Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-Finance AT PLOT NO 1662 FAKIRPUR PANDASAHI CUTTACK SADAR ODISHA 754021 | CUTTACK | ODISHA | 754021 | ₹16.0 L | L1 | Accepted-Finance q |
| 2 | L1₹16.0 LAccepted-Finance AT BRAHMANABASTA KAKHADI CUTTACK 75437 | 75437 | ₹16.0 L | L1 | Accepted-Finance q |
| 3 | L1₹16.0 LAccepted-Finance | ₹16.0 L | L1 | Accepted-Finance q |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
15 Apr 2026, 5:00 pmClosed
SE CUTTACK R AND B DIVISION II OMP SQUARE
SE CUTTACK R AND B DIVISION II OMP SQUARE
Supply, Installation, Testing and Commissioning of 125 KVA 3 Phase AMF DG set at Sports Authority of India, NCOE, Jagatpur, Cuttack
2026_EICCL_127872_11
SE CTC (RnB)-II -22 of 2025-26
Open Tender
Civil Works - Buildings
30 days
JAGATPUR
AS PER DTCN
3 documents required · 3 mandatory
₹6,000
₹16,000
Yes
8 Jun 2026
7 Apr 2026
16 Apr 2026
7 Apr 2026
15 Apr 2026
7 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of 125 KVA Silent DG set, Prime Rating at rated rpm 125 (100) kva (kw), Frequency 50 Hz, Power factor 0.8 Lagging, Voltage 415 V 3 Phase, 4/6 Cylinder, 4 Strokes, 1500.00 RPM, Specific fuel consumption (gm/KWh) 200 to 265, Aspiration / Salient features of engine:- Hospital Grade Silencer Turbo charged engine, charged air cooled, direct injection fuel system, no derating applicable upto 4,500 above MSL of altitude at 25 degree celcius, Efficiency at rated Power factor at 75% of full load:- 92.8%, Alternator IP rating :- IP 23, Insulation Class- H, Max time to build up rated voltage at Raterd RPM:-<6 Second provided Engine reach the rated speed, Battery capacity:- 100AH, Displayed parameters / features:- Engine speed, lube oil pressure, coolant / cylinder head temperature, engine running hours, engine battery voltage, engine running status, generator voltage (ph-ph), generator voltage (Ph-N), generator current(R, Y, B), generator apparent power (kVA), generator active power (kw), powerfactor, frequency, event log, control supply voltage, Low lube oil pressure, high water / coolant / cylinder head temperature, over speed, AMF Control Panel, coupled to 125 KVA Cummins/Crompton Greaves/kirloskar/Leroy Somer, 3 phase 415V, 50 Hz alternator mounted on a common Base frame along with other accessories i.e. Fuel tank, Battery and leads, AMF Control Panel, Hospital Grade Silencer, First fill of lube oil, AVM Pad, Acoustic Enclosure with 100 lirs Diesel. (Make:- Mahindra/kirloskar/Jakson) | 1 | No | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | PCC Foundation for suitable 125 kva DG set L 15 ft x W 5 ft x H 2 ft. with Square GI Pipe Shed | 1 | Job | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Supply of 95 mmsq. 3.5 Core 1.1KV Grade ISI Marked pvc insulated pvc sheathed XLPE Alluminium Armored power Cable With End Termination. (Make-Polycab /Havells/KEI) | 62 | Mtr | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | Supply and laying of 2 inch HDPE PVC PIPE ISI Marked complete in all respect as per direction of Engineer in charge (Make:- AKG/ Sudhakar) | 45 | Mtrs | - | - | BI01010001010000000000000515BI0100001115 |
| 5 | Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm direct in ground in the existing RCC/ HDPE/ STONEWARE/ METAL pipe as required. | 60 | Mtr | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | Supply and fixing of 4 pole MCCB 16-100A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) | 2 | No | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | Supply and fixing of Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager) | 1 | NO. | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | Supply and fixing of G.I Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary with charcoal and salt as required. | 2 | each | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Supply of chemical earthing kit consisting of Maintenance free Safe Earthing Electrodes with ISI G.I.pipe dia 60 mm as secondary electrode of wall thickness 3.5 mm and the primary Earthing Electrode will be 32mm x 6mm x 1nos G.I strip filled with a highly conductive & non-corrosive compound in between the primary Earthing and the secondary Earthing, the surface area in mm will be 5,65,200 for 3mtrs.length and Cross Sectional Primary conducting area is 192 sq.mm And solid G.I base plate seals the unit at the bottom.(MES-GFC ground Filling compound will be provided in 25 kgs Bags.) | 2 | each | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | Supplying and laying 25mm X 5mm G.I strip on surface or in recess for connection etc as required. | 25 | Mtr | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
DTCN.pdf
Tender Documents • 1.46 MB
BOQ_587176.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid