| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹39.5 L+₹2.4 L (6.48%)Rejected-Finance GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.1 L+₹10.0 L (26.9%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Not admitted for opening Fin bid due to not enlisted in appropriate category | |
| 5 | Not Admitted-Fee/PreQual/Technical AZARA PO KAMRUP DIST GUWAHATI 781 015 ASSAM | KAMRUP METRO | ASSAM | 781015 | - | Not Admitted-Fee/PreQual/Technical Others-Not admitted for opening Fin bid due to not enlisted in appropriate category |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
27 Feb 2025, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Repair / Maint of summer cooling appliances (water cooler, refrigerator and other connected works) under GE (AF) Borjhar.
2025_MES_696586_1
8474/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category c(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
GE (AF) Borjhar
₹70,000
25 Jun 2025
5 Feb 2025
1 Mar 2025
5 Feb 2025
27 Feb 2025
19 Feb 2025
Amount
AIR CONDITIONER - WINDOW TYPE/SPLIT TYPE
M& L for Servicing to Window type Air conditioner of various capacities of different makes (1 TR to 2 TR) by cleaning with Jet water pressure pump for condensing coil and filter with mild cleaner, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge.
M& L for Servicing to Split type Air conditioner of various capacities of different makes (1TR to 2TR) by cleaning with Jet water pressure pump for condensing coil and filter with mild cleanser, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge.
M& L for Servicing to Split /Cassete/Tower Type Air conditioner of various capacities of different makes (3TR) by cleaning with Jet water Pump for condensing coil and filter with mild cleanser, checking gas pressure/ leakage & rectification of minor faults if any all as specified & directed by Engineer-in- Charge.
Note: (a) Sl No 2.00 to 4.00 will be cleaning with water and Jet water pump and take the signature from the user and submit the office for records. (b) If gas pressur found less than permissible pressur the contractor should insure to fill the gas and maintain the gas presuure as per requirement for achiveining desired cooling level. (c) If required battery or any other minor parts for remote to be replaced and cost for the same shall be included in the rate quoted.
S&F indoor unit of split type AC 1.5 Ton capacity after disconnection of old unserviceable indoor unit of Split AC (1.5 TR cap) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engineer-in-Charge. Make : As per approved list of Make/ as per site requirement.
S&F indoor unit of split type AC 2.0 Ton capacity after disconnection of old unserviceable indoor unit of Split AC (2.0 TR cap) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and as directed Engineer-in-Charge. Make : As per approved list of Make/ as per site requirement.
Disconnecting and removing unserviceable sealed compressor of Split AC (1.5 TR cap Inverter type) and replaced with new hermatically sealed compressor of existing make & model including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing unserviceable sealed compressor of Split AC (2.0 TR cap Inverter type) and replaced with new hermatically sealed compressor of existing make & model including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing unserviceable sealed compressor of Split AC (1.5 TR cap ) and replaced with new hermatically sealed compressor of existing make & model including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing unserviceable sealed compressor of Split AC (2.0 TR cap ) and replaced with new hermatically sealed compressor of existing make & model including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engr-in-Charge.
S&F PCB Set for inverter type (indoor unit+ outdoor) Split AC 1.5/ 2.0/ 3.0 TR capacity complete all asspecified and directed by Engr-in Charge. Make : As per approved list of Make/ as per site requirement. Note: Contractor should supply PCB for the OEM
S&F PCB set (Indoor unit + outdoor unit) for Split AC 1.5/ 2.0/ 3.0 TR capacity complete all asspecified and directed by Engr-in Charge. Make : As per approved list of Make/ as per site requirement. Note: Contractor should supply PCB for the OEM
S&F PCB set for inverter AC Casset type (Indoor unit + outdoor unit) Split AC 1.5/ 2.0/ 3.0 TR capacity complete all as specified and directed by Engr-in Charge. Make : As per approved list of Make/ as per site requirement. Note: Contractor should supply PCB for the OEM
M&L replacement to unserviceable copper capillary tube with new of appropriate size including soldering/ brazing & leak testing for window /split type AC complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of Any type PCB from window/split type AC and repair the same with expert technician including refixing the same afer repair at the existing place etc complete all as specified and directed by Engr-in-charge.
M&L for dismantling to Blower fan motor from window/ split type AC and rewinding to same with super enameled copper wire of appropriate gauge including heat, varnishing & replacement of worn out bearing or bush & capacitor etc complete all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable starting capacitor 100/120 mfd with new one for window/ split type AC complete all as specified and directed by Engr-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
All as per Serial item No. 18.00 here-in-before but 80/ 100 mfd. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable dual run capacitor 55 mfd with new one for window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable dual run capacitor 50+4 mfd with new one for window/ split type AC complete all as specified and directed by Engr-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable dual run capacitor 66+6 mfd with new one for window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable thermostate switch with new suitable for one window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable relay of single phase AC supply with new one suitable for window/ split type AC complete all as specified and directed by Engr-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable over load protector single phase AC with new one suitable for window/ split type AC complete all as specified and directed by Engr-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable air filter with new one suitable for window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&L for replacement to unserviceable fan motor with blades with new fan motor with blades suitable for window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : As per site requirement.
M&L for replacement to unserviceable front grill with new front grill suitable for window AC as per existing size & shape complete all specified and directed by Engr-in-Charge.
Taking out to replacement to worn out & corroded portion of AC's body/ base with new M.S sheet 1.25 mm thick by cutting, bending, welding, machining etc to bring back the original shape including painting with synthetic enamel paint through spray gun machine over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge
S&F replacement to unserviceable contactor accessories single phase AC with new contactor accessories suitable for window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : Siemens or equivallent make approved by MES
S&F replacement to unserviceable electronic control panel board with new control panel suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge.
S&F replacement to unserviceable display circuit suitable for 230 volt, AC with new display circuit suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge.
S&F replacement to unserviceable cordless remote with new remote suitable for machine of 1.5/ 2.0 TR split type AC complete all as specified and directed by Engineer-in-Charge.
Material & Labour for filling gas for 1.5 TR capacity Window/ Split type AC with required quantity refrigerant gas after necessary vacuumization, sealing and leak testing etc. complete all as specified and directed by Engr-in-Charge.
Material & Labour for filling gas for 2.0 TR capacity Window/ Split type AC with required quantity refrigerant gas after necessary vacuumization, sealing and leak testing etc. complete all as specified and directed by Engr-in-Charge.
M&L for replacement to unserviceable capacitor 36 mfd with new capacitor suitable for rotary type compressor of window/ split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement..
M&L for replacement to unserviceable capacitor 45 mfd with new capacitor suitable for rotary type compressor of window /split type AC complete all as specified and directed by Engineer-in-Charge. Make : UNIVERSAL /SARDA / as per site requirement.
M&l for dismantling, shifting, installation & testing of Window/ Split type AC 1.5/ 2.0 TR from one place to another place (with in radius of 2 km) all as specified and directed by Engr-in-Charge.
S&F new copper pipe of dia 5/8 inch insulated by nitrile rubber for suction line including soldering/ brazing of pipe, cleaning the system arresting the leakage (if any), vacuumization etc. complete all as specified and directed by Engineer-in-Charge.
S&F new copper pipe of dia 1/4 inch insulated by nitrile rubber for suction line including soldering/ brazing of pipe, cleaning the system arresting the leakage (if any), vacuumization, etc. complete all as specified and directed by Engineer-in-Charge.
M& L for insulation for copper pipes (liquid and gas line) as per existing type rubber insulating materials suitable for split AC complete as directed by Engr-in Charge.
M&L for replacement of old corroded outdoor type mounting bracket with new heavy duty outdoor type mounting bracket incl fixing the bracket on the wall through fastener bolt etc complete all as specified & directed by Engr-in-Charge.
S&F outdoor unit of split type AC of 1.5 Ton capacity after disconnection of old unserviceable outdoor unit of Split AC (1.5 TR cap) including soldering/ brazing of liquid / gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engineer-in-Charge. Make : As per site requirement
S&F outdoor unit of split type AC of 2.0 Ton capacity after disconnection of old unserviceable outdoor unit of Split AC (2.0 TR cap ) including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engineer-in-Charge. Make : As per site requirement
Supply only refrigerant Gas R-32 to summer cooling appliances all as specified and directed by Engr-in-charge.
Supply only refrigerant Gas R-410A to summer cooling appliances all as specified and directed by Engr-in-charge.
Supply only refrigerant Gas R-22 to summer cooling appliances all as specified and directed by Engr-in-charge. Note: (i) Complaint of Window/ Split AC shall be attended within two hours after intimation to the contractor through SMS/ Whats app/ Telephone by JE E/M or Engr-in-Charge, otherwise an amount of Rs 100/ Hr (beyond two hours) will be deducted from his billing amount and that complain must be rectified within 24 Hours after intimation through SMS/ Whatsapp/ Telephone, otherwise an amount of Rs 200/ Hr (beyond 24 Hours) will be deducted from his billing amount. (ii) Quantity for item 46.00 to 48.00 will be taken on ledger charge by the Deptt. and will be issued to the contractor as per site requirement
WATER COOLER
Disconnecting the water and Electric connection from water cooler of any capacity for repair / serviceing of the same and refixing in its original position/ reconnection all as diercted. Note: (a) All facility water cooler for repair will be attended at site only. (b) Necessary spare/ gas if required for replacement will be measured and paid in respective items.
Supply & Fixing the sealed compressor unit suitable for 40 ltrs/hr capacity for water cooler including gas charging and acessories complete all as specified and directed. Make : Kirloskar/ TECUMSEH
All as per Serial item No 51.00 here-in-above but for 80 ltrs/hrs capacity water coolers. Make : Voltas /Krloskar/ TECUMSEH
All as per Serial item No 51.00 here-in-above but for 120 ltrs/hrs capacity water coolers. Make : kirloskar /TECUMSEH/GODRAJ.
All as per Serial item No 51.00 here-in-above but for 150 ltrs /hrs capacity water coolers. Make : kirloskar/ TECUMSEH
Supply and Fixing Strating capacitor of capacity 80/100 MFD . Make : Universal/ Usha/ Aristo.
Supply and Fixing Strating capacitor of capacity 40/60 MFD. Make : Universal/ Usha/ Aristo.
Supply and Fixing Running Capacitor of capacity 34/36 MFD. Make : Universal/ Usha/ Aristo.
Supply and Fixing Capacitor of capacity 4 MFD. Make : Unuivsrsal/ Usha/ Aristo.
Supply and Fixing Capacitor of capacity 8 MFD Make : Universal/ Usha/ Arosto/ Havells.
Supply and Fixing relay for water cooler of capacity 40/ 80/ 120/ 150 liters per hour type 412. Make : Renetor/ Shriram/ Dun Foss.
Supply and Fixing Thermostat for water cooler capacity 40/ 80/ 120/ 150 liters per hour. Make : Renetor/ shriram/ Godrej/ Danfoss.
Supply and Fixing Blower motor suitable capacity for water cooler 40/ 80/ 120/ 150 liter. Make : Annapurna/ Godrej/ Danfoss.
Supply and Fixing Blower Fan for water cooler 40/ 80/ 120/ 150 liter capacity. Make : Renetor/shriram/Godrej/ Danfoss.
M&L for Re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including replacement of ball bearing, bush, capacitor, rubber base including overhauling, testing and re-fixing complete all as directed
Supply and fixing for bib tap Cast copper alloy 15mm Push type chromium plated inner /outer thread complete all as directed.
Supply and fixing PVC Connection pipe 60 cm long, suitable for fixing to 15 mm dia GI Pipe suitable for Water cooler connetion. Make : Parryware/ prayag
Supply and fixing PVC Float valve with epoxy coated aluminium arm with PVC polythene ball suitable for water coolers.
Supply and fixing PVC polythene ball suiatble to fix to 15mm PVC float valve.
Supply and fixing PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI clamps nuts bolts etc.
M&L for replacement of base plate of water cooler of any cacapcity, made out of 2 mm thick MS sheet and painting with two coats of enamel paint over one coat of red oxide primer complete all as directed .
Supply and fixing for Water cooler door lock CP as per existing with duplicate key. Make : Voltas/ Bluestar/ as per site requirement
Supply and fixing door rubber inner liner (magnetic) suitable for water cooler capacity 40 ltrs.
Supply and fixing door rubber inner (magnetic) suitable for water cooler Capacity 80 ltrs.
Supply and fixing door rubber inner liner (magnetic) suitable for water cooler capacity 150 ltrs. Make : Voltas/ Bluestar/ as per site requirement
REFRIGERATOR
Disconnecting unserviceable Refrigerator of any capacity from existing location and transporting to workshop for repair and re-installation in original position (Necessary replacement of spare parts will be measured and paid separately in respactive items).
Supply and fixing of sealed compressor for repair of 165/180 ltrs capacity Refrigerator as taken out from above all as specified and directed. Make : shriram/ Kirloskar.
All as per Serial item No 77.00 here-in-above but for sealed compressor refrigerator of capacity 286/ 300 ltrs. Make : shriram/ Kirloskar.
S&F Thermostat for refrigerator Capacity 165/180 Ltrs. Make : Renetor/ Shriram/ Godrej/ Danfoss
S&F Thermostat for refrigerator Capacity 286/ 300 Ltrs. Make : Renetor/ Shriram/ Godrej/ Danfoss
S&F chiller tray for refrigerator for 286/ 300 ltrs Capacity.
S&F PVC Ice tray for refrigerators. Make : LG/ Samsung/ Whirlpool
S&F Vegitable tray for refrigerators 165/180 ltr Capacity.
S&F vegitable tray for refrigerators 286/300 litre capacity.
S&F door hinges suitable for referigerator 165/ 180/ 286/ 300 litre Capacity.
S&F Refrigerator freezer unit evaporator door only capacity 286/ 300 litrs.
S&F refrigerator freezer unit evaporator door only capacity 165/ 180 ltrs with spring.
S&F copper capillary tube assembly for 286/ 300 litr Capacity refrigerator
S&F Cooling coil tube assembly, aluminum for 286/ 300 litre capacity refrigerator.
S&F Cooling coil tube assembly, aluminum for 165/180 litre capacity refrigerator.
S&F PVC refrigerator stand suitable for165/ 286/310 litre refrigerator Make : As per sample
S&F above but for Timer assembly suitable for 165/180 ltrrefrigerator (Make:- INDFOSS /Renetrol).
S&F Timer assembly suitable for 286/ 300 litre refrigerator Make : INDFOSS/ Renetrol.
Supply and fixing door rubber inner liner suitable for refrigerator capacity 165 ltrs
Supply and fixing door rubber inner liner suitable for refrigerator Capacity 286/ 300 ltrs.
DEEP FREEZER
Disconnecting unserviceable Deep Freezer of any capacity fron existing location and transporting to workshop for repair and re-installation in original position (Necessary replacement of spare parts will be measured and paid separately in respactive items).
Supply, install, test and commission hermetically sealed reconditioning compressor suitable for 330/ 320 ltr capacity Deep freezer of different makes including vacuum sing, initial charging of oil and refrigerant gas of required quantities to ensure efficient functioning and proper cooling & testing complete all as directed. Note : Refrigerant and comp oil for charging to be supplied by the contractor. The Factory Re-conditioned Compressor shall be accompanied by certificate from the manufacturer to the effect that the compressor has been repaired at their Authority Service center. Further, a warranty of not less than 12 months shall be provided on the compressor. Make : Tecumseh/ Kirloskar.
All as per Serial item No. 98.00 here-in-before but for Deep freezer of capacity 500 Ltrs. Make : Kirloskar/ Tecumseh.
Supply and fixing of new overload protector suitable for 300/ 500 ltrs capacity Deep freezer to match with the existing design. Make : Renetor/ Shriram/ Godrej/ Danfoss.
S& F for replacement of unserviceable thermostate with new suitable for 310/ 300/ 286/ 185/ 165 litre capacity Deep freezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. Make : Renetor/ Shriram/ Godrej/ Danfoss.
S& F for replacement of unserviceable open type relay with new suitable for 320/ 500 litre capacity Deep freezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. Make : Renetor/ Shriram/ Godrej/ Danfoss.
S& F for replacement of unserviceable pigmy lamp with new suitable for any capacity Deepfreezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge.Make :Plhilips/Omex.
S& F for replacement of unserviceable relay with new suitable for any capacity Deep freezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge. Make : Sriram/ Godrej.
S& F for replacement of unserviceable strainer with new suitable for any capacity Deep freezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge.
S& F for replacement of unserviceable capillary copper tube with new suitable for any capacity Deep freezer as per the existing size & make complete all as specified and as directed by Engineer-in-Charge.
M&L for rubber door gasket suitable for Deep freezer of any capacity/ make and provision for making air tight of the system complete all as specified and as directed by Engineer-in-Charge.
M &L for Refrigerant charging of 320/ 400 ltr capacity Deep freezer with required quantity refrigerant gas after vaccuumising the system thoroughly, sealing and leak testing complete all as specified and as directed by Engineer-in-Charge.
Checking, Diagonisis and Rectifying Minor faults in Deep Freezers of any capacities at installed locations as per site requirements complete all as specified and as directed by Engineer-in-Charge.
Supply and charging of refrigerant Gas R-134a to summer cooling appliances all as specified and directed by Engr-in-charge.
M&L for sub main wiring with 2 x 2.5 Sq mm PVC insulated single core unsheathed stranded copper conductor drawn in and including PVC conduit including continuous running earth wire by 2.5 Sq mm PVC unsheathed single core stranded copper conductor connected to common earth dolly including MS terminal with halan sheet boxes complete all as specified and directed. Make for cable : Havells/ Finolex/ Nicco/ KEI/ Polycab. Make for PVC Casing/ Caping : Presto plast/ finolex/ kalinga/ payal/ Prince/ plaza/ AKG/ Harsh. Note : Two runs of 2.5 Sqmm cable and one run of 4.0 Sqmm earth wire and one run of PVC conduit shall be measured as one unit length.
Material and labour for sheet metal clad socket for single pole and neutral enclosure with two pin and earth plug and socket complete with one C-series single pole MCBof suitable size complete all as specified and directed. Make : L&T/ Havells/ Indoasian (Super Plus) / ABB/ L&T/ HPL/ Legrand.
Supply only circuit board suitable for 4/5 KVA stabilizer.
Supply only relay suitable for 4/5KVA stabilizer.
Supply only carbon bushes suitable for 4/5KVA stabilizer.
Supply only control switch suitable for 4/5KVA stabilizer.
Dismantling of Air cooled voltage stablizer 4/5 KVA single phases, 230 volt suitable for AC Supply for repair including assembling, testing after repair work complete all as specified & as directed by Engineer -in-Charge. Note : Spare parts like as Transformer, circuit board, relay, control switch & voltmeter etc. shall be measured & paid as supply only under Serial item No 113.00 to 116.00. Fixing charges shall also deemed to be included in the unit rate of this items. Nothing extra admissible on this acccount.
Supply only indicating lamp suitable for 4/5KVA
S&F in repairs High voltage cutter suitable for 1.5/2.0 TR split AC incuding digital display of voltage Ampere etc. Make : Venus/ V-guard
S&F in repairs transformer for Servo type voltage stablizer 4/5 KVA suitable for single phase 230 volt, AC supply complete all as specified and as directed by Engineer-in-Charge. Make : Venus/ V-guard.
Disconnecting and removing unserviceable 1x20 TR sealed compressor (Chiller Plant at AKM Site) and replaced with new 1x20 TR sealed compressor of existing make & model with including soldering/ brazing of liquid /gas pipeline, cleaning the system arresting the leakage, vacuumization, initial charging of oil & refrigerant gas what ever quantity required including installation, testing & commissioning etc. complete all as specified and directed by Engineer-in-Charge. Note : Refrigerant and comp oil for charging to be supplied by the contractor. The Factory Re-conditioned Compressor shall be accompanied by certificate from the manufacturer to the effect that the compressor has been repaired at their Authority Service center. Further, a warranty of not less than 12 months shall be provided on the compressor. Make : Tecumseh/ Kirloskar or equivalent.
Disconnecting and removing unserviceable with repair of pump motor up to 7.5/10 HP including rewinding of motor with copper enamelled wire of same gauge and refixing at the existing place including installation, testing & commissioning etc. complete all as specified and directed by Engineer-in-Charge. Note : The Factory Re-conditioned of pump motor shall be accompanied by certificate from the manufacturer to the effect that the pump motor has been repaired at their Authority Service center. Further, a warranty of not less than 12 months shall be provided on the rewinding of motor. Note : Rate quoted shall included transportation, charge of pump set to civil method of authorised service center and bringing back & fixing to original location.
Supply only High- pressure water pump powered by a robust 1800 Watt electric motor, the PW-400 delivers excellent cleaning performance with maximum pressure of 120-150 bar, ensuring tough dirt and stains are removed effectively includes 'straight nozzle', 'bend nozzle', 1Litre foam bottle, 26-feet hose, 10 ft suction pipe & a 4-meter electric wire for verastile use in various cleaning applications. Built with High quality materials for long-lasting performance.The heavy-duty plunger pump and pure copper motor ensure reliablity even in demanding conditions of Make- BALWAN (Model -PW-400)
Supply only digital Craft Analog Tire Pressure Gauge for measuring pressure of R 410A, R32, R404AR 134A Refrigerant Gas Refill, 2-Valve testing Manifold guage set AC Tools (800 PSI) Make : Digital Craft Model No- (R410A, R32, R404A, R134) or equivalent Make.
M/s Shree Shyam Traders (BID ID -3251272)
M/s Capital Traders (BID ID -3249419)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .