Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.2 LAccepted-AOC | L1 | Accepted-AOC Quoted rates lowest | |
| 2 | L2₹79.6 L+₹38,454 (0.49%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Quoted rates not lowest | |
| 3 | L3₹88.4 L+₹9.1 L (11.5%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Quoted rates not lowest | |
| 4 | Rejected-Technical B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | - | Rejected-Technical NR, being two class below |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
16 Feb 2021, 6:00 pmClosed
COL PRADEEP SHARMA,CWE DELHI CANTT
HQ CWE DELHI CANTT-10
REPAIR REPLACEMENT TO ROOF PLASTERING CEILING ETC INCLUDING INTERNAL ELECTRIFICATION AND MISC WORK IN THE AREA OF AGE BR II UNDER GE NORTH DELHI CANTT 10
2021_MES_412660_1
CWE/D-58/2020-21
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹1.9 L
Yes
4 Mar 2021
14 Jan 2021
17 Feb 2021
14 Jan 2021
16 Feb 2021
4 Feb 2021
Amount
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm complete all as specified and directed.
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) M&L for 15mm thick screed bed in CM 1:4 mixed with water proofing compound as per manufacture instruction on existing surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.40 Kg/Sqm of area complete all as specified. (c) Laying 3mm th APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.6 Kg/Sqm with laps & overlaps as specified & joints sealed by torch application method over a layer of 85/25 bitumen @ 1.20 Kg/Sqm complete all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge
Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing PVC tank of any capacity complete all as specified & directed.
Rotational moulded polyethlene water storage tanks of capacity 1000 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing PVC tank of any capacity complete all as specified & directed.
S & F in repair 15 mm bore dia Gun metal gate valve with iron wheel head screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair 20mm bore dia Gun metal gate valve with iron wheel head screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Taking up or down steel water tubing and connections 20mm bore pipe complete all as specified and directed.
M&L 20mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position ( wall/floor/ceilings etc ) of size 20 mm bore complete all as specified.
Taking up or down steel water tubing and connections 15mm bore pipe complete all as specified and directed.
M&L 15mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position ( wall/floor/ceilings etc ) of size 15 mm bore
M&L plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in levelling /sloping/gola course finished even and fair complete all as specified.
Demolition of cement concrete (unreinforced) in roof etc. n.exc 15 cm thickness complete all as specified.
Demolition of cement concrete( unreinforced ) in ground floors and pavings n.exc 15 cm thicness ( below of above ground level )
M/L PCC 1:4:8, type D2, using 20 mm graded aggregate as in sub floor, Sub base, floor complete all as specified & directed.
M&L for coloured precast cement concrete interlocking tiles 100 mm thick, M-50 grade of any shape and size, conforming to IS-15658-2006 glossy finish as in floor/pavement laid on 75mm thick stone dust cushioning, laid dry to the profile over rammed earth/murrum filling complete all as specified & directed.
M&L for coloured precast cement concrete interlocking tiles 60 mm thick, M-35 grade of any shape and size, conforming to IS-15658-2006 glossy finish as in floor/pavement laid on 75mm thick stone dust cushioning, laid dry to the profile over rammed earth/murrum filling complete all as specified & directed.
M&L for Chequered cement concrete tiles of size 300x300x20mm thick, set and jointed in neat cement slurry in floor and pointed with grey cement and pigment including 20mm thick screed in CM 1:6 for bed layer complete all as specified & directed.
M/L PCC 1:2:4, type B1 using 20mm graded stone agg as in bencing,roof kerb, bends and coping.
M/L PCC 1:2:4, type B1 25 mm thick as a levelling course/padding to maintaing the slop of tiles using 20 mm graded stone aggregate.
Dismantling of Plain or corrugated steel/ fibre sheeting of any guage as in roof covering including ridges/gutters etc of any description straight or curved at height upto 15 mtr complete all as specified and directed.
Hacking out old broken glass (any thickness, size , quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips, nut bolts & fillets at ht upto 15 mtr complete all as specified and directed.
Dismantling of AC sheet / corrugated steel sheet roof corrugated/semi corrugated of any description including ridges/gutters etc at height upto 15 mtr complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for .
Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed.
Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as item above here-in-before but except bricks complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws at height upto 15 mtr complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws at height upto 15 mtr complete all as specified and directed.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugations side lap fixed with coach screw and washer, L-type or J-type hooks bolts in roof, wall etc hight up to 15 mtrs complete all as spd and directed.
M&L 6mm thick Asbestos cement Sheet corrugated/semi corrugated fixed with ''L'type or 'J'type or cranked hook/bolts at height upto 15mtr all as specified and directed
Fixing only 6 mm thick AC sheet corrugated/semi corrugated at height upto 15 mtr fixed with 'L' type or 'J' type or cranked hook bolts complete all as specified and directed.
S&F for MS work in Bands, straps, supports or stays for RWP, ventilating pipes, gutters including bolts, if reqd hooks (stay), clamps, holdfasts, wall ties, nosing angles, hooks for hanging fans and similar small articles conforming to Fe-290 gde E-165 hight up to 15 mtrs
S&F structural steel work for rolled sections as in main and cross beams, hips and jack rafters, purlins, running rails and guides for sliding doors, fixed with angles and angle cleats or other connecting plates gde Fe-410-Wat any height complete all as spd and directed.
S&F in repair for Gypsum ceiling board for ceiling prepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light at as specified and directed.
S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n.exc. 0.5 Sqm in each pane at ht upto 15 mtr complete all as specified and directed.
Taking down cement plaster of any description & thickness from brick/concrete sufaces of wall/ceiling etc including racking out joints, hacking for keys scrubbing down with water etc. complete all as specified and directed.
M&L rendering 15mm thick in cement mortar (1:4)on brickwork/concrete surfaces complete all as specified and directed.
M&L rendering 15mm thick in cement mortar (1:6)on brickwork/concrete surfaces complete all as specified and directed.
M&L preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of newly plastered surface on walls and applying two coat of Oil Bound Distemper over a coat of primer complete all as specified and directed.
M&L for preparation of new steel and iron surfaces any description over 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, fan regulators etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit/casing caping medium grade complete with and including all PVC conduit accessories surface on wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed for One light / bell point controlled by one, one way switch 06 Amps.
All as per Srl item No - 45 here in before but one fan point.
All as per Srl item No - 45 here in before but One socket outlet 5 Amps controlled by one switch on same board
All as per Srl item No - 45 here in beforebut One socket outlet 5 amps controlled by one switch on independent board
All as per Srl item No - 45 here in before but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let 16 Amps on independent board
All as per Srl item No - 45 here in before but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall/Surface on wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell point controlled by one, one way switch 06 Amps.
All as per Srl item No - 51 here in before but one fan point.
All as per Srl item No - 51 here in before but One socket outlet 5 Amps controlled by one switch on same board
All as per Srl item No - 51 here in before but One socket outlet 5 amps controlled by one switch on independent board
All as per Srl item No - 51 here in beforebut wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let 16 Amps on independent board
All as per Srl item No - 51 here in beforebut wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with (inner and outer) frame, blanking plate etc suitable for up to 16 module and accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point controlled by one, one way switch 06 Amps.
All as per Srl item No - 57 here in before but one fan point controlled by one, one way switch 06 Amps.
All as per Srl item No - 57 here in before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per Srl item No - 57 here in before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Srl item No - 57 here in before but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
All as per Srl item No - 57 here in before but wiring with 4 sq mm PVC insulated multi-stranded copper conductor for industrial socket outlet 3 pin 16 / 20 Amps point and one single core 4 sq mm PVC insulated unsheathed copper cable as earth continuity conductor
Supply & fixing switch piano flush type, 06 Amps, single pole, one way, 250 volts complete all as specified & directed.
Supply & fixing bell push, flush type, 06 Amps, 250 volts with switch frame complete all as specified & directed.
Supply & fixing switch piano flush type, 16 Amps, single pole, one way, 250 volts with switch frame complete all as specified & directed.
Supply & fixing socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts with socket frame complete all as specified & directed.
Supply & fixing socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 250 volts with socket frame complete all as specified & directed.
Supply and fixing in repair ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
Supply and fixing ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, socket type, humfree, AC, 230 volts, 100 watts, duly ISI marked with and including white surround complete all as specified & directed.
Supply and fixing ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified & directed.
Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb (Make of Bulb : Wipro/Havells/Philips) complete all as specified & directed.
Supply and fixing LED bulb 9W inverter type upto 4 hrs back up, 6500K and remove the UNSV bulb and all as specified and directed.
Supply and fixing modular switch, 10 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed.
Supply and fixing modular bell push with indicator,10 Amps, single pole, one way, 250 volts, complete all as specified & directed.
Supply and fixing modular switch, with indicator, 20 Amps, single pole, one way, 250 volts, one module complete all as specified & directed.
Supply and fixing modular socket outlet 05 Pin, 10 Amps, 02 module with shutter complete all as specified & directed.
Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 20 Amps, 02 module with shutter complete all as specified & directed.
Supply and fixing Modular fan regulator 2 module, stepped type of 0 to 04 rotary steps, electronic, socket type, humfree, AC, 230 volts, 100 watts, duly ISI marked with and including white surround complete all as specified & directed.
S&F in repair 10/12W LED fitting (2 ft) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete.
Supply and fixing in repair on wall / ceiling LED batten lighting fixture 18 watts LED 6500K (4'), with Polycarbonate housing and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block, including taking down of existing u/s light fitting complete all as specified and directed.
Supply and fixing in repair on wall / ceiling LED batten lighting fixture 20 watts LED 6500K (4'), with Polycarbonate housing and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block, including taking down of existing u/s light fitting complete all as specified and directed.
Supply and fixing in repair on wall / ceiling LED batten lighting fixture 22 watts LED 6500K (4'), with Polycarbonate housing and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block, including taking down of existing u/s light fitting complete all as specified and directed.
Taking down of existing u/s recess light fitting and supply & fixing recess mounting 34/36 Watts in CDL, 2x2 LED flat panel complete with envornmental friendly, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source suitable for ceilings high etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as directed.
Taking down of existing u/s Surface light fitting and supply & fixing mounting 34/36 Watts in CDL, 2x2 LED flat panel complete with envornmental friendly, ultra modern mounting luminaries with high brightness SMD LEDs as light source suitable for ceilings high etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as directed.
Supply and fix LED crystal glass tube 18 Watt light double side connection ultra bright with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders.
Supply and fix LED crystal glass tube 18 Watt light Single side connection ultra bright with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders. Make : Havells Cat part No: CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent to the makes in approved list.
Supply and fix LED crystal glass tube 20 Watt light Single side connection ultra bright with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders. Make : Havells Cat part No: CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent to the makes in approved list.
Supply and fix LED crystal glass tube 20 Watt light double side connection ultra bright with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders. Make : Havells Cat part No: CRYSTAL1213T8DSTL20WLED865SGLASSor equivalent to the makes in approved list.
Supply and fix18 Watt ultra bright LED tubelight with aluminium heat sink and polycarbonate diffuser having high efficiency suited for installation in existing T5 fitting with G5 lamp holders driver outside . Make : Havells Cat part No: TITANIASLEEK1149T5DSTL18WLED865SPC or equivalent to the makes in approved list.
Supply and fix 9 Watt ultra bright LED tubelight with aluminium heat sink and polycarbonate diffuser having high efficiency suited for installation in existing T5 fitting with G5 lamp holders driver outside . Make : Havells Cat part No: TITANIASLEEK549T5DSTL9W LED865SPC or equivalent to the makes in approved list.
Supply and fixing in repair energy saving buiilding security light fitting of 70 watts LED environmental friendly pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 40 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
All as per Srl item No - 91 here in before here-in-before but 45 watts.
All as per Srl item No - 91 here in before but 25/30 watts.
Supply and fixing in repair on wall energy saving, eco friendly LED bulk head fitting 10Watt, IP 65surface mounted with ABS body & polycarbonate diffuser, etc and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete all as directed.
S&F of decorative polycarbonate gate/post top lights made up of high grade unbreakable polycarnbonate material suitable upto 20W LED lamp (B22), mounting and exist pipe with necessary fixing arrangements,fitting size in width 150/200mm, height 182/227mm incl taking dwn unsv complete all as specified and directed.
Removal of UNSV fitting, supply and fixing for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specified (Note: light grade GI pipe and necessary PCC works shall be measured and paid separately under relevant items)
Removal of UNSV fitting, Supply and fixing garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution including taking down old fitting, demoliton of brick/PCC work all as specified and directed. (Make :Crompton LBLSN 10 CDL or equivallant inHavells/Philips) (Note: Necessary PCC works shall be measured and paid separately under relevant items)
S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed.
Taking down of existing u/s Post top light fitting and supply & fixing 40 watt LED post top lantern including suitable size medium grade galvanized iron pipe of size 40/50mm up to length of 1.8 Mtrs and necessry plain cement concrete (1:3:6) type CI (using 20mm graded aggregate) as in copings incl necessary form work complete all as specified & directed by Engr-in-charge. Make: Crompton greaves Cat part No: LPTO-40/CDL or equivalent to the makes in approved list.
Taking down of existing u/s Post top light fitting and supply & fixing new generation post top, energy saving envornment friendly long life aesthetically design with symetrical light distribution, spun alluminium landscape luminaire with high power 15 Watt LEDs as light source suitable size medium grade galvanized iron pipe up to length of 0.5 Mtrs and necessry plain cement concrete (1:3:6) type CI (using 20mm graded aggregate) as in copings incl necessary form work complete all as specified & directed by Engr-in-charge.
Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire of 4 mm dia as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and as directed .
Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two SC, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
All as above here-in before but 2 run of 4 sqmm and 1 run of 2.5 sqmm.
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 12 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed.
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed.
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 04 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed.
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volts of 06 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fixing in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make :- Legrand, Cat No. 4085 87 to 4085 95 or equivalent in Hager, Cat No : NCN106N to NCN132N or Schneider, Cat No : A9N1P06C to A9N1P32C.
Supply and fixing in repair MCB, DP, AC, 240 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair MCB, DP, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing Ventilating fan wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
Supply & fixing in repair MCCB, 250 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete all as specified & directed. Make :- Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No. HDA126Z or Schneider, Cat No.LV516312
Supply & fixing in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. Make :- Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No. HDA126Z or Schneider, Cat No.LV516312
Supply & fixing in repair MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. Make :- Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No. HDA126Z or Schneider, Cat No.LV516312
Supply & fixing in repair MCCB, 63 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. Make :- Legrand, Model : DPX 160, Cat No. 4200 16 or equivalent in Hager, Cat No. HDA126Z or Schneider, Cat No.LV516312
Supply and fixing or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Taking down ceiling fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser, flexible wire, down rod, canopies. (Note : Rubber bush, bearing, capacitor, copper flexible wire, down rods, canopies as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding of stater of the ceiling fan of any sweep with matching gauge and turns of super enamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Supply only capacitor 2.5 Mfd, 240 Volts (Make- Tibcon/Havells/Epcos/Asian)
All as per Srl item No - 122 here in before but 3.15 Mfd
Supply only for ball bearing number of 6201 to 6204 as required for fan complete (Make : SKF/NBC)
Supply only rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan
Rewinding of burnt winding of the Exhaust fan up to 300 mm to 450mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Supply and fixing in repair of desert/Air cooler of body size 25"x25"x32", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 180 watt with metallic blade, ISI marked, 1400 RPM, 230 volt AC, tank capacity not less than 100 ltr, incl plastic submersible pumps, electronis fan regulator with P/switch, desert cooler to be fitted with 6mm thick plywood to cover the gap as required size at existing window and old unsv desert cooler depositing in E/M Store yard complete all as directed (Make : JK Classic/Decool/Supreme/Kapsun)
S&F in replacement fan motor kit incl blade, steel body for desert cooler of flow capacity upto 4000 Cum/Hr complete all as directed (Make :- Khaitan/CG/Bajaj)
M&L fan blade (PVC type) suitable for desert cooler up to 450mm sweep fan complete all as directed (Make as per sample)
S&F in repair plastic submersible pump suitable for desert cooler any size complete all as directed (Make : Khaitan/CG/Bajaj
Supply and fixing 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler.
S&F desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size.
S&F in replacement desert coolers body of required size made out of 18 SWG MS sheet complete including inside panel made out of 22 SWG MS sheet complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed.
S&F in repair PVC flexible pipe of high density for 15 mm bore for desert cooler of any size complete
M&L for servicing of any type and any make of split type AC/Window AC of 2 ton/1.5 ton capacity complete by dismantaling of AC and re-fixing after cleaning and replacement defective parts, dismantling the cover of condensing unit carefully and carry out servicing cleaning of the external surface (both side) throughly with the help of descaling chemical, brush, plain water and dry properly by using air blower for cleaning air dust deposited on epqt and charging of gas in adequate quantity as required re-fixing after repair complete
M&L for charging of refrigerant R-22 / R-410A or any other recommended refrigerant gas in 1.5/2 Ton window/split Air conditioner including detecting leakage and rectify the leakage with proper brazing and testing on full load complete all as directed.
S&F in replacement Motor double shaft 1/5 HP capacity for window type AC 1.5 ton/2 ton capacity complete (Make : As per sample)
S&F in replacement Motor single shaft 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample)
S&F in repair thermostat for split AC/Window AC of capacity 1.5/2 Ton complete (Make : As per sample)
S&F of filter for split AC of 1.5/2 TR cap including taking out the old u/s filter complete
S&F of Reverse valve (heating and cooling type) suitable for split AC of capacity 1.5 TR by taking out of old u/s valve from the outdoor unit of AC and fixing of new valve by breazing/soldering and charging of adequate quantity of gas and testing on completion complete all as directed
All as per Srl item No - 141 here in before but for split AC of 2.0 TR capacity
S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5 TR and charging of adequate quantity of refrigerant gas and testing on completion complete (Make : Bule Star/Carrier/Kirloskar/Emarsion/Teckmesh)
All as per Srl item No - 143 here in before but for 2.0 TR capacity
S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5TR / 2.0 TR complete
Supply and fixing in repair on wall / ceiling LED type flame proof fitting 1x16 watt/20 watt CMRI Certified IP 65 Protection complete all as specified and directed.
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (TPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCB, 63 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volts of 06 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos.
Taking down defective street light fitting any watage from pole/bldg and repair the same including replacement of defective/ faulty LED driver and refexing the same incl connection complete all as directed
imran construction company
V r traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .