| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹46.9 L+₹1.3 L (2.96%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹50.9 L+₹5.3 L (11.6%)Rejected-Finance BIDHAN PALLY OODLABARI P O MANABARI P S MALBAZAR DIST JALPAIGURI | JALPAIGURI | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹54.8 L+₹9.2 L (20.3%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹55.2 L+₹9.7 L (21.2%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE SEVOKE ROAD POST SALUGARA DIST JALPAIGURI
REPAIR AND MAINT OF WATER SUPPLY INSTALLATION PUMP IRP AND CONNECTED WORKS AT SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2020_MES_397998_4
GE/SEV/47 OF 2020-21
Open Tender
Civil Works
Item Rate
270 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
SBI SILIGURI
₹94,000
Yes
9 Feb 2021
16 Jan 2021
27 Jan 2021
16 Jan 2021
25 Jan 2021
19 Jan 2021
17 Jan 2021 - 18 Jan 2021
60 days
Amount
Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, all as specified and as directed.
Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
S & F in replacement of old U/S following MCCB complete all as specified and as directed.
MCCB 40 to 63A, 16KA, 4Pole with thermal magnetic relay
MCCB 100A, 25KA, 4Pole with thermal magnetic relay
MCCB 125A, 25KA, 4Pole with thermal magnetic relay
S&F street light fittings 72 w, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium street security light with high power LED as light source lamp type 72W with SPD, IP 66 protection with toughened glass cover including taking down existing complete all as specified and as directed.
Material and Labour for Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6mm, thick buried directly in ground ( earth pit not less than 2.25 Metre deep below the Ground Level ) with Top Edge of Earth Plate not less than 1.50 Metre deep below normal ground level , connected to Galvanised steel iron earth lead strip 32x6mm by means of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron, 20 mm dia GI Pipe (Med grade) for watering, 40 mm dia GI Pipe light grade for protection of earth lead,including necessary earth work in any type of soil , PCC (1:3:6) Type C1 Concrete pit RCC (1:1.5:3) Type A1 Precast cover (54x54x5Cm) duly reinforced with including 8mm Dia TMT Bar @ 150 mm c/c both ways lifting handle made of 8mm dia TMT Bar embeded in precast cover slab complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and as directed.
M & L for earth continuity conductor fixed to walls burried in ground or drawn through pipe GI strip of size 32x 6 mm complete all as specified and as directed.
M & L for preparation of new plastered surface of wall & applying two coats of weather resistance acylic emusion paint over a coat of primer all as specified and as directed.
M & L for brick work with subclass 'B' bricks stright or curved on plan to any any radius in half brick thick wall built in (1:4) cement mortar complete all as specified and as directed.
M & L for PCC (1:3:6) type C2 using (40mm graded stone aggregate) as in foundation for filling in mass concrete for foundation of IRP plant/Pressure filter or any other works all as directed by Enginner- in -Charge
M & L for rendering 10mm thick on brick work after necessary cleaning with CM (1:4) for pump house building/DG set room all as directed by Engineer in charge.
M & L for 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as pavement/hard-stading inside the E/M installation complete all as specified and directed
M & L for preparation of old plastered surfaces of ceiling and applying one coat of white washing all as specified and directed
M & L for one coat of white washing on wall of pump house building including preparation of old surfaces all as specified and directed.
M & L of painting of wooden door's windows with one coat of synthetic enamel paint over the surface of any description all as directed.
Cutting unaxious green growth and grass by manual labour or by machine at the Installation premisses/ along the boundary fencing and removing rubbish from the site of work where directed not exceeding 100 mtr from the starting point.,complete as directed .
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
M&L for point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum size 75 x75 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete all as specified and as directed. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified.
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts all as specified.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified.
S & F ceiling fan regulator step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system complete all as specified.
S & F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 5 to 30 Amps complete all as specified.
S & F MCB SP 5 to 30 Amps 240 volts for fixing on MCB DB's all as specified.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including casing and caping ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board complete all as specified and directed.
Supply & Laying LT UG XLPE sheathed PVC insulated screened PVC bedded galvanised steel strip of wire armoured electric power cable heavy duty with stranded Aluminium Conductor, 1100 Volt grade, , laid in Trenches/ surface of Wall / in GI Pipe along with the pole for Connections to OH Lines including brass cable glands Mild steel flat iron clamps etc and Testing, complete all as specified and as directed Cross sectional Area of cable
6 Sqmm 2 Core
50 Sqmm 3 1/2 core
95 Sqmm 3 1/2 core
120 Sqmm 3 1/2 core
185 Sqmm 3 1/2 core
M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note:- Punned thickness shall be measured for payment.
S & F Sub-Class ‘B’ Brick, well burnt, laid breadthwise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Transporting defective Openwell submersible Pump of Capacity 5 to 20HP capacity to work shop, dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing and drying, cable jointing, reassembling installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete as directed by Engr-in-Charge Note:- Spare parts shall be measured and paid separately as supply only.
Supply only of following parts of submersible pump of 5 to 20 HP capacity : -
CI stage casing
Bearing bush rubber
Stainless Steel sleeve at staging
Brass impellers
Neck ring brass
Key for impellers
MS stud with nuts of size of 3/8" X 2" for stage casing
Bush gun metal at intermediate section
Steel sleeve at intermediate section
CI intermediate section
Unserviceable stainless steel coupling & key common for submersible pump and motor shaft
Dismantling of GI Pipe Connections from the Pressure Filter Plant of capacity 6000 to 10000 Gallons, opening the Manhole and removal/taking out old Filter Media completely from Oxidation Chamber, Pre-filter, Iron Removal Filter and depositing the same to a distance not exc. 100 Metre and re-fixing the pipes in the original/existing Position after replacement of unserviceable PVC Nozzale (Dome type) including replacement of Gasket of Manhole Cover and necessary Bolts, Nuts, Washers, etc. as required, complete all as specified and as directed.
Supply and incorporation of MNO2 of size 1/8'' x 1/10'' as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1 1/4'' x 1 1/2''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1/2'' x 1''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply and incorporation of GRAVEL of size 1/4'' x 1/2''(collection sourceBARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & incorporation of SAND of size 1/6" x 1/8'' mesh (collection source BARAKAR river bank) as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & incorporation of Anthracite grit of size 1/8" x 1/4'' as filter media of iron removal plant complete all as filter media of iron removal plant ,complete all as specified & directed.
Supply & fixing PVC strainers of sizes as dismantled of Make: PHI/RMCO, complete all as specified & directed.
M & L Painting to External Surfaces of Iron Removal Chamber, Pre-filter Chamber, Oxidation Chamber including Pipes complete of Fiteration Plant capacity 8000 GPH with Two Coats of Sythetic Enamel Paint of approved colour over a coat of Red Oxide Primer including neccessary preparation of surfaces, complete all as specified and as directed.
M&L Painting to Internal Surfaces of Iron Removal Chamber, Pre- filter Chamber and Oxidation Chamber including Pipes complete of Filteration Plant capacity 8000 GPH with Two Coats of Black Bituminous Paint (Lead Free) suitable for Drinking Water grade including necessary surface preparation by means of scraping, brushing, cleaning, complete all as specified and as directed.
M & L for taking out submersible pump set of any capacity from bore well complete with column pipes of any size, submersible cable and steel wire rope and lowering the same in bore well after carry out necessary repairs/lowering of spare Pump including T & P arrangement complete all as specified and as directed.
M&L for transportation of defective pump set to workshop dismantling the same incl Disconnecting electrical connections decoupling 440 volt AC submersible motor pump set of following capacities, dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing and drying, cable jointing and repair replacement of worn out parts of pump reassembling the same with motor installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete :- Note : Spare parts replaced shall be measured & paid seperately under respective item of schedule. Cost of rewiring and winding materials is included in item rate.
M&L for transportation of defective pump set to workshop dismantling the same incl Disconnecting electrical connections decoupling 440 volt AC Centrifugal electrical motor pump set of following capacities, dismantling the motor,taking out burnt winding wire from the stator, cleaning of the casing and the stator with wire brush, rewinding of motor with superior quality copper winding wire of existing size including varnishing and drying, cable jointing and repair replacement of worn out parts of pump reassembling the same with motor installing the motor and pump , reconnecting all pipe and electric connections and testing on full load complete :- Note : Spare parts replaced shall be measured & paid seperately under respective item of schedule. Cost of rewiring and winding materials is included in item rate.
S & F in repair Agitator motor including servicing/ overhauling the pump ,reassembling & brought back to site including taking down burnt unsv motor complete all as directed by Engr-in-charge.
M&L for replacement of the following spare parts of decrine dozer :-
Pump head (Ferrules 1/4" & Duckbill included) (Part No :UCPH7FD)
Roller assembly (Part No :MC3ASYD)
Pump tube (Part No :MCCP 207)
Injection check valve 3/8" diafram packet of 6 piece
Weighted suction line strainer 3/8" (Part No :ST 138)
3/8" White suction/Discharge tubing
Pump Shaft
M & L for chemical for drinking water treatment , calcium based granular high strength disinfectant chlorinating chemical having 65 % to 70 % chlorine content in granular form in 45kg drum. The Chemical should be of new batch number not more than 6 month old manufactured. Brand should be from any manufacturer aproved by E-in-c's branch.
M & L for Non Ferric Alum Crystal type, conforming BIS 260-2001 (2nd Revision), complete all as specified.
S&F 3 Pole Power contactor suitable for 20/15 HP Motor starter or as per existing including taking down existing unserviceable one complete all as specified and as directed.
S&F Single Phase Preventor used for automatic Star Delta Stater with on delay timmer (2-3min) and auto manual switch, complete all as specified and as directed.
M & L for Scraping old paint of Electric Panel and Painting with two coats of synthetic enameal paint over a coat of red oxide primer and the shade paint including disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed.
S&F flat submersible cable 3 core multi stranded copper conductor of size 6 sqmm. complete all as specified and as directed.
Supply and fixing GI submersible column pipe 100 mm bore "Heavy duty" of length 3 meter each, long threaded at both male & female ends and with separate integral female long threaded socket, complete all as specified and as directed.
Supply & fixing in repair Pressure guage of capacity 210 kg/cm2. complete all as specified and as directed.
S&F of 3 phase Digital panel volt Meter Flush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P), including taking out unserviceable complete all as specified and as directed.
S&F 3 phase 5A, Digital panel ammeter Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable including taking down existing unserviceable one complete all as specified and as directed.
S&F 3 phase indicator lamp including taking down existing set complete all as specified and as directed by Engr-in-Charge
M&L for construction of valve chamber of size 1200mm x 1200mmx1200mm (internal dimensions) with MS sheet cover 3mm thick with angle iron frame of size 50 x 50 x 6mm and locking arrangements including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate including necessary formwork,painting one coat of red oxide and two coats of bituminious black paint on all steel surfaces including demolition of existing valve chamber,complete all as specified and as directed.
SHRI JAYANTA GHOSH
RAJIV DEY SARKER
SRI SURAJIT SENGUPTA
M S ALOK SAHA
D.D. BROTHERS
JHA CONSTRUCTION AND CO
SHRI JIBANDHAN PAUL
M/S JANARDAN SHARMA AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .