Tender Value
₹2.6 Cr
EMD Value
₹2.8 L
Closing Date
22 Apr 2025, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time..
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(AnnexureVIB of Tender Documents).
39 conditions · 8 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Power Capacity enhancement by Provision of 3.15MVA 33/11KV power Transformer & improvement of 11KV Power Supply system at TSK 33/11KV Power House and at MXN Power house Improvement of Power supply with shifting of 11KV switch yard.
LV-T-14-TSK-893
LV-T-14-TSK-893
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹2.8 L
22 Apr 2025
31 Mar 2025
88 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,22,98,433.05 | ||
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Power Transformer 3.15MVA, 33/11KV as per IS 2026 or latest amendments ,Copper Wound BIS LEVEL-I, Vector Group: Dyn11, Connection: HV/LV: Delta/Star, HV tapping variation: 5 Nos ,First filling of Transformer Oil as per IS 355 and with all standard accessories. The stardard accesories includes: Name and Diagram Plate, 2 Nos of Lifting Lugs, Oil filling hole with plug, Radiator, Conservator tank, OTI and WTI with marshalling Box,2 Nos of earthing terminal,Drain Valve, Silica Gel Beather, Arching Horn, Air-release plug and Buchholz Relay. | — | — | — | 49,56,000 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Distribution Transformer STEP UP 800KVA, 0.433/11KV as per IS 2026 or latest amendments ,Copper Wound BIS LEVEL-I, Vector Group: YNd11, Connection: HV/LV: Star/Delta First filling of Transformer Oil as per IS 355 and with all standard accessories. The stardard accesories includes: Name and Diagram Plate, 2 Nos of Lifting Lugs, Oil filling hole with plug, Radiator, Conservator tank, ,2 Nos of earthing terminal,Drain Valve, Silica Gel Beather, Arching Horn, Air-release plug . | — | — | — | 18,82,100 | |
| Supply, laying, connection with necessary cable lugs, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size : 630 SQ MM Single Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988 . Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 10,58,400 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of 11 KV, 3 phase GO DO Switch,400 Amps complete with operating handle & one set spare bare fuse . | — | — | — | 54,891 | |
| — | 20.00 | — | — | ||
| Supply, fitting and fixing of GI channel 100x50x6 mm 7500 mm long with necessary clamps size 50 x 6 mm for tubular pole , drilling of holes and all accessories for Double pole stucture. | — | — | — | 68,540 | |
| — | 20.00 | — | — | ||
| Supply, fitting and fixing of GI channel 100x50x6 mm 2000 mm long with necessary clamps size 50 x 6 mm for tubular pole , drilling of holes and all accessories for Double pole stucture. | — | — | — | 18,280 | |
| — | 6.00 | — | — | ||
| Supply, fitting,fixing of GI angle size 50 x50x 6 mm 7500 mm long with drilling of holes and necessary clamps and brackets. | — | — | — | 14,550 | |
| — | 36.00 | — | — | ||
| Supply,fitting, fixing and binding of 11 KV Polymeric PIN Insulator 5KN, complete with large steel head GI pin, nuy, washer etc. as required | — | — | — | 12,456 | |
| — | 12.00 | — | — | ||
| Supply and binding of 11 KV Polymeric Disc Insulator, 70 KN with hardware fittings. | — | — | — | 8,904 | |
| — | 8.00 | — | — | ||
| Erection of Rail Pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. of 9 Mtrs ( Pole will be Supplied by Railway) | — | — | — | 56,616 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of 11 KV, 3 Ph., 50 C/S, 1250 A, 25 KA, Outdoor Type Porcelain Clad Vacuum Circuit Breaker. The Circuit Breakers are required complete with mounting structures, operating mechanism including all associated accessories and auxiliaries. | — | — | — | 9,17,409 | |
| Supply, laying of Copper control cables, multicore round, XLPE Insulated, Cores Laid Up, PVC Innersheathed,Armoured ,Extruded PVC Type ST2 Sheathed, 650/1100 V Grade as per IS 7098 (Part 1) 1988. of size: 10 core 2.5 SQ Mm | — | — | — | 1,24,050 | |
| Supply, laying of Copper control cables, multicore round, XLPE Insulated, Cores Laid Up, PVC Innersheathed,Armoured ,Extruded PVC Type ST2 Sheathed, 650/1100 V Grade as per IS 7098 (Part 1) 1988. of size: 4 core 2.5 SQ Mm | — | — | — | 1,20,750 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of 11KV outdoor tank 1 Phase wound Primary Oil cooled Current Transformer. CTR: 200-100/5-5-5A, Core1: 0.5/30VA , Core 2: 5P10/15VA, Core 3: PS, VK>150-75V STC: 25KA/1 Sec. BIL: 28KV/75KVp. | — | — | — | 2,45,100 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of of 11 KV PT 11KV/0.110KV | — | — | — | 3,00,600 | |
| — | 31.50 | — | — | ||
| Construction of Concrete for Flooring of substation 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)15x7x0.3 =31.5CUM | — | — | — | 2,95,938.09 | |
| — | 72.00 | — | — | ||
| Supply , installation of FRP fencing, non-Corrosive, maintenance free for Transformer switchyard The FRP fencing should be complete with Door and locking arrangement.The Fencing shall be antistatic and ultra violet resistant. Fencing shall be manufactured using components made in accordance with IS-6746 and IS 13410. FRP Fencing shall be made of FRP and shall be corrosion resistant and fire retardant (Low flammability) in accordance with the latest IS-6746. Boundary Of Substation(15x2+5x2)= 40 Mtrs= Fercing Height=1.8= Area= 40x1.8= 72 SQM | — | — | — | 4,31,784 | |
| Supply, laying, connection , testing and commissioning of 11 KV HT(E) , Three Core ,70 SQ. mm compact circular aluminium conductor, conductor screen with extruded semi conducting compound, , XLPE insulated , insulation screening with extruded semi conducting compound in combination with copper tape ( 0.3KA for 1 sec) , cores laid up, innersheath of PVC tape , galvanised steel flat strip armoured , and overall pvc sheathed cable conforming to is 7098 / (part-ii) 1985 with the latest amendments. For cable laying Excavation of earth depth 0.90 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 4,30,000 | |
| — | 1.00 | — | — | ||
| — | — | — | 4,23,803 | ||
| — | — | — | 1,81,342 | ||
| — | 1.00 | — | — | ||
| — | — | — | 1,52,905 | ||
| — | 36.00 | — | — | ||
| — | — | — | 3,38,214.96 | ||
| — | 10.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe , 32x6 mm GI strip- 5 Mtrs,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 52,680 | |
| — | 80.00 | — | — | ||
| Supply, laying of Crushed Stone Aggregate 40 mm nominal size. | — | — | — | 1,08,000 | |
| — | — | — | 1,40,70,626.38 | ||
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Distribution Transformer STEP DOWN 800KVA, 11/0.433KV as per IS 2026 or latest amendments ,Copper Wound BIS LEVEL-I, Vector Group: Dyn11, Connection: HV/LV: Delta/Star, First filling of Transformer Oil as per IS 355 and with all standard accessories. The stardard accesories includes: Name and Diagram Plate, 2 Nos of Lifting Lugs, Oil filling hole with plug, Radiator, Conservator tank, ,2 Nos of earthing terminal,Drain Valve, Silica Gel Beather, Arching Horn, Air-release plug . | — | — | — | 18,82,100 | |
| Boring of 2.6 mtr. underneth Road/Railway track and laying of 200 mm dia HDPE pipe PN 8 for passing underground cable. Supply of the HDPE pipe is included in the scope of this work. | — | — | — | 13,72,800 | |
| Supply, laying, connection , testing and commissioning of 11 KV HT(E) , Single Core ,240 SQ. mm compact circular aluminium conductor, conductor screen with extruded semi conducting compound, , XLPE insulated , insulation screening with extruded semi conducting compound in combination with copper tape ( 0.3KA for 1 sec) , cores laid up, innersheath of PVC tape , galvanised steel flat strip armoured , and overall pvc sheathed cable conforming to is 7098 / (part-ii) 1985 with the latest amendments. For cable laying Excavation of earth depth 0.90 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 11,47,800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .