| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.4 L+₹1.8 L (5.45%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.9 L+₹4.2 L (12.8%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹44.3 L+₹11.7 L (35.7%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L4 | Rejected-Finance Being L4 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Repair/maintenance of LT switchgears and other connected items at old cant and Fort Cantt under GE (East) Prayagraj.
2023_MES_621784_1
8673/E8
Open Tender
Civil Works
Item Rate
270 days
Prayagraj
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Prayagraj
₹80,000
Yes
9 Dec 2023
5 Oct 2023
6 Nov 2023
5 Oct 2023
3 Nov 2023
20 Oct 2023
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables/pipes etc. and getting out in soft/loose soil complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed.
Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. NOTE : Punned thickness shall be measured only.
Supply and laying dry well burnt locally available brick sub class 'B' modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
S&F boring holes for Insertion of 80/50/40 mm dia GI pipe under PCC Road/ Taxi track/ hard standing not more than 12mm deep complete all as specified and directed. Note: - (i) Cost of equipments tools & plants, material required for boring shall be deemed to be included in the rates quoted above. (ii) GI Pipe shall be measured and paid separately.
S & F in repair 40 mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hardstanding including taking down existing pipe complete all as specified and directed. NOTE : Excavation and earth work shall be measured & paid separately.
Ditto All as per Item No. 07 above but 50mm dia GI pipe.
Ditto All as per Item No. 07 above but 80mm dia GI pipe.
Supplying ,laying ,jointing & testing 10 Sqmm, 4 core XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
Ditto all as per item No. 10 but Cable 4 core 16 Sqmm
Ditto.all as per item No. 10 but Cable 3.5 core 25 Sqmm
Ditto.all as per item No. 10 but Cable 3.5 core 35 Sqmm
Ditto all as per item No. 10 but Cable 3.5 core 50 Sqmm
Ditto.all as per item No. 10 but Cable 3.5 core 70 Sqmm
Ditto all as per item No. 10 but Cable 3.5 core 95 Sqmm
Ditto all as per item No. 10 but Cable 3.5 core 185 Sqmm
S&F in repair of service cable 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular as required complete all as specified and directed.
Ditto all as per item No. 18 above but 16 Sqmm cable.
M&L for cutting triming and vending tree branches along HT/LT over head lines after arranging electrical shut down, including taking all precautions while working on lines, contractor using own T&P complete all as specified and directed, (For taking shut down to execute the work min one skilled electrician and four mazdoor for 8 hours/day shall be depolyed on the work).
S&F three pole power contactor , ML-3 type, range of AC-1 rating 45 amp , AC-3 rating 40 Amp ,Aux.Contacts (2NO+2NC), 110V, 220V, 240V and 415V , 50 Hz complete all as directed by Engineering-in-Charge.
S&F three pole power contactor , ML-4 type, range of AC-1 rating 100 amp , AC-3 rating 70 Amp ,Aux.Contacts (2NO+2NC), 110V, 220V, 240V and 415V, 50 Hz complete all as directed by Engineering-in-Charge.
S&F aluminium thimbles cables lugs for cables of size 50 sq.mm including necessary crimping with crimping tool complete all as specified and directed
Ditto all as per item No. 23 above but 70 Sqmm size cable.
Ditto all as per item No. 23 above but 95 Sq.mm to 120Sq.mm size cable.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Indoor/ Outdoor type complete all as specified and directed.
Ditto all as per item No. 26 above but cable size 70 to 150 Sqmm.
Contd/... (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Digital multifunctional panel meter with CTs etc (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (e) INCOMMING:- ACB 4 Pole 630 Amp 415 volt manual drawout type with 50 KA breaking capacity & spreader both side as Incomming control device : 01 Nos. (f) OUTGOING:- (i) MCCB 4 Pole 400 Amp 415 volt with microprocessor release 36 KA breaking capacity & spreader both side as outgoing cotrol device : 01 Nos. (ii) MCCB 4 Pole 250 Amp 415 volt with microprocessor release 36 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. (iii) MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos.
Ditto all as per Item No. 28 but feeder pillarbox with the following changes :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 600 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Digital multifunctional panel meter with CTs etc (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (e) INCOMMING:- MCCB 4 Pole 400 Amp 415 volt with microprocessor release, 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (f) OUTGOING:- (i) MCCB 4 Pole 250 Amp 415 volt with microprocessor release, 36 KA breaking capacity & spreader both side as outgoing cotrol device : 02 Nos.
Contd/... (ii) MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. (iii) MCCB 4 Pole 125 Amp 415 volt with adjustable thermal magnetic release release, 16 KA breaking capacity & spreader both side as outgoin cotrol device : 01 Nos.
Ditto all as per Item No. 28 but feeder pillarbox with the following changes :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 400 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Digital multi functional panel meter with CTs etc (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4) cement sand etc complete. (e) INCOMMING:- MCCB 4 Pole 250 Amp 415 volt with microprocessor release, 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (f) OUTGOING:- (i) MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release, 36 KA breaking capacity & spreader both side as outgoing cotrol device : 02 Nos.
Contd/... (ii) MCCB 4 Pole 125 Amp 415 volt with adjustable thermal magnetic release 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. (iii) MCCB 4 Pole 100 Amp 415 volt with adjustable thermal magnetic release, 16 KA breaking capacity & spreader both side as outgoin cotrol device : 01 Nos.
Ditto all as per Item No. 28 but feeder pillarbox with the following changes :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 600 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Digital multi functional panel meter with CTs etc (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (e) INCOMMING:- MCCB 4 Pole 400 Amp 415 volt with microprocessor release, 50 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (f) OUTGOING:- (i) MCCB 4 Pole 200 Amp 415 volt with adjustable thermal magnetic release, 36 KA breaking capacity & spreader both side as outgoing cotrol device : 02 Nos. (ii) MCCB 3 Pole 63 Amp 415 volt with adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device : 01 Nos.
Ditto all as per Item No. 28 but feeder pillarbox with the following changes :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 400 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Digital multi functional panel meter with CTs etc (d) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (e) INCOMMING:- MCCB 4 Pole 200 Amp 415 volt with microprocessor release, 50 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (f) OUTGOING:- (i) MCCB 4 Pole 160 Amp 415 volt with adjustable thermal magnetic release, 36 KA breaking capacity & spreader both side as outgoing cotrol device : 02 Nos. (ii) MCCB 3 Pole 63 Amp 415 volt with adjustable thermal magnetic release 36 KA breaking capacity & spreader both side as outgoin cotrol device : 01 Nos.
S & F in repair of astronomical type timer switches suitable for operation of street light luminarie with 4 pole Power contactor of 63 A capacity - (01 No) suitable for 3 Phase, 4 wire system incl MCB TPN 63 A capacity - (01 No) , fixed in the Outdoor type box made of polycarbonate of suitable size including its fixing arrangement on pole/panel complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead strip 25mm x 4 mm (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing & taking down of old/ ineffective earthing complete all as specified and directed. (Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode)
Supply, install, test and commissioning of LT out door type kiosk pedastal panel board of sige 60 cm x60 cm x30cm for 3 phase 4 wire 415 volts 50 HZ system, made out of 3.15 mm thick CRCA sheet with powder coated mounted on PCC platform, hinges with locking door arrangement,suitable cable enteries holes at bottom and consisting of the following:- (a) Aluminium bus bar of rating 200 Amps capacity 4 Nos(TPN) mounted on DMC/epoxy supporters with shrouded by PVC insulated and arrangements for incoming / outgoing connections. -01 set
Supply, install, test and commissioning of LT out door type kiosk pedastal panel board of sige 60 cm x 60 cm x 30cm for 3 phase 4 wire 415 volts 50 HZ system, made out of 3.15 mm thick CRCA sheet with powder coated mounted on PCC platform, hinges with locking door arrangement,suitable cable enteries holes at bottom and consisting of the following:- (a) Aluminium bus bar of rating 400 Amps capacity 4 Nos(TPN) mounted on DMC/epoxy supporters with shrouded by PVC insulated and arrangements for incoming / outgoing connections. -01 set
S&F in repair earth continuity conductor or main earthing lead GI strip 32 x 6 mm burried in ground complete all as specified and directed.
S&F in repair OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified and directed.
S&F in repair OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed.
S&F in repair change over switch 100 Amp, 4 pole, on load switch without fuse in open execution type, panel mounted complete all as specified and directed.
S&F in repair change over switch 250 Amp, 4 pole, on load type switch without fuse in open execution type, panel mounted complete all as specified and directed.
S&F in repair ACB ,4 pole, 415 volts, 630 Amps, with thermal magnetic release (Mannual drawout type) including taking out old/ unserviceble ACB complete all as specified and directed.
S&F in repair MCCB ,4 pole, 415 volts, 400 Amps, breaking capacity 36KA, microprocessor release including taking out old/ unserviceble MCCB complete all as specified and directed.
S&F in repair for MCCB ,4 pole, 415 volts, 250 Amps, breaking capacity 36KA, microprocessor release including taking out old/ unserviceble MCCB complete all as specified and directed.
S&F in repair MCCB ,4 pole, 415 volts,160 Amps, breaking capacity 36KA, adjustable thermal magnetic release including taking out old/ unserviceble MCCB complete all as specified and directed.
S&F in repair MCCB , 4 - pole, 415 volts, 100 Amps,breaking capacity 25 kA, with thermal magnetic adjustable type including taking down old/ unserviceble MCCB complete all as specified and directed.
M&L for welding of feeder piller box any size hinges, repair to locking system and painting of LT panel with synthetic emamel paint innner and outer surfaces complete all as specified and directed.
M&L for cleaning the area around all the sub station of electrical installation all by cutting/removing unwanted grass and grass bushes complete all as specified and directed. Note : Tools will be provided by Contractor.
NEXT POWER ENTERPRISES
Shivam Constructions
Charan sales and Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .