GE CAMPBELL BAY
GE CAMPBELL BAY ARMY LAND CAMPBELL BAY GREAT NICOBAR-744302
SPL REPAIR AND REPLACEMENT OF LIGHT SWITCH GEARS LIGHT PANELS IN BLDG NO P 30 A8 JCO LIVING BLDG NO P120 JCO MESS AT 172 INF TA MADRAS CINCAN LAND (ARMY) SPL REPAIRS OF LT PANELS AND ALLIED WORKS AT INS BAAZ CAMPBELL BAY UNDER GE CAMPBELL BA
2026_MES_787844_2
8260/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CAMPBELL BAY
AS PER NIT AND TENDER
9 documents required · 9 mandatory
₹500
GE CAMPBELL BAY
₹57,000
Yes
16 Oct 2026
16 Oct 2026
4 Nov 2026
16 Oct 2026
2 Nov 2026
24 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down DB with MCBs/main switch of any size and making good disturbed surface of wall/floor complete all as specified and as directed. | 6 | Each | - | - |
| 2 | Taking down carefully sub-main wiring of any description and making good the disturbed surfaces to match the existing complete all as specified and as directed. | 132 | RM | - | - |
| 3 | M & L for sub main wiring (concealed) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface inc taking out old existing wire and conduit all as specified and directed.
Note:
(i) 3 run of 6 Sqmm & one run of PVC conduit shall be measured as single unit
(ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. | 92 | RM | - | - |
| 4 | M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface inc taking out old existing wire and conduit all as specified and directed.
Note:
(i) 3 run of 4 Sqmm & one run of PVC conduit shall be measured as single unit
(ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. | 40 | RM | - | - |
| 5 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. | 252 | Point | - | - |
| 6M & L for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 Sqmm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes , switch plates of suitable make and 1.5 Sqmm copper earth continuity wire connected to earth dolly complete for the following: | |||||
| 6.1 | One Light/ Fan point controlled by one switch complete all as specified and as directed. | 140 | Point | - | - |
| 6.2 | One switch socket outlet modular type 3 pin 6 Amp on same board complete all as specified and as directed. | 39 | Point | - | - |
| 6.3 | One switch socket outlet modular type 3 pin 6 Amp on independent board complete all as specified and as directed. | 53 | Point | - | - |
| 7 | Description all as per item No 6.00 above but 2.5 Sqmm cable size and 2.5 Sqmm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board complete all as specified and as directed. | 20 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
8260TENDER.pdf
Tender Documents • 1.61 MB
BOQ_890765.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .