| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC R 512 KEGAON BANDHILWADI TAL URAN DISTRICT RAIGAD NAVI MUMBAI 400 702 | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC ADMITTED | |
| 2 | L2₹49.6 L+₹1.5 L (3.12%)Rejected-Finance | L2 | Rejected-Finance Being L2 Rejected | |
| 3 | L3₹49.8 L+₹1.7 L (3.59%)Rejected-Finance 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L3 | Rejected-Finance Being L3 Rejected | |
| 4 | L4₹52.4 L+₹4.3 L (8.92%)Rejected-Finance | L4 | Rejected-Finance Being L4 Rejected |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA URAN RAIGAD MAHARASHTRA
REPAIR TO BLDG REHABILITATION AND EXTERNAL WALL TREATMENT OF CERTAIN BLDGS UNDER AGE B R 2 AT NAVAL STATION KARANJA
2023_MES_610397_1
8689/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW KARANJA
D and above Category a (i)
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
9 Sept 2023
24 Jul 2023
23 Aug 2023
24 Jul 2023
21 Aug 2023
7 Aug 2023
Amount
Notes : (i) The work consists of 04 jobs as under:- JOB (A) : TPP 23-24 Ser no. 53 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
NOTES: The Basic Rate quoted Ser item No 1.02 to 1.32 are deemed to include for the following and nothing extra will be paid for these works: 1. Supplying, erecting and use of scaffolding upto required height (max 25 to 30m) with necessary H-frames, pipes, couplers, buckles, bracing, top platform with support railing at top etc. at all levels of building including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc. complete as per direction of Engineer-in-charge. 2. Supplying, erecting & use of temporary bamboo scaffolding around the building as required. The scaffolding is to be secured properly in position by bracings, ties clamps, etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work all as per direction of Engineer-in-Charge. 3. Supply, fixing & use of dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair work in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system before start of work, removal after completion of work, carrying out regular cleaning etc. complete all as specified and directed 4. Supporting the structural components temporarily during repair and streghthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonallay at centre with each other using suitable heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration, complete as directed by Engineer-in-charge. 5. Guarantee for period of 05 Years (five years) after completion of work.
Chipping , removing carefullly concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete all as specified and directed . Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and M&L for applying two coats of alkaline rust converting primer (FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. or equivalent as approved by GE) on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and directed
M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush complete all as specified and directed. (Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer or equivalent as approved by GE)
M&L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as specified and directed. (Make / brand MONOBOND SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd. or equivalent as approved by GE)
M&L for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 25mm to 30 mm thickness including leveling profliling etc complete all as specified and directed
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes complete all as specified and directed. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and directed. (Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd. or equivalent as approved by GE)
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor (EPCO-KP-100/Protectsil CIT or Ferogard 903 or equivalent as approved by GE). Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed Note:-Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Providing and fixing but 5mm dia and over upto and including 10mm dia additional main steel bar or stirrups of designed diameter in various structural elements like column ,beams and foundations including drilling ,bending, welding and fixing the bars with epoxy putty etc. complete (Steel provided on the basis of 1% of volume of concrete). Note:-Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed
M&L for Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.(Rates including jacketing, formwork and micro concrete)
M&L for new or old external wall surface by wire brushing/grinding in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with mechanical water nozzal with clean water & allow to dry. Fill visible cracks/ joints by crack seal compound and epoxy base joint filler including resin and hardener in proportion as per maufactures instruction & allow to dry for 24 hours. Apply one coat of water base primer (with mechanically airless paint sprayer machine) and allow to dry for 6 hours appx.Thereafter apply 02 coats of WB high build anti caronatin coating cum waterproofing (with mechanically airless paint sprayer machine) & match with brush at the interval of 08 hours between the coat and allow to dry to match the existing shade in camoflauge pattern including or plain paint necessary scaffolding necessary security for the workers for any height, covering etc complete all as per specified and directed. Note:- External water proofing treatment on wall at any height of the building including acrylic paint shall be applied by mechnaically Airless paint sprayer machine only.
Water treatment of chajjas/projected portion : The surface to be free from standing water Prime the surafce with UV stable Polyurethane water proof liquid membrane at 400gm/sqmt dilute with water 1:1 Apply 1st coat of ShaliPrime WP WB at 400gm / Sqmt. Apply 1st coat of UV stable Polyurethane water proof liquid membrane White at 1Kg/Sqmt. Place 40 Gsm Geotextile / FG Tissue as reinforcement followed by 2nd coat of UV stable Polyurethane water proof liquid membrane at 1kg/sqmt. Ensure final curing of 36hrs before carrying any further work. Extend water proofing treatment and terminate at the top of the edge of the parapet wall Seal the Groove using repair mortar complete all as specified and directed
M&L for injection chemical GLYPHOSPHATE (4% Concentration) of 20 ml or till refusal by making cut / injection in the stem of plant of roots at 30 mm and sparaying with solution 25 ml GLYPHOSPHATE (4% concentration diluted with 1 ltr of water) and removing the Plant / vegetation of following girth including penetrated roots complete including necessory scaffolding etc for plants / vegetation of size 0-20 cm girth complete all as specified and directed for buildings upto and including 4 storeys complete all as specified and directed
M&L Silicon gun paste around windows of any type and size incl any height of the building by using scaffolding complete all as specified and directed.
M&L for complete removal of existing treatment from old decorated plastered surfaces of walls by Vacuum based sanding machine complete all as specified, removal of nails etc & filling cracks/hole with putty, applying wall care putty upto 2 mm thick as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats oil emulsion distemper white or coloured over a coat of approved primer by auto roller complete all as specified and directed (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services)
M&L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plaint or camoflage pattern over one coat of primer complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F PVC pipes single socketed in any length with rubber ring joints fixed to wall ( 160mm bore) including flat iron claimp for proper fixing complete all as specified and directed
S&F PVC pipes single socketed in any length with rubber ring joints fixed to wall ( 110mm bore) including flat iron claimp for proper fixing complete all as specified and directed
S&F PVC pipes single socketed in any length with rubber ring joints fixed to wall (75mm bore) including flat iron claimp for proper fixing complete all as specified and as directed
S&F in repairs PVC bends 160mm dia complete all as specified and directed
S&F in repairs PVC bends 110mm dia complete all as specified and directed
S&F in repairs PVC bends 75mm dia complete all as specified and directed
S&F PVC (SWR) branch piece single (single 'Y') equal or unequal 110mm bore complete all as specified and directed
S&F PVC (SWR) branch piece double (single 'Y') equal or unequal 110mm bore complete all as specified and directed
S&F Cast iron 150mm dia rainwater soketed pipes with cement joints, without ears complete all as specified and directed
All as per above BOQ ser No 1.28, but 100 mm dia complete all as specified and directed
S&F for 150 mm bore Bends or elbows, square, or obtuse complete all as specified and directed
S&F for 100 mm bore Bends or elbows, square, or obtuse complete all as specified and directed
S&F 100 mm dia Branch, double fixed complete all as specified and directed
KG ENTERPRISES
SAI ENTERPRISES
Dinesh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .