Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
₹19.3 L
EMD Value
₹38,657
Closing Date
22 Oct 2024, 3:00 pmClosed
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Providing VFD Retrofitting in Blue Star Chiller AC Plant of CSC, IIT Delhi
2024_IIT_830868_1
IITD/WORKS (SP-4775)/2024
Open Tender
Miscellaneous Works
Works
60 days
Indian Institute of Delhi Hauz Khas
As per tender documents
12 documents required · 12 mandatory
₹0
₹38,657
22 Nov 2024
15 Oct 2024
23 Oct 2024
15 Oct 2024
22 Oct 2024
15 Oct 2024
Amount
Supply, installation, retrofitting, testing and commissioning of HVAC Variable Speed Drive of capacity not less than 90 kW / 125 HP suitable for operation on 380 - 480 VAC for controlled operation of 110 TR Water Cooled Chiller AC (Blue Star make) bypassing and keeping standby mode of the existing star-delta drive (starter), complete package with necessary compatible MOBBUS Input / Output card, modification of software compatible to VSD with screw compressor, providing and making connections with communication cable, suitable size of tinned copper power cable (not less than 70 sqmm) of required length including other accessories like master control board (like MCS Magnum extension), control panel accessories including line reactor, transformer, electrical switchgears like DPMCB, control relay, power contactor, line choke, connecting copper cables as required with proper end terminations, solenoid valve, etc. complete as required. The complete package shall be housed in cubicle construction of size not less than 2000 mm x 900 mm x 900 mm fabricated out of 2 mm thick CRCA sheet with hinged lockable doors, dust and vermin proof powder coated of approved shade after 7 tank treatment process with proper forced ventilation arrangement for VF drive complete as required. Safety shutdowns with VSD shall include: a) VSD shutdown - requesting fault data b) VSD - stop contacts open c) VSD - 110% motor overload d) VSD - high phase A, B, C inverter heat-sink temperature e) VSD - high converter heat sink temperature The VSD starter will vary the compressor motor speed by controlling the frequency and voltage of electrical power to the motor. the adaptive capacity control logic shall automatically adjust motor speed and compressor pre-rotation vane position independently for maximum part-load efficiency by analysing information fed to it by sensors located throughout the chiller. The VSD shall restrict harmonic generation from VSD by providing Active Harmonic Filters as per IEEE 519. Drive shall be PWM (Pulse Width Modulation) type utilising IGBTs (Insulated Gate Bipolar Transistor) with a power factor of not less than 0.95 at all loads and speeds. [Suggested make of different accessories: VF Drive - Compatible with Blue Star Chiller (as recommended by OEM Blue Star as per global catalogue / practice), MCB, Contactors - Siemens / L&T / Schneider, Cable - Finolex / Polycab / Havells / Gloster etc.]
CASCADE (BID ID -3107778)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .