Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 CrAccepted-AOC | ₹11.4 Cr | L1 | Accepted-AOC Being Lowest Tender |
| 2 | L2₹11.4 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹11.4 Cr | L2 | Rejected-Finance Higher than Lowest Tender |
| 3 | L3₹11.8 CrRejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹11.8 Cr | L3 | Rejected-Finance Higher than Lowest Tender |
| 4 | L4₹12.3 CrRejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA UDYAM DL 06 0048538 | NORTH WEST DELHI | DELHI | 110035 | ₹12.3 Cr | L4 | Rejected-Finance Higher than Lowest Tender |
| 5 | L5₹12.6 CrRejected-Finance | ₹12.6 Cr | L5 | Rejected-Finance Higher than Lowest Tender |
Tender Value
₹12.8 Cr
EMD Value
₹9.7 L
Closing Date
6 Feb 2021, 6:00 pmClosed
CHIEF ENGINEER KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
ADDN/ ALTN TO CERTAIN OFFICERS MD ACCN AT KOLKATA
2020_MES_385722_1
89028/E8
Open Tender
Civil Works
540 days
Kolkata
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE (Alipore) Kolkata
₹9.7 L
Yes
4 Mar 2021
12 Oct 2020
8 Feb 2021
12 Oct 2020
6 Feb 2021
27 Jan 2021
Amount
SCHEDULE 'A' PART I (B/R WORKS)
Taking down old damaged cement plaster of any description including racking out joints hacking for key, scrubbing down with water upto 04 storied of building complete all as specified and as directed.
ditto all as per item No. 1.01 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.01 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Chipping of unsound /weak concrete materials (including taking down old cement plaster) from slabs, beams, columns, lintel, chajja, fin, facia etc. by any means as directed by Engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign materials, loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed. (upto 4 storey of building) for 25mm average thickness for slabs/Chajja.
ditto all as per item No. 1.04 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.04 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
ditto all as per item No. 1.04 here-in-before but 50mm average thickness for beams/ lintels (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.07 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
ditto all as per item No. 1.04 here-in-before but 60mm average thickness for column (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.10 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Add or deduct for every 10 mm thickness extra (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.13 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical as per manufacturer's instruction followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed. upto 12 mm dia bar (upto 4 storey of building)
ditto all as per item No. 1.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.16 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge above 12 mm dia bar (upto 4 storey of building)
ditto all as per item No. 1.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.19 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material and labour for providing single coat epoxy bond adhesive on prepared non metallic surface (existing surface) and applying by brush as per manufactureres instruction/ specifications. The bonding agents shall have minimum compressive strength of 40N/mm² complete all as specified and as directed (upto 4 storiey of building).
ditto all as per item No. 2.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimum specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. (upto 4 storey of building)
ditto all as per item No. 2.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for introducing new reinforcement bars upto 12mm dia bars Fe 550CRS for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed. (upto 4 storey of building)
ditto all as per item No. 2.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed. Above 12 mm dia bar Fe 550 CRS (upto 4 storey of building)
ditto all as per item No. 2.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.09 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete as per drawing and direction of Engr-in-charge including power drilling holes of appropriate diameters to a minimum depth equal to 12 times the diameters of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing, insertion of epoxy from cartridge, placing the shear key bar in position and allowing it to stay undisturbed for 24 hours. Rate shall be include cost of labour, all materials, T&P for power drilling in concrete, epoxy cartridge, plastic nozzle etc, complete incl cleaning the drilled holes of loose dust by blowing air complete all as spd and dir by Engr-in-charge. 12 mm dia Fe 550 CRS, 300mm long @ MS shear key of bar. The projection length of shear key shall be more than 10 times its diameter plus half of the thickness of cover to concrete plus bend length. (upto 4 storey of building)
ditto all as per item No. 2.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as spd and dir by Engr-in-charge. 60 mm average thickness of Column (upto 4 storey of building)
ditto all as per item No. 2.14 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.14 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and as directed. 50 mm average thickness of Beam (upto 4 storey of building)
ditto all as per item No. 2.17 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.17 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and as directed. Add or deduct for every 10 mm thickness extra (upto 4 storey of building)
ditto all as per item No. 2.20 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.20 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible . The mortar can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimum compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimum compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimum flexural strength 6.5N/mm2 complete all as specified and directed. upto 25 mm average thickness and (upto 4 storey of building).
ditto all as per item No. 3.02 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.02 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and as directed. (upto 4 storey of building).
ditto all as per item No. 3.05 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.05 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of bldg / structure, upto 15 meter height, above GL, of incl addl rows of scaffolding in stepped manner as per requirement of site, made with minimum 40 mm dia MS Tube, placed 1.5 meter C/C (maximum), horizontal & vertical tubes joint with cup & lock system with MS Tubes, MS Tube challis, MS clamps and stair case system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of wk and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with bldg etc wherever reqd, if feasible, for inspection of wk at reqd locations with essential safety features for workmen etc complete as per dirns and approval of GE.
Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of bldg / structure, above 15 m to remaining bldg height, above GL, incl addl rows of scaffolding in stepped manner as per requirement of site, made with minimum 40 mm dia MS Tube, placed 1.5 meter C/C (maximum), horizontal & vertical tubes joint with cup & lock system with MS Tubes, MS Tube challis, MS clamps and stair case system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of wk and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with bldg etc wherever reqd, if feasible, for inspection of wk at reqd locations with essential safety features for workmen etc complete as per dirns and approval of GE. Note for items No 3.08 & 3.09:- (1) The elevation area of structure (length X breath of building X height of bldg) cover with scaffolding shall be measured for payment purpose. (2) The payment shall be made one time only for execution of all items each face of bldg / structure. (3) After completion of work al scaffolding mtrls shall be removed from bldg / structure by the contractor and the same shall be the property of the contractor and rate to be quoted by the bidder accordingly.”
M&L for providing and inserting 12mm dia aluminium/ GI injection nipples along crack line honey combed area including drilling holes as required diameters upto depths from 40mm to 80mm or half the thickness of member (whichever is less) at required spacing as approved by GE for the concrete work surface upto 12 storey of building complete all as specified and as directed.
M&L for making groove of size 12 mm X 12 mm along the crack line on concrete surface, removing dust, foreign mtrls from crack line by blowing compressed air or other technology as approved by manufacturers and washing of crack line with water and including inserting 12 mm dia aluminium / GI injection nipples along crack line honey combed area including drilling holes as reqd diameters upto depths from 40 mm to 80 mm of half the thickness of member (whichever is less) at reqd spacing as approved by GE and including injection with approved putty (polymer modified cement mortar / polyester putty) and injected cementitious expanding grout admixture mtrls on washing and saturating the cracked surface by gun pumping from top most nipple and down wards and curing of putty completed as per manufactures instruction all as specified and as directed. (Any storey / height of bldg / structure) Note: Cementitious expanding grout admixture mtrls with PVC nozzles shall be measured and paid under item No 3.12.
Supply & application cementitious expanding grout admixture with the cement slurry at a dosage 225 ml per bag cement and injecting with high pressure grouting pump through non return PVC nozzles prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left with in the old concrete mass. When the flow of grout stops or shows refusals or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface, complete as per manufacturer’s instruction as specified and as directed. (Any storey / height of bldg / structure).
Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm (upto 04 storey of building).
ditto all as per item No. 3.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F shear connector of 8mm dia Fe 550 CRS & requisite length on the surface to be repaired for the bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertically followed by coat of epoxy Zinc primer as per the specification mentioned in complete all as specified and as directed. (upto 04 Storey of Building).
ditto all as per item No. 3.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for. (upto 04 storey of building).
ditto all as per item No. 3.17 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to sides of column, pillars, posts, stanchions for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.19 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Use and waste of steel formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed. (upto 04 storey of building)
ditto all as per item No. 4.01 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.01 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Use and waste of steel formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing horizontal or sloping and similar work exe 5 cm but not exe 10 cm thick complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.04 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to chullah hoods, chajjas, troughs, parapets and similar items including edges for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for RCC for M 30 (Design Mix) using 12.5 mm graded crushed stone aggregate as in parapets, slab supported on wall and similar work all as specified and directed (upto 04 storey of building).
ditto all as per item No. 4.08 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 10mm dia Fe 550 CRS and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. (upto 04 storey of building).
ditto all as per item No. 4.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.complete all as specified and as directed. (upto 04 storey of building)
ditto all as per item No. 4.14 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Demolition of Brickwork quoins, arches, pillars etc but excluding ashlar facings, dressed all store work and precast concrete articles built in cement mortar complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius and all as directed. (upto 04 storey of building).
ditto all as per item No. 4.20 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.20 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 5.02 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for Rendering 15mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 5.04 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.04 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Rendering 20mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound applied as per manufacturers instructions shall be laid over 10mm thick plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and as directed. (upto 04 storey of building). (Note: WPC shall be measured and paid separately).
ditto all as per item No. 5.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.07 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Rendering 5mm thick with CM (1:4) on or concrete surfaces and finished the surface even and smooth as in ceiling complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 5.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.10 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for complete removal of existing old surfaces of wall and preparation of old or previously untreated surfaces and applying two coats white cement based wall care putty and one coat alkali resistant primer, sanding the surfaces and finally applying two coats of Anticarbonation paint (upto 04 storey of building) complete all as specified and as directed. Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work.
ditto all as per item No. 5.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.13 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats white cement based wall care putty and one coat alkali resistant primer, sanding the surfaces and finally applying two coats of Anticarbonation paint complete all as specified and as directed.(upto 04 storey of building). Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work.
ditto all as per item No. 5.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.16 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 5.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.19 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of old surface and applying one coats of white wash on ceiling to match with the new one complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of new plastered surface and applying two coats of acrylic washable distemper over a coat of primer over 3 mm thick (minimum) cement base wall putty and complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applyingtwo coats of acrylic washable distemper over a coat of primer over 3 mm thick (minimum) cement base wall putty to match with the new surface on wall and complete all as specified and as directed. (upto 04 storey of building) .
ditto all as per item No. 6.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L Preparing new plastered surfaces of wall and applying 3 coats of white wash on walls surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of old surface and applying one coat of white wash on wall surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.11 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply only Integral Liquid water proofing compound. (upto 08 storey of building).
Dismantling of floor hearth or wall tiling incl cement mortar and backing coat, and rubbish off the premises (out of MOD land), complete all as specified and as directed. (upto 12 storey of building).
M&L for double charged vitrified ceramic tiles not less than 08 mm thick (square /rectangular) polished dark shade, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed white or coloured cement to match the dark shade of the tiles, with and all as specified and directed. (upto 12 storey of building).
M&L for double charged vitrified ceramic tiles not less than 08 mm thick (square /rectangular) polished dark shade, area of each tiles not exceeding 0.36 sqm, as in Skirting/ Dado etc. set and jointed in neat cement slurry and pointed white or coloured cement to match the dark shade of the tiles, with and all as specified and directed. (upto 12 storey of building).
Roughening of surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3 KG/Sqm of cement complete all as specified and as directed.(upto 12 storey of building)
M&L backing coat/screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:3) as in dado/skirting complete all as specified and as directed. (upto 12 storey of building).
M&L Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. (upto 12 storey of building).
M&L Non-skid coloured ceramic floor tiles not less than 08 mm area of each tile exc. 11 sqm but n exc 0.18 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. (Note:- Screed bed shall be measured and paid separately under respective items of Sch "A') (upto 12 storey of building).
M&L Glazed ceramic coloured wall tiles of size 450x300 & thickness not less than 08 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. (Note:- Rendering/backing coat shall be measured and paid separately under respective items of Sch "A') (upto 12 storey of building)
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling complete all as specified and as directed. (upto 12 storey of building).
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. (upto 12 storey of building)
Taking up or down 15mm steel tubing and connections, including removal from site complete all as specified and as directed.. (upto 12 storey of building).
S&F 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with antimicrobial property) fusion welded PP-R (polypropylene Random Co-Polymer) concealed pipes 20mm outer dia, ISI marked and fittings including plain PP-R fittings and brass threaded PP-R fittings and clamping, cutting and making good to the damages of grade PN-16, SDR- 7.4 including fixed to wall, ceiling or floors (upto 12 storey of building) complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, including removal from site complete all as specified and as directed.. (upto 08 storey of building) .
S&F 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with antimicrobial property) fusion welded PP-R (polypropylene Random Co-Polymer) concealed pipes 25mm outer dia, ISI marked and fittings including plain PP-R fittings and brass threaded PP-R fittings and clamping, cutting and making good to the damages of grade PN-16, SDR- 7.4 including fixed to wall, ceiling or floors complete all as specified and as directed.(upto 08 storey of building).
S&F 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. (upto 08 storey of building).
S&F in repairs 15mm bore Brass CP bib cock fancy type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002151 or HINDWARE Cat No- F730003 or PRAYAG Cat No PIS-06.
S&F in repair 15mm bore Brass CP two way bib cock fancy type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002163 or HINDWARE Cat No- F73004 or PRAYAG Cat No 8312.
S&F in repair 15mm bore Brass CP angular stop cock fancy type, with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002201 or HINDWARE Cat No- F730039 or PRAYAG Cat No 8310.
S&F in repair 15mm bore Brass CP stop cock concealed type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002361 or HINDWARE Cat No- F200007 or PRAYAG Cat No 8318.
S&F in repair PVC connection 15 mm size pipe with PTMT nut of Length 600mm complete all as specified and as directed. (upto 12 storey of building).
S&F in repair brass CP shower roses with or without swivel joints, with shower arm, 125mm size, including fixing to steel pipes or union complete all as specified and as directed. (upto 12 storey of building).
S&F in repairs Vitreous China wash basin (white), flat back, size 580 x 450 mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets, complete all as specified and as directed. (upto 12 storey of building).
S&F 40mm bore CPVC pipe with fittings complete fixed in wall/laid in floor complete all as specified and as directed. (upto 12 storey of building) .
S&F 38/40 mm bore CP waste coupling for steel sinks,basin etc with long screwed shanks and fly nuts, flange end bedded in red led, cement and other end fixed complete all as specified and as directed. (upto 12 storey of building).
S&F 32 mm bore brass CP bottle traps for wash basin with inlet and outlet screw for pipe and connections incl necessary packing complete all as specified and as directed by engineer-in-charge. (upto 12 storey of building).
S & F in repair vitreous china squatting pan of Orissa pattern long pan of size 580 mm x 440mm with integral foot rest white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as specified and as directed by Engineer-in-Charge. (upto 08 storey of building).
Supplying and fixing in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building). MAKE-PARRYWARE Cat No E8303 or HINDWARE PVC SLEEK SMART or PRAYAG Cat No 501S
S&F in repair Stainless steel kitchen rack / plate rack of size 31"x36"x10", made of stainless steel sheet not exc 1 mm thick etc complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F in repair CI Nahani trap of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F CP grating of 100mm dia, fixed with cement mortar (1:3).complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
M&L 25mm thick PCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
M&L 40 mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) and concrete surface is to be finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube (size19 sqmm MS tube of 19 gauge),fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame (size 15 sqmm MS tube of 19 gauge) welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004),complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section all as specified and as directed.(upto 12 storey of building).
S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F 100 mm long Butt hinges,stainless steel Grade 308 with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Supply & fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples Complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Supplying and fixing Mild Steel framed work such as grills, gratings, etc. with ends of bars soldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, railings and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed and design/shape approved by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 8.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 8.13 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material & labour preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 8.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 8.16 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for cement concrete ( 1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 8.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 9.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 9.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F CI spun pipes of 100 mm bore with out ears in any length fixed to wall with clamp spacing 1000 mm c/c including bituminous paints both side complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 9.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 9.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F CI bend with door of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F CI branch pieces single equal or unequal with door of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S/F CI cowl of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints fixed to walls with clamps spacing 1000 mm C/C , complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 9.09 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
S&F 110mm bore PVC(SWR) bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
S&F 110mm bore PVC(SWR) junction single (single T) equal or unequal fixed to wall complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
S&F 75mm bore PVC(SWR) pipe single socket in any length rubber ring joints fixed to walls with clamps spacing 1000 mm C/C , complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 9.13 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
S&F 75 mm bore PVC(SWR) bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
S&F 75mm bore PVC(SWR) junction single (single T) equal or unequal fixed to wall complete all as specified and as directed by Engineer-in-charge. (upto 08 storey of building).
Material & labour preparation of old painted wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 12 storey of building).
Material & labour preparation of old painted steel surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 12 storey of building).
Supply and fixing in repairs 4.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Supply and fixing 4.0 mm thick frosted Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Taking down window/door shutter area exc 1 sqm but n exc 2 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Taking down chowkat with shutter (without taking off shutters from the frame) area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F 2nd Class HW Plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed. (upto 12 storey of building).
S&F 35 mm thick factory made flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side. (upto 12 storey of building).
S&F 35mm thick 2nd class hard wood gauged & skeleton shutter factory made , open rebated & prepared to receive gauged, (without sash bar) edge of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauged etc, all as specified and directed. (upto 12 storey of building).
S&F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles n exc 200 cm each. (upto any height of building).
S& F 50 mm long butt hinges medium weight cold rolled mild steel and fixed all as specified and directed. (upto any height of building).
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast al alloy all as specified and as directed. (upto 12 storey of building).
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete all as specified and as bidirected by Engineer-in-Charge. (upto 12 storey of building).
M&L for 25x4mm size mild steel flat iron as in hold fast conforming to Fe-290 Gide E-165 complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S & F second class hard wood beads, straight (n exe 3 sq cm) for glazed or gauzed joinery, renewed, including mitres etc complete all as specified and as directed by Engineer-in-charge. (upto any height of building).
Taking down door shutter exe 1 Sqm and n exe 2 Sqm each after resecuring or easing and adjusting including refixing in same opening (upto any height of building) .
Dismantling PVC(SWR) pipe 150 mm bore including all fittings, heads, shoes, swan necks etc complete all as specified and directed by the Engr-in-Charge.(upto any height of building).
Taking down existing roof treatment and taking out existing cracked plaster by manually or mechanically and wire brushing and cleaning the existing surface with water complete all as specified and as directed by the Engr-in-Charge.
Dismantling water tank and removing from site of 2000 litres capacity (upto any height of building).
Dismantling wrought iron or mild steel work of any description not otherwise provided for (upto any height of building) .
M&L for PVC perforated sheet 6mm thick, rounded hole of dia 12mm staggered type c/c spacing 25mm with MS frame (size 40X40X5mm thick) fixing on beam and column with nut and bolt of required size including dismantling of old RCC jallies complete all as specified and as directed. (upto 04 storey of building) Note:- Shape / Design of Jallies as approved by GE
ditto all as per item No. 10.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for cutting chases, pinning, in making good to facing where required of brick wall and pointing in cement mortar 1:3 to ends and cutting chases for concealed water tubing and concealed conduit wiring etc and making good surfaces (upto 04 storey of building) .
ditto all as per item No. 10.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 10.18 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Cutting holes in brick work for inserting hold fast etc including making good the adjacent area with cement and sand mortar 1:3 or PCC 1:2:4 type B, as required at site complete all as specified depth of embedded potion of hold fast or legs measured from the face of the jamb into the wall exc half brick but n. exc one brick (upto any height of building) .
S&F in repair towel rail of brass chromium plated tube 19 to 20 mm dia 600 mm long `D' type complete with brass chromium plated screw complete all as specified and directed. (upto 12 storey of building) .
Taking down steel window/ventilator with guard bar of any description and in any position complete all as specified and directed. (upto any height of building) .
M/L for Powder coating Anodised aluminium frame (minimum thickness of Powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete with the following section of frame:- (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM (ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM, complete all as specified and directed. (upto 04 storey of building).
ditto all as per item No. 11.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 11.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and fixing aluminium anodised (Powder coated) Three track sliding window shutters of any color, (thickness or Powder coating not less than 50 micron), ( 2 Nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with the following section of shutter:- (i) 'H' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick,complete all as specified and directed. (upto 04 storey of building).
ditto all as per item No. 11.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 11.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
ditto all as per item No. 11.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 11.09 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Materials and labour for providing and fixing anchor fastener system mechanical/ epoxy for connections in concrete i/c power drilling, cleaning of holes by air blowing, insertion of epoxy cartridge with plastic nozzles as required, placing internally threaded screw driving of bolts etc. upto to 10mm dia bars and complete all as specified and as directed.(upto 08 storey of building).
ditto all as per item No. 11.12 here-in-before but for above 10mm dia and upto 12mm dia bars, complete all as specified and as directed.
M& L for 15mm thk screed bed in CM (1:3) with waterproofing compound for laying of APP membrane complete all as specified and as directed by the Engr-in-Charge. (upto 08 storey of building).
M& L for bitumen primer shalikote T-32 @ 0.70 KG PER Sqm over the cement plaster incl preparation of surfaces as per manufacturer's instruction complete all as specified and as directed by the Engr-in-Charge. (upto 08 storey of building).
M&L for applying one coat of bitumen grade 85/25 over the primed surfaces @1.20 Kg per Sqm including cleaning the surface complete all as specified and directed. (upto 08 storey of building).
S&L 3MM thick prefabricated plastomeric water proofing membrane (Polyester reinforced) with spun bonded polyester mat as a core (APP membrane) (Weight not less than 3 kg per sqm ) laid over bituminous coated surface of roof and applied with lpg torch and applying uniform pressure with a roller /wet cloth to ensure to remove entrapped air, if any all as per manufacturer's instruction .The APP membrane shall be overlap of not less than 100mm and 150mm as end lap and side lap respectively as per manufacturer instruction .The over lapping and joints will be thermosealed with the propane torch complete all as specified and as directed by the Engr-in-Charge. (upto 08 storey of building).
M&L for cement concrete tiles 30CM X 30CM X 20MM thick, machine pressed tiles, set jointed and pointed in neat cement slurry on roof over and including 15 mm thick bedding layers in CM 1:3, cut and finished neatly and polished etc and complete all as specified.(upto 08 storey of building).
Materials and labour for complete removal of existing treatment of wall surfaces and applying texture painting with design and pattern as approved by GE complete all as specified and as directed.(upto 04 storey of building).
ditto all as per item No. 11.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply and fix rotational moulded PVC water storage tank three layers 2000 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I. (upto any height of building).
Disconnecting existing water tank of size exc 1000 Ltrs but n.exc 2000 litres, setting aside for cleaning & removing scale and dirt and refixing the same in new or old position after cleaning with bleaching powder @250 gms/tank and removing all scale and dirt etc complete all as specified & directed.(upto any height of building).
S&F in repairs toilet paper holder fixed to wall with chromium plated brass screws complete all as specified and as directed. (upto any height of building).
Supply & fixing in repair wash down P or S trap water closet (pedestal pattern) including connection to drain (or outgoing pipe) and to flush pipe etc. and making good the damaged surfaces complete all as specified and as directed by the Engr-in-Charge. (Upto any height of building). MAKE-CERA Cat No S1050102 or HINDWARE Cat No- 20044.
S&F PVC water closet seat cover heavy duty white closed pattern with flat bottom and cover and mild steel CP hinging device complete. (upto any height of building).
S&F in repairs brass CP soap dish, fixed with brass screws or embedded in wall complete all as specified and as directed. (upto any of building).
S&F in repair 15 mm bore CP hand shower (faucet) with one meter flexible tube with wall hook complete all as specified and as directed. (upto any height of building). MAKE-CERA Cat No T9962A1 or HINDWARE Cat No- F160001 or PRAYAG Cat No BEA-87.
S&F in repair wall mixture brass CP tap for mixing hot and cold water including three joints to 15 mm bore pipes or union and plugging and screwing to wall complete all as specified and as directed. (upto any height of building). MAKE-CERA Cat No F3002401 or HINDWARE Cat No- F730020 or PRAYAG Cat No PIS-75.
S&F in repair wash hand basin mixture Brass CP tap for mixing hot and cold water including three joints to 15 mm bore pipes or union and plugging and screwing to wall complete all as specified and as directed. (upto any height of building). MAKE-CERA Cat No F3002461 or HINDWARE Cat No- F730009 or PRAYAG Cat No 8350.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. (upto any height of building).
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm and including 38/40mm CP waste coupling (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed. (upto any height of building).
Supply and Fixing of drapery rod made of electric resistance welded MS pipe of 21 mm dia having a coating of corrugated virgin PVC extrusion and cover with ABS plastic, complete all as specified. (upto any height of building).
Supply and Fixing of end finials for drapery rod and including closed type stainless steel all brackets fixed on wall, complete all as specified and as directed. (upto any height of building).
S&F for framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screws including bending and welding angles as necessary, gusset plates, riveting, etc n exc 10 kg each brackets confirming to Fe 290. Grade-E- 165 complete all as specified. (upto 04 storey of building). Note: (brackets over 10kg each to be measured under structural steel).
ditto all as per item No. 12.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with J hook & washers complete all as specified and as directed.(upto 04 storey of building).
ditto all as per item No. 12.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply & fixing in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples and directed complete all as specified and as directed by Engineer-in-charge. (upto any height of building).
S& fix in repair Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in cup board for short area including piano hinges,wooden knob and magnetic katch complete all as specified and as directed by Engineer-in-charge. (upto any height of building).
Supplying and fixing in repairs 1.25mm thick steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and as directed.
Repairs to steel window not exc 2 sqm in each by replacing damaged hinges, glazing bars, portions of frame, steel handles, Peg stays etc including necessary welding and easing of shutter with one coat of synthetic enamel paint to complete window all as specified and directed. (upto 12 storey of building).
ditto all as per item No. 12.17 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 12.17 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
SCHEDULE 'A' PART-II (ELECTRICAL WORKS)
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc and making good distrubed surfaces of walls, floors, etc.and removing from site, complete all as specified and as directed.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sq mm with proper colour coding and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / exhaust fan controlled by one switch complete including cutting, chasing the surface on wall and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge.
All as per item No. 13.02 here-in-before above but in existing conduit ,complete all as specified and directed by Engr- in-charge. Note for Item No 13.02 & 13.03: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board for replacement of wiring on roof/ceiling/chases shall not be cut, short piece of PVC casing capping shall be used for replacement of wiring.
All as per item No. 13.02 here-in-before but of one bell point controlled by one bell push with cables of 1.5 sqmm size, complete all as specified and as directed.
All as per item No. 13.02 here-in-before but 3 pin 5 amps socket out let point with the same board with other switches with cables of 1.5 sqmm size, complete all as specified and as directed.
All as per item No. 13.02 here-in-before but for one 5 amp socket on independent board with cables of 1.5 sqmm size, complete all as specified and as directed.
All as per item No. 13.02 here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board complete all as specified and directed by engineer incharge.
All as per item No. 13.02 here-in-before but for one light point controlled by two switches two ways, complete all as specified and as directed.
Supply and fixing sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 2 modules, complete all as specified and as directed.
All as per item No. 13.09 here-in-before above but for 2 module
All as per item No. 13.09 here-in-before above but for 3 module.
All as per item No. 13.09 here-in-before above but for 4 module
All as per item No. 13.09 here-in-before above but for 6 module.
All as per item No. 13.09 here-in-before above but for 8 module.
Supply and fixing modular cover plate with frame for fixing of modular switches/sockets complete for 1 modules ( Note:- switch and sockets will be measured and paid separately).
All as per item No. 13.15 here-in-before above but for 2 module.
All as per item No. 13.15 here-in-before above but for 3 module.
All as per item No. 13.15 here-in-before above but for 4 module.
All as per item No. 13.15 here-in-before above but for 6 module.
All as per item No. 13.15 here-in-before above but for 8 module.
Supply and fixing switch modular type 6 Amps 230V AC complete one way, complete all as specified and as directed.
Supply and fixing switch modular type 6 Amps 230V AC complete two way, complete all as specified and as directed.
Supply and fixing modular bell push 5 Amps., complete all as specified and as directed.
Supply and fixing modular socket outlet 3 pin 5 Amps 230 volts, complete all as specified and as directed.
Supply and fixing modular socket outlet multipurpose 3 pin 15 Amps and one 5 Amps controlled by one switch, complete all as specified and as directed.
Supply and fixing modular type switch, one way 16 Amps, 1 module, complete all as specified and as directed.
Supply and fixing modular electronic step type fan regulator 230 volt , 2 module complete all as specified and as directed.
Supply and fixing polycorbonate /PVC ceiling rose of size 65x50mm single phase complete all as specified and as directed.
Supply and fixing call bell, musical AC 230 volt single pole. complete all as specified and as directed.
Supply and fix surface & wall mounted LED batten 4 feets with 1x20 w indoor decorative luminaries with and including Electronic driver and 1 x20 Watt LED lamp, pre-wired including necessary electric connection copper flexible PVC cable of 0.50 sq. mm three core not more than one metre in length from ceiling rose/connector to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2400 Lumens,Voltage Range: 140 to 270 Volts, Continuous operation of 2 Hours at 320 Volts. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy of Luminaire (lumens/Watt): - Not less than 120 lumens/watt (ix) Colour temperature: - Not less than 5700 degree K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2.5 KV (xv) Heat sink: - As per OEM's design.
Supply and fix surface & wall mounted LED batten 2 feets with 1x10 w indoor decorative luminaries with and including Electronic driver and 1 x10 Watt LED lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 sq. mm three core not more than one metre in length from ceiling rose/connector to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1200 Lumens,Voltage Range: 140 to 270 Volts, Continuous operation of 2 Hours at 320 Volts. (ii) Housing: - Aluminium Extruded body.(iii) IP rating: -Minimum IP 20 (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy of Luminaire (lumens/Watt): - Not less than 120 lumens/watt (ix) Colour temperature: - Not less than 5700 degree K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design.
Supply and fixing AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking down complete all as specified and as directed..
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
Supply and fixing MCB TPN DB made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
Supply and fixing sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified.
Supply and fixing MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
Supply and fixing MCB, single pole, 240Volts, of capacity 6-32 Amp, breaking capacity 10KA,'C' curve complete all as specified and as directed.
Supply and fixing MCB DP 63 amps 240 volts 10KA breaking capacity complete all as specified and as directed.
Supply and fixing Isolator 63 Amps 415 Volts FP with rapturing capacity 10KA complete all as specified and as directed.
Taking down aluminimum sub mainwiring alongwith damaged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complete all as specified and as directed.
S&F Sub main wiring with proper colour coading two run of single core PVC insulated unsheathed stranded copper conductor FRLS of size 10 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 10 Sqmm as earth lead drawing into rigid non metalic PVC conduit of suitable size ISI marked, complete all as specified and as directed. Note: (1) Two run of 10 sqmm cable and one run of 10 sqmm cable will be measured as single length.(From TPN to meters). (2) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (3) For replacement of wiring on roof/ceiling/chases shall not be cut, short piece of PVC casing capping shall be used for replacement of wiring.
All as per item No. 13.41 here-in-before but with two run of single core 6 sqmm and one run of 6 sqmm cable , complete all as specified and as directed. Note: (1) Two run of 6 sqmm cable and one run of 6 sqmm cable will be measured as single length (From Meters to DBs). (2) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (3) For replacement of wiring on roof/ceiling/chases shall not be cut, short piece of PVC casing capping shall be used for replacement of wiring.
All as per item No. 13.41 here-in-before but with two run of single core 4 sqmm and one run of 4 sqmm cable complete all as specified and as directed.(for two nos of ACs at each qtr). Note: (1) Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length . (2) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (3) For replacement of wiring on roof/ceiling/chases shall not be cut, short piece of PVC casing capping shall be used for replacement of wiring.
Supply & fixing on wall of building incl clamps for XLPE insulated PVC sheathed armoured LT 1100 volt grade aluminimum conductor cable of size 25 Sqmm 3.5 core complete all as specified and directed.
Supply and fixing 5 star rated water heater(geyser) storage type Energy efficient SPHP Technology inner container ,A.C single phase 230 Volt,50 Hz of storage capacity 25 ltrs Vertical type including necessary inlet and outlet connections to geyser (for cold & hot water connections) with steel grip, chromium plated PVC connections 600 mm long in length (as per site requirments) (outlet PVC connections should be capable to withstand the designated temperature of geyser), complete connecting upwater heater , including fixing of hold fast 10 cm long including washers complete all as specified & directed. Note : Old UNSV Geysers will be deposited to E/M store for further disposal under departmental arrangements.
Supply and fixing Ceiling fan with BLDC motor with remote control, 5 speed, 30 to 35 W, 1200mm, voltage range 90V to 300 Volts , 50 Hz single phase, white colour , complete all as specified & directed . Note : Old UNSV ceiling fans taking down and will be deposited to E/M store for further disposal under departmental arrangements.
Supply and fixing Exhaust fan 300 mm, 230 volts 50 Hz single phase including louvres & shutters nuts and bolts complete all as specified & directed. Note : Old UNSV exhaust fans taking down and will be deposited to E/M store for further disposal under departmental arrangements.
Supply and fixing Exhaust fan 250 mm, with polycorbonate blades 230 volts 50 Hz single phase including louvres & shutters nuts and bolts complete all as specified & directed. Note : Old UNSV exhaust fans taking down and will be deposited to E/M store for further disposal under departmental arrangements.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unsv from earth complete all as specified and as directed.
Dismantling , old unserviceable Aluminium strip and GI strip complete all as specified & directed.
Supply and fixing single pointed air termination rod of 12mm dia and 600mm long including taking down old one complete all as specified and as directed.
Supply and fixing single aluminium strip 25x3.15 mm complete with saddles and fixing screws for roof conductor/down conductors all as specified. Including pocelain insulator complete all as specified and as directed by the Engr-in-Charge. Note: Rate quoted shall not be deemed inclusive of scaffolding, the existing scaffolding shall be used to execute this Item.
Supply and fixing earth continuity conductor 32x6mm GI strip or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc. complete all as specified and as directed by the Engr-in-Charge.
Supply & Laying GI tubing light grade fixing for lightning conductor of 40mm bore including taking down old GI Pipe complete all as specified and as directed by the Engr-in-Charge.
Supply & Laying GI tubing light grade fixing for lightning conductor of 80mm bore including taking down old GI Pipe complete all as specified and as directed by the Engr-in-Charge
Supply and fixing test point terminal Box made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down complete all as specified and as directed by the Engr-in-Charge.
M&L for galvanised stay strands size 7/4mm with all accessories , including taking down old unsv stay strand complete all as specified and as directed by the Engr-in-Charge
S& F Aluminium Armoured Cable of size 6 Sqmm 2 Core PVC insulated including taking down old AL cable completed all as specified and as directed by the Engr-in-Charge
Taking down carefully the exixting LED light batten fitting of any wattage 20/10W and any size by unscrewing from wall/outlet boxes and fixtures and keeping in safe custody for reuse at site and refixing the same after completion of new wiring work in same location and complete all as specified and as directed by the Engr-in-Charge. (Note:- Any breakage/damage of light fitting during taking down /re-fixing shall be make good by the contractor with his own cost).
NARSINGH DEVELOPERS LLP
Hindustan Traders
NIRMAL SALES CORPORATION
DNS CONSTRUCTION COMPANY
surendra infrastructure pvt ltd
KAKALI ENTERPRISE
M P KHAITAN
Allied Construction
BHOWMICK ENTERPRISES INDIA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid