Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹11.9 L
Closing Date
28 May 2026, 2:00 pmClosed
CPO-EPMC & CONSUL.
LAST MILE CONNECTIVITY WORK INCLUDING PE LAYING AND ASSOCIATED WORKS FOR UP
2600026838-HD-09050
5100026838
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
₹11.9 L
7 May 2026
7 May 2026
28 May 2026
28 May 2026
7 May 2026 - 12 May 2026
12 May 2026
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | BPR TF Works | BPR TF Works — TF Works -20 mm Dia. - On completion of laying, jointing, excavation, backfilling, compaction, necessary leakage testing and submission of DPR & Graphs. Inclusive of liasoning, restoration, pedestal works and fittings ( example- saddle) required for TF. Item shall include supply & installation of Pipe piece (GI Riser 1.2 M) with Riser isolation valve (inclusive). 20 MM MDPE pipe shall be supplied by HPCL (FIM from HPCL store) | - | each |
| 2 | BPR LMC to NGC Conversion | BPR LMC to NGC Conversion — NGC of Existing LMC along with supply & installation of suraksha hose Pipe with clamps with burner conversion. Supply & installation of GI pipe for Connectivity between TF riser and LMC wherever required, Testing of LMC & supply & installation of fitting wherever required. Scope includes appliance valve (wherever required) to complete the conversion of existing LMC to NGC | - | each |
| 3 | BPR Existing MDPE(<63 mm) | BPR Existing MDPE(<63 mm) — Flushing, Testing, Commissioning & identification & rectification of Repair works of existing < 63 MM Dia MDPE network. Item is inclusive of required liasoning, excavation & restoration of pits required for charging & supply and installation of PE fittings to be installed for rectification of leakage. Supply of MDPE pipe shall be done by HPCL store. This item is inclusive of nitrogen purging required for commissioning. | - | meter |
| 4 | BPR Interloping MDPE Laying | BPR Interloping MDPE Laying — Laying of < 63 MM MDPE pipe for interlooping, SR connectivity by using any methodology in all types of strata required for commissioning of laid pipeline network including restorations all type of roads. | - | meter |
| 5 | BPR Existing MDPE(=>63 mm) | BPR Existing MDPE(=>63 mm) — Flushing, Testing, Commissioning & identification & rectification of Repair works of existing >= 63 MM Dia MDPE network. Item is inclusive of required liasoning, excavation & restoration of pits required for charging & supply and installation of PE fittings to be installed for rectification of leakage. Supply of MDPE pipe shall be done by HPCL store. This item is inclusive of nitrogen purging required for commissioning. | - | meter |
| 6 | BPR Interloping MDPE Laying | BPR Interloping MDPE Laying — Laying of >= 63 MM MDPE pipe for interlooping, SR connectivity by using any methodology in all types of strata required for commissioning of laid pipeline network including restorations all type of roads. Schedule 2 Manadatory: No | - | meter |
| 1 | NB-Bijnor TF Works | NB-Bijnor TF Works — TF Works -20 mm Dia. - On completion of laying, jointing, excavation, backfilling, compaction, necessary leakage testing and submission of DPR & Graphs. Inclusive of liasoning, restoration, pedestal works and fittings ( example- saddle) required for TF. Item shall include supply & installation of Pipe piece (GI Riser 1.2 M) with Riser isolation valve (inclusive). 20 MM MDPE pipe shall be supplied by HPCL (FIM from HPCL store) | - | each |
| 2 | NB-Bijnor LMC to NGC | NB-Bijnor LMC to NGC — NGC of Existing LMC along with supply & installation of suraksha hose Pipe with clamps with burner conversion. Supply & installation of GI pipe for Connectivity between TF riser and LMC wherever required, Testing of LMC & supply & installation of fitting wherever required. Scope includes appliance valve (wherever required) to complete the conversion of existing LMC to NGC | - | each |
| 3 | NB-Bijnor Existing MDPE(<63 | NB-Bijnor Existing MDPE(<63 — Flushing, Testing, Commissioning & identification & rectification of Repair works of existing < 63 MM Dia MDPE network. Item is inclusive of required liasoning, excavation & restoration of pits required for charging & supply and installation of PE fittings to be installed for rectification of leakage. Supply of MDPE pipe shall be done by HPCL store. This item is inclusive of nitrogen purging required for commissioning. | - | meter |
| 4 | NB-Bijnor Interloping MDPE | NB-Bijnor Interloping MDPE — Laying of < 63 MM MDPE pipe for interlooping, SR connectivity by using any methodology in all types of strata required for commissioning of laid pipeline network including restorations all type of roads. | - | meter |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2600026838-HD-09050.pdf
TENDER_DOCUMENT • 48.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .