Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.9 L+₹2.1 L (6.13%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.1 L+₹2.3 L (6.70%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹36.9 L+₹3.1 L (9.05%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.9 L+₹9.1 L (27.1%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR AND REPLACEMENT OF LT PANEL, BUS BAR AND OTHER CONNECTED ITEMS FOR RATIONALIZATION OF DG SETS LOAD AT VARIOUS LOCATIONS AT AF STN THOISE UNDER GE(AF) THOISE
2023_MES_598795_1
GEAF/T-31/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GARRISON ENGINEER (AF) THOISE
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹80,000
Yes
22 Aug 2023
27 May 2023
19 Jun 2023
27 May 2023
17 Jun 2023
3 Jun 2023
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soil complete all as specified and as directed by Engineer-in-Charge.
Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a hard/dense soil complete all as specified and directed by Enginer-in-Charge.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engineer-in-Charge. Note:-Excavation and earth work to be measured and paid for separately
Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness of 18cm shall be measured for payment purpose.
M&L for in repair / replacment XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 400 Sqmm,3.5 core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 300 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 240 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 185 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 6.00 above but of size cross-sectional area 150 Sqmm, 3.5-core complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm, complete all as specified and as directed by Engineer-in-Charge. Make: Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm, complete all as specified and as directed by Engineer-in-Charge. Make : Denson/ M Seal/ Raychem
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2, complete all as specified and as directed by Engineer-in-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens/ Havells.
All as per BOQ Srl Item No 13.00 above but of size Capacity 160 Amps with Breaking Capacity 25 KA complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 13.00 above but of size Capacity 200 Amps with Breaking Capacity 36 KA complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 13.00 above but of size Capacity 400 Amps with Breaking Capacity 36 KA complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 13.00 above but of size Capacity 630 Amps with Breaking Capacity 45 KA complete all as specified and as directed by Engineer-in-Charge.
M&L for in repair / replacement on load Change over switch, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, on load, conforms to IS:13947 (Part-3); IEC:60947-2, Center handle, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Havells , Indo-Asian/ L&T/ Legrand/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
All as per BOQ Srl Item No 18.00 above but of rating 200 Amps complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 18.00 above but of rating 400 Amps complete all as specified and as directed by Engineer-in-Charge.
All as per BOQ Srl Item No 18.00 above but of rating 630 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply, fabrication and fixing of feeder piller box made out of MS sheet of 1.6 mm thickness bent to shape & size factory made with welding,bending works suitable for and including 200 Amps rated aluminium bus bar(length of bus bar not less than 60 cm )4 Nos, making holes of any size with suitable size of nuts, bolts and washers complete with mounting legs of size 40 x 40x 5 mm and length of angle iron not less than 1 mtr to be embeded in PCC below GL ground and 1.5 mtr above ground level including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/outgoing cable connections with required size of cable lugs with proper crimping(for connection of existing cable) complete all as specified and directed by Engr-in-Charge.
S&F in repairs including taking out old LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 240 x 140 x 95 mm (internal dimensions) comprising 4 Nos aluminium busbar of 200 Amps complete on 6 Amp MCB SP adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete all as specified and directed by Engr-in-Charge. Make: Sintex cat part No. GSJB 2817 or equivalent as approved by GE
M&L in repair Earthing complete with copper plate electrode 600x600x3.15mm thick electrode burried directly in ground not less than 3.0 mtr deep below normal ground level with top edge of earth plate not less than 2.5 mtr below normal ground level connected to and including and 20x3 mm copper strip as earth lead by means of bolt ,nuts, check nuts, and washers of stainless steel and duly welded incl PCC pit in PCC 1:2:4 type B-I angle iron 40x40x3mm frame, pit in PCC 1:2:4 type B-I cover 40mm reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20mm bore with funnel and wire mashand medium grade GI protection pipe 40mm bore and earth wire up all as shown in electrical plate No 3 of MES SSR- Part-I all as directed and specified by Engineer-in-charge. Note : (i) Excavation work should be done by manpower only. (ii) Earth test should be done by contractor and if required result is not found entire earthing should be re done by contractor without accruing any extra cost to the Govt.
Supply and laying in repairs incluidng taking out old GI tubes Light grade , with all fitting such as bend,tee, elbow, socket etc complete all as specified and directed by Engineer in Charge of size 80 mm Dia bore connected to pumping set inlet and discharge complete all as specified and as directed by Engineer-in-Charge. Make:- Jindal/Surya/Tata/ Bansal
M &L for earth continuity conductor or main earthing lead in repairs including taking out old strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required of copper strip 32x6 mm complete all as specified and as directed by Engineer-in-Charge.
M &L for earth continuity conductor or main earthing lead in repairs including taking out old strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required of copper strip 20x3 mm complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety size 2mtr x1 mtr incluidng taing out old mats of any size complete all as specified and as directed by Engineer-in-Charge.
M & L for Danger notice plate of 1.6mm thick mild steel sheet , vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamp bolts and nuts of approved size for LT 20x15 cm size complete all as specified and as directed by Engineer-in-Charge.
M & L for cross arms bracing , supports clamp and back plates fabricated from structural steel sections including nuts, bolts , washers , welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engineer-in-Charge.
M & L for wiring for circuit with 2x1.5 sqmm copper conductor single core cable with 1x1.5 sqmm copper wire for earthing connecting from street light to Junction box laind in recess/ surface complete in PVC conduit as specified and directed including taking down old wiring complete all as specified and as directed by Engineer-in-Charge.
RAVI KUMAR
FANGALIA TRADERS
HANS ENTERPRISES
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .