Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.7 L+₹1.1 L (4.77%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹27.9 L+₹5.3 L (23.6%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹28.5 L+₹5.9 L (26.1%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Other Than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended due to not enlisted in category b(ii) |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Nov 2021, 6:00 pmClosed
CWE 138 WE
HQ 138 WE C/o 56 APO
REPAIR REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INCL REPLACEMENT OF OVER HEAD CONDUCTOR UG CABLE LT PANEL AND OTHER ALLIED WORKS OF SECTOR A OLD AND NEW COPRS AREA UNDER AGE E/M-II OF GE 865 AT LEH
2021_MES_481206_1
138WE/L-72/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE 865 EWS
₹70,000
Yes
3 Dec 2021
12 Oct 2021
16 Nov 2021
12 Oct 2021
9 Nov 2021
26 Oct 2021
Amount
Dismantling of ACSR conductors complete of any size and type from exisiting site all as directed by Engr -in- Charge.
M&L for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers,etc complete all as specified.
Dismantling of insulator complete of any size and type from exisiting site all as directed by Engr -in- Charge.
M&L for Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers insulator bolts, washers and nuts of height 100 mm, max dia 115 mm,section of straps 31x5 mm,dia of bolts 14 mm all as specified and directed by Engr-in-charge.
M&L for Pin insulator porcelain white, brown or green 100 mm height, 65 mm dia for 1100 volts grade complete all as specified.
Dismantling cross-arms of M.S Channel or angle sections etc complete of any size and type from exisiting site all as directed by Engr -in- Charge.
M&L for cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-0-310/ Fe-0-410 incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified.
Dismantling of stay assembly complete of any size and type from exisiting site all as directed by Engr -in- Charge.
M&L for stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as spd and directed.
M&L for replacement of LT PVC Separator and Spacer Sparell with all accessories complete all as specified and directed by Engr-In-Charge. Make : As per Sample ISI Marked.
M&L for Painting to exposed surfaces of LT Steel tubular pole with one coat of synthetic enamel paint up to 1 mtr height from ground level with 3 strip of yellow colour synthetic enamel paint and two strip of white synthetic paint (as per the existing colour), including preparation of old painted surface,Complete all as specified and directed by engr-in charge.
M&L for Painting to exposed surfaces of HT Steel tubular pole with one coat of synthetic enamel paint up to 1 mtr height from ground level with 3 strip of yellow colour synthetic enamel paint and two strip of white synthetic paint (as per the existing colour), including preparation of old painted surface,Complete all as specified and directed by engr-in charge.
Disconnecting and Taking out old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches/poles /pipes, for replacement all as directed by Engr in charge
Supply and lay PVC insulated, heavy duty, LT XLPE galvanised steel strip or wire armoured electric power cable of size 25Sqmm x 4 core with stranded aluminium conductor 1100 Volts grade, jointed with cable glands, lugs etc., laid in trenches/drawn through pipe, with and including taking down old unserviceable cable, complete all as specified and directed
All as per item srl No 14 above but of size 50 sqmm 3.5 core nominal cross section complete, 1100 volts.
All as per item srl No 14 above but of size 70 sqmm 3.5 core nominal cross section complete, 1100 volts.
All as per item No 14 above But size of 95 Sqmm 3.5 core nominal cross section complete, 1100 volts.
All as per item No 14 above But size of 120 Sqmm 3.5 core nominal cross section complete, 1100 volts.
All as per item No 14 above But size of 150 Sqmm 3.5 core nominal cross section complete, 1100 volts.
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation etc in Hard and Dence soil & getting out for laying of cable complete all as specified & directed.
Returning filling in including spreading leveling watering & well ramming in layers n exc. 25cm thick.
Removing of surplus excavated soil to a distance n.exe 50 Mtr and depositing where directed at a level n.exe 1.5 mtr above the starting point complete all as specified.
Material and labour for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose
Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm all as specified and directed.
Taking down old unserviceable GI pipe light grade of any size complete all as specified and directed
S&F GI tubing 40mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc., including necessary road cutting and making good with PCC (1:2:4) type B-1, using 20mm graded stone aggregate, in repairs, complete all as directed.
S&F GI tubing 50mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc., including necessary road cutting and making good with PCC (1:2:4) type B-1, using 20mm graded stone aggregate, in repairs, complete all as directed.
S&F GI tubing 80mm dia "light grade" with all fittings, laid in trenches, fixed on pole/under road crossing or passing through gutters etc., including necessary road cutting and making good with PCC (1:2:4) type B-1, using 20mm graded stone aggregate, in repairs, complete all as directed.
Taking Down old unserviceable LT Panel board any type complete all as directed.
Supply, install , test & commissioning of LT panel board, outdoor cubical type, floor/wall mounted on MS angle iron frame of size 50 x 50 x 6 mm thick, made out of 3.15 mm thick CRCA sheet powder coated for load bearing members for double doors both side openable and covers, Suitable for 3 phase 4 wire 50 cycle 500 Volts system weather and vermin proof, including internal wiring with suitable size copper cable, heat shrinkable sleeves, chromium plated brass cable glands, lugs, 300Amps Busbar and necessary excavation earth work, PCC grouting etc.. to comprising of the following, with and including taking down old unserviceable burned out/damaged panel, incl removing of old cable connection after installation of LT Panel with reconnection of old cable complete all as directed by Engineer -in- Charge . a) MCCB 250 Amp, 4 Pole, 35 KA, 415V, 50Hz (Main Incomming ) 01 No b) MCCB 100Amps , 3 Pole, 16 KA, 415V, 50 Hz (Outgoing) 01 No c) MCCB 63Amps 3 Pole, 16 kA 415V, 50Hz (Outgoing) 04 Nos d) Volt meter, Ampere meter, Indicator Lamp complete - 01 Set
Supply, install , test & commissioning of LT panel board, outdoor cubical type, floor/wall mounted on MS angle iron frame of size 50 x 50 x 6 mm thick, made out of 3.15 mm thick CRCA sheet powder coated for load bearing members for double doors both side openable and covers, Suitable for 3 phase 4 wire 50 cycle 500 Volts system weather and vermin proof, including internal wiring with suitable size copper cable, heat shrinkable sleeves, chromium plated brass cable glands, lugs, 250Amps Busbar and necessary excavation earth work, PCC grouting etc.. to comprising of the following, with and including taking down old unserviceable burned out/damaged panel, incl removing of old cable connection after installation of LT Panel with reconnection of old cable complete all as directed by Engineer -in- Charge . a) MCCB 160 Amp, 4 Pole, 35 KA, 415V, 50Hz (Main Incomming ) 01 No b) MCCB 100Amps , 3 Pole, 16 KA, 415V, 50 Hz (Outgoing) 01 No c) MCCB 63Amps 3 Pole, 16 kA 415V, 50Hz (Outgoing) 03 Nos d) Volt meter, Ampere meter, Indicator Lamp complete - 01 Set
Taking Down old unserviceable GI Earthing with complete accessories complete all as specified and directed By Engr-In-Charge.
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 32X6 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed Note- (i) earth resistance not more than 1.0 OHMS.Writing of details on the surface of the pit with paint. (ii) In case earth resistance more than 1.0 ohms, the contractor will re earthing at no extra cost. (iii) On testing, if the earth resistance less than specified is not obtained, earthing will be regenerated at NO EXTRA COST till the desired earth resistance is obtained.
M/S BALI CONSTRUCTIONS
M.S Sharma Enterprises
R B TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .