| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.0 L+₹22,680 (2.10%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹11.9 L+₹1.1 L (10.0%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹13.4 L+₹2.6 L (24.3%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
2 Aug 2021, 6:00 pmClosed
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR AND MAINT OF AIR CONDITIONING AND REFRIGERATION SYSTEM AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2021_MES_457286_1
8121/SAR-08/E8 REPAIR AND MAINT OF AIR CONDITIONIN
Open Tender
Civil Works
Works
333 days
GE (AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) SARSAWA
₹40,000
Yes
16 Aug 2021
5 Jul 2021
4 Aug 2021
5 Jul 2021
2 Aug 2021
19 Jul 2021
5 Jul 2021 - 19 Jul 2021
Amount
Supply & fix in replacement Electronic starting circuit relay circuit for 16.5 TR package type AC (As per sample) complete all as specified and as directed.Make Voltas complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Electronic starting circuit relay circuit for 8.75 TR compressor (As per sample) complete all as specified and as directed. Make: Bluestar complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement sealed unit compressor of cap 5.5 TR suitable for package type AC complete all as specified and as directed by Emgr-in-Charge. Make: Voltas
Supply & fix in replacement sealed unit compressor of cap 4.5 TR suitable for package type AC complete all as specified and directed by Engr-in-Charge. Make: Bluestar
Supply & fix in replacement MCCB 100 Amp, 4 pole braking capacity 25 KA , thermal Adjustible complete all as specified and directed by Engr-in-Charge.Make: Schneider/Legrand/L&T
Supply & fix in replacement MCCB 125 Amp, 4 pole braking capacity 25 KA, thermal Adjustible complete all as specified and directed by Engr-in-Charge.Make: Schneider/Legrand/L&T
Supply & fix in replacement MCCB 250 Amp, 4 pole braking capacity 25 KA thermal Adjustable complete all as specified and directed by Engr-in-Charge. Make: Schneider/Legrand/L&T
S&F in replacement Blower/ condensor fan motor of three speed, testing, commissioning complete suitable for window type 1.5 to 2 Ton AC suitable to operate 230V AC complete all as specified and directed by Engr-in-Charge.
S&F in replcement of blower motor suitable for indoor unit rating and capacity as per site requirement for upto 2.0 ton capacity Split type AC complete all as specified and directed by Engr-in-Charge.
All same as per ser item No9 above here in before but suitable for condensor fan of out door unit of split AC up to 2.0 TR capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement Blower fan made out of plastic suitable for window/split type AC upto 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement Condenser fan blade made out of aluminium/plastic as per matching to existing suitable for window split type AC upto 2.0 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement Front grill suitalbe for window type AC upto 2 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condensing coil suitable for window type room AC of capacity 1.5/2 ton as per sample complete all as specified and directed by Engr-in-Charge
S&F in replacement cooling coil suitable for window type room AC of capacity 1.5/2 ton.as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement Condensing coil suitable for split type AC of capacity 2 ton complete all as specified and directed by Engr-in-Charge.
S & F in replacement cooling coil suitable for split type AC of up to capacity 2 ton complete all as specified and directed by Engr-in-Charge.
S&F replacement of Indoor unit suitable for 1.5 TR split type AC. Make:- LG/VOLTAS/DAIKEN complete all as specified and directed by Engr-in-Charge.
S&F replacement of Outdoor unit suitable for 1.5 TR split type AC without compressor. Make:- LG/VOLTAS/DAIKEN complete all as specified and directed by Engr-in-Charge.
M&L in replacement PCB for window/Split type AC up to 2 Ton capacity suitable for existing make complete all as specified and directed by Engr-in-Charge.
Suuply & Fix in replacement of genuine sealed compressor any type of existing make for split/ window type AC capacity 1.5 Ton with all fixing accessories complete all as specified and as directed by Engineer-in-charge. Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM.
All same as per ser item No.21 here-in-before but of split/ window type AC capacity 2.0 Ton complete all as specified and directed by Engr-in-Charge.
S&F in replacement Running Capacitor of 06-45 Mfd suitable for window / split type AC complete all as specified and directed by Engr-in-Charge. Make Tibcon/ Epscos
S&F in replacement Wiring kit suitable for 1.5 to 2.0 ton capacity AC complete complete all as specified and directed by Engr-in-Charge.
S&F in replacement Air filter of existing make : synthetic, PVC suitable for 1.5 to 2.0 ton capacity AC window/Split type complete all as specified and directed by Engr-in-Charge.
S&F in replacement Refrigerant gas filter and capilary assembly complete suitable for AC upto 2 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement gas charging pin valve complete all as specified and directed by Engr-in-Charge.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another locatiion in the same or other building in the complex as directed complete with make opening of suitable size in wall/window as per site requirement complete all as specified and directed by Engr-in-Charge.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and discharge copper pumping and shifting to another locatiion in the same or other building in the complex complete all as specified and directed by Engr-in-Charge.
Supply and charging the gas refrigerant (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, injection of nitrogen to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed by Engr-in-Charge.
All same as per item No 30 here-in-before but split type AC up to 2 TR capacity complete all as specified and directed by Engr-in-Charge
M&L for replacement of split valve ¼” for split AC 1.5 ton capacity complete all as specified and directed by Engr-in-Charge
All same as per item no 32 above here in before but 1/2" complete all as specified and directed by Engr-in-Charge
S&F in replacement compressor shut off valve 3/8" for window AC 1.5 ton capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement compressor shut off valve 3/8" for split AC 1.5 ton capacity complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Copper tubing of size 1/4" suitble for any type of split type AC complete all as specified and directed by Engr-in-Charge.
All same as per Ser item No. 36 but size 1/2" complete all as specified and directed by Engr-in-Charge
All same as per Ser item No. 36 but size 3/8" complete all as specified and directed by Engr-in-Charge.
All same as per Ser item No. 36 but size 5/8" complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC pipe to drain out flexible condence water pipe suitable for any type of AC including necessary clamping arrangement to wall complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC conduit 50mm dia including all clamps, tees & accessories and connecting the condensate pipe of Acs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed by Engr-in-Charge. MAKE- AKG/National
S&F in replacement of synthetic rubber tube for thermal insulation for refrigerant copper piping of size 1/4" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes complete all as specified and directed by Engr-in-Charge. MAKE- KAIFLEX
All same as per ser item No. 42 but size 1/2" complete all as specified and directed by Engr-in-Charge
All same as per ser item No. 42 but size 3/8" complete all as specified and directed by Engr-in-Charge
All same as per ser item No. 42 but size 5/8" complete all as specified and directed by Engr-in-Charge
S&F in replacement of window AC kit complete chasis including cooling coil, condensing coil, fan motor, blower, condensing fan and complete body without compressor suitable for window AC of capacity upto 2.0 ton complete all as specified and as diretced by Engineer-in-charge
S&F in replacement of remote for window / split type AC as per matching existing complete all as specified and directed by Engr-in-Charge
S&F in replacement of condensate water collecting tray for window AC installed in bldg upto 5 storey complete all as specified and directed by Engr-in-Charge
S&F in replacement metal plug top 2 pole and earth, 20 Amps, 250 volts suitable for sheet metal enslousers complete all as specified and directed. MAKE - L&T/Halells/Legrand
S&F in repalcement metal clad socket 2 pole and earth, 20 Amps 250 volts suitalbe for sheet metal enclosurs complete all as specified and directed by Engr-in-Charge. MAKE - L&T/Halells/Legrand
S&F in replacement MCB single pole, 6-32 Amps, 10 KA 240 Volts, 50 HZ type. C series complete all as specified and directed by Engr-in-Charge. MAKE - L&T/Halells/Legrand
S&F in replacement sheet metal enclosure single pole and neutral with 2 pin and earth socket complete with one single pole MCB 6- 32 A, 10 KA 'C' series complete all as specified and directed by Engr-in-Charge. MAKE - L&T/Halells/Legrand
S&F in replacement of PVC insulated sheathed flexible copper conductor 3 core 1100 volts round grade of size 2.50 Sqmmcomplete all as specified and directed by Engr-in-Charge. Make RR KABEL/Havells/Finolex
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts round grade, 3 core of size 1.5 Sqmm complete all as specified and directed by Engr-in-Charge.Make RR KABEL/Havells/Finolex
S&F in replacement of PVC insulated flexible copper conductor single core 1100 volts round grade of size 2.50 Sqmm complete all as specified and directed by Engr-in-Charge.Make RR KABEL/Havells/Finolex
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, single core of size 1.5 Sqmm complete all as specified and directed by Engr-in-Charge. Make RR KABEL/Havells/Finolex
M&L in replacement sub main wiring with two run of single core strated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as specified and directed by Engr-in-Charge. Make RR KABEL/Havells/Finolex
M&L in replacement sub main wiring with two run of single core strated copper conductor cable of size 4 Sqmm and 4 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete complete all as specified and directed by Engr-in-Charge. Make RR KABEL/Havells/Finolex
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacityany type complete with fastners stove enamelled complete all as specified and directed by Engr-in-Charge.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed by Engr-in-Charge.
Supply and charging the green gas in the water cooler of any make and capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specified and directed by Engr-in-Charge.
S&F in replacement thermostat switch for water cooler of any make & size complete all as specified and directed by Engr-in-Charge.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed by Engr-in-Charge.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of zinc oxide primer by spray painting complete all as specified and directed by Engr-in-Charge.
S&F in replacement fan motor ISI marked suitalbe for water cooler capacity upto 40/80 ltrs of any make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of condenser fan of any make suitable for water cooler upto 40/80 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement 15 mm dia PTMT connection of length upto 600mm with nuts on both ends complete all as specified and directed by Engr-in-Charge.
S&F in replacement condenser coil suitable for water cooler upto 40/80 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 40/80 ltrs capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement company sealed compressor unit of water coolers of capacity 40/ 80 ltrs complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Cooling coil complete with cooling chamber of refrigerator of capacity 320 Ltrs complete all as specified and directed by Engr-in-Charge.
S&F in replacement of compressor for refrigerator of capacity 310 Ltrs as per matching to existing. Note : Repaired and repainted compressor not accepted only genuine compressor are accepted complete all as specified and directed by Engr-in-Charge. Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM.
M&L for repair to refrigerator any capacity upto 310 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified and directed by Engr-in-Charge.
S&F in replacement of compressor for deep freezer of capacity 320 Ltrs as per matching to existing. Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted complete all as specified and directed by Engr-in-Charge. Note : Repaired and repainted compressor not accepted only gnuine compressor are accepted. with test report and year warranty certificate from OEM.
M&L for repair to deep freezer any capacity upto 320 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified and directed by Engr-in-Charge.
M&L for Servicing of voltage stabilizer AC single phase 2 to 5 KVA of any make by opening of body, cleaning internally checking and tightening of all terminal connections including replacement of worn out terminals connectors, screw, bolts etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement of transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of buck and boost relay of voltage stabilizer of capacity upto 5KVA complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of electronic panel PCB of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of timer switch circuit of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of trigger transformer of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement of voltmeter of voltage stabilizer of capacity upto 5 KVA as per matching to existing, complete all as specified and directed by Engineer-in-charge. Note for ser item No. 1 to 83:- 1. The contractor shall provide and deploy sufficient technician with helpers (as approved by GE / Engineer-in-charge) for maintenance of summer appliances at Tech Area and domestic area and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints & complete the same complaint detailed by JE E/M /Engineer-in-charge with in 24 hrs. 2. The complaints shall be rectified with in 24 hrs. If the complaints is/are not complete on same day (except repair/ replacement of major items like repair/ replacement of compressor, cooling coil, condensing coil, fan motor ducting work of AC plant & insulation work. these work can be completed in time period (max 36 Hrs) as decided by Engineer-in-charge after which recovery shall be made as under), the recovery will be done as follows (a) After 24 Hrs Rs - 1000.00 Per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station Sarsawa 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
M/S PRABHUKESHVAM (OPC) PRIVATE LIMITED
MAHADEV ELECTRICALS
SHRI RAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .