Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹8.9 L | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area. |
| 2 | Rejected-Technical DAKRA RANCHI PIN 829201 | CHATRA | JHARKHAND | 829201 | - | - | Rejected-Technical Technically disqualified. |
| 3 | Rejected-Technical KUJU COLLIERY RAMGARH DIST RAMGARH PIN 825316 JHARKHAND | RAMGARH | RAMGARH | JHARKHAND | 825316 | - | - | Rejected-Technical Technically disqualified. |
| 4 | Rejected-Technical 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | - | - | Rejected-Technical Technically disqualified. |
| Sl No | Description | Qty | Unit | M/S PRAVEEN KUMAR L1 |
|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. | 220 | Point | 1,021 ₹2,24,620 Lowest |
| 2.00 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. | 300 | Metre | 392 ₹1,17,600 Lowest |
| 3.00 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin and 5/6 amps socket outlet and 5/6 Amp piano type switch, connection, etc. as required.(For light plugs to be used in non residential buildings) | 100 | Nos | 310 ₹31,000 Lowest |
| 4.00 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required | 60 | Nos | 433 ₹25,980 Lowest |
| 5.00 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required | 45 | Nos | 341 ₹15,345 Lowest |
| 6.00 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required. | 50 | Nos | 75 ₹3,750 Lowest |
| 7.00 | Supplying and fixing brass batten / angle holder including connection etc as required. | 45 | Nos | 115 ₹5,175 Lowest |
| 8.00 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc as required. 32 Amp TP&N | 30 | Nos | 2,030 ₹60,900 Lowest |
| 9.00 | Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required. | 35 | Nos | 1,090 ₹38,150 Lowest |
| 10.00 | Supplying and fixing TP sheet steel enclosure on surface / recess along with 16/25/32 amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required. | 20 | Nos | 1,495 ₹29,900 Lowest |
Tender Value
₹8.2 L
EMD Value
₹10,300
Closing Date
31 Mar 2025, 5:00 pmClosed
SO EnM NK AREA
GM OFFICE, NK AREA
AMC for repair and maintenance of internal electrical wiring and allied works of different residential quarters in respect of employees working under Purnadih OCP at Karkatta, Bishrampur and Khilawandhaura for a period of two years under Purnadih
2025_CCL_332956_1
GM (NK)/EnM/e-NIT/2024-25/ 248
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Purnadih OCP
As per NIT
2 documents required · 2 mandatory
₹10,300
25 Aug 2025
19 Mar 2025
1 Apr 2025
20 Mar 2025
31 Mar 2025
20 Mar 2025
20 Mar 2025 - 26 Mar 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire.
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin and 5/6 amps socket outlet and 5/6 Amp piano type switch, connection, etc. as required.(For light plugs to be used in non residential buildings)
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing brass batten / angle holder including connection etc as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc as required. 32 Amp TP&N
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface / recess along with 16/25/32 amps 415 volts “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 5/6 amps switch
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 3 Pin 5/6 amp socket outlet.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 4 sq. mm
Earthing with G.I. earth pipe 4.5 Metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal / coke and salt as required.
Providing and fixing 6 SWG dia G.I on surface or in recess for loop earthing as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 6 sq. mm
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .