| # | Company | Amount |
|---|---|---|
| 1 | ₹1.6 Cr 1 FLOOR SHRADDHA COMPLEX GE ROAD RAIPUR CHHATTISGARH PIN 492001 91 98261 46919 | ₹1.6 Cr |
Tender Value
₹87.5 L
EMD Value
₹87,511
Closing Date
17 Jul 2025, 11:00 amClosed
Supply Installation Testing and Commissioning of Solar water heating system and Electric water Heating Geyser units along with associated items complete in all respect at Jawahar Navodaya Vidyalayas Schools located for Jammu Kashmir and Ladhak Under Chandigarh Region
NVSJANDK
NVSJANDK
Open Tender-Domestic
Civil Works - Others
Chandigarh, Chandigarh
₹11,800
₹87,511
16 Jul 2026
3 Jul 2025
17 Jul 2025
17 Jul 2025
21 Jul 2025
ESTIMATED COST: SUMMARY
Sr. No. Description AMOUNT (RS.)
A Estimated Cost
1 Solar Water Heating System & Electric Geysers : 500LPD Each
(i) Jammu & Kashmir 8751114.57
TOTAL ESTIMATED COST (RUPEES) 8751114.57
SAY (Rs. In CR.) 0.875
Inclusive of GST
Digitally signed by AKSHIT
PROJECT: SOLAR WATER HEATING SYSTEM & ELECTRIC WATER HEATERS/GEYSERS
J&K UNDER CHANDIGARH REGION
Sr. No. Description AMOUNT (RS.)
A Estimated Cost
1 Solar Water Heating System 500LPD Each 1068536.00
2 Solar Electric Heater/ Geyser 500LPD Each 7682578.57
TOTAL ESTIMATED COST (RUPEES) 8751114.57
SAY (Rs. In CR.) 0.875
Inclusive of GST
Digitally signed by AKSHIT
NVS (J&K UNDER CHANDIGARH REGION)
SOLAR WATER HEATING AND ELECTRIC WATER HEATER/GEYSER UNITS
Description Unit Qty. Rate Amount (Rs.)
SOLAR WATER HEATING SYSTEM OF CAPACITY: 500 LPD EACH
Supply, Installation, Testing & Commissioning of 500 LPD Flat Plate based thermosyphone circulation Non-Pressurized Solar water heating Systems comprising Flat Plate
1.0 DSR 2025 collectors , internal system piping, insulated hot water storage tank , Electric Back up Heaters, plumbing accessories, electrical items as required. Including DLP of complete
system for 2 years and Guarantee/warranttee of Solar water heating unit for 5 years. Details of each items to be used in one 500 LPD system are mentioned below:
ITEMS FOR 1 SET
14.2 SOLAR WATER HEATER (FLAT PLATE TYPE COLLECTOR) Supply, Installation, Testing & Commissioning of Flat Plate collector (FPC) Solar Water Heating System
comprising of solar flat plate collector ISI Marked made of copper sheet/copper tube, absorber toughened glass cover and aluminum extruded channel confirm to IS: 12933
(Part 1,2,3&5 ). The system shall have temperature gauges, strainer, water meter 2 nos., cold and hot water tank. The system shall have suitable electric backup complete with
control and power wiring etc., as following.
Cover plate: cover plate shall be toughened glass and thickness of 4.0 mm (min) conforming to section -1 of IS: 12933(pt-2)/2003 the solar transmittances of the cover plate
shall be minimum 82 percent at near normal incidence.
Collector box: collector box shall be made of aluminum sections. The type grade, size, and finish of the material used shall be as per section- 2 of IS: 12933 (pt-2)/2003: the
minimum thickness of aluminum shall be as under:
Channel section for sides 1.6 mm
Sheet for bottom 0.7 mm
Support for glass retaining 1.2 mm
Sheet for entire body 1.0 mm
The insulation of collector box shall be minimum 0.96 m2 ⁰C/W for back insulation and minimum 0.48 m square degree c/w for side insulation conform to sec. 4 of IS 12933
(pt – 2) / 2003. (b) Gaskets and grommets: gaskets and grommets shall conform to Sec. 5 of IS 12933 (pt-2)/ 2003.
Absorber Shall Consist of riser, Header and Sheet for absorber. The Diameter of header shall be 25.4 + /-0.5mm and thickness 0.71mm. The Diameter of riser shall be 12.7 + /-
0.5 mm and thickness 0.56mm and made of copper only. The distance between the risers from center to center shall be 120mm. type grade, size , workmanship and finish of
the material used shall be as per section- 3 of IS : 12933 (pt -2 ) /2003 the sheet for absorber shall be of copper sheet 34 gauge/copper tube (at least 10 nos.)
Riser and header assembly designed for working pressure up 245 k pa (2.5 kg/ cm square) shall be tested for leakage at a minimum hydraulic pressure of 490 k pa (5 kg/ cm
square). Sheet for absorber shall be made of copper only. Type Grade, size, workmanship and finis of the material used shall be per Section -3 of IS: 12933 (pt -2) /2003
HDPE/LDPE cold water tank shall be dully elected on MS angle /channel duly painted with dual coats of enamel paint. The overall structure of solar collector plate module
shall be design to with stand wind velocity of 100 kms /hr (minimum) or more as per site.
Hot water tank : The tank capacity shall be minimum 1.25 time the rated capacity of system. Inner tank material shall be stainless steel SS 316, as per IS 1730 GRADE SS304-
2B. Hot water shall be insulated with high density injected PUF insulation: 50 mm, of 50 mm thickness between inner and outer tank ensures maximum heat rotenone ever
Suitable nos. ISI Marked electrical heaters along control panel, MCCB, with all protections, and all safety provisions so as to achieve 60⁰C temperature rise in an hour. The
range of thermostat shall be upto 800C.
PLUMBING ITEMS PER SET
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
mm nominal the Pipes
pipe with clamps
(Min.: at 1.00
site includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per
Nitrile foam insulation of 9 mm thick with 26 gauge aluminium cladding for 20mm dia Hot water Pipe (Min.: 8Mtrs OR as per actual Site requirement)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore (Min.: 2nos. OR as per actual site requirements)
Digitally signed by AKSHIT
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore -Horizental (Min.: 2nos. OR as per actual site requirements)
Auto Air Vent -20mm (Min.: 1nos.OR as per actual site requirements)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (Min.: 1nos.OR as per actual site requirements)
Electrical Wiring for incoming to ACDB :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class
X 6 sq. mm earth wire (Min.: 15mtrs OR as per actual site requirements) set 8 29170.00 233360.00
ELECTRIC WATER HEATING SYSTEM OF CAPACITY : 500 LPD EACH
Supply, Installation, Testing & Commissioning of 500 LPD Electric Water Heating System/ Geyser comprising Electric Heaters , internal system piping, insulated hot water
2.0 NS storage tank, plumbing accessories, electrical items as required. Including DLP of complete system for 2 years and Guarantee/warranttee of Electric water
heating/Geyser unit for 5 years. Details of each items to be used in one 500 LPD system are mentioned below:
ITEMS FOR 1 SET
SITC of 500LPD Electric Heating System/ Geyser having Hot Water Storage Tank made out of MS steel of 2.0 mm thickness and Manufacturer Standard Dish Thickness
with internal epoxy/PU coating OR SS 2 mm thick and outer precoated Aluminium Cladding over 50mm PUF Insulation having density not less than 32Kg/Cu.mtr.
Maintenance free sacrificial/Magnesium Anode, provided with Electrical Heater 2Nos. x 3KW electrodes with thermostat/ Auto Cut , Cold Water inlet, Hot Water outlet.
Storage Tank Stand made out of MS angle iron size shall not be not less than 35mmx35mmx3mm, CC Foundation as per the direction of Engineer incharge.
PLUMBING ITEMS PER SET
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes (Min.: 15Mtrs OR as per actual site requirement)
Nitrile foam insulation of 9 mm thick with 26 gauge aluminium cladding for 20mm dia Hot water Pipe (Min.: 8Mtrs OR as per actual Site requirement)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore (Min.: 2nos. OR as per actual site requirements)
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore -Horizental (Min.: 2nos. OR as per actual site requirements)
Y Strainer -Screwed- 20mm dia -Bronze (Min.: 1nos.OR as per actual site requirements)
Air Release Valave- 20mm (Min.: 1nos.OR as per actual site requirements)
Auto Air Vent -20mm (Min.: 1nos.OR as per actual site requirements)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (Min.: 1nos.OR as per actual site requirements)
Dial Type Temprature Gauge 100mm dia (0-150deg) (Min.: 1nos.OR as per actual site requirements)
Control Panel / ACDB for Electrical Heater including required switchgear like DP MCB incommer & DP MCB outgoing of suitable ratings for each 3KW Heater. Housed in
Poly Carbonate (IP65) Enclosure, Complete with wiring up to heater in PVC Conduit.
Electrical Wiring for incoming to ACDB :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class
PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Min.: 15mtrs OR as per actual site requirements)
Digitally signed by AKSHIT
stage.html
html • 0.05 MB
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT.pdf
Tender Document
SCOPE OF WORK.pdf
Tender Document
SCC.pdf
Tender Document
BOQ.pdf
Tender Document
Tech Sceps.pdf
Tender Document
GCC.pdf
Tender Document
Electric 500LPD Layout.pdf
Tender Document
SWHS 500LPD Layout.pdf
Tender Document
Make List.pdf
Tender Document
corrigendum-3997-Corrigendum02.pdf
pdf • 0.34 MB
corrigendum-3964-Corrigendum01.pdf
pdf • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .