWD/EE/KNHED/NIQ-104/2nd Call/23-24
Open Tender
A/C ORG
45 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹16,000
28 Apr 2026
10 Jan 2024
31 Jan 2024
16 Jan 2024
29 Jan 2024
16 Jan 2024
Amount
Supply ,Installation ,testing and commissiong of the following capacity Air Cooled Ceiling Suspended Ductable AC units, controls, necessary accessories of Rotary Type Scroll Compressor should be present on outdoor Unit.Refrigerant - R410 / R407 Compatible (Make:-Hitachi/Mitsubishi /Blue Star /O'General) 5.5 TR DUCTABLE UNIT ( 2200 CFM)
3 TR DUCTABLE UNIT ( 1200 CFM)
2 TR DUCTABE TYPE CONCEALED SPLIT ( 700 CFM)
1.5 TR DUCTABE TYPE CONCEALED SPLIT ( 550 CFM)
Dismantling of existing 2.5 Tr Ductable AC machine indoor units including ACP, continous grill,pipe lines with all accessaries and refixing the same after repair and renovation work at the desired place by necessary arrangements with mending good damages as per direction of EIC.
Supply & Charging of extra Refrigerant Gas (410 A) in Air conditioning system.
Supply, installation, testing and commissioning of copper pipe line for Liquid Line and Suction Line with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 13/19 mm thick closed cell elastomeric nitrile rubber insulation with proper taping (make: Accroflex/Armacell/Suprime) as per direction E.I.C.. 22.2 mm dia with 19 mm thick insulation
19.1 mm dia with 19 mm thick insulation
15.9 mm dia with 13 mm thick insulation
12.7 mm dia with 13 mm thick insulation
9.52 mm dia with 13 mm thick insulation
6.34 mm dia with 13 mm thick insulation
Supply and fixing of 4 CORE X 2.5 Sq mm Armoured copper Cable for ODU to IDU of Ductable Split Units as per Direction of E.I.C. (Make: Gloster / Havells/ RR Cable/ Finolex)
Supply, installation, testing and commissioning of PVC pipe (for drainage of water from IDU) with 6 mm thick Nitrile Rubber insulation.--DRAIN PIPE 25mm
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal (Make-Tata steel/Sail/Jindal) rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, venes, hangers, support etc as per approved drawings and specification of following sheet complete as required complete as per IS 655.--24 Gauge GSS Ducting site fabricated as per IS 655
Supply & Fixing of 13 mm thick Nitrile Rubber Foil Face Thermal Insulation on duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of 10 mm thick Nitrile Rubber Acoustic Insulation Under duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of Aluminium powder coated Supply air diffusers/grilles with VCD (Volume Control Damper) (Make: Systemair / Premire / Caryaire / Airmaster)
Supply & Fixing of Aluminium powder coated Return air diffusers/grilles without VCD (Make: Systemair / Premire / Caryaire / Airmaster)
Supply & Fixing of Duct Damper (Make: Systemair / Premire / Caryaire / Airmaster)
Supply & Fixing of retadrant nonporus double layer Flexible Connection (CANVAS ) between each Indoor Unit & Duct and for concealed split AC as per Direction of E.I.C .
Supply & Laying of Cu conductor flexible Communication cabling between ODU and IDU as per OEM. Cable shall be laying through hard PVC conduit pipe
Supplying, fabrication & fixing M.S. U-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 1.5/2/3/5.5 TR concealed type split/ductable AC incl drilling 3 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (11% 3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm for including necessary welding for placing the platform, MS checkered sheet including 50mm x 50 mm x 6 mm Angle in each platform in outer edge for transmitting the load centrally through 2 nos (50 mm x 50 mm x 6 mm) Angle of 2 mtr. length each inserted into the exiting wall Area of the platform as follows, Dimension [10 x 6] ft
Dimension [8 x 5] ft
Dimension [8 x 4] ft
Dimension [4 x 3] ft
(Rate should be quotated including all taxes and duties and GST)
P. M. COOLING AND ENGINEERING CO
ANIKET COOLING AND REFRIGERATION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
2911.pdf
Tender Documents • 1.46 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_1381503.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid