Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
8 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
GENERAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' crores or 'V' crores whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIIB of PART-V of Tender Document , along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Please refer Clause 3.5 of PART-I of Tender Document.
Technical Eligibility Criteria:- The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the t e n d e r . Definition of Similar Nature of work:- "Wiring/Rewiring in buildings with associated electrical works. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical works. OR Wiring/Rewiring, Lighting arrangement in buildings with associated electrical works." Please refer Clause 3.4 and Clause 3.5 of PART-I of Tender Document. NOTE:- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Special Eligibility Criteria:- Tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be SUMMARILY REJECTED.
29 conditions · 5 needing a document upload
Tenderer Shall submit COVER LETTER (TENDER FORM-1) as per Section 4.2 of PART-I of Tender Document duly filled. The Cover Letter must be submitted by the Tenderer on its letter head. Please refer Section 4.2 COVER LETTER , TENDER FORM-1 of PART-I of Tender Document.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.Tenderer shall submit the documents as mentioned in Clause 3.7 of of PART-I of Tender Document. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF/ LLP etc. if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected . Format of POA is given in TENDER FORM-3 of PART-I of Tender Document. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate. The tenderer shall submit all the relevant documents mandatorily as mentioned in Clause 3.7 of PART-I of Tender Document.
Necessary information about Employment/Partnership etc. of Retired Railway Employee as per details mentioned in Clause 3.12 of PART-I of Tender Document should be given by tenderer . If no Retired Railway Employee is employed by tenderer then the tenderer shall submit an Undertaking as in Annexure-XXVI of PART-V of Tender Document that no railway employee is employed. Note:- If information as required as per above clause has not been furnished, contract is liable to be dealt in accordance with provision of clause 62 of PART-II of GCC-2022.
Tenderer should submit documents related to registration Details, PAN, GSTIN, Registered Address, Bank Details etc.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall submit along with the tender document, documents in support of his/their claim to fulfill the eligibility criteria as mentioned in the tender document. Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self attestation shall include signature, stamp and date (on each page). Only those documents which are declared explicitly by the tenderer as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating his/their tender.
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 5 (five) years.
The GST Act 2017 will be applicable as per extant policy as notified by Central/State Govt. and as amended from time to time. All the bidders/tenderers should ensure that they are GST compliant and their quoted rates are inclusive of taxes and GST @ 18%.
No Post Tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderers shall be treated as NULL & VOID. (Authority HQ Letter No. 74-W/O/Pt.XXV/WA/Loose dated 07.04.15).
The contract will be governed by Indian Railways Standard General Conditions of Contract updated with correction slips issued up to date of inviting tender or as otherwise specified in the tender documents.
Conditional offer and Alternative proposal by Tenderer: Tenderers shall submit offers that fully comply with the requirements of the Tender documents including the conditions of contract, design and specification requirements if any. Conditional offer or alternative offers will not be considered in tender evaluation and will be summarily rejected. The Tenderer shall have no claims in this regard whatsoever. "Any unconditional rebate offered by the tenderer should be mentioned on of 'Schedule of Quantities' specifically. To attract the rebate mentioned each page of schedule may refer the note for the conditional rebate mentioned in the end. Any rebate mentioned at any other place in tender document shall not be considered. The unconditional rebate mentioned in "Scheduled of Quantities" shall be considered while evaluation of bid." mentioned in the end. Any rebate mentioned at any other place in tender document shall not be considered. The unconditional rebate mentioned in "Scheduled of Quantities" shall be considered while evaluation of bid."
Electrical work for provision of Common user traffic facility at Pathri in connection with CONCOR GCT.
07_SrDEE_G_MB_2026
07_SrDEE_G_MB_2026
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹2.0 L
8 Apr 2026
17 Mar 2026
25 Mar 2026
59 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,01,21,737.66 | ||
| — | — | — | 1,82,440 | ||
| "Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. " | — | 4000.00 | — | — | |
| — | — | — | 47,500 | ||
| "Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc.as per technical specifications.PVC conduit pipe conforming to IS:9597 Part-III.1987 (Latest version)Size:25mm dia (Heavy) for roof. Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. " | — | 500.00 | — | — | |
| — | — | — | 3,25,400 | ||
| Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable conforming to IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/Main as required as per technical specification including connections, testing and commissioning of following sizes: | — | Breakup | for details. | — | |
| — | — | — | 15,563 | ||
| Supply, fixing, testing commissioning of MS switch boxes of the following size made out of 16 SWG MS sheet duly painted / coated with red oxide primer with egg white hylem sheet 3 mm. thick as per tech. specification, ISS / IE Rules and site requirement. Hylem sheet shall be larger than MS Boxes of following sizes:- ( NOTE :- The MS Boxes shall be with earthing bolts and hylem sheet shall be fixed with 04 Nos. brass machine screws and washers etc.) | — | Breakup | for details. | — | |
| — | — | — | 15,508.8 | ||
| Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per IS:4794(Part-2)-1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per technical specifications. | — | Breakup | for details. | — | |
| — | — | — | 8,586.9 | ||
| Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement. | — | 470.00 | — | — | |
| — | — | — | 95,036.4 | ||
| Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest. | — | 180.00 | — | — | |
| — | — | — | 2,71,524 | ||
| Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ) | — | 100.00 | — | — | |
| — | — | — | 77,208.5 | ||
| Supply, erection, fixing, testing & commissioning of 380 mm sweep,1400 rpm(approx) propeller type exhaust fan complete as per IS,IE rule & site requirement.. | — | 25.00 | — | — | |
| — | — | — | 1,29,623 | ||
| Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement. | — | 10.00 | — | — | |
| — | — | — | 65,242.35 | ||
| Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification. | — | 15.00 | — | — | |
| — | — | — | 1,53,083 | ||
| Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule. | — | 50.00 | — | — | |
| — | — | — | 77,768.2 | ||
| Supply,installation,testing and commissioning of Maintenance free Earthing. | — | 4.00 | — | — | |
| — | — | — | 48,082.56 | ||
| Design, Fabrication, Supply, Fixing and commissioning of double door IP 65 Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides with MS Sheet 20 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement. | — | 12.00 | — | — | |
| — | — | — | 3,53,193.6 | ||
| Supply, installation, testing & commissioning of complete 60 watt LED Street light fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest. | — | 80.00 | — | — | |
| — | — | — | 1,84,905.3 | ||
| Supply and fixing of 5 meter long Hot dip galvanized octagonal pole with foundation, base plate, fixing of 01/02 nos. arm 1000 mm. for the fittings including smart pack junction box with 06 Amps. MCB DP (10 KA) and terminals as per technical specification & complete in all respect/as per site requirement. | — | 15.00 | — | — | |
| — | — | — | 32,63,050 | ||
| Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway. | — | Breakup | for details. | — | |
| — | — | — | 70,430 | ||
| Supply,laying,installation,testing and commissioning of HDPE Pipe of 50 mm Dia. (Supply of HDPE pipe shall be as per IS:4984-1995 (latest version) for passing of cable from pole to pole as per site requirement,(Laying of HDPE pipe shall be in conformity to IS 1255/1983 (Latest Version).Excavation work & cable laying shall be covered under Cable laying items scope. | — | 1000.00 | — | — | |
| — | — | — | 6,32,820.75 | ||
| Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep as per relevant IS suitable for laying HDPE Pipe of 140 mm inner dia and 160 mm outer dia. & shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-1995 (latest version) included). | — | 425.00 | — | — | |
| — | — | — | 10,61,502.96 | ||
| """Supply, installation, testing & commissioning of 16 Mtrs high mast system with its accessories comprising of following items: i) Mast shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 part 3. It shall also include accessories for high mast including head frame, steel wire rope 6mm dia 7/19 construction) double drum winch, Galvanized lantern carriage arrangement suitable for 16 luminaries symmetrically and its control gear boxes and its lighting finial. The mast shall have an integral power tool installed inside the base compartment for its operation,Erection and commissioning of high mast with the help of suitable equipment. ii) Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates including design and casting of suitable shallow foundation with M-15 concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sq. Mtrs. at 2 mtrs. depth. iii) Twin dome aviation obstruction light with 2 nos. LED lamps. iv) Control panel housing suitable control circuit for the operation of the mast. v) 08 no. 120 watt LED Flood light fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121- Elect/PS/2018(Rev-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest. Note:-Warranty/Guaranty shall be claimed from the tenderer and not from OEM for light luminaries. The tenderer should replace the material at his own cost by liasioning with OEM. Security will be released after completion of Guaranty period of five years. """ | — | 3.00 | — | — | |
| — | — | — | 1,58,568.21 | ||
| Supply,installation,testing & commissioning of Storage water cooler 150 litres,ISI marked with IS 1475(latest),Non-CFC refrigerant. | — | 3.00 | — | — | |
| — | — | — | 3,84,322.5 | ||
| Supply, erection & fixing of Safety items complete with all accessories (a) Fire Extinguisher dry chemical powder type ISI marked suitable for electric fire 10 Kgs capacity 2 Nos.(b) Rubber Mat ISI marked non skid type suitable for 11 KV AC supply of size 3600x1000x25 mm. 2 Nos. (c) GI Fire buckets 24 gauge fitted on steel stand as per approved dg.10 Ltrs.capacity with clear dry ordinary sand .6 Nos.(d) First Aid Box complete with Medicines of approved make 1 No.(e) Electric Shock Treatment Chart ( Larger size ) with Aluminium frame & glasson front or laminated as approved 8 Nos.(f ) 11 KV / 415Volt Danger Plates confirming to relevant IS . 8 Nos.(g) Schematic diagram of HT / LT installation on white Hylem sheet with Aluminium frame approximate size 1200x600 mm 1 No.(h) Data of Transformer on white Hylem sheet with Aluminium frame as per approved . Approximate size 900x600mm 2 Nos. | — | 30.00 | — | — | |
| — | — | — | 9,00,531.9 | ||
| Supply,Installation,Testing & Commissioning of RCCB 2P 25A 30mA with metal enclosure. RCCB and metal enclosure should be of same make of reputed manufacturer and as per specification. | — | 370.00 | — | — | |
| — | — | — | 35,835.1 | ||
| Supply,Installation,Testing & Commissioning of 63 Amp. 4P-RCCB 100mA, 50Hz in TPN DB. As per specification. | — | 10.00 | — | — | |
| — | — | — | 4,76,379.36 | ||
| Design & manufacture LT switch board as per IS 8623(Latest version), Supply, Installation, fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system. The LT Switch Board shall be powder coated. The incoming feeder shall be provided with three phase KW meter ( Range 0 to 100 KW). The switch board shall be complete with inter connections, instrument connections with copper conductor cable, 400 Amps. Copper bus bar & front operated switchgears, Digital Voltmeter(0 to 500 Volts), Digital Ampere meter (0- 200 Amps) with Selector switch I/C with Indication lights ( lamp set.) earthing studs etc. comprising of following i.e. I/C -MCCB 400 Amps(36 KA) 4 Pole-1 No. (DN 3 type), O/G- 125 Amps MCCB(36 KA) 4 Pole-05 Nos. (DN 2 type) with 200 Amp COS , complete in all respect. | — | 3.00 | — | — | |
| — | — | — | 2,58,579.4 | ||
| Manufacture, supply, fixing and commissioning of fully automatic programmable control panel (as per CEE/NR spec. no. CEE/70Elect/P/90/Rev-4/2010 or latest version (Attached as Annexure-2) for 3 phase 440 V 50/40/30/25/20 HP pump set (Submersible, vertical shaft etc.). Connecting of voltmeter, Ammeter, contactor, overload relay, CT/AC step down transformer 220V/12 volts . Auxiliary relay, changeover, AC timer, motor start/stop contact, push button selector switch, indication light, auto manual, selector switch, Aluminum bus bar, MCCB FP, 100A 35KA,Time delay relay, Programmable timer with 48 hrs. memory back up, Single Phase Preventor, terminal block earthing bolt/connection as per technical specification attached & as per site requirement of following size:- (i) 35 HP | — | 5.00 | — | — | |
| — | — | — | 3,51,320.2 | ||
| "Supply, erection, testing & commissioning of Automatic Colour Light Signalling Control and distribution panel 63 Amps. Capacity 10 KVA AT as per RDSO specification no. TI/SPC/PSI/CLS/0025 (Attached) with latest amendments and material will be supplied from core/ RDSO approved source." | — | 5.00 | — | — | |
| — | — | — | 2,16,479.67 | ||
| Supply & fixing of 50 KVAR APFC Panel Board madeup of1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL7032/7035 with locking arrangements,Dust & Vermin proof,Aluminum Busbar with color coded sleaves Indicating Lamps with control fuses,APFC relay 6 stage.(WithoutReactor) | — | 3.00 | — | — | |
| — | — | — | 2,61,252 | ||
| "Supply of Change over Switch Capacity 200 Amp off Load side handle operated in enclosure 04 pole 415 volt 50 HZ AC Supply conforming to IS: 13947 or latest." | — | 12.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LEDRev.3spec._compressed.pdf
ATTACHMENT
CEELEDSPecMerged.pdf
ATTACHMENT
CEELEDSPecMerged.pdf
ATTACHMENT
ACSGCCmerged.pdf
ATTACHMENT
JPODigging.pdf
ATTACHMENT
I.R.GCC_April-2022.pdf
ATTACHMENT
Annexure-U1.pdf
ATTACHMENT
CLSpanelRDSOSpec_compressed.pdf CLS Panel Specification
ATTACHMENT
Annexure 2
ATTACHMENT
Tenderdocument-07-2026.pdf
ATTACHMENT
letterofcredit.pdf
ATTACHMENT
CLSpanelRDSOSpec_compressed.pdf
ATTACHMENT
CEESpec.no.70-Elect-P-Rev-4-2010.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .