Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹35.2 L+₹2.6 L (7.82%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹37.8 L+₹5.1 L (15.7%)Rejected-Finance 93 4 16A BLOCK NO 3 JAWAHAR CHOWK PACHMARHI MP 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹39.0 L+₹6.3 L (19.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹40.2 L+₹7.6 L (23.2%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
29 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR JABALPUR 482001
PROVISION OF SINGLE LIVING ACCOMMODATION FOR 01 X JCO AND 06 X OR WITH BATHROOM AND TOILET WITH URINAL AT NFS NODE PACHMARHI MIL STATION UNDER AGE (I) PACHMARHI
2024_MES_652173_1
83239/E8
Open Tender
Civil Works
Item Rate
270 days
PACHMARHI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
AGE(I) PACHMARHI
₹84,000
Yes
23 Jul 2024
3 May 2024
31 May 2024
3 May 2024
29 May 2024
17 May 2024
3 May 2024 - 16 May 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out all kind of soil the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed.
Excavation for taking out/laying cable in trenches in soft/loose soil not exc 1.5 m wide and not exceding 1.5 m deep for LT 1100 V under ground cable complete all as specified and directed .
Returning filling in including spreading levelling, watering and well ramming in layers n exc 25 cm complete all as specified and directed .
Removing excavated materials n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed .
Providing and injecting chemical emulsion for pre-construction Antitermite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed .
Providing and injecting chemical emulsion for pre-construction Antitermite treatment for the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
Providing and injecting chemical emulsion for pre-construction Antitermite treatment for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed .
Providing and injecting chemical emulsion for pre-construction Antitermite treatment for ATT Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed .
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone as in foundation /sub base of floor, filling and mass concrete complete all as specified and directed .
M&L for RCC (design mix) M25 ( 20 mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beam, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (design mix) M25 ( 20 mm graded crushed stone aggregates) as in Columns, pillars, peirs, posts, and struts complete all as specified and directed.
M&L for RCC (design mix) M25 ( 20 mm graded crushed stone aggregates) as in Beams , cantilivers , bressummers , lintles over 1.5 M span complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beam, sides and soffits(if any) of foundation and plinth beams and similar work, vertical or to batter surfaces for rough finished flat surfaces of concrete, complete all as specified and directed.
Formwork rough finished surface of concrete as in Square, rectangular or polygonal to sides of columns, pillars, posts, struts, piers etc.complete all as specified and directed.
Formwork to sides and soffits of floor or roof beam, beam hauchings, bressummers, lintels, shelves etc. including supports, overhangs, etc, complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia as in stirrups, spacers and binders for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Material and labour modular brick work in with fly ash brick bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and as directed
M&L for precast cement concrete slab type B-1, 1:2:4 using 20mm graded aggregates as in manholes cover slab set in cement mortar 1:6 complete all as specified and as directed
Supply and fix pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150)corrugated steel sheet of any colour having minimum tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ L or J type or cranked hook/ bolts as complete all as specified & directed.
S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick(AZ-150) plain steel sheet of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length & girth as fixed) fixed with self tapping screws complete all as specified & directed.
S&F Mild steel flat iron as in wind ties including cutting drilling holes and securing bolts confirming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or including butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed.
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
S & F rolled mild steel plates ( plain on chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment conforming to Fe 410 W (Gde E. 250) quality ‘A’ complete all as specified & directed
M&L 10 mm thick internal plaster in CM(1:6) finished even &smooth with trowel without using extra cement complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar (1:4) , in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound as per Manufacturer's instructions and finished the surfaces even and fair without using extra cement complete. (Note : Liquid WPC will be measured and paid separately as "Supply only".)
M&L for applying two coats of cement base paint on wall or concrete over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete.
Supply only liquid water proofing compound ISI Marked, of make as approved by AGE(I) complete all as specified & directed.
M&L for applying two coats of oil bound distemper on wall or concrete over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete.
M&L for 75mm thick PCC (1 :3 :6) type C1, (using 20mm graded crushed stone aggregate ) as in plinth protection / floor finishes surface with using extra cement.
M&L for broken stone/boulders for hardcore of gauge nexc 63 mm, deposited, spread and levelled in layers nexc 15 cm thick in two layers watered and rammed to true surface.
M&L for 100mm thick PCC 1:4:8 type D-2 using 40 mm graded stone as in sub base of floor.
M&L for vitrified light shade tiles in floor of size 600mmx600mmx10mm thick of approved colour laid over and including 15mm thick screed bed in CM 1:6 jointed and pointed with approved materials as per manufacturers instructions complete all as specified and directed.
M&L for non skid, joint free, coloured ceramic tiles 7-8mm thick (Square/Rectunglar), area of each tile exc .06Sqm But not exc .11 Sqm etc set in floor and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles laid with and including over 15mm thick screed bed in CM (1:4), area of each tiles shall be of following complete all as specified and directed :-
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over & including 10mm thick plaster in CM 1:4
M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads single piece of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above.
M&L for 40 mm thick damp proof course in cement cocrete ratio 1:2:4 type B0 to horizantal surface including neccesary formwork complete all as specified and directed.
S&F tubes 15 mm bore "medium grade" with all fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed.
S&F tubes 20 mm bore "medium grade" with all fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed
Supply and fix 500 ltrs capacity rotational moulded polyethylene water storage tank double layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed.
S&F Ball brass valves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore pipe .
S & F 20 mm dia gun metal or gate valve with ironwheel head screwed both for iron pipe and fixed
S&F vitreous china wash down water closet pan (Pedestal pattern)white including fixing bolt and plastic water closet seat white closed pattern with flat bottom cover with MS chromium plated hinging devices to matching colour.
Supply only PVC valveless, syphonic action type 10 ltrs flushing cistern low level white with inlet, ball valve float and handle incl brackets complete all as specified & directed.
Supply only PVC connection 15mm size with PTMT nut of length 450mm
S&F 15mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F vitereous china wash basin, white flat back, size 550x400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, incl 32 mm dia brass CP waste fittings (coupling) including 32 mm waste pipe. complete all as specified and directed.
Supply only 15mm dia pillar taps cast copper alloy chromium plated ,screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe (bore of pipe 15mm) complete all as specified and directed.
S& F brass chromium plated tubular towel rail 20mm dia D type, 60 cm long between flanges complete all as specified and directed .
S&F Bib tap 15mm bore fancy type chromium plated , cast copper alloy with crutch or butterfly handle screwed down for iron pipes complete all as specified and as directed.
S&F for Brass chromium plated shower rose 125mm size Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
Vitreous China urinals, half stall type, complete including providingand fixing plugs, bedding urinalagainst wall in cement mortar 1:2, securing urinal to plugs withand including 60mm long brassscrews, pointing urinalback in cement; fixing automaticflushing cistern with brackets,flush pipe,grating and Union fordischarge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F for 15 mm bore fancy type Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed
S&F for Soap dish, any type, fixed to plugs with chromium plated brass screws
M&L for factory made 35mm thick second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, framed, panelled shutter (two or three panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm thick veneered particle board with commercial veneering on both faces; size of rail and stiles as per IS: 1003 (Part-I), kiln seasoned complete all as specified & directed.
M&L for IInd class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified & directed.
M&L for factory made second class (Indian Sal, Bijasal, Hollock or Benteak) hardwood glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) and fitted to chowkats complete all as specified & directed. Notes:- (i) glazing will be measured and paid for separately. (ii) Butt hinge will be measured and paid for separately .
M&L for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
M & L sheet glass ordinary quality 5.5 mm thick and glazing with oil putty in squares n.exc. 0.5 sqm each pane Complete all as specified.
M&L applying two coats of synthetic enamel paint over a coat of pink primer to new wooden surfaces exc 10 cm width or girth, including preparation of surfaces, complete all as specified and directed.
M & L preparation of new surfaces of any description not otherwise described over 10 cm width or girth of steel surfaces at any height and applying two coat of synthetic enamel paints complete all as specified & directed.
M&L Aluminium powder coated (powder coated of requried colour) three track sliding windows frame top & sides of size 92x31.75x1.50 mm (section No 20831), bottom size 92x31.75x1.50mm (section No 20832) and shutter top & bottom of size 40x18x1.55mm (section No 20736) and sides (handle) of size 40x18x1.55mm (section No 20738) and lock side shutter frame of size 40x18x1.45mm ( section No 20737)" with including and fixing rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including & fixing stainless steel wire mesh 0.36mm nominal dia of wire with 1.40mm average aperture and fixed with stainless steel wire staples and including and fixing 5mm thick glass with necessary rubber beading gasket etc including necessary plaster, painting ,cill and making good to disturbed portion all as specified and as directed by Engr-in-charge
S&F aluminium powder coted ventilator louvers type frame top and bottom of size 31x42x1.60mm(sec no-20558) rectaular tube of size 40x20x2 mm (sec no-14019 and middle verticalof size 42x46.20x1.60mm sec(20560) and clip for fixing wiremesh and glass of size 19x17.30x0.90mm (sec no-19360)thick including and fixing stainless steel wire cloth 0.36mm niminal dia of wire and 1.40mm average width of aperature and fixed with stainless steel wire staples and supply and fixing 5mm thick louvers with blades of 100 mm heavy duty with neccessary rubber beading ,gasket etcincluding necessary plaster, painting ,cill and making good to disturbed portion all as specified and directed by Engr-in-Charge
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube supplying & fixing in opening as per specified & drawing.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F in Harrison rails, anodised aluminium alloy , chromium plated with fixing brackets, stops, rollers et
S&F 125 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as spd.
S&F 200 mm long aluminum anodised barrel tower bolts of extruded section as specified.
S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified.
S&F for sliding door bolt of Aluminium alloy anodised 250 mm complete
S&F PVC (SWR) bends any radius provided with access door of 75 mm dia
S&F PVC (SWR) junction single,(Single T) (equal or un equal) , of 110 mm dia with access door
S&F PVC (SWR) multi floor trap, plain with grating with or without waste hole including jointing with solvent cement 75mm dia etc complete
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete.
M/L PVC(SWR) bend of 110mm dia of any radius etc complete all as specified and directed
S &F 75mm bore (SWR) pipe single socketed in any length with rubber ring joints,fixed to walls
S&F 75mm bore PVC (SWR) vent cowl
S&F 75 mm bore PVC (SWR) bend of any radius
M&L preparation of new or previously untreated steel surface of any description n. exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & labour for Precast reinforced cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including ar?rangement for fixing of hinges and fixtures as required complete all as specified and directed.
S & F stack clamps out of 100 mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof.complete all as specified & directed.
Supply and fixing PVC waste pipes of 40/32mm bore suitable for wash hand basins/sinks complete all as specified & directed.
S&F Urinal spreader as in repair of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified & directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting exc 10 cm but not exc 20 cm girth all as specified.
M&L for suspended false ceilling comprising of 6mm thick non asbestos fibre cement bulding boards fixed or laid/inserted to GI frame work with screws over Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Forming 12 mm thick expansion joints filled withpre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified & directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out in hard/dense soil complete all as specified & directed.
M&L for 100mm thick PCC, type D2 (1:4:8) using 40mm graded stone aggt in foundation, fillings and mass concrete complete all as specified.
M&L for coloured Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 grade of concrete laid over and including 50mm thick sand cushioning complete all as specified and directed.
M&L for PCC 1:2:4 type C-1 12.5mm graded stone aggregate in coping and like including . weathering slightly rounded /chamfered angles with and including . necessary use and waste of form work for fair faces of concrete complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5M depth for foundation in soft / disintegrated rock and getting out complete all as specified abd directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone agg) as in Man hole channel and surface drain slightly rounded or chamfered angles etc complete all as specified.
Extra for Forming fair finished channel 30 cm inner girth in cement concrete using extra cement including mitered stopped ends etc complete.
M & L for laying DWCP 150 mm dia pipes in trenches class SN-8 conforming to IS 16098 ( part - 2) in 6 mtr length with coupler complete all as specified abd directed
M&L for Concrete bed to drain pipes including packing under, and completely surrounding pipes with concrete after they are laid and tested in cement conrete 1:3:6 type C-2 around 150mm dia complete.
M&L for RCC 1:2:4 Type B-1 (using 20mm graded stone agg) as in top of manhole for fixing covers and the like including weathering slightly rounded/chamfered complete.
M&L form work to edges of concrate flats, treads, breaks in floors, and roof n.exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick work and finished the surface fair and even without using extra cement complete as specified and directed
M&L for PCC 1:2:4 type C-1 12.5mm graded stone aggregate in coping and like including weathering slightly rounded /chamfered angles with and incl. necessary use and waste of form work for fair faces of concrete complete all as specified and directed.
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, onforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
M&L for Point wiring with 1100 volts grade PVC insulated FR -LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
One light point controlled by one switch.5/6 Amp
One Exhaust fan/Fan point controlled by one switch 5/6 Amp.
One socket outlet 6 amp controlled by one switch on the same board with other switches.
One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring with 1100 volts grade PVC insulated FR LSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F MCB distribution board SPN, 240 volts, 8 ways,double door, powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
Single pole 6 to 32 amp.
Single pole and neutral (SPN) 40 amp.
TPN 40 Amp to 100 Amp
S&F LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete.
M&L earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x6.0mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below ground level connected to and including galvanized iron wire 4.0mm not exceeding 7.5meters for each earth without protection pipe, including test point by means of bolts, nuts, check nuts, and washers made out of GI all as shown on plate No 3 of SSR Part I to the extent applicable to this item including necessary making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 6 mm dia bar and testing on completion to achieve value complete all as specified and directed.
S&F hum free electronic step fan regulator, 100 watt 2 module complete all as specified abd directed.
S&F LED 35 Watt streetlight made up of prressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP 65/66 protection complete with fixing arrangement and connection as directed
S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified abd directed.
S&F ceiling fan 1200 sweep AC, 230 V 50 Hz, five star rating white/Ivory colour complete all as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 35sqmm, 3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. (Note : Punned thickness shall be considered for the payment purpose.)
Supply and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as directed at site. Make Mehtab or equivalent.
CREATIVE CONSTRUCTION
DEEPAK JAISWAL
GHASI RAM SAHU
M/S Shanti Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .