Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30 LAccepted-AOC 1241 4TH FLOOR SOLITAIRE CORPORATE PARK BUILDING NUMBER 12 ANDHERI GHATKOPAR LINK ROAD ANDHERI EAST | L1 | Accepted-AOC L1 | |
| 2 | L1₹30 LAccepted-AOC 15 1ST FLOOR SHIVA JI MARG DIGGI HOUSE RAM SINGH RAOD JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L1 | Accepted-AOC L1 | |
| 3 | L1₹40 LAccepted-AOC 101 KRISHNA COLONY NEAR AIRPORT FLYOVER THANA SANGANER JAIPUR 302029 | JAIPUR | JAIPUR | RAJASTHAN | 302029 | L1 | Accepted-AOC L1 | |
| 4 | L1₹3 CrAccepted-AOC JAIPUR | JAIPUR | L1 | Accepted-AOC L1 | |
| 5 | L1₹52,550Rejected-Finance 5 1 GROUND FLOOR BEES DUKAN ADARSH NAGAR JAIPUR 302004 | JAIPUR | RAJASTHAN | 302004 | L1 | Rejected-Finance Reject in Financial Evaluation as per Attachment |
Tender Value
₹6 Cr
EMD Value
₹6 L
Closing Date
29 Sept 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Medical Superintendent cum Member Secretary, RMRS
SMS Hospital, Jaipur
Two Year Rate Contract for the Procurement of Heart Valves
2020_SMSMC_196689_1
2278_25.08.2020
Open Tender
Miscellaneous Goods
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Member Secretary, RMRS, SMS Hospital, Jaipur
₹6 L
Yes
SMS Hospital, Jaipur
18 Dec 2020
26 Aug 2020
30 Sept 2020
26 Aug 2020
29 Sept 2020
15 Sept 2020
3 Sept 2020
90 days
Bileaflet Mechanical Valve All Size of bileaflet Mitral and Aortic Valve with continuously rotating leaflets.
Mechanical Valve Moulded pivot Bileafleat prosthetic heart valve with moulded pivot made up pyrolytic carbon (mitral +aortic) opening angle 75 degree or more. should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon. USFDA approved. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve Open pivot design. Bileafleat prosthetic Heart valve with open pivot made of pyrolytic carbon (mitral + aortic) of all sizes. should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve with pivot guard design. Bileafleat prosthetic Heart valve with open pivot made of pyrolytic carbon (mitral + aortic) of all sizes. should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve. Bileafleat prosthetic Heart valve with opening angle 90 degree made of pyrolytic carbon (mitral + aortic) of all sizes. should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Mechanical Valve. Monoleafleat prosthetic Heart valve with opening angle 75 degree or more, made of pyrolytic carbon (mitral + aortic) of all sizes. should have minimal gradient across the valve in vitro and vivo. The housing of prosthesis should be rotatable to give optimal positioning for the valve with titanium stiff ring. should be in use for more than 20 year and acceptability by cardiac surgeon, low profile sewing ring made up of polyester, should be radio opaque during X-ray and fluoroscopy. Expiration Date should be 3 years from the date of purchase.
Triple composite procine valve Must be CE (European Certificate to be submitted) or FDA approved. Mitral and aortic.
Bioprosthetic valve. Porcine valve of all sizes. Mitral and aortic
Bioprosthetic valve. Bovine pericardial valve with silicone rubber sewing ring, stented (cobalt-chromium alloy material)
Bioprosthetic valve. Bovine pericardial valve with glide technology (GT) and linx anticalcification (AC) designed for supra-annular placement in aortic position.
Bioprosthetic valve. Triple composite bovine pericardial valve with elgiloy stent material for both mitral and aortic position.
BIEAFLET AORTIC VALVE WITH CONDUIT Should have double velour woven graft. Should be collagen impregnated to control hemostasis and reduce the hemorrhagic complications. Should have mechanical and bioposthetic heart valve with low pressure gradients. With pivot guard design and leaflet opening and >80 degrees. Ciff design should enhance implantability. Should have minimum taper conduit to facilitate strong coronary anastomosis. Should not have any pleats to allow easier positioning and attachment of the coronary arteries. Wide range of sizes from 19mm-33mm. Should have both CE and FDA approval. Dacron graft of 3mm.
Bio prosthetic conduit valve to replace aortic root (Bio-bentall).
Stent less tissue heart valve (CE certified) for mitral and aortic position with all the sizes available should be in clinical use with long term proven result.
Free style tissue heart valve with aortic conduit of all sizes for aortic position to replace aortic root, should be stent less, should have zero pressure preservation technique to given long term durability.
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. A Flexible
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. B Rigid
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. C physiological
Annuloplasty rings annuloplasty rings for mitral and tricuspid annulus. All sizes should be available. It should be available in the following vatieties. D Incomplete Ring
Right ventricle to pulmonary artery conduit of all sizes. Both xenograft and prosthetic graft.
Suture less heart valve for aortic position and for Mitral position.
Trans catheter aortic valve replacement valve (TAVR)
Trans catheter mitral valve replacement valve (TAMR)
Arch Aneurysm graft with elephant trunk surgery extension.
Bovine Pericardial Valve with Resilia Tissue (V-Fit) Technology
Mechanical Heart valve with open pivot design for supra annular placment
M/S SINGAPORE MEDICARE SYSTEM
RADIANCE MEDICAL SYSTEM
SAHU SURGICAL EMPORIUM PVT .LTD.
India Medtronic Private Limited
SHUBH ASSOCIATES
M/S SINGAPORE MEDICARE SYSTEM
GSS DISTRIBUTORS
SAHU SURGICAL EMPORIUM PVT .LTD.
RADIANCE MEDICAL SYSTEM
SHUBH ASSOCIATES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .