Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.7 L+₹1.2 L (5.90%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹22.3 L+₹1.8 L (8.96%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹22.8 L+₹2.3 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹23.5 L+₹3.0 L (14.7%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
2 Aug 2023, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
IMPROVEMENT OF ROOF TREATMENT, LINTERNS, INTERNAL WATER SUPPLY ARRANGEMENT AND ALLIED WORKS SERVICES UNDER GE (AF) BAMRAULI
2023_MES_608694_1
8831/E8
Open Tender
Civil Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹76,400
Yes
4 Sept 2023
12 Jul 2023
4 Aug 2023
12 Jul 2023
2 Aug 2023
27 Jul 2023
Amount
Demolition, Cement concrete (reinforced) of roof and floor,beams ,staircase,landing,chajjas,Cantilever and similar suspended work in any position complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc
Demolition, Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including all existing treatment such as tar felt, mud phuska etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles, single layer on roof complete all as specified and directed
Demolition of Brickwork built in cement mortar including all quioins, arches, pillars etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of corrugated or plain steel sheetingd ,etc) any gauge sheets in roof covering All as specified by engr-in -chagre
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Dismantling water tanks and removing to store
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position exc 250 ltr n.exc 500 ltr cap etc complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing
(a) 15mm Dia
(b) 20mm Dia
(c) 25 mm Dia
Supply, laying and testing certain bore galvanised steel water tubing medium grade, with all fitting fixed to walls, laid in floors/ceiling and all as specified.
(a) 15mm Dia
(b) 20mm Dia
(c) 25 mm Dia
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in chajja, beam and lintels etc complete all as specified and directed.
Use and waste of flat Form work to sides and sofits of floor or roof beams, beam hunchings, suspended slab, chajjas, lintels, cantilevers, shelves including supports over hankes, etc of plinth/roof beam and similar works vertical or better for fair finished surfaces of concrete etc.
S & F TMT bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with & including MS wire (annealed) not less than 0.9mm dia or securing with clips.
S&F Mild steel TMT 6 to 8 mm cut to length bend to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia conformig to Fe 500.
M & L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6M mean radius, built in cement mortar 1:4 (half brick wall)
M & L for Rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even
M & L for Rendering 10mm thick in cement plaster 1:3 on ceilings fair faces of brick work or concrete surfaces finshed even
M&L for dubbing out average 15mm thick cement mortar 1:4 on irregular face complete all as specified.
M&L for preparation on newly plastered surfaces and applying two coats of white wash on ceiling complete all as specified
M&L for preparation on newly plastered surfaces and applying two coats of cement based paint on walls complete all as specified
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge, fixed with self tapping screws as specified
S&F Roof trusses,purlin,rafter,rails and fastenings and heavy bracket framing,railand fastening and heavy brackets framing(beam ,tee,angle channels or flat section including pieces ,cleats etc etc
S&F of 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
S&F of 110mm PVC (SWR) bends in any radius
M&L for preparation of new steel surface and applying two coats of synthetic enamel paint over red oxide primer all as specified and directed
M&L for providing, cement concrete type B-1 1:2:4 (using 20mm agg) in roof kerbs or mud stops, rounded or chamfered on edges.
M&L for providing cement concrete type B-2, 1:2:4 using agg as in roof padding etc all as specified and directed
M&L for treatment of roof with reinforced elastomeric liquid waterproofing membrane of 100 micron thickness in four layer having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal emittance tested as per ASTM C 1549 and ASTM C1371, respectively), The coating should have water absorption less than 1% as per IS:101 (P-7/Sec-1) 1989, with the ability to resist heat up to 120 degree C as per IS : 101 (P-7/Sec-3) 1990 having VOC less than 1g / ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponded water up to 3.5 bars of pressure for 7 days. It should also be resistant to Ammonia solution , Sodium nitrate, Sodium hydroxide, along with water and soap solution as per IS:101 (P-7/Sec-2)1990. The waterproofing membrane will be laminated with 25-40 micron thick transparent, Nano modified composit crosslinking polymeric coating with a minimum of 40% solid content as per IS :101 (P-8/Sec6)1993 and also should pass impact test as per IS:101(P-5/Sec3) 1988 alongwith having dust and water repellent & anti-graffiti property passing Scratch hardness test of 500g as per IS:101(P-5/Sec-2) 1988. It should also pass cross cut Adhesion test as per IS:101(P-5/Sec-2) 1988. The Polymeric coating should have a self cleaning and easy to clean property withh excellent weather stability and DPR (Dirt pick up ratio). Before laying surface preparation includes pressure wash cleaning to remove all dust, fungus etc with pressure washer after repairing the existing roof having compressive strength as per IS-4031 part 6-1988 & permeability of water as per IS 2645-2003. The work will be done under the supervision of the Engr-in-Charge by Graco airless machine & OEM should be an IGBC (Indian Green Building Council) member & GRIHA Council Certified. The coating thickness and the methodology of application shall strictly be carried out by the authorised vendor/ manufacturer's with all specificatios and as approved by the Engr-in-Charge. The manufacturer shall give a guarantee for the performance & durability for 10 years.
M&L for high performance acrylic polymer modified cementitious waterproofing coating with elastic adheshive to develop excellent bond with shut glass of doors/windows including cleaning of existing surface and treatment will be done by authorised applicater manufacturer. The manufacturer shall give a grarantee for the performance & durability for 10 years.
S&F 500 ltrs Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20 mm pvc float valve with high density pvc ball and rod.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
M/S VIJAY SINGH
M/S SATISH KUMAR
M/S Aquarius Construction
Bharat Trading Company
M/S Amar Enterprises
chauhan construction
M/S SWASTIK BUILDERS
HIMANSHU TRADERS
HARSH ASSOCIETES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .