Interlocking of Manned Level Crossing gate having TVU more than 50000 over Jammu Division i.e C-28, C-46, C-24 & C-30 on JAT-PTK Section.
433_Sig_JAT_103_26-27
433_Sig_JAT_103_26-27
Open
6 Months
Jammu, Jammu And Kashmir
₹0
₹4.5 L
3 Jul 2026
3 Jul 2026
10 Jul 2026
A-Drawing & Design Items
Design and supply of the following drawings and office record to the requirement of the Railways This includes alteration at different stages and finally supply of the all drawing including tracings in sets within 30 days from the date of commissioning of the work. This includes the following drawings wherever applicable): (1) Cable lay out plan (Main) (2) Cable layout plan (Tail) (3) Cable matching chart (4) Location Hut drawing(5)Termination chart of end goomties and location hut.(6)Traction bonding plan.(7) Contact Analysis Chart (8) GWR (9) GWRD (10) Indoor and outdoor Wiring diagram for concerned LCs. (11) Any other drawing as found relevant as per site condition /office record including the following: (i) Battery History book (ii) Track Circuiting Register. (iii) Track 1 circuit maintenance Register. (iv) Cable Meggering Register (v) Signal History Register (vi) Lamp Register.(vii) Glued joint/ Block joint Register (viii) Point machine Maintenance Register .(ix) Joint Inspection Register (a) P. Way, (b)Electrical & Signal register (x) Relay Register (xi) Route cancellation Register (xii) Relay Room Key Register (xiii) Emergency Point operation Register. (xiv) Crank Handle Register (xv) Emergency Route Cancellation Register (xvi) Axle counter reset register. Note:(i) All the aforesaid drawings have to be supplied before the proposed work related to the drawing is being taken up and to be approved by the Railway Engineer deputed for the work.(ii) Any drawing submitted for approval of the Railway may be rejected if found unsuitable and the contractor is bound to redraw the same for Railway's approval. (iii) In every case the contractor has to supply two sets of Ferro prints for Railway's approval. (iv) It will be the contractor's responsibility to correct the tracing time to time as required as per site condition.Insp Rep of Sr.DSTE/JAT
Design, Manufacturing & Supply of electrically operated lifting barrier 110V DC as per requirement and as per RDSO Spec.RDSO/SPN/208/2012 Ver.2.0 and Amendment 1 or latest complete set along with pedestal driving and driven mechanism, booms length as per site requirement up to 9.76 mtrs (approx10 mtrs), balancing weight, boom support and motorized boom locking arrangement, circuit controllers, operating panel, Road warning bell,hand generator & crank handle for emergency operation with all accessories complete in all respect. Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier as mentioned in para 10.2 of RDSO/SPN/208/2012 Ver2.0 or latest. (A Set consists of two booms and other accessories as per RDSO's latest Specification).(Inspection: RDSO)
Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5 sq mm) as per IS 694:2010 and RDSO Specn. No. IRS: S- 76/89 (Amnd-3) or latest.(Inspection: Consignee)
Supply of electric fuse complete with fuse block made of PBT for Railway signaling as 3 per IRS-S-75/2006 Rev 2 or latest, fuses non-deteriorating type low voltage, to suit Specn. No. IRS: S- 78/92 or latest, 2 Amp/4 Amp/10 Amp/16 Amp/630 mA fuses in ratio of 30:20:10:20:20. Fuse block shall be suitable for round head type fuses.(Inspection: RDSO for 2 Amp/4 Amp/10 Amp/16 Amp) & ( Inspection Consignee for 630 mA )
Supply of Colour light signal post 4.6 Mtr and ladder 4.5Mtr & bases as per tech. spec. IRS-S-6-81, Rev-3 or latest . Inspection: RITES
Supply of Colour light signal post 3.6 mtr and ladder 3.5 Mtr. & bases as per tech. spec. IRS-S-6-81, Rev-3 or latest. Inspection: RITES
Supply of 2 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23003 A/M (Adv), Alt-9 or latest . Specification no. IRS:S-26/64 Rev 1 or latest. Inspection: RITES
Supply of 3/4 Aspect colour light signal unit complete with-out holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23001 A/M (Adv), Alt-9 or latest respectively. Specification no. IRS:S-26/64 Rev 1 or latest.Inspection: RITES
Supply of Key lock relay, type TMA 24V DC with2F/2B contacts configuration with 8 different wards combination as per RDSO spn. No. IRS:S-46, S@45"38@ S-23 and RDSO/SPN/219/2016 ver1.0 with Amendment-1 or latest. Details of ward combination will be provided during execution of work. (Inspection: For bare relay -RDSO, for keylock housing- consignee)
Supply of Relay AC immune, plug in type, style QNA1, DC neutral line 24V DC, 8F/8B 9 contacts, Front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS-931A,IRS S 60/78, IRS S 34/68and IRS-S-23/88 or latest(as applicable). The interlocking code for this unit shall be ABDGH.(Inspection: RDSO)
Supply of Relay plug in type, style AC LED, all aspect AC lamp proving relay unit with in built current transformer types low to release neutral line relay 4F/4B contacts, front & back 10 contacts metal to carbon, shall be suitable for working in series with the 100 V AC,LED signal lamp rated at 15 W confirming to RDSO spec STS/E/ Relays/AC Lit LED signal/09-2002 Amdt1, BRS:941A, IRS-S-34 &IRS-S-23/88 or latest with latest amendments as applicable. The interlocking code for this unit shall be ABDHK type.(Inspection: RDSO)
Supply of apparatus case Large with 'E' type locks and key ward no. 42 and handle as per RDSO Drg.no. RDSO/S-11500.(Inspection: RITES)
Supply of apparatus case steel half with E type lock and key ward no. 42 and handle as per RDSO Drg.no. RDSO/S-11507.(Inspection: Consignee)
Supply of ARA terminal blocks 25 mm center small M-6 terminal madeof PBT as per RDSO drg.no. SA-23741-A (alt-4) & spec. no. IRS-S-75/2006& RDSO/SPN/189/2004Ver. 3.0 (Rev:2) or latest as applicable.(Inspection: RDSO)
Supply of electrical lifting barrier booms of 9.76 meters each as per DRG.RDSO/S- 11600. The material will be as per RDSO Specn. No.RDSO/SPN/208/2012/Ver.2.0 and Amendment 1 or latest.(Inspection: RITES)
Supply of Electronic Timer Relay 24 V DC , 60 Sec as per RDSO Spec. IRS:S 61/2000 (Amend.3) or latest. Inspection-RDSO
Supply of tool kit for JE/SE/SSE for Maintenance as per tech spec. given below: (1) Digital Multi Meter suitable for axle counter ranges 20 Amp AC/DC make protek 506 or similar- 1 no. (2) Digital clamp Multi Meter range up to 100 Amps for AC/DC current make SEW or similar - 1 no. (3) Leather Tool Bag for keeping tool kit -1 no. (4) Plier Sealing with sealing code bit -1 no. (5) Plier Wire Cutting 8" make Taparia or similar -1 no. (6) Nose Plier 4" make Taparia or similar -1 no. (7) Wire 16 Stripper - 1 no. (8) Screw Driver set mutli port type -1 set (9) Track shunt resistance .5 ohm -1 no. (10) Soldering Iron 230V AC/65 watt -1 no. (11) Soldering Iron 230V AC/35 watt with diffrerent type replacement soldering head - 1 no. (12) Soldering Iron 110V AC/35 watt -1 no. (13) Mesuring Tape steel 30 meters - 1 no. (14) Mesuring Tape steel 3 meters - 1 no. (15) Rechargable Torch Superior quality -1 no. (16) File Flat 8" long - 2 nos. (17) File Round smooth 8" long - 2 nos. (18) File Flat B ster red 8" long - 2 nos. (19) Electric Drill Machine Portable 6mm make wolf or similar -1 no. Inspection by Consignee
Supply of 4 conductor dis-connect terminal block for test and measurement 0.8 17 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection: RDSO
Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee
Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee
Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Ver.3.0 or latest. Inspection :Consignee
Supply of Motorized locking, Motor and Motor contactor as spares for ELB as 21 mentioned.-(a) Motorized Locking Complete110 V AC with Limit switch including Dual Limit switch for Boom Lock Proving. New Design = 04 Pair (b) Motor 110 VAC 0.5 HP for pedestal =08 Nos. (c) Motor110 VAC 0.25 HP for locking =08 Nos. (d) Motor Contactor 110 VAC (9 Amp) =20 Nos. (e) Motor Contactor 110 V AC (18 Amp)=20 Nos. Inspection- RITES
Supply of Digital AC/DC low current Clamp meter . Model Metravi Digital AC/DC Leakage Current Clamp Meter 17 mm Blue & Black, 4673 or similar or better (Inspection by Consignee )
Supply of Digital Earth Clamp Tester, Data Storage : 99 reading, Audio - light alarm, Alarm Critical Value Setting Range : (Resistance:1-199O ), Power : 6VDC (4 PCS alkaline dry battery), 23 Working Temp : -20 deg C to 55 deg C ;10% RH-90%RH, LCD Screen : 4-bit LCD digital display, Jaw Size : Long-jaw 65mmX32mm, Protection Level : Double insulation, CAT III 150V, CE, Structure : Clamp CT, Measured Current Frequency : 50/60hz automatically. Make/Brand: RISHABH or Similar. (Inspection by Consignee )
Supply of SPD Life tester for testing of all Make type of SPD, designed for on-site 24 testing of surge protective devices (SPD). It allows checking and indicating the health status of GDT/MOV based SPD of voltage range up to 1000V. It shall indicate the status of SPD by measuring its electrical parameter (varistor voltage ,leakage current & Spark over Voltage. Make- JMV,DHEN,CITEL or Similar (Inspection by Consignee )
Supply of Color LCD/LED Thermal imager 14000 pixel, similar to Model: Sonel KT 128 or similar or better , Brand : Sonel or similar or better Inspection : Consignee
C-Supply & Execution Items
Supply, Installation, Testing & Commissioning of Sliding Boom Barrier complete with all accessories. Inspection -RITES for Supply Portion
Supply, installation, testing and commissioning of Remote terminal Unit (RTU) 64 2 digital input and 16 analog input for LC gates as per RDSO specification no. IRS S 99/2006 amendment 3 or latest. Along with accessories with contactors own wiring & fixing material (Inspection: RDSO)
Fabrication, Supply and fixing of retro reflective P/G/C markers with complete fittings 3 as per approved Drg. No. NR/S&T/CON/6.2/97. All material required for the job such as MS sheet, MS angle. Nut and bolts will be supplied by the Contractor. The P and G markers shall be as per Drg. No. S 23456(Adv) & SA 23477(Adv) respectively. Inspection: Site Engineer
Supply, installation and commissioning of maintenance free separate earthing kit as per RDSO spcn. no. RDSO/SPN/197 Ver. 1.0 or latest and drg. no. SDO/RDSO/E&B/001 dated 19.09.2008 or latest. Basic earthing kit-1 set consisting of [a] The earth electrode shall be UL listed and of minimum 17.0mm diameter and minimum 3 Meter long and minimum copper bonding 4 thickness shall be of 250 microns of 99.9% electrolyte grade copper.-01 nos. [b] Earth enhanching compound RDSO approved in sealed bags of 10 kgs each-03 nos. minimum [c] Copper bus bar of Size 200 mm X 25 mm X 6mm-01 No. [d] MEEB 300mm X 25mm X 6mm-01 no. [e] 35 sq. mm. copper cable to connect earth electrode to MEEB- 15 mtrs. approx. and all other materials and cables required for installation. Work to be carried out in supervision of Site engineer. Commission certificate to be given by OEM. (Material Inspection: RDSO)
Supply and installation of earth electrodes pipe of 3mtrs length and 50 mm dia. pointed on lower endby tapering for a length of 150 mm and connectingwith lightening arrester orsignaling gears as per std. Practice. The item includes digging of pit in earth, 3 Mtrs. Deep and fixing earth electrode pipe in it. Earth pipe shall be buried in the ground to the length of 2.7 mtrs. after welding 6 SWG wireat lower end and fixing through nut and bolt at top. Casting of cement of Cement concrete enclosures as per drg. No.NR/S&T/CON/6.4/97 orlatest if any. The soil treatment 5 shall be done as per std. practice. The item includes provision of earth lead wires/mild steel flat and soldering of lead wires. The other end of the earth wire/mild steel flat to be connected to block instrument mild steel flat, cable sheath ofpower equipment,apparatus case, relay racks, other equipments as per the instruction of Engineer at site & IRSEM. Complete materials such as earth electrodes as perdrg. No.NR/S&T/CON/6.3/97,cement, wiring material,soldering material, mildsteel flat, soldering o lead wires etc. to be supplied by the contractor. The earthing lead shall be mild steel flat of size 35mmX6mm. In case conductor isburied underground, it shall be protected from corrosion by application of suitable anti-corrosive paint. (Material inspection: RITES)
Supply, installation & wiring of Earth leakage detector (12 Channel) Level-1 for monitoring different AC and DC, supplies including all accessories as per . specfication no. RDSO/SPN/256/2025 Ver: 2.0 or latest Inspection: RDSO
Boring & Trenchless cabling along with supply and insertion of Double walled corrugated HDPE pipe as per RDSO spec.no.RDSO/SPN/SPN/204/2011 ver. 1.1 and amendment 1 or 7 latest with 90mm outside dia. and 67mm minimum inside dia. in the bore for laying of Signaling/Telecom/Power cables under the track/road. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring 2. Spacers 3. Tees 4. Bend 5. End cap etc. to be supplied along with the pipe. Work at site shall be inspected by Site engineer & DWC HDPE pipe and associated material to be inspected by RITES.
Supply and laying of 2nd class well burnt bricks in trench breadth wise over the top of cable throughout i.e. 8 bricks in one meter over whole of the cables. Bricks shall be got staked and got inspected by Rly. Representative before laying. (Inspection by Consignee).
Supply and installation of RFID electronic marker for S&T underground cable wlth 9 progammble memory for saving the user specific data inside the RFID electronic marker memory chip,later recordable by electronic marker locator during locating(10 cm diameter with floating coil to keep detection circuit always Horizontal for better detection) which can be buried to depth of 5 ft Placing in trench. Inspection :Rites
Supply and placing of trunking and capping (RCC duct) of 300 mm width as per DRG. NO.SDO/Cable laying/007/(Annexure-10) as detailed in document no. RDSO/SI/G/2010 Ver.1.1 or latest on guidelines on signaling cable laying.
Supply and fixing of G.I Pipe with 76.6 mm maximum and 75.3 mm minimum outside 11 dia. and 3.6 mm thickness, as per spcn. no. IS-1239 (part-I) or latest if any, medium grade, perforated at a distance of 20 cm or less of required length at culverts/bridges/along the cuttings, suitably concreted at both ends as per drg. no. NR/S&T/CON/1.4/97. G.I. clamps of M. S. flats bolts and nuts to be supplied by the contractor. G.I. pipe and other associated material to be inspected by Consignee. Work at site will be inspected by Site Engineer.
Fabrication & Supply of domino type operating cum indication panel for way side station of Minimum 12 x 7 exchangeable units of size 54 x 34 mm (Siemens panel size) and cover plates with Tag Blocks / terminals, wires, angle irons etc. depicting the yard layout with signals, 12 points, track circuits, operating / emergency push buttons, counters, SM's key housed in a steel metal cabinet as per approved panel diagram and RDSO spec. no. RDSO/SPN/186/2004 or latest. This also includes supply and fixing acrylic sheet on panel. LEDs (24VDC) to be provided as per direction of Engineer. Panel shall be supplied with complete soldering. Size of the panel should be such, so as to accommodate one additional line on either side.( Inspection : Consignee)
Supply & installation of external modem for provision of T-networking of data logger with LC gate with necessary accessories. Inspection - Consignee
Supply fixing and wiring of Fuse Auto Changeover System (FACS main system) as per RDSO/SPN/209/2012 Rev. 2.0 with latest amendments. One automatic changeover unit comprise 32 nos of external Non Deteriorating Type or 'G' type fuses of various Ampere Rating, working voltage- 14 24 VDC which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Installation , wiring, Testing and commissioning of Fuse Alarm System,it consists of fixing of modules of fuse alarm system on existing relay rack, wiring from existing fuses to modules, soldering, lacing etc. working to be executed without affecting the functioning of the existing Circuits/Gears and the work shall be supplied by the contractor. Inspection by- RDSO for supply portion.
Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg. No. NR/S&T/CON/4-3/97A) made of angle iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly 15 galvanised, descriptions strips to accommodate Plug-in-type relays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts & nuts, washers, insulators, shoe, angle irons, flats, L-bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection by Site Engineer.
Fabrication, supply and fixing of cable termination board of size 2200 mm x 900 mm as per Drg. No. NR/S&T/CON/4-1/97A made of angel iron size 40 mm x 40 mm x 5 mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago 16 connectors & fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx4cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, Lbolts, Catenary wires & cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISI mark paints. Inspection :Site Engineer
Supply, Installation, Testing & Commissioning of Microprocessor based Networkable analog Addressable, and modular type of Fire Alarm Control Panel with display with 2 loop 17 expandable upto four loop , power supply and battery back up as per RDSO/SPN/217/2021 ver 3.0 or latest , including. GSM module-01 No for sending SMS to configured mobile number and relay module-02 Nos for connecting to datalogger for remote monitoring. The panel should support sufficient devices of both detectors and modules in a single line circuit. (Inspection By RDSO)
Supply, Installation, Testing & Commissioning of Addressable heat and smoke Multi sensor. As per RDSO specification no RDSO/SPN/217/2021 Ver 3.0 or latest. (Inspection - RDSO)
Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with in built short circuit fault isolator.( As per RDSO specification no RDSO/SPN/217/2021 Ver 3.0 or latest.) (Inspection By RDSO)
Supply, installation, testing and commissioning of analog Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/SPN/ 217/ 2021 ver 3.0 or latest. (Inspection By RDSO)
Supply, installation, testing and commissioning of LHS interface module for LHS cable connectivity to control panel as per RDSO Specification No. RDSO/ SPN/217/ 2021 ver 3.0 or latest. (Inspection By Consignee)
Supply, Installation, Testing &Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base in built fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/217/ 2021 ver 3.0 or latest. Inspection:RDSO
Supply, Installation, Testing & Commissioning of FRLS unarmoured/armoured cable(2Cx1.5sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/217/2021 ver 3.0 or latest Inspection:RDSO
Supply, Installation, Testing & Commissioning of Aspiration systems with single pipe slot along with required module and power supply interfacing module etc. as per RDSO specification no RDSO/SPN/217/2021 Ver 3.0 or latest.(Inspection By RDSO)
Supply, Installation, Testing & Commissioning CPVC Pipe and all other associated fittings as per RDSO/SPN/217/2021 Ver 3.0 or latest.(Inspection By RDSO)
Supply, Installation, Testing & Commissioning of hooter cum strobe including its control module as per RDSO Specification NO RDSO/SPN/217/2021 Ver 3.0 or latest. Insp. BY-RDSO
D-Execution Items
Foundation, Installation, testing & commissioning of Electric lifting barrier complete with panel, motor, booms, weights, warning bells hooters etc. Key chain interlocking along with 1 electric lever locks including casting of foundation for gate machines, installation & wiring of hooters to make the system as per approved diagrams/plans& as per instruction of site engineer. This also includes fixing of E Type lock, both lifting barriers along with boom locking arrangements, fixing &wiring of lever lock, cabling, power supply connection & wiring with complete outdoor work asper approved drawing, wiring etc. (Inspection: Site Engineer)
Casting, concreting and curing of foundation for main signal of size 2 (1041mmx1041mm)at bottom and (711mmx711mm) at top and 1750mm deep as per approved Drg. no. NR/S&T/CON/2.1/97 all material such as anchor bolts, cement, coarse sand aggregate to be supplied by contractor. Inspection: Site Engineer.
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current 3 regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc. for the following: (a) Installation, erection, wiring of 2 aspect color light signal. Inspection: Site Engineer
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal 4 unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 3/4 aspect color light signal. N Inspection: Site Engineer
Casting, concreting and curing of foundation and erection of App. Cases (Single) as 5 per drg. No.NR/S&T/CON/2.7/97. All materials such as cement,sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railways. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination.(Inspection: Site Engineer)
Preparation & fixing of Bakelite hylum sheet 910x 800 x 6mm and teakwood shelf 900mm x 450mm x 25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx 25mm x 3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal shelf type 'Q' series relays and other type relays onsquare bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom.This will include opening, pasting and jamming armour of each cable in 6 the hole drilled separately for each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100 mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non-deteriorating type HRC fuses, bases, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the railways. Preparation of App. Case single involving wiring of relays. (Inspection: Site Engineer)
Casting, concreting and curing of foundation and erecting of App. Cases half as per 7 drg. no.NR/S&T/CON/2.8/97 or latest. All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. Contractor is required to execute all types of repair works of foundations if required during insertion of cable for termination.(All concrete work must be ratio of cement, coarses and aggregate1:3:6).(Inspection: Site Engineer)
Preparation of App. Case half not involving wiring of relays which includes following- (i) Preparation and fixing of Bakelite hylum sheet 450x800x6mm and teak wooden shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of25mm/25mm/3mm.Angle iron frame will be fixed in location box secured by nuts & bolts.(ii) Fixing of fuse ARA terminal, shelf type Q series relays and othertype of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank 8 provided at the bottom. This will include opening, twisting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and of cable entry points on location boxes, location nuts JB's relays room battery/room to be closed with suitable masonry work covered with sand & plastering. (iii) Wiring description for terminal,drawing of circuits inside app. Case. Painting from outside as well inside with RED oxide aluminum paint is covered separately. Size of lettering as per instructions of Engr. at site. (iv )All material including teak wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS spec. Non deteriorating type HRC fuses and bases nuts and bolts and other items shall be supply by the contractor. Relays, ARA terminals only shall be supplied by the Railways. (Inspection: Site Engineer)
Earth work around location boxes, signals and other signaling structures etc. wherever necessary including 50 m lead and 1.5 m lift by excavation. The lead be measured from 9 the center of gravity of excavation to the center of filling and the lift, from means ground level. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. (Inspection: Site Engineer)
Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and 10 aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement, sand ratio. It also includes excavation of earth as required at site and as per instruction of site engineer. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. cement, coarse sand and aggregate 25mm are to be supplied by the contractor. (Inspection: Site Engineer)
Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material required including indoor cables and wires of 1x1,1x0.6, 3/0.29, 16/0.2,40x0.6, 40x1, 60x0.6,60x1 dia. of copper conductor as per NR practice conforming to IRS specifications, resistance and condensers are to be supplied by the contractor. This also includes wiring from CT rack to tag 11 block, tag block to relays & wiring off use etc. required in connection with relay room /relay hut wiring and soldering, dressing, bunching, lacing, fixing of relay bases etc. and provision of LED indication of vital relays in relay room and provision of potential free contacts for relays on tag block for data logger as per instruction of site Engineer. This also includes dressing, bunching, lacing and fixing of relay bases. Indoor cable/wires shall be as per Spec. No. IRS-S76/89 (Amd. 3 or latest). (Inspection: Site Engineer)
Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/CON/1.1/97-A (attached with tender) so as not to form a drain 0.3 Mtrs. 12 Wide & 1 Mtr. Deep on both side of the station along side the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser depth due to site conditions shall be paid proportionately after obtaining prior approval from not below than JAG officer.(Inspection: Site Engineer)
Excavating and refilling of trench in Rocky soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97-A1 so as not to form a drain 0.3 Mtrs. Wide & 0.5 13 Mtr. Deep on both side of the station alongside the track .This includes 50 mm thick concreting work through out in 1:3:6 ratio. All concreting material to be supplied by the contractor. It shall conform to the safe distance as per signalling and cable plan It also includes clearance of routes of trees & bushes.
Excavating and refilling of trench 0.3 Mtr. Wide and 0.8 Mtr. Deep on 14 pitched/Stone/bricks paved surface, road crossing/platform etc. and restoring the surface to its original conditions. Lesser depth of the trench is to be paid proportionately. (Inspection: Engg representative)
Laying of signaling/telecom/power cables by unwinding cables from drums of 15 different sizes as per drg.no. NR/S&T/CON/1.1/97and as per cable route plan approved by the railways. Meggering of cable before and after its laying of all types of cables. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways.(Inspection: Site engineer)
Installation of KLCR & its box in location boxes/gate lodges, supply & installation of 16 heavy duty push button, LED indicator on MS sheet of 4.5 mm thick inside location box/gate lodges for crank handle locking. The work includes fixing & wiring of magneto telephones, wiring of relays, push buttons and termination of tail cable as per instruction of site engineer. All material except KLCR & its box and magneto telephone is to be supplied by the contractor. (Inspection:Site Engineer)
Bricks work with well burnt bricks in foundation and plinths with cement and sand mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Site Engineer) 1826852.9
Modification/Alteration in interface circuit, application logic, VDU software and wiring, 18 installation, testing (including FAT,SAT) and commissioning of existing Electronic Interlocking System (Make: M/s KYOSAN) for interlocking of manned L.C. GatesThis includes all related wiring, relays, card and any other accessories if required for this alteration and modification work of EI at CHNR Station. Required alteration sheets of Drawing and circuits for EI -06 set. (Modification work will be executed as per approved SIP)
Cleaning , Scrapping , Painting and lettering of all newly installed and existing gears 19 by the contractor for existing new level crossing Gates. This includes supply of all painting materials and marking of all the ckt particulars near terminal board/ in apparatus case/ jn. boxes and fuse nos, relay and equipments nomenclatures as per approved terminal chart and provisions of SEM.
Dismantelling of lifting barrier/ gate leaves complete set along with winch, wire rope, boom locking arrangement , all dismantled material to be transported and stacked in the store SSB depot or SSE/Sig/store or any other of northern railways as per consignee. Note:- before dismantling joint survey is to be done with the site engr. and report to be submitted to the site engr. (1 job= 1 LC).
Loading, Leading & unloading of materials from store to another store outside of division as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SpeicalconditionsofworkSignal.pdf
ATTACHMENT
IRGCC2022ACS7-10.pdf
ATTACHMENT
StandardTenderDocument2022andcorrection.pdf Standard Tender Documents with correction
ATTACHMENT
IRGCCApril2022andcorrectionSlip.pdf
ATTACHMENT
StandardTenderDocument2022andcorrection.pdf
ATTACHMENT
Download all tender documents and submit your bid