Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance | L1 | Accepted-Finance Accept | |
| 2 | L2₹2.9 L+₹3,711 (1.32%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹3.1 L+₹31,227 (11.1%)Rejected-Finance VILLAGE P O SEHALI TEHSIL KOTI DISTT MANDI H P | KOTI | MANDI | HIMACHAL PRADESH | L3 | Rejected-Finance Reject |
| Sl No | Description | Qty | Unit | VIKAS TYAGI L2 | Nitesh Kumar L3 | JEETANDER SHARMA L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge. | 256.07 | Cum. | 330 ₹84,503 | 390 ₹99,867 | 190 ₹48,653 Lowest |
| 2.00 | Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge. | 1.87 | Cum. | 8,000 ₹14,960 Lowest | 8,500 ₹15,895 | 8,000 ₹14,960 Lowest |
| 3.00Providing and laying cement concrete 1:1.5:3(1cement:1.5 approved sand:3approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth: | ||||||
| 3.01 | i) Foundation and plinth (bed) with in all leads and lifts. | 2.29 | Cum. | 8,100 ₹18,549 Lowest | 10,000 ₹22,900 | 9,000 ₹20,610 |
| 3.02 | (ii) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge. | 3.53 | Cum. | 8,500 ₹30,005 Lowest | 11,000 ₹38,830 | 9,000 ₹31,770 |
| 4.00Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in | ||||||
| 4.01 | Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge. | 1.03 | Cum. | 10,000 ₹10,300 | 9,000 ₹9,270 | 900 ₹927 Lowest |
| 5.00Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge. | ||||||
| 5.01 | i) Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness . | 9.17 | Sqm. | 550 ₹5,044 | 350 ₹3,210 Lowest | 600 ₹5,502 |
| 5.02 | ii) Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like. | 47.03 | Sqm. | 465 ₹21,869 | 400 ₹18,812 | 250 ₹11,758 Lowest |
Tender Value
₹3.6 L
EMD Value
₹7,102
Closing Date
30 Jul 2025, 11:00 amClosed
EE Nerwa Division
JSV Division Nerwa
Sh C O RCC S T 1 No and laying testing jointing of GI pipe for distribution network etc
2025_HPIPH_110792_1
No.JSV ND-ten/2025-2541-91
Open Tender
Civil Works
Item Rate
120 days
Nerwa Division
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
EE Nerwa
₹7,102
19 Aug 2025
23 Jul 2025
30 Jul 2025
23 Jul 2025
30 Jul 2025
23 Jul 2025
Amount
Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge.
Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm( Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge.
Providing and laying cement concrete 1:1.5:3(1cement:1.5 approved sand:3approved graded stone agg. 20mm nominal size) & curing complete excluding cost of form work in foundation and plinth:
i) Foundation and plinth (bed) with in all leads and lifts.
(ii) Wall (any thickness but not less than 0.1 m thickness) attached pilasters,buttresses, plinth and string courses etc. from top of foundation level up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge.
Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
i) Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness .
ii) Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like.
iii) Edge of slab
Providing mild steel/ tor steel reinfircement for rainforced concrete work i/c bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge.
Providing and fixing (M.S Sheet & Angle iron) 600X60 mm dia man hole cover with frame cantrolling chamber for wheel valve complete. In all respect i.e locking arrangement etc. (not less than 35 kg each) abd angle iron stair case for up & down (not less than 75 kg)
Providing & fixing GMS tubes of following dia in wall floor, ventilating pipe/over flow pipe etc. including tube fitting and making the wall, floor etc. good. i.e ewlding with one feets 25 mm flat iron both side of req. pipes. (25mm-80mm) dia
Providing & fixing cantrolling arrangement with( 25 to 65) mm dia wheel valve i/c all type of tube fitting compelete.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter. with in all leads and lifts as per the direction of the Engineer in charge.
Laying and jointing in treanches GMS tube the same as per entire satisfication of Engineer - in - Charge.
15 mm dia.
20 mm dia.
25mm dia.
32mm dia.
VIKAS TYAGI (BID ID -539707)
Nitesh Kumar (BID ID -539765)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .