| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.6 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹29.9 L+₹1.3 L (4.39%)Rejected-Finance | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹30.8 L+₹2.1 L (7.50%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹31.9 L+₹3.3 L (11.4%)Rejected-Finance 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹33.0 L+₹4.4 L (15.3%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹42.3 L
EMD Value
₹84,620
Closing Date
3 Aug 2022, 6:00 pmClosed
HQ CWE Agra
112, Taj Road Agra Cantt
PROVN OF BARBED WIRE FENCING WITH CONCERTINA COIL WITH Y SHAPE ANGLE ALONG WITH SECURITY LIGHT OVER THE EXISTING BOUNDARY WALL UNDER GE (EAST) AGRA
2022_MES_536062_1
84258/E8
Open Tender
Civil Works
Item Rate
180 days
Agra
MES contractors enlisted in Class D category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
GE East Agra
₹84,620
Yes
22 Aug 2022
6 Jul 2022
9 Aug 2022
6 Jul 2022
3 Aug 2022
20 Jul 2022
6 Jul 2022 - 13 Jul 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exc 1.5m depth for foundation etc and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc 1.5m depth for foundation etc and getting out in any type of soil with required slope complete all as specified and directed.
M&L for providing PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work for fair finished flat surfaces complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, for fair finished flat surfaces complete all as specified and directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal on plan), for fair finished flat surfaces complete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars cut to length bent to shape required including cracking bending spirally for hopping for columns etc & binding with MS wire of dia not less than 0.9mm complete all as specified and directed.
All as item No .10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etc.complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping and fixing of hold fast ,angle post etc,including formwork side to side of wall complete all as specified and directed.
S&F for galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, straples or steel pins etc complete all as specified and directed.
S&F barbed razor type concetina coil hot galvanised spring tensile wire fixed on 'Y' shape angle post and barbed wire over compound wall, coil of 6 to 8 RM per coil of 610mm dia, minium weight of coil shall be 7.50 kg/coil etc complete all as specified and directed.
S&F for mild steel angles or tees etc as in posts and struts in fencing including embeding in concrete and screwing etc. including cut to shape as directed, drilling holes, notching forwire etc including all necessary drilling, bolting, welding or riveting and similar work conforming to FE-290 Gde E-165 complete all as specified and directed
Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1 : 4 on any faces of brick masonry surfaces,finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cemant lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for kay, scrubbing down with water complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1 : 4 on any faces of brick masonry surfaces,finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface and applying two coats of cement based paint white or tinted over a coat of primer complete all as specified and directed
M&L for in applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of steel surface of any descripition not otherwise described over 10 cm width or girth complete all as specified and directed.
Returning filling in with approved excavated soil including spreding levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exceedind 1.5 m above starting point complete all as specified and directed.
PCC 1:4:8 type D-2 ( Using 40mm graded crushed stone aggregate ) in foundation filling and mass concrete complete all as specified and directed.
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as item No .26 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, rectangular or polygonal on plan), for fair finished flat surfaces complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforcement cement concrete (design mix ) M-25 (20mm graded stone aggregates) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
S&F Framed work as in ornamental or steel gate revolving on bearing plate incl pintel hinges fixed on pillar with PCC block of size required at site as per sample approved by Engr-in charge. Note:-Weight of gate decided by BOO which will be conveyed by GE before fixing and necessary arrangements for weighing of steel gate by the contractor on his own expense.
M&L for Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching,coping , roof kerbs, mud stop, padding etc and similar work complete all as specified and directed.
M&L Providing, cement concrete 1:2:4 type B1, using 20mm graded stone aggregate in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, complete all as specified and directed.
Material and labour for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms including moulding and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including 15 mm thick screed bed in cement mortar 1:4 completed all as specified and directed.
M&L for sand cushioning to under ground cable provided with layers of sand ( 8 cm deep before laying cable and 15 cm after laying cable) complete all as specified and directed.
M&L for brick covering width equal to length of brick for protection to cable with well burnt sub class 'B' bricks laid dry flat complete all as specified and directed.
M&L for drilling for suitable dia horizontal bore holes for and including insertion/ laying of 50 mm bore HDPE of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine etc) required for boring shall be arranged by contractor at no extra cost to the Govt.
S & F GI tubing 40 mm dia " light grade" for cable protection including suitable size MS clamp for fixing with pole/wall complete all as specified and directed.
S & F High density polyethylene pipes (HDPE) 50 mm bore of pressure rating 6 kgf/cm2 for cable protection laid in trench/fixing with pole/wall complete all as specified and directed.
Supply and lay in trench/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed
M & L for twin core aluminium conductor 4 sqmm PVC insulated , sheathed wire drawn in pole from juction box to street light and including provn of holes in existing pole whereas required complete all as specified and directed.
Supply and errection of steel tubular swaged pole 09 mtr long type 410-SP-31 complete with CI base plate . Finial taper plug, bolts, nuts and screws etc including necessary excavation and earth work, in loose/soft soil of size 600 x 600 x 1900mm, PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in foundation, PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in plinth block/coping disposal of surplus soil up to 50 M, Painting inside with black bitumen paint and out side with two coats of aluminum paint over one coat of red oxide Primer and numbering of poles and black & white striping up to 1.5 Mtr height, 300mm wide complete all as specified and directed. Note :-All type of PCC work, Cross arms, bolts, nuts, washers shall be measured and paid separately in respective item.
Supply and Fix sheet moulding compound(SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of street lights mounted on poles with the provisions of cable entry and exit size of box shall be 280mm X 170mm X 130mm complete all as specified and directed. (Make Sintex/hensel cat part No KF8350/ Siemens/L&T product code NO GSJB-2817 or equvialent model as specified make as approved by GE).
S & F LED security light with aluminium pressure die cast housing , high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, power consumption < 45 W & luminaire lumen > 6600lm and system efficiency > 110lm/W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm, LED Make:- Nichia/ Cree/Osram, CRI>70, ambient temperature range 0-450C, THD<10%, colour temperature 5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria, multistage constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard to including GI pipe medium grade ISI mark of size 32mm dia & length not less than 1.5 mtrs bending to shape for fixing light with nuts, bolts, clamps etc as required to fix with pole/wall complete all as specified and directed.
Supply and fix decorative new generation Flood light fitting energy saving, environmental friendly, long life aesthetically designed with good indirect symmetrical light distribution, die cast aluminium landscape IP 65 protection with high power COB LED as light source of 100 watt LED complete with and including fixing arrangement using GI pipe grouted with PCC to existing piller/post complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode of size 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm dia GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit with PCC type 1:3:6 type C-1 using 20mm graded stone aggregate, with cover in RCC 50mm thick 1:2:4 Type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009
Supplying and fixing in renewal timer switch astronomical 3 pole 08 Kw including enclosure made ofrust proof electric shock proof, termide proof and FRR Grade SMC junction box confirming to IP 54 for street light based on lux level of natural light compete all as specified and directed including fixing arrangement as required at site.
Supply and fix cable jointing kit suitable for 1100 Volts grade LTUG cable 16 sqmm for Indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all as specified and directed.
Material & labour for 100 mm thick PCC (1:3:6) type C-I with using 20mm graded stone aggregate as in path, surfaces finished even and fair with chaquerred impresson etc. complete all as specified & directed .
Supply and fixing busbar chamber, 200 Amps, 415 volt, 4 pole, 50 Hz, 415 volts, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars including fixing arrangement as required at site complete all as specified and directed.
Sree Ram Enterprises
VISHESH BUILDERS
m/s shanti consruction co
M/s Shrangi Rishi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .