| 1 | L1₹12.8 LAccepted-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.7 L+₹18,807 (1.39%)Rejected-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹14.3 L+₹79,843 (5.90%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹14.7 L+₹1.2 L (8.58%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹15.0 L+₹1.5 L (10.7%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC Rejected |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
16 Jul 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-28/2020-21 REPAIR/REPLACEMENT OF ALUMINIUM WIRING INCLUDING INTERNAL FITTING AND FIXTURE AND OTHER CONNECTED WORKS IN CERTAIN OTM AND MD ACCN OF 71 SUB AREA 250 TRANSIT CAMP PRO UNIT AND UP/DOWN CONVEY GROUND UNDER GE(NORTH) UDHAMPUR
2020_MES_353967_1
GE/U(N)-28/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE NORTH UDHAMPUR
CLASS D
8 documents required · 8 mandatory
₹500
GE (NORTH) UDHAMPUR
₹50,000
Yes
22 Jul 2020
19 Jun 2020
18 Jul 2020
19 Jun 2020
16 Jul 2020
2 Jul 2020
Amount
Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc. Complete all as specified and directed by Engr -in- charge. Note : (i) Old dismantled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches,sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down Old Serviceable/unserviceable MCB DB and VTPN any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by engineer in charge.
Point wiring for one light point controlled by one way switch 5 Amp with 1.5 Sqmm single core multistanded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia , ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
Point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multistranded copper conductor, medium grade ISI marked drawn into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn in to and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continuous earth wire connected to common earth dolly complete all as specified and directed by Engineer in Charge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board. Complete all as specified and directed by Engr -in-Charge.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 above but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controlled by 2 Nos.of two way switch.
Point wiring with multistranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 Sqmm drawn in and incl PVC casing and capping with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlite sheet complete all as directed by Engineer-in-charge.
All as per item No 11 above but for two way point wiring
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board.with cable1.5 sqmm size.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board.with cable1.5 sqmm size.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continuous earthing with multistandred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
Switch piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge.
Fixing only serviceable switch piano, flush type, one way, single pole, 5 Amps, obtained from item no 02 as above complete all as directed by Engineer- in - Charge.
Switch piano flush type single pole two way 5 Amps, all as specified and directed by Engineer- in - Charge.
Fixing only serviceable switch piano, flush type, two way, single pole, 5 Amps, obtained from item No-02 as above complete all as directed by Engineer- in - Charge.
Socket outlet two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable two in one, 3 Pin, 5 Amp flush type socket outlet obtained from item No-02 as above complete all as directed by Engineer- in - Charge.
Switch piano type single pole 16/20 Amps one way, complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Switch Piano, flush type, One way, single pole, 15 Amps, obtained from Item No -02 as above complete all as directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable two in one, 3 Pin, 5 and 15 Amps, flush type socket outlet obtained from item No-02 as above complete all as directed by Engineer- in - Charge.
Ceiling rose three terminal, PVC / polycarbonate, isolated body complete all as specified and directed by Engineer - in - Charge.
Fixing only serviceable Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body obtained from item No-02 as above complete all as directed by Engineer - in - Charge.
Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge
Fixing only serviceable Calling bell, obtained from item No-02 as above complete all as directed by Engineer- in - Charge.
Switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge.
Fixing only serviceable Push bell switch piano, flush type, white colour, obtained from Item No-02 as above complete all as directed by Engineer- in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge. .
Fixing only serviceable Stepped type, electronic fan regulator, flush type on the existing phenolic laminated sheet etc. as obtained from Item No-02 as above complete all as directed by Engineer- in - Charge.
Fixing only serviceable light fittings any type as obtained against item No 2 all as specified and directed by Engineer-in-Charge
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 36
Earthing in repair complete with galvanized steel earth electrode 60cmX60cmx6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, GI 4.0mm dia lead wire 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1).
Earthing in repair complete with copper plate earth electrode 60cmX60cmx3.15 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, 20x 3 mm copper strip, 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1).
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC concealed conduit medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4sqmm and one run of 4 Sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
All as per item No. 40 herein before but with 6 Sqmm pvc copper conductor cable through PVC conduit ISI marked with 6 Sqmm copper conductor cable as earth continuity conductor.
All as per item No. 40 herein before but with 10 Sqmm PVC copper conductor cable through PVC conduit ISI marked with 10 Sqmm copper conductor cable as earth continuity conductor.
Sub main wiring with two run single core 4 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia PVC surface conduit/PVC casing capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4sqmm and one run of 4 Sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM.
All as per item No. 43 herein before but with 6 Sqmm pvc copper conductor cable through PVC conduit ISI marked with 6 Sqmm copper conductor cable as earth continuity conductor.
All as per item No. 43 herein before but with10 Sqmm PVC copper conductor cable through pvc conduit ISI marked with 10 Sqmm copper conductor cable as earth continuity conductor.
Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge
Socket outlet Two in one, 3/5 Pin piano type 5 Amp and 15 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge..
Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination Box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Switch socket combination Box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body fixed in replacement, complete all as specified and directed by Engineer - in - Charge.
Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge.
Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge.
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair sheet metal enclosure double door single pole and neutral 240 Volts for DB's when MCBs to be used 8 way with 200 amp rated bus bar with IP-43 protection complete all as specified and directed by engineer in charge.
All as per srl item No 60 above but 4 way, complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 60 above but 12 way, complete all as specified and directed by the Engr-in-Charge.
Supply and fix in repair sheet metal enclosure VTPN 4 way 415 volt 250 Amp rated bus bar double door type with suitable for mounting MCCB for incomer and MCBs for outing without MCCB and MCB IP-43 protection fixed in repair complete all as directed by Engr-in-Charge.
All as per srl item No 63 above but 6 way, complete all as specified and directed by the Engr-in-Charge.
All as per srl item No 63 above but 8 way, complete all as specified and directed by the Engr-in-Charge.
MCCB 4 pole, 415 volt, Adjustable type 100 Amp with breaking capacity 16 KA complete complete all as specified and directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 160 Amp with breaking capacity 16 KA complete complete all as specified and directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 200 Amp with breaking capacity 25 KA complete complete all as specified and directed by engineer in charge.
MCCB 4 pole, 415 volt, Adjustable type 250 Amp with breaking capacity 25 KA complete complete all as specified and directed by engineer in charge.
MCB SPN 40 TO 63 AMP 240V, 50HZ, 10KA 'C' Series for lighting and other domestic loads incl necessary copper lugs etc all as specified and as directed by Engineer-in-Charge.
MCB SP 6 to 32AMPs 'C' Series connection and testing complete all as specified and directed by engineer in charge.
MCB SP 40 to 63 'C' Series connection and testing. complete all as specified and directed by engineer in charge.
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Modular fan step regulator 120W 02 module including taking down unserviceable one all as specified and as directed by engineer in charge.
Modular switch 01 way 06A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge.
Modular switch 01 way 16A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge.
Modular bell push flush type 6A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge.
Modular socket, 6A-2/3 pin, 02 module including taking down unserviceable one all as specified and as directed by engineer in charge.
Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceable one all as specified and as directed by engineer in charge.
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep including making necessary cutting all as specified and as directed by engineer in charge,
PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep including making necessary cutting all as specified and as directed by engineer in charge,
3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
Slim linear LED lighting fixture 4/5W watt LED batten, with full base of extruded polycarbonate isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge. Make of LED -Syska Cat No:SSK-SQ0401/Wipro Cat No : D530565/C&S Cat No: LTTBIF5WLED/W/ Havells: Cat No: LHEXBXPNIN1W005
Slim linear LED lighting fixture 20 Watt LED batten, P.F greater than 0.9, input voltage range from 90 Volts to 280Volts with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5sqmm copper conductor multistranded PVC insulated 2 core flexible cable with from ceiling rose to fitting complete all as specified and as directed by Engineer-in-Charge. Make : Syska Cat No: SSK-SQ2001/Havells Cat No: LHEXBXPNIN1W020/ or equivalent to Wipro
LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by engineer in charge. Make Syska Cat No: SSK-BH-9W /Wipro Cat No : DA11265/Crompton :Cat No: LBHE-10-DL /Havells: Cat No: RUGBYNEONFT10WLED860SSYMTOPC
Decorative ultra slim linear polycarbonate Extruded LED lighting fixture 10/12 Watt LED of input voltage AC 220V-240V, 50 Hz with colour temperature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated twin core flexible cable from ceiling rose to fitting complete all as per directed by Engr-in-charge. Make Syska Cat No: SSK-SQ1201 Wipro Cat No : D531065/Havells: Cat No: LUMILINEPLUSBS10WLED865SPCSS/ Philips Cat No : BN 021 LED10S- 6500 PSU GR S1
Ultra modern designed architectural 2x2 LED, 6500K, 40 watt luminaries which provides soft light and glare free symmetrical illumination (VENUS NEO) fixed in replacement. complete all as per the direction of Engr-in-Charge. Make -Make of LED -Wipro as per ordering code D414065 or equivalent model of Havells or CG.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. Complete all as specified and directed by Engr-in-Charge.
LED garnet 18 W NR lamp,4 pin type, 6500K, as per sample fixed in repair complete all as per the direction of Engr-in-Charge.
LED T8 retrofit tube rod lamp 22W, 6500K, as per sample fixed in repair complete all as per the direction of Engr-in-Charge.
MCB TPN 63 Amp, 415 Volts- C curve of 10kA complete all as specified and directed by engineer in charge.
Isolator 4 Pole 100 Amp, 415 Volts complete all as specified and directed by engineer in charge.
Isolator 4 Pole 125 Amp, 415 Volts- complete all as specified and directed by engineer in charge.
Plug and socket DBs, single pole and neutral enclosure with a two pin earth plug and socket with one single 20 Amps, 240 volts MCB complete all as specified and directed by engineer in charge.
Modular white cover plate with frame 3 module, complete all as specified and directed by Engineer- in - Charge.
Modular white cover plate with frame 4 module, complete all as specified and directed by Engineer- in - Charge.
Modular white cover plate with frame 6 module, complete all as specified and directed by Engineer- in - Charge.
Modular white cover plate with frame 8 module, complete all as specified and directed by Engineer- in - Charge.
Rigid non - metallic PVC casing capping of 25/12mm inclusive of all elbow, tees,etc fixed in repair complete all as per the direction of Engr-in-Charge.
PVC conduit medium grade 20 mm dia ISI marked with all accessories such as Tees, elbows, junction boxes etc fixed in repair complete all as per the direction of Engr-in-Charge.
All as per srl item No 101 above but 25mm, complete all as specified and directed by the Engr-in-Charge.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth all as specified and directed by engineer in charge.
Disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paid separately under relevant Items.
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
Cutting of hard standing n.exc 45 Cm defth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as directed .
m/s shanti trading company
HIMALAYA ENTERPRISES
DEV RAJ MAGOTRA
SINGH CONST CO
M/S Builders Indias
MAHAJAN TRADING CO
NAVIN KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .