Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹6.2 L Quoted ₹6.7 L | L1 | Accepted-AOC Lowest tender accepted |
| 2 | L2₹7.3 L+₹53,862 (7.99%)Rejected-Finance | ₹7.3 L+₹53,862 (7.99%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹7.8 L+₹1.1 L (15.9%)Rejected-Finance | ₹7.8 L+₹1.1 L (15.9%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹8.3 L+₹1.5 L (22.9%)Rejected-Finance 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | ₹8.3 L+₹1.5 L (22.9%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | L5₹8.4 L+₹1.7 L (25.1%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | ₹8.4 L+₹1.7 L (25.1%) | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
11 Apr 2022, 6:00 pmClosed
GE (AF) Adm Area Agra
GE (AF) Adm Area Agra 282008
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL FANS AIR CIRCULATING INCLUDING REPLACEMENT OF ELECTRIC METER IN DOMESTIC AREA UNDER AGE EM OF GE AF ADM AREA AGRA
2022_MES_513720_1
8000-1944/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE AF Adm Area Kheria Agra
₹20,000
Yes
23 Apr 2022
15 Mar 2022
13 Apr 2022
15 Mar 2022
11 Apr 2022
30 Mar 2022
15 Mar 2022 - 29 Mar 2022
Amount
Taking down/collect the unserviceable/burnt ceiling fan/exhaust fan/pedestal fan/wall mounted fan/cabin fan any sweep from any height of building/site for repair/rewinding/overhauling and re-fixing the same after repair/overhauling and testing fans complete at same place or where directed complete all as specified. (i) Fixing of repaired fan in any location domestic area shall be contractors responsibility at his own arrangement of transport and T& P. (ii) Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit attached) Note – Repair/rewinding/overhauling shall be measured & paid separately under respective items of Sch.
M&L for strip opening of ceiling fan 1200 mm sweep for overhauling including cleaning, greasing, oiling and minor repair work, including checking nuts and bolts, clamps etc complete and reassembling the same after testing on full load with blade complete all as specified and directed. (Note: Capacitor, Bearings, Regulators, Rubber reel and other connected items shall be measured and paid separately under respective items as supply and fixing).
Description all as per Item No 2 here-in-before but for exhaust fan size 300 to 450 mm sweep complete all as spd and directed.
Description all as per Item No 2 here-in-before but for wall mounted fan/cabin fan of size up to 450 mm sweep complete all as spd and directed.
M&L for rewinding of ceiling fan motor 1200/1400 mm sweep any make with super enameled copper winding wire ISI marked of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing , threading incl. making connections with three core copper flexible wire of suitable size and reassembling the same and two coats of synthetic enamel paints with spray painting and writing MES number ind. cleaning the fan with cleaning materials or thimmbles after testing at full load with blades to the entire satisfaction of Engineer incharge complete all as specified and directed. Note: Rewinding work of ceiling fan/ exhaust fan/ cabin/wall mounted fan shall be carried out inside the camp area at the location provided by department.
Description all as per Item No 5 here-in-before but exhaust fan of size 300 mm sweep, 230 V, AC complete all as spd and directed.
Description all as per Item No 5 here-in-before but exhaust fan of size up to 450 mm sweep, 230 V, AC complete all as spd and directed.
Description all as per Item No 5 here-in-before but for wall mounted/cabin fan of size up to 450 mm sweep complete all as spd and directed..
M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as directed.
S&F in repair Ball bearing of ceiling fan of size 6201/6202 complete all as spd and directed.
S&F in repair Ball bearing of exhaust fans of size 6203/6204 complete all as spd and directed.
S&F in repair Gun metal bushes for fans of suitable sizes complete all as spd and directed.
S&F in repair capacitor 2.5 MFD, 230V AC complete all as spd and directed.
S&F in repair capacitor 3.15 MFD, 230V, AC complete all as spd and directed.
S&F in repair capacitor 4 MFD, 230V, AC complete all as spd and directed.
S&F in repair shackle rubber bush/rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as spd and directed.
S&F in repair flexible wire 23/0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as spd and directed.
S&F in repair MS nut & bolt with cut washers 8 mm dia of suitable length for hanging of the ceiling fans complete all as spd and directed.
S&F in repair MS clamp for hanging the ceiling fans of suitable size complete all as spd and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as spd and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as spd and directed.
S&F in repair Canopy of suitable size for ceiling fan 1200/1400 mm sweep (white colour) complete all as spd and directed.
S&F in repair ceiling fan regulator electronic switch type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
M&L for preparing the surface of ceiling fan, exhaust fan, pedestal fan including cleaning, removing grease, carbon dust and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number complete all as specified and directed.
M&L for replacement of exisitng unsv meter box with polystrene polycarbonate hinged door, with transparent lid, meter box of size 168 x 253 x 115 mm in accordance with IEC 60670- 24 with IP 65 protection with IEC 60529, corrosion proof suitable for single phase energy meter, internally embedded polyurethane gasket for lid, metric size knock out for cable entry from top and bottom. Meter box should be able to adpt any make of meter complete all as spd and directed. Note:- (i) Taking down existing meter and refixing in new meter box shall be deemed in quoted rate. (ii) Rates include making connections from meter to DB with minimum 4 sqmm single core FRLS PVC insulated multi-stranded copper conductor cable incl. providing pin/ bottle type copper thimbles shall be part of Job. (iii) All wires shall be drawn in PVC flexible conduit of suitbale dia.
S&F in repair new aluminium blades (Set of three) of suitable size for ceiling fan of size 1200 mm sweep as per sample complete all as directed.
Description all as per item No 27 here-in-before but for size 1400 mm sweep.
S&F in repair new metal blades of suitable size for Exhaust fans of size up to 300 mm sweep complete all as directed.
Description all as per item No 29 here-in-before but for Exhaust fans of size up to 450 mm sweep complete all as directed.
S&F in repair fibre blades of suitable size for wall mounted fan of up to 450 mm sweep, complete all as specified and directed.
S&F in repair 15 mm bore GI Pipe, ‘medium grade’ for making down rod of required size for hanging ceiling fan including MS clamps of suitable size and shape complete all as specified and directed.
S&F in repair sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
S&F in repair MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair MCB SPN 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification.
S&F in repair GI tubing 40 mm bore light grade with required fittings at site for provision of hanging of ceiling fans including making hole and making good the disturbed surface to match with existing specifications complete all as spd and directed.
S&F in repair geyser element 1.5 KW Triangle/Round (as per approved sample) ISI marked complete all as specified and directed.
S&F in repair geyser element 2 KW Triangle/Round (as per approved sample) ISI marked complete all as specified and directed.
S&F in repair Geyser thermostat adjustable type between 200C to 600C of ISI marked complete all as specified and directed.
S&F in replacement of PVC insulated copper conductor 3 core cable of size 2.5 sqmm and its connection complete all as specified and directed.
S&F in repair stainless steel inner tank of storage type electric water heater of 25 ltr capacity complete with rubber gasket including necessary nuts, bolts and washers complete all as specified and directed.
S&F in repair mild steel louvers/shutters suitable for 300 mm sweep exhaust fan complete all as spd and directed.
S&F in repair mild steel louvers/shutters suitable for 450 mm sweep exhaust fan complete all as specified and directed.
S&F in repair static energy meter electronic tamper proof energy meter with backlite (LCD with multi features digital type) with two push buttons for manual depation to read the data, single phase two wire direct operated 240V, 50 Hz AC supply, class of accuracy 1.0 operating voltage 140 V to 300 V, AC range basic current 10 A maximum 60 A (10-60 A) conforming to IS 13779/CBIP 88 ISI marked with Engineering plastic transparent pilfer proof meter box to house the single phase and class of protection shall not be less than IP 51, Dust & vermin proof, shock proof of suitable size to house meter freely complete all as specified and directed. Note:- Old Electric meter shall be deposited at E/M store yard.
Dismantling of existing meter panel board removing existing energy meter keeping safe custody and Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover
(g) LED Indicating lamp - 03 Nos. (j) Internal wiring with 1100Volt grade 6.0 Sqmm FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make of meter panel board:- Hansel / Schneider/ L&T
jmd engineers
PATIRAM CONSTRUCTION
M/S SINGH ELECTRIC CO
MUKTA AND COMPANY
TRIVENI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .