| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.7 L+₹1.2 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Other Than lowest bidder | |
| 3 | L3₹14.9 L+₹5.4 L (56.9%)Rejected-Finance | L3 | Rejected-Finance Other Than lowest bidder | |
| 4 | L4₹15.6 L+₹6.1 L (64.1%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Other Than lowest bidder | |
| 5 | L5₹16.9 L+₹7.4 L (77.7%)Rejected-Finance | L5 | Rejected-Finance Other Than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Oct 2022, 2:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
REPAIR / MAINTENANCE OF DG SETS AND SOLAR PLANT INSTALLATION AT AF STN BAMRAULI
2022_MES_550826_1
8742/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹40,000
24 Nov 2022
8 Sept 2022
4 Oct 2022
8 Sept 2022
3 Oct 2022
26 Sept 2022
Amount
Disconnecting DG set 200/225 KVA from main line opening the DG set engine by the help of tool and plants and taking out all the components i.e. cylinder head, piston assembly, cylinder, connecting rod assembly bearing and other part, cleaning, checking and carryout repair/replacement of unserviceable /worn out parts, cleaning the chamber filling of lub.engine oil, reassembling all the parts, commissioning and testing on full load all as directed by Engr-in-charge. Make:- Cummins Note – New parts & engine oil replaced will be measured & paid separately as mentioned in respecive srl below of this schedule.
Supply and fix the following spare parts suitable for DG set 200 KVA/225 KVA as per srl 01 above :-
Piston assembly
Piston Ring
Piston Pin
Liner cylinder
CR bearing
Set of "O" ring
Inlet valve
Exhaust valve
Valve seat
Valve guide
Copper sleeve injector
Engine gasket set Complete (Upper and lower)
Rubber Hose Pipe set
Water pump
Timing oil seal
Filter set complete with Air filter
Supply and fixing safety control trip for low lubricating oil pressure alongwith connected control wiring, relay etc including taking down unserviceable safety device complete all as specified & directed by Engr-in-Charge for following :-
DG set 15 KVA to 82.50 KVA
DG set 125 KVA to 320 KVA
Supply and fixing safety control trip for high water temperature along with connected control wiring, relay etc including taking down unserviceable items compete all as specified & directed by Engr-in-Charge for following :-
DG set 15 KVA to 82.50 KVA
DG set 125 KVA to 320 KVA
Taking out unserviceable FIP from DG set and transportation to civil workshop for overhauling, calibration and replacement of worn out parts such as plunger, element, delivery valve, gear, oil seal, roller pin, spring rotor assembly etc including complete testing all as specified & directed by Engr-in-charge for following capacity of DG Set :-
DG set 15 KVA to 30 KVA
DG set 50 KVA to 125 KVA
Taking out choked injection nozzle from the engine assembly and transportation to civil workshop for overhauling and reassembling after calibration of nozzle on admissible pressure, and replacement unserviceable parts such as injector element, kit injector, retainer injector cup and connected itmes, refixing in position, fixing Tappit cover packing set and adjustment by dial gauge complete with satisfaction as directed for following DG set :-
DG set 15 KVA to 30 KVA
DG set 50 KVA to 125 KVA
S&F Engine Monitoring System (ESM) alongwith meter for pressure, fuel, RPM etc, with all electrical instruments and accessories including taking down unserviceable SU with testing complete all as specified and directed
Taking down unserviceable governer hydraulic system from DG set and transportation to civil workshop for repair/overhauling complete with the help of lathe machine and cleaning complete all as specified & directed by Engr-in-charge for capacity of DG set 200 KVA to 225 KVA
Taking out Turbo charger assembly from the DG set and transportation to civil workshop for repair and overhauling with replacement of unsv. Turbo Kit and Turbo Core complete refixing to DG and testing air pressure all as specified and directed by Engr-in-charge for following capacity :-
DG set 125 KVA
DG set 200 KVA to 225 KVA
Supply and fixing in replacement of solenoid switch for 7.5 to 30 KVA DG set complete with connection and testing on load all as specified and directed.
Supply and fixing in replacement of solenoid switch for 40 to125 KVA DG set complete with connection and testing on load all as specified and directed.
Supply and fixing in replacement of solenoid switch for 200 to 320 KVA DG set complete with connection and testing on load all as specified and directed.
Supply only new lubricating oil 15W/40 multi grade, confirming to IS complete all as specified & directed. Make:- Servo/Castrol/MAK/Valvoline
Supply & filling new radiator coolant complete all as specified & directed. Make TVS-Girling /K-Cool/ Castrol
M&L for servicing/maint of DG set of following capacity complete with replacement of old lub oil, fuel filter, lub oil filter, air filter cleaning of oil tank,draining out complete engine oil from the sump and filling fresh oil as required and also checking starting system ,dynamo, metering devices etc including testing the DG Set for satisfactory performance and complete all as specified and directed by Engr-in-Charge. ( Note :- Replacement of unserviceable parts and Lubricating. oil shall be measured and paid separately under respective items of this schedule)
DG set 7.5 KVA to 15 KVA
DG set 20 KVA to 30 KVA
DG set 40 KVA to 62.50 KVA
DG set 82.50 KVA to 125 KVA
DG set 200 KVA to 320 KVA
Supply only following spare parts :-
Lub oil filter assy complete suitable for DG set 7.50 to 15 KVA
Lub oil filter assy complete suitable for DG set 20 to 30 KVA
Lub oil filter assy complete suitable for DG set 40 to 62.50 KVA
Lub oil filter assy complete suitable for DG set 82.50 to 125 KVA
Lub oil filter assy complete suitable for DG set 200 to 320 KVA
Air filter element complete suitable for DG set 7.50 to 15 KVA
Air filter element complete suitable for DG set 20 to 30 KVA
Air filter element complete suitable for DG set 40 to 62.50 KVA
Air filter element complete suitable for DG set 82.50 to 125 KVA
Air filter element complete suitable for DG set 200 to 320 KVA
Fuel filter complete suitable for DG set 7.50 to 15 KVA
Fuel filter element complete suitable for DG set 20 to 30 KVA
Fuel filter element complete suitable for DG set 40 to 62.50 KVA
Fuel filter element complete suitable for DG set 82.50 to 125 KVA
Fuel filter element complete suitable for DG set 200 to 320 KVA
Super by pass/Fuel filter secondary/water seperator suitable for DG set 20 to 30 KVA
Super by pass/Fuel filter secondary/water seperator suitable for DG set 40 to 62.50 KVA
Super by pass/Fuel filter secondary/water seperator suitable for DG set 82.50 to 125 KVA
Super by pass/Fuel filter secondary/water seperator suitable for DG set 200 to 320 KVA
Taking down brunt unserviceable Automatic Voltage Regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 15 to 125 KVA DG Set including connecting all electrical connections. Testing voltage after starting engine and setting properly if a difference all as specified and directed.
Supply and fixing fuel pipe of DG set any capacity including fixing with clamps and tightening arrangement complete with testing and checking all as specified and directed.
Supply and fixing Rubber hose pipe set complete with clamp and nut bolts with fixing with replacement of worn out hose pipe of following capacity DG set all as speclified and directed.
DG set 7.5 to 30 KVA
DG set 40 KVA to 125 KVA
DG set 200 KVA to 225 KVA
Taking out existing unserviceable PT pump assembly from the engine, Supply and fixing new PT Pump complete with proper connection all as specified and directed for follwing capacity of DG set :-
DG set 15 KVA to 30 KVA
DG set 50 KVA to 125 KVA
DG set 200 KVA
Taking down radiator assy of following DG set from engine base frame by descrewing complete nuts & bolts, transporting to civil work shop cleaning complete, tubes , fins etc including soldering leakage portion mac solution should be used in cleaning Roding tube with prope size of steel stick. Transporting back to DG set re installing by using gasket set, Hose pipe set with steel adjustable clamp complete Replacing rubber Hose set by taking out old Hoses with Gubli clips complete, reassembling, commissioning and testing on full load pressure all as specified and directed. Note :- The unit rate includes the cost of all material required for functioning of radiator assembly & no extra payment will be made.
DG set 82.50 to 125 KVA
DG set 200 KVA to 225 KVA
Taking down old self starter 12V from engine, repairing/overhauling, reassembling testing including ensuring smooth functioning by replacement of following spare parts complete all as directed:-
Armature assy
Vendex pinion
Carbon brush holder with carbon set
Nuts Bolts & Washer
Electrical coil
Taking down old self starter 24V from engine, repairing/overhauling, reassembling testing including ensuring smooth functioning by replacement of following spare parts complete all as directed:-
Armature assy
Vendex pinion
Carbon brush holder with carbon set
Nuts Bolts & Washer
Electrical coil
Supply and fixing in repair/replacement of unserviceable or broken Door hinges suitable for any capacity and any size canopy of DG set at different locations complete all as specified and directed.
Taking down old/unserviceable control wiring by disconnecting unsv. AMF panel any capacity, M&L for complete rewiring of AMF panel with suitable size of copper cable by disconnecting all its electrical connection and checking all loose connecting of accessories and tightening properly, cleaning of carbonised panel by the help of carbon tatra chloride and welding of panel door and other connected accessories,complete commissioning ,testing to the entire satisfaction of the Engr-in-Charge.
S&F in repair/replacement the following items in AMF/LT Panel :-
Auxillary Contactor with add on block 2NO+2NC 240/415V AC Make : L&T/ C&S / Siemens
Power contactor 80A , 4P, 240/415 V AC . Make:- LSIS " Metasol" / L&T/TC"C&S"
MCB TPN 415V 32A 'C" Series. Make:- L&T/ Legrand/Schneider
MCB TPN 415V 63A 'C" Series Make:- L&T/ Legrand/Schneider
MCB SP 6 to32A 'C" Series. Make:- L&T/ Legrand/Schneider
MCB SPN 32A 'C"series. Make:- L&T/ Legrand/Schneider
VMR 3P 415V. Make: Proton/ Minilec
ETM DI timer 12V/24V DC.
ETM DI timer 240V/415V AC.
On delay timer 5-100 sec. 240V AC. Make:- L&T/Siemens
Copper Lugs 35 sqmm
Copper Lugs 95 sqmm
CT ratio 200/5. Make:- L&T/AE.
Digital panel meter, multifunctional type 3 phase, 4 wire, 5A balance 90-300 V AC, Model A Class 1. Make :- L&T, AE
Ammeter 0-500A with CTs of size 96x96mm panel mounting digital type accuracy class -1. Make :L&T/ Rishab/AE
Voltmeter 0-500V with CTs of size 96x96mm panel mounting digital type accuracy class -1. Make :L&T/ Rishab/AE
Phase Indication lamp LED type of any colour as per site requirement directed by Engineer-in-Charge.
Fuse links kitkat type 230V 6A to 32A.
Start and Stop push button 3NO.
8 /11 Pin relay 12V/24V DC with base. Make : L&T / Pla
S&F 8/11 Pin relay 240V/415V AC with base complete all as specified and directed. Make:L&T/Pla
S&F in replacement of Thermal Overload relay having a range of 24-40 A suitable for 62.50 to 125 KVA AMF Panel all as specified and directed. Make:L&T/Siemens/C&S
M&L for replacing panel door locks brass HEAVY DUTY Allen key operated suitable to match the existing one including taking down the existing defective one all as directed.
S&F Under voltage/Over voltage relay 240/415V AC 3 phase, 4 wire, time & power ON-delay 1-10 Sec. All as specified and directed.
S&F On delay Multifunction ET timer 240V all as specifed and directed. Make: L&T/Siemens
Supply and fixing in replacement on line battery charger 12Volt complete with connection, testing all as specified and directed. Make:Teknika/NHP/Stronger
Supply and fixing in replacement on line battery charger 24Volt complete with connection, testing all as specified and directed. Make:Teknika/NHP/Stronger
Supply and fixing Power Contactor 400 Amp 4 pole ,415 volt having an auxillary contacts of 2NO+2NC complete with connection, commissioning and testing all as specified and directed. Make: L&T / TC"C&S"
Supply and fixing in replacement 4 Pole power contactor with auxillary contact confirming to IS/IEC 60947, panel mounted, 415 Volt, AC, 50 Hz of capacity 200 Amps with auxillalry contact 2 NO+2 NC complete. Make: L&T / TC-C&S
Supply and fixing in replacement 4 Pole power contactor with auxillary contact confirming to IS/IEC 60947, panel mounted, 415 Volt, AC, 50 Hz of capacity 250 Amps with auxillalry contact 2 NO+2 NC complete. Make: L&T / TC-C&S
Taking down alternator battery charger system 12 V from existing DG set and rapair of alternator by replacing of following spare parts with greasing, servicing, polishing complete and refixing in DG set complete and testing all as specified and directed :-
Rectifier assembly
Stator coil
Cut out
Carbon set
Taking down alternator battery charger system 24 V from existing DG set and rapair of alternator by replacing of following spare parts with greasing, servicing, polishing complete and refixing in DG set complete and testing all as specified and directed :-
Rectifier assembly
Stator coil
Cut out
Carbon set
S&F in replacement Fan belt for the following DG Sets all as specified and directed by Engr-in-charge:-
15 KVA to 30KVA DG Set
50 KVA to 125 KVA DG Set
200 KVA to 320KVA DG Set
S&F Power Command Control Assy (PCC) alongwith required assecories including taking down unserviceable PCC from the DG set 200 KVA complete all as specified and directed by Engr-in-charge.
Supply & fixing Relay card 12V for suitable DG set including taking down old unserviceable relay card from existing DG set complete all as specified and directed by the Engr-in-charge.
Supply & fixing Relay card 24V for suitable DG set including taking down old unserviceable relay card from existing DG set complete all as specified and directed by the Engr-in-charge.
Taking out Injector Nozzle by opening the tappet cover of the DG set 200 KVA/ 225 KVA from the engine and transportation to civil workshop for repair/replacement of unserviceable spares such as Barrel & Plunjer, retainer, injector cup, ball check and spring etc. complete and cleaning all the parts with the help of CTC, complete assembling, commissioning and installation the injector assembly with tappet cover packing complete and testing of DG set on full load all as specified and directed by Engr-in-charge. Note:-(New spare part shall be measured and paid seperately under item No 44 here in after)
Supply only following spare parts suitable for DG set 200 KVA / 225 KVA:-
Barrel & Plunjer
Injector Cup
Retainer
Ball check
Taking down old unserviceable engine safety control wiring of DGset any capacity and disconnecting all its electric connection and material and labour for new engine safety control wiring by suitable gauge of copper wire complete with all accessories and testing with full load complete all as specified and directed .
Taking out fuel tank from the DG set any capacity by disconnecting its connection from the DG set and carrying out necessary checking for leakage and welding work for make tank leak proof, cleaning of fuel tank by removing all the sludge material deposited in the tank and also cleaning of chocked fuel pipe including replacing of unserviceable/broken Gate valve, elbows, sockets, etc. complete all as specified and directed and re-installing to the DG set complete all as specified and directed.
Comprehansive maintenace operation and servicing of all solar equipments installed in 820 SU , P-76 & in officer mess LT control system, Isolation Transformer , weather monitoring equipments, serviceabililiy of SCADA system as per OEM recommendations. Contractor once a week clean solar PV modules by washing , sprays , brushes tools and plant, any washing solutions and also clean the invertors and if any fault occur in invertor or any equipment the contractor shall responsible to tie up with company and rectify the fault and also refill the distilled water in inverter as and when required as per laid down norms for solar power plant complete all as directed by the Enginneer in charge.
Supply, fixing and installation of Lead acid Battery maintenance free with Solar system with replacement of old for depositing to MES stores complete of following rating. Battery 12 V, 200 AH Make : Exide/Amaron/Tata Green
M&L for extension of exhaust Pipe of existing 200 KVA DG Set from DG Set Room by using MS flanged pipe of approx 3-4 mtr of dia 125 mm mininmum thickness 2mm bends, packing , nut bolt washer etc and fabrication work complete all as specified and directed. Note:- Neccessary welding work/cutting work deemed to be included in Quoted rates.
Disconnecting of all electrical and mechanical connection of 50 KVA to 125KVA DG set from engine and taking down unserviceable alternator, carryout necessary repairing and overhauling of alternator by replacement of unserviceable rectifier assembly, exciter assembly, carbon brusher and holder, rewinding of alterantor, field, insulation, testing, greasing, varnishing, polishing of the ring, rassembling & refixing in engine testing complete all as specified and directed by Engr-in-Charge for the capacity.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
K R GUPTA AND SONS
gangotri enteriprises
Mohit Enterprises
M/S KESHRI WORKERS
M/S SWASTIK BUILDERS
Bharat Trading Company
chauhan construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .