| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.5 L+₹4.9 L (17.3%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹34.0 L+₹5.5 L (19.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹34.1 L+₹5.6 L (19.5%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L4 | Rejected-AOC L4 | |
| 5 | L5₹36.8 L+₹8.3 L (29.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
29 Jul 2021, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
Repairs Periodical Maintenance of Stand by DG Sets and connected works at AFA Hyderabad
2021_MES_456143_1
8156/E8
Open Tender
Civil Works
Item Rate
GE (AFA) Hyderabad
As per tender documents
4 documents required · 4 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹90,000
Yes
15 Sept 2021
1 Jul 2021
31 Jul 2021
1 Jul 2021
29 Jul 2021
15 Jul 2021
1 Jul 2021 - 14 Jul 2021
Amount
M&L for the following Periodical Maintenance/Servicing for diesel Gen set installed at AFA for trouble free operation of generator sets and ensuring the serviceability , carrying out minor spares (if any/ settings required for operation of the set shall be carried out without any extra cost for the following capacity Model/ Make by carry out the inspection /work by an authorized service centre including within Two months from the date of commencement and once in every three months subsequently. Engine Maintenance (i) Changing the lubricant oil (ii) Checking the oil level in the oil both air cleaner if required (iii) Checking of alternator, checking/changing fan belt if required (iv) Checking of circuits of various controls of engine (v) Draining the water seperator bowels to remove water/sediments (vi) Checking and tightening of all external fasteners (vii) Checking and tightening of all lube and fuel/hose connections (viii)Changing of fuel filter, Lub oil filter and Air filter if required (ix) Arresting all water /lubricant/fuel leakages and topup (x) Checking of all engine parameters (xi) Checking of the electrical exitation system (xii) checking all the performance of AMF panel in all respect
Note: (i) All repairs/periodical maintenance shall have to be carried out by the authorised service personnel (ii) M&L for spares, lubricant etc required for engine, alternator & AMF panel will be measured and paid separately under relevant items.
Upto 62.5 KVA capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 62.5 KVA and upto 125 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 125 KVA and upto 320 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 320 KVA and upto 500 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 500 KVA and upto 625 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Supply and fixing of Engine Oil seal and gasket for the DG Set of the following Capacity including removal of old u/s gasket and oil seal including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 62.5 KVA and upto 125 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 125 KVA and upto 320 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 320 KVA and upto 500 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Above 500 KVA and upto 625 KVA Capacity DG Set of Make:Kirloskar/Cummins/Greaves
Supply and fixing in Repair of V belt for following Capacity DG sets including removal of old u/s V belt including connection up complete all as directed by Engr-in-Charge Make : Fenner, Finex supreme.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Ammeter suitable for following Capacity DG sets including removal of old u/s Ammeter including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of oil pressure guage for following Capacity DG sets including removal of old u/s oil pressure guage including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of speedometer cable for following Capacity DG sets including removal of old u/s speedometer cable including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of push button switch for stop/start of DG engine for following Capacity DG sets including removal of old u/s push button switch including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Ignition switch for following Capacity DG sets including removal of old u/s Ignition switch including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Lub Oil filter set for following Capacity DG sets including removal of old u/s Lubrication Oil filter set including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Diesel filter set(Primary and Secondary) for following Capacity DG sets including removal of old u/s Diesel filter set including connection up complete all as directed by Engr-in-Charge
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Air filter set (Inner and Outer) for following Capacity DG sets including removal of old u/s Air filter set including connection up complete all as directed by Engr-in-Charge
Above 500 KVA and upto 62.5 KVA Capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Universal multi function relay in AMF panel of DG set for following Capacity including removal of old u/s relay including connection up complete all as directed by Engr-in-Charge
Above 500 KVA and upto 62.5 KVA Capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply and fixing of Power contactor 4 pole of capacity 800 A with auxiliary contactors of 2 NO's and 2 NC's confirming to TC contactors of equivalent in ABB, L&T schneider, C&S suitable for AMF panel of 625 KVA DG set complete all as directed by Engr-in-Charge
S&F of Power contactor 4 pole of capacity 600 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 320 KVA DG set complete all as directed by Engr-in-Charge
S&F of Power contactor 4 pole of capacity 400 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to TC contactors or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 160/250 KVA DG set complete all as directed by Engr-in-Charge .
S&F of Power contactor 4 pole of capacity 200 to 250 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 100 KVA DG set complete all as directed by Engr-in-Charge
S&F of Power contactor 4 pole of capacity 150 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to MEC LS Model GMC-180/4 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 50/63 KVA DG set complete all as directed by Engr-in-Charge
S&F of Power contactor 4 pole of capacity 63 A with auxiliary contactors of 2 NOs' and 2 NCs' confirming to L&T Model MCX11 or equivalent in ABB, C&S, Schneider, L&T suitable for AMF panel of 15/30 KVA DG set complete all as directed by Engr-in-Charge
M&L for filling/topup of distilled water for the batteries of the DG Sets all as directed by Engr-in-Charge
M&L for remove the unserviceable self starter 24 volts DC LUCAS make from Gen set of DG set including removal of un serviceable solenoid ,worn-out bentex, clutch plate etc supply and fix new clutch plates, bentex, contact point assembly, solenoid, minor parts like nuts, bolts washers etc including necessary lathe work, servicing and fixing testing and commissioning for smooth operation all as directed
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
M&L for remove the unserviceable winding of self starter 24 volts DC LUCAS make from Gen set of following capacity DG set including rewinding of un serviceable burnout winding and Supply and fixing High conductivity best quality super enamelled copper winding back in position all as directed by Engr-in-charge for following capacity DG sets.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Note:- Winding material will be measured and paid seperately under relevant item
S&F in repairs new armature with brushes and brush holder for dynamo of following DG set capacity including removing the burnout armature , clean the internal surfaces ,servicing, supply and fix new armature with brushes and brush holder, necessary lathe work to the bushes, shaft etc all as directed
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply only Coolant suitable for Diesel generating sets of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for Painting of the following DG set after preparing the external surface apply one coat of primer and spray painting by superior quality enamel paint connected panel etc including Engine, Alternator, canopy, base frame, radiator, battery stand, connected etc and all as directed by Engr-in-Charge.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Removing the unserviceable Diesel level indicating plastic pipe of approx size 10 mm dia and both end clamps and replace with new Plastic pipe of same size to the required level and clamps on both the sides complete all as specified and directed by Engr-in-Charge
Remove the radiator from the gen set drain out the coolant servicing, arresting leakages by welding/brazing etc, supply and replacing the u/s mounting rubber, clean the internal surfaces and de-scale by using cleaning agents and fixing back in position complete all as directed by Engr-in-Charge for the following capacities:-
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Material and labour for repairs to the following DG Set alternator and removing the same from engine of DG Set, transporting the same to the work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note:- Copper winding material will be measured and paid seperately under relevent item
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Remove the fuel injection pump from the engine transport to an authorized service centre for servicing, calibration and to adjust by replacing the following U/S worn-out spares with new appropriate make spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for following capacity DG set:- Note:- Major spares required will be measured and paid seperately:
All as per item No 27 above but Upto 62.5 KVA capacity
All as per item No 27 above but bove 62.5 KVA and upto 125 KVA Capacity
All as per item No 27 above but Above 125 KVA and upto 320 KVA Capacity
All as per item No 27 above but Above 320 KVA and upto 500 KVA Capacity
All as per item No 27 above but above 500 KVA and upto 625 KVA Capacity
Supply only orifice for following capacity DG set
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply only Barrel and Plunger for following capacity DG set
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
Supply only FIP Bearing for following capacity DG set
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair Neon type indicating lamp
S&F in repair Rewinding of Exhaust fan for 15KVA to 62.5 KVA DG Set (Mounted on canopy)
S&F in repair HRC Fuse 15KVA gen set
S&F in repair HRC Fuse 100KVA gen set
Supply and fixing of HRC Fuse 320 KVA
S&F in repair Solonoid switch for Auto stop AMF Panel
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair Generator controller unit-GCU101 for upto 62.5 KVA DG Set AMF Panel Make: CE,Utopia atomation control/Kirloskar
S&F in repair Generator controller unit-RS232 Serial connector 8 to 35 vdc, 300 mA max for suitable to existing 320KVA to 400 KVA DG Set AMF Panel Make: CE,Utopia atomation control/Kirloskar/cummins
S&F in repair Power Command HMI211 model suitable to 160 KVA to 200 KVA DG set AMF Panel as per sample Make: CE,Utopia atomation control/Kirloskar/cummins
S&F in repair Power start P5500 controller model suitable to 100 KVA DG set AMF Panel as per sample Make: CE,Utopia atomation control/Kirloskar/cummins
S&F in repair MCCB 32 Amps 3 pole, model DU 100 suitable upto 62.5KVA DG set AMF Panel Make L&T, Schneider, Havells, C&S, ABB, Legrand.
S&F in repair MCCB 125 Amps 4 pole, model DPX3 160 suitable to above 160KVA to 400 KVA DG set AMF Panel Make L&T, C&S, Havells, C&S, ABB, Legrand.
Taking out existing outlived old engine clean the engine oil sump and filling/ Top up engine oil 20 W 40 to DG Sets of capacity 15 to 625 KVA all as directed Make : Servo/Castrol/Valvoline
S/F in Repair U/S water pump from the Engine carry out necessory dismantling and Repair with new water pump Repair kit Refixing the same to the Engine necessory testing commissioning and Entire satisfaction of engr in charge.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S/F in Repair of DG set Existing Damaged doors i.e Left & Right side Door hinges and door lockers with keys and fixing as per existing sample Kirloskar/cummins
from 15 KVA to upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable IEVR - II ( industrial electronic voltage regulator) Kirloskar alternator / alternator control panel and S/F of new IEVR - II (Make: Kirloskar Electric) to match with the existing, connecting complete and all as directed and as specified.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair of electronic control panel governor for DG Set part no-4083935 make.kirloskar/cummins all as directed and specified.
Above 200 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable Sensor Unit for engine safety control unit (precol panel assembly) from the engine of upto 100 KVA Kirloskar DG Set to match with the existing and connecting complete and all as directed and as specified.
All as per item no 45 above but but above 100 KVA to upto 320 KVA DG set
M&L for rewiring to panel board of DG set upto 100 KVA with PVC insulated multistanderd copper conductor cable single core 1100 volt grade 10 sqmm complete with thimble lugs as required and directed and as specified
All as per item no 45.02 above but above 100 KVA to upto 320 KVA DG set
S/F in repair Alternator AVR (automatic voltage Regulator) card for 15 KVA to upto 60 KVA DG set as per sample for kirloskar/ cummins Make:Stamford
All as per item no 46 above but above 62.5 KVA to upto 320 KVA DG set
S&F in repair of AMF panel contactor coil MCX3 Model for 15 KVA to 60 KVA make:L&T
S&F in repair RRA (Rotating Rectifier Assemly) for 15KVA to 30 KVA Make Kirloskar/ cummins
Opening of tappet cover and carrying out necessary adjustments of the tappets, push rods, rocker arms etc, upto 625 KVA Kirloskar / Cummins engine, including S/F of set of Gasket set, minor spares including refixing and testing complete all as directed and as specified.
S&F in repair of unserviceable Anti Vibration pad for 200 KVA DG Set and S/F of new Anti Vibration pad for 200 KVA DG Set to match with the existing, connecting complete and all as directed and as specified.
S&F in repair of unserviceable Module Electronic Control Model No CM2880 and S/F of new Module Electronic Control Model No CM2880 for 200 KVA DG Set to match with the existing, connecting complete and all as directed and as specified.
S&F in repair of unserviceable VMR 3 P ( Voltage Monitoring Relay Protection of 3 Phase) (REL ) Model No PR-07 for DG Set and S/F of new VMR 3 P (REL ) Model No PR-07 to match with the existing, connecting complete and all as directed and as specified.
Above 62.5 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 320 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable Fuel water separator filter for DG Set and S/F of new Fuel water separator filter to match with the existing, connecting complete and all as directed and as specified.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable Super bypass filter for DG Set and S/F of new Super bypass filter to match with the existing, connecting complete and all as directed and as specified.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable VSP D2 (Phase failure relay) for DG Set and S/F of new VSP D2 (Phase failure relay) to match with the existing, connecting complete and all as directed and as specified.
Upto 62.5 KVA capacity
Above 62.5 KVA and upto 125 KVA Capacity
Above 320 KVA and upto 500 KVA Capacity
Above 500 KVA and upto 625 KVA Capacity
S&F in repair of unserviceable PCB Assy for DG Set of capacity 320 KVA to 625 KVA and S/F of new PCB Assy to match with the existing, connecting complete and all as directed and as specified.
Taking down of Turbo charger assembly from the 320 to 625 KVA Kirloskar/Cummins engine and carrying out cleaning and overhawling including providing minor spare parts/ Repair kit and Refixing out Testing complete for optimum out put of the engine and all as directed and as specified.
Taking out old unservciceable burnt out copper winding wire from for the Item no 21 and 26, Rewinding with supper enameled copper wire as per existing guages and turn with necessary heats, varnishing to achieve insulation Resistance to required mega ohms all as specified and directed
Supply & Fixing battery terminal lead including terminals (Positive) and necessary lugs.
Supply & Fixing battery terminal lead including terminals (Negative) and necessary lugs.
M&L for draining out complete fuel from the tank and taking out the tank from the base for removing the rusted sludge by scrubbing the internal surface with wire brushes. After cleaning the tank re-install back in position and connection with other accessories complete all as specified and as directed by Engr- in -Charge.
M&L steel tubing fuel pipe of 625 KVA DG set as per existing size from fuel tank to fuel filter of DG set alongwith all accessories for fitting and welding as required including taking down old unserviceble fuel pipe complete all as specified and as directed by Engr- in - Charge.
SREE KIRAN ENGINEERS
M/s Jai Ganesh Engineering Solutions
DPS sales and services india
Allied Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .