| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹36.0 L+₹51,575 (1.46%)Rejected-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹39.5 L+₹4.1 L (11.6%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.0 L+₹5.6 L (15.8%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹43.3 L+₹7.9 L (22.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
21 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of certain sanctioned works of E/M nauture under GE (N) Ahmednagar
2020_MES_406855_1
8485 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹36,000
Yes
2 Feb 2021
26 Dec 2020
23 Jan 2021
26 Dec 2020
21 Jan 2021
9 Jan 2021
60 days
Amount
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long etc complete all as specified and directed by Engineer-in-Charge
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw etc complete all as specified and directed by Engineer-in-Charge
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground etc complete all as specified and directed by Engineer-in-Charge
M & L of Copper strip 32 x6mm buried in ground etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of LED flood light 120 Watt, with high luminious efficiency , protected to IP-66 with front toughened glass and connecting with 4 sqmm twin core aluminium cable approx 2.00m Length etc complete all as specified and directed by Engineer-in-Charge Make : Crompton Cat No LFLN-120-CDL/60 or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in replacement of GI Pipe Bracket for street light of Light Grade and dia 40 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement of clamps off size required as per site including nut, bolt and washers etc complete all as specified and directed by Engineer-in-Charge
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire, one twin core cable flat or circular of size 10 sqmm etc complete all as specified and directed by Engineer-in-Charge
S&F jumpers in replacement made out of 6/1 x 2.59 mm weasel ACSR in and including PVC alkaline pipe and nuts, bolts etc complete all as specified and directed by Engineer-in-Charge
S&F jumpers in replacement made out of 6/1 x 4.72mm DOG ACSR in and including PVC alkaline pipe and nuts, bolts etc complete all as specified and directed by Engineer-in-Charge
M & L for replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps of size 25x4mm, bolts and nuts of approved size, for HT, 25x20cm size etc complete all as specified and directed by Engineer-in-Charge
S&F in replcement of vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one etc complete all as specified and directed by Engineer-in-Charge
S&F in replcement of vertical type air break switch, gang operated, Single pole, out door, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 800 Amps current rating complete including dismantling existing one etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 65 KA and rupturing capacity 5 KVA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one etc complete all as specified and directed by Engineer-in-Charged.
M&L for earthing of poles/system with galvanised earth plate 60x60 cm x 6.30 mm thick electrode of size and 32 x 6mm GI strip buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to copper strip dia by means of nuts, bolts and washers and encased in and including 15 dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion etc complete all as specified and directed by Engineer-in-Charge (Note: Any length of GI strip and 15 mm dia GI medium grade pipe shall be provided as per actual requirement at site).
All as per item No 15 above, but with copper plate 60x60cm x 3.15mm thick electrode and 20x3mm copper strip as earthing lead encased in 25 mm bore light grade GI pipe
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc complete all as specified and directed by Engineer-in-Charge
All as per item No 17 above, but aggregate of size 20mm.
M&L for overhauling existing 33 KV / 800A GOD set, horizontal operation by replacing all stationary and moving contacts for all the three phases, rutsed nuts, bolts etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement battery bank 30Volt output by using maintenance free batteries, industrial type, duly charged and tested for 30 volts constant output including M&L requried for modification in existing charging set for auto tripping arrangement to avoid over charging and to maintain 30 volt output continiously for tripping mechanism etc complete all as specified and directed by Engineer-in-Charge
S&F dropout (DO) fuse, explosion for outdoor, single pole mounted on and including 33000V insulator - 02 Nos and MS Channel with nuts, bolts and washer of capacity 100Amp etc complete all as specified and directed by Engineer-in-Charge
S&F lightning arrestor, station class, metal oxide 33 KV class III IEC long duration, current impulse rating with pressure relief high suitable for 33 KV including reconnecting in 33 KV distribution circuit and testing etc complete all as specified and directed by Engineer-in-Charge
S&F 33 KV bus bar made out of 40mm dia 3mm thick aluminium tube including painting with insulated paint of RYB for colour coading etc complete all as specified and directed by Engineer-in-Charge
M&L for painting to 33 KV substation outer fencing and 11 KV substation fencing of structure complete including channel, beams, angle bracket supports, clamps by applying two coats of aluminium paint after scrapping out existing paint including square wire mesh etc complete all as specified and directed by Engineer-in-Charge
M & L for painting of HT steel tubular pole 11 m long by applying two coats of aluminium paint over a coat of red oxide primer including writing of pole Nos etc complete all as specified and directed by Engineer-in-Charge
S& F in replacement sign boards for MES installations of size 1200x 900mm made out of angle iron 40x40x 6mm as framing covered both side with 2 mm thick aluminium sheet rivetting on frame covered with retro reflective sheet & 100mm high letters as diredcted. Th sign board to be fixed on 2 No. 40x40x6mm angle iron legs embedded in PCC(1:4:8) type D2 using 40mm graded stone aggregate including necesary excavation complete at the installation etc complete all as specified and directed by Engineer-in-Charge
Supply,install and commissioning AC Three phase LT/CT multifunction DLMS compliance Energy meter of accuracy class 0.5, 3x240V, 50 Hz with optical and RS232 Port, backlite LCD Display Measures & displays Trivector Energy load survey TOD Tamper detection and logging Power ON / OFF events, instanteneous parameters of Rating 5A with display in absence of power etc complete all as specified and directed by Engineer-in-Charge
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of following size:-
(a) 16 sqmm 4 core.
Supply and fix energy saving ceiling fan 1200 mm sweep size, confiming IS : 374 : 2019 (Bldg) standard 240 volts single phase including provisioning of cord flexible copper 3 core of xiae 23/0.0076 of required length not exceeding 1.5 meter from ceiling rose or connector to ceiling fan for giving electric connection etc complete all as specified and directed by Engineer-in charge .
Supply, installing, commissioning and testing 310 Ltr capacity, refrigerator, double door BEE 5 star rated all including etc complete all as specified and directed by Engineer-in-Charge
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC Casing and capping ISI Marked with necessary accessories with and provision of pressed steel terminal box powder coated of suitable size with 3 mm thick plastic laminated sheet by using CP machine screw for housing of switch/socket/regulators etc including 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following :-
(a) One light point controlled by one, one way switch single pole
(b) One fan point controlled by one, one way switch single pole
(c) One 3 pin 5 Amps socket out let on independent board.
(d) One 3 pin 5 Amps socket out let on same board.
All as per Item No 32 (here-in-before) but 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board
S&F Switch Piano Flush type 230/250 Volt, 5 Amps single pole one way, etc complete all as specified and directed by Engineer-in-Charge
S&F stepped type electronic fan Regulator flush type on the existing phenolic laminated etc, as reqd single pole 240 volts grade 100 watts heavy duty ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination 5 in 1, 5 Amps/15Amps, flush type ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F ceiling rose surface bakelite 65mm x 50mm three etc complete all as specified and directed by Engineer-in-Charge
Tube light fitting & Supply & fix LED tube light aling with fixture, 20W etc complete all as specified and directed by Engineer-in-Charge
Supply, laying, testing & commissioning of HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 120 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size etc complete all as specified and directed by Engineer-in-Charge.
M & L cable jointing kit end termination for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm 3 core etc complete all as specified and directed by Engineer-in-Charge
M& L Boring of holes under road, pavement, hard sanding by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5 m wide and not exc. 1.5 m in depth for laying of under ground cable, pole foundation and stays etc and getting out in hard / dense soil etc complete all as specified and directed by Engineer-in-Charge
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point etc complete all as specified and directed by Engineer-in-Charge
Supply, laying and replcement of PCC covers , class HV type-1 flat size 300x180x40mm etc complete all as specified and directed by Engineer-in-Charge
Supply, laying and replcement of PCC covers , class LV type-2 flat size 300x180x40mm etc complete all as specified and directed by Engineer-in-Charge
Supply and spread unwashed dry river sand cushioning and covering the under ground cable in trenches etc complete all as specified and directed by Engineer-in-Charge Note : Punning thickness shall be measured)
M & L steel tubular poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 Mtrs Long) etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing of MS clamps of size 25x3 mm with nut, bolt and washers duly painted in two coats of aluminium paint over a coat of red oxide etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing FRLS PVC insulated cables aluminium conductor, standard 4 Sqmm 2 Core.
Supply and fixing sintex box of size 200x175x100mm for street ligt control box including 35x5mm size MS FI clamp with Nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC (1:3:6) type C-2 using 40mm grade stone aggregates as foundation of pole and similar work etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC(1:2:4) type C-2 using 40mm grade stone aggregates for coping and similar work etc complete all as specified and directed by Engineer-in-Charge
Dismantling of unserviceable street light & Supply & Fixing street light fitting (LED) type 60 watt pressure die cast aluminium housing with beat resistant tougened glass & IP66 protection and wired including GI pipe bracket clamp as per site requirement with all accessories etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete including necessary plumbing work with accsories etc complete all as specified and directed by Engineer-in-Charge
Dismanintling of unserviceable street light & Supply & Fixing street light fitting (LED) type 70 watt pressure die cast aluminium housing with beat resistant tougened glass & IP66 protection and wired including GI pipe bracket clamp as per site requirement with all accessories etc complete all as specified and directed by Engineer-in-Charge Make : Crompton Cat No LST-20-CDL-M
Taking down existing tube light fitting & supply & fix LED tube light fitting along with fixture 20 W all accessories and electrical wiring etc complete all as specified and directed by Engineer-in-Charge Make : Crompton Cat No LDL-20 NW
Dismanintling of unserviceable street light & Supply & Fixing street light fitting (LED) type 30 watt pressure die cast aluminium housing with beat resistant tougened glass & IP66 protection and wired including GI pipe bracket clamp as per site requirement with all accessories etc complete all as specified and directed by Engineer-in-Charge Make : Cat NO LSTS-30-CDL-M
An amount of Rs 1,17,400.00.00 shall be deducted from BOQ on account of schedule of credit
Maruti Abhiyantriki
M/s Renuka Enterprises
Arihant Construction
R. T. Saluji
Ms. S.K. ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .