| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.8 L+₹2.2 L (7.98%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹34.4 L+₹6.9 L (24.9%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹35.6 L+₹8.0 L (29.1%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/S ADHIKARI CONSTRUCTION CO. L3 | Vijeta Solutions L4 | J V ENGINEERS / JAI SINGH L1 | PARAS ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Attending complaints from 08:45 Hrs to 16:45 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed. | 6,000 | Each Complaint | 59 ₹3,54,000 | 25 ₹1,50,000 | 29 ₹1,74,000 | 22 ₹1,32,000 Lowest |
| 2.00 | All as per Srl item No. 1.00 here-in-before but attending complaints From 16:45 hrs to 23:45 Hrs. | 500 | Each Complaint | 129 ₹64,500 | 25 ₹12,500 | 29 ₹14,500 | 22 ₹11,000 Lowest |
| 3.00 | All as per Srl item No. 1.00 here-in-before but attending complaints From 23:45 hrs to 08:45 Hrs. | 40 | Each Complaint | 149 ₹5,960 | 25 ₹1,000 | 50 ₹2,000 | 22 ₹880 Lowest |
| 4.00Notes for Srl item Nos.01, 02 & 3 :- 1. The Area for attending complaints of OTM ACCN 35 INF BDE, 16 KUMAON, 18 GRENADIERS, 227 WKSSHOP AND OTHER OTM LOCATIONS and Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. Small pieces of FRLS Copper wire/sunken box and laminated sheet required for attending the complaint shall be measured and paid separately against 'supply only' under respective item of BoQ. | |||||||
| 5.00 | M&L for comprehensive maint of ceiling, exhaust fan of Md accn including proper checking of base connection, lock pin of U clamp fan blade, serviceability of down rod, gun metal bush, shaft, stater, ring, ceiling fan outer body, exhaust fan blade, body and capacitor where ever required complete with greasing/lubrication and cleaning of fan bearing complete all as specified and as directed.
Note :- 1. All material required/spare parts shall be measured and paid separately against 'supply only' under respective item of BoQ.
2. The rated quoted by the contractor deemed to be including taking down of ceilingfan/exhaust fan, transportation to workshop for rewinding or machining work, and refixing the same after repair. | 820 | Each | 99 ₹81,180 | 9 ₹7,380 | 1 ₹820 Lowest | 30 ₹24,600 |
| 6.00 | M&L for rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaningand winding with supper enameled copper wire of superior quality of same gauge, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan complete all as specified and as directed. | 600 | Each | 299 ₹1,79,400 | 225 ₹1,35,000 | 145 ₹87,000 Lowest | 260 ₹1,56,000 |
| 7.00 | All as per Srl item No.6.00 here-in-before, but exhaust fan of 230/300 mm sweep. | 150 | Each | 299 ₹44,850 | 250 ₹37,500 | 145 ₹21,750 Lowest | 210 ₹31,500 |
| 8.00 | All as per Srl item No.6.00 here-in-before, but exhaust fan of 450 mm sweep. | 35 | Each | 499 ₹17,465 | 250 ₹8,750 Lowest | 550 ₹19,250 | 350 ₹12,250 |
| 9.00 | All as per Srl item No.6.00 here-in-before, but wall mount fan of 450 mm sweep. | 35 | Each | 499 ₹17,465 | 250 ₹8,750 Lowest | 550 ₹19,250 | 350 ₹12,250 |
| 10.00 | Supply only in repairs 1200mm sweep BLDC fan controller PCB with short circuit protection power 240V suitable for BLDC ceiling fan of existing make at site complete all as specified and as directed. | 40 | Each | 999 ₹39,960 | 900 ₹36,000 | 355 ₹14,200 Lowest | 450 ₹18,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Oct 2025, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIR/REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTS SUMMER AND WINTER APPLIANCES INCL ATTENDING DAY TO DAY PETTY COMPLAINTS AT OTM ACCN 35 INF BDE, 16 KUMAON, 18 GRENADIERS, 227 WKSHOP AND OTHER OTM LOCATIONS
2025_MES_729620_1
GE/TOKEN-74/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹96,000
Yes
19 Dec 2025
6 Sept 2025
6 Oct 2025
6 Sept 2025
4 Oct 2025
20 Sept 2025
Amount
Attending complaints from 08:45 Hrs to 16:45 Hrs for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
All as per Srl item No. 1.00 here-in-before but attending complaints From 16:45 hrs to 23:45 Hrs.
All as per Srl item No. 1.00 here-in-before but attending complaints From 23:45 hrs to 08:45 Hrs.
Notes for Srl item Nos.01, 02 & 3 :- 1. The Area for attending complaints of OTM ACCN 35 INF BDE, 16 KUMAON, 18 GRENADIERS, 227 WKSSHOP AND OTHER OTM LOCATIONS and Contractor shall provide adequate numbers of tradesmen (electrician) alongwith helper to attend the complaints all the above areas in all working days including holiday and sunday. 2. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the team of electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. 4. A recovery of Rs. 500/- for not attending the complaint upto 04 hours and after 04 hours Rs. 1000/- shall be recovered from the contractor due. 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. Small pieces of FRLS Copper wire/sunken box and laminated sheet required for attending the complaint shall be measured and paid separately against 'supply only' under respective item of BoQ.
M&L for comprehensive maint of ceiling, exhaust fan of Md accn including proper checking of base connection, lock pin of U clamp fan blade, serviceability of down rod, gun metal bush, shaft, stater, ring, ceiling fan outer body, exhaust fan blade, body and capacitor where ever required complete with greasing/lubrication and cleaning of fan bearing complete all as specified and as directed. Note :- 1. All material required/spare parts shall be measured and paid separately against 'supply only' under respective item of BoQ. 2. The rated quoted by the contractor deemed to be including taking down of ceilingfan/exhaust fan, transportation to workshop for rewinding or machining work, and refixing the same after repair.
M&L for rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaningand winding with supper enameled copper wire of superior quality of same gauge, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan complete all as specified and as directed.
All as per Srl item No.6.00 here-in-before, but exhaust fan of 230/300 mm sweep.
All as per Srl item No.6.00 here-in-before, but exhaust fan of 450 mm sweep.
All as per Srl item No.6.00 here-in-before, but wall mount fan of 450 mm sweep.
Supply only in repairs 1200mm sweep BLDC fan controller PCB with short circuit protection power 240V suitable for BLDC ceiling fan of existing make at site complete all as specified and as directed.
Supply only frame of exhaust fans of 230/300 mm sweep heavy duty duly as per existing complete all as specified and as directed.
Supply only frame of exhaust fans of 450 mm sweep heavy duty duly as per existing complete all as specified and as directed.
Supply only Canopy (set of 2) for Ceiling fans of 1200/1400mm swipe heavy duty complete all as specified and as directed.
Supply only ball bearing for ceiling fan of suitable size & model as per existing complete all as specified and as directed.
Supply only 'U' clamp with rubber real for hanging ceiling fans of 1200/1400 mm sweep as per sample complete all as specified and as directed.
S&F in repair exhaust fan louvers as per existing upto 450mm sweep complete with all fiting and fixture all as specified and directed.
Supply only down rod of 1.5 feet height fabricated out of MS pipe 12mm dia heavy duty, duly painted with one coat of white synthetic enamel paint complete all as specified and as directed.
Supply only blade (set of 3 blades) of Ceiling fans 1200/1400mm sweep heavy duty as per existing complete all as specified and as directed.
Supply only blade (set of 3/4 blades) of exhaust fans of 300 mm sweep heavy duty complete all as specified and as directed.
Supply only blade (set of 3/4 blades) of wall mounted fresh air fans of 450 mm sweep heavy duty complete all as specified and as directed.
Supply only ceiling fan capacitor of 2.5 mfd complete all as specified and as directed.
Supply only ceiling fan capacitor of 3.5 mfd complete all as specified and as directed.
S& F in repair fan regulator electronic, stepped type/switch type, suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed.
M&L for descalling of geyser 25/35/50 ltrs capacity of any make, opening and inspection for descalling by chemical, treatment of internal tank, themrostate pipe, base plate assembly for replacement of defective parts, gaskets etc to make fully functional, testing and refixing in position including making electrical and water connection complete all as specified and as directed. Note :- 1. All material required/spare parts shall be measured and paid separately against 'supply only' under respective item of BoQ.
Supply only heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
Supply only in of storage tank made out of Stainsteel tank of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressure complete all as specified and directed by Engineer-in-Charge.
Supply only MS base plate assembly 20 SWG heavy duty suitable for 25 to 50 litre capacity geyser with complete inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site As per sample complete all as specified and directed by Engineer-in-Charge.
Supply only safety plug and nut for high pressure release as per existing complete all as specified and as directed.
Supply only Rubber gasket for Water heater storage of any capacity fixed and suitable as per the existing, complete all as specified and as directed.
S&F plug top, 15 Amps, 230 Volts, 50 Hz complete all as specified and as directed.
S&F in repair of PRCD 16 AMP, 30 mA plug Top , complete all as specified and as directed.
Supply only MS top & bottom cover for geysers of 25 ltrs capacity any make as per sample duly painted with two coats of synthetic enamel spray paint (first quality) as per existing complete all as specified and as directed.
Supply only MS outer cover for geyser made out of MS sheet suitable for upto 25 ltrs capacity geyser vertical/horizontal type complete all as specified and as directed.
Supply only MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
Supply only indicating lamp round/flat type (Red & Green) 230 volts suitable for Geyser as per sample complete all as specified and as directed.
Supply only safety valve ISI marked as per existing complete all as specified and as directed.
Supply only thermostat 9/11" (ISI Marked) for 25/35/50 Litres capacity geyser as per sample complete all as specified and as directed.
Supply only PVC connection 15 mm x 600 mm for Hot & Cold water with brass nuts and washers at both ends as per existing complete all as specified and as directed.
S&F in repair 30 watt street light (Building security light) LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90C), complete all as specified and as directed.
S&F in repair of GI pipe's bracket suitable for fixing of bldg security LED light fitting of 45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed. Note :- GI pipe should be 25 mm bore with medium grade and the same to be moulded in 45 degree angle at the 1m height to fix the building security light fitting.
Taking down copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size minimum 2mm thickness and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with cement mortar 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per item No 42.00 here-in-before but one 3 pin socket outlet, 5/6 Amps, on independent board, with cable 1.5 Sqmm suitable concealed PVC/MS conduit complete all as specified and as directed.
All as per item No.42.00 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.
All as per item No.42.00 here-in-before but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.
All as per item No.42.00 here-in-before but for one light controlled by 2 Way switch using cable 1.5 Sqmm size for phase and neutral and 1.5 Sqmm for earthing with through existing PVC/MS conduit complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
S&F switch piano flush type 5/6 Amps SP two way complete all as specified and as directed.
S&F in repair bell push, flush type 5/6 Amps, complete all as specified and as directed.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and as directed.
S&F switch piano flush type 15/16 Amps SP one way complete all as specified and as directed.
S&F universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type complete all as specified and as directed.
S&F ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
S&F in repair lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
S&F in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 15 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed.
S&F in repair 12 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed.
S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed.
S&F in repair 12 Watt Rechargeable/inverter type LED bulb with inbuilt lithium-ion battery of minimum 2200 mAh, suitable for automatic lighting during power failure. Bulb have B-22 bayonet Cap, cool daylight colour temperature (approx 6500k), luminous output not less than 1200 lumens and backup time minimum 3 to 4 hours. The bulb shall be suitable for 220V-240V AC operation with overcharge and surge protection upto 4KV, complete all as specified and as directed.
Supplying of Panel light 2x2 ft. 36 Watt of Powder coated die cast / Extruded aluminium Body (Thickness >1.20 mm) and constructionas per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should bebelow 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum powerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). complete all as specified and as directed.
S&F in repair 36W Led Recess/Surface as per site requirement mounting 4'x1' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required for LED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed.
S&F in repair 16/18 Led Surface/Recess mounting as sper site requirement 1'x1' LED Luminaire having CRCA sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated . Fixture should have minium system Lumens of 1800lm &minium efficacy system level >100 Limen/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo LED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed.
M&L for point wiring with multi stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through suitable concealed/existing PVC conduit including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm multi stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good the disturbed surfaces of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour wash/white wash as the existing finishes etc. complete all as specified and as directed. Notes :- 1. The rate is inclusive of cutting/chasing and making good the distrubed surface in CM 1:3 and same surface to be finished with the adjoining surfaces with ODB/colour wash/white wash etc. complete. 2. At roof slab, where there is burnt/blockage in the existing conduit, wiring will be done through new PVC conduit and rates are inclusive in above quoted item. 3. The rate is inclusive for if old wiring is normal wiring, then new wiring for modular point wiring to be done. (a) One light /fan/Bell point/security light controlled by one way switch
All as per Srl item No.65.00 here-in-before, but for one 3 pin socket outlet 5 amps on same board
All as per Srl item No.65.00 here-in-before, but for one 3 pin socket outlet 5 amps on independent board with cable 1.5 Sqmm for main current and 1.5 sqmm as earth wire.
All as per Srl item No.65.00 here-in-before, but for 3/6 pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 2.5 Sqmm as earth wire as power point”
All as per Srl item No.65.00 here-in-before, but for One 3/6 Pin socket outlet, 20 Amp on independent board with cable 4 Sqmm for main current and neutral and 4 Sqmm as earth wire as AC point cable 4 Sqmm for main current and 4 sqmm as earth wire as power point.
S&F Switch modular type, 1 Module, 6 Amps one way complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 6 Amp complete all as specified and as directed.
S&F Switch modular type 1M, 16 Amp with red indication light complete all as specified and as directed.
S&F Socket outlet modular type 2M, 2/3 pin, 16 Amp complete all as specified and as directed.
S&F AC box with MCB 20 Amp complete with metal box and 3 Pin top plug complete all as specified and as directed. Note : Rates are inclusive of cutting/chases for mounting metal box on wall and making good the disturbed surfaces with OBD/Colour wash/ white wash and wall care putty etc, where ever required.
S&F in repair switch modular type, 1 Module, 6 Amps one way complete all as specified and as directed.
S&F in repair switch modular type, 1 Module, 6 Amps two way complete all as specified and as directed.
S&F in repair Bell push modular type 1M 5/6 Amp complete all as specified and as directed.
S&F in repair Socket outlet modular type, 2 in 1, 5 pin, 6 Amp complete all as specified and as directed.
S&F in repair Switch modular type, 16 Amp with red indication light complete all as specified and as directed.
S&F in repair universal Socket outlet 2 in 1 modular type 2M, 5 pin, 6/16 Amp complete all as specified and as directed.
S&F Socket outlet modular type, 2/3 pin, combined shuttered type 6 Amp complete all as specified and as directed.
S&F in repair universal Socket outlet 2 in 1 modular type 2M, 5 pin, 16 Amp complete all as specified and as directed.
S&F in repair metal clad socket with 20 Amp MCB and plug top complete all as specified and as directed.
S&F in repair of PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring complete all as specified and directed by Engr-in-Charge.
S&F in repairs bell ding dong type 230 V complete all as specified and directed.
Supply only PVC insulated FRLSH single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow&Black&green colour complete all as specified and as directed.
Supply only PVC insulated FRLSH single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement and directed in green colour complete all as specified and as directed.
Supply only PVC insulated FRLSH single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement and directed in Red/Blue/Yellow, Black & Green colour complete all as specified and as directed.
Supply only PVC insulated FRLSH 3 core with stranded copper cable of size 2.5 Sqmm as per site requirement complete all as specified and as directed.
Supply only PVC insulated FRLSH 2 core with stranded copper cable of size 1.5 Sqmm as per site requirement complete all as specified and as directed.
S&F in repairs sheet metal enclosure V TPN 4 way Double door DB, IP-54 bus bar neutral link earth bar and din rail with gasket etc. complete all as specified and as directed.
S&F in repairs sheet metal enclosure for DB when MCB to be used SPN 8 way with bus bar as per site requirement complete all as specified and as directed.
S&F in repairs sheet metal enclosure for DB when MCB to be used SPN 12 way with bus bar as per site requirement complete all as specified and as directed.
S&F in repair MCCB 3 pole 125 Amps 415 Volts with breaking capacity 16 KA, complete all as specified and as directed.
S&F in repair MCCB 3 pole 160 Amps 415 Volts with breaking capacity 16 KA, complete all as specified and as directed.
S&F in repair MCB TPN 63 Amps, 240 Volts with breaking capacity 10 KA, `C' curve, complete all as specified and as directed.
S&F in repair MCB TPN 100 Amps, 240 Volts with breaking capacity 10 KA, `C' curve, complete all as specified and as directed.
S&F in repair MCB SP 06 to 32 Amps 240 Volts, 10 KA, `C' curve, complete all as specified and as directed.
S&F in repair MCB SPN 40 Amps, 240 Volts, 10 KA, `C' curve, complete all as specified and as directed.
S&F in repair MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, complete all as specified and as directed.
M & L for sub main wiring using single core PVC FRLS grade insulated unsheathed, multisrand copper conductor cable 2 runs of 10 Sqmm for Phase and neutral and 1 run of 10 Sqmm for earth wire drawn through existing PVC/MS conduit and including replacement of unsv pressed steel terminal boxes of in wall as per suitable/existing dia with fittings like tees, bends junction/terminal boxes etc as per site requirement including taking down existing unserviceable sub main wiring twin core any size and complete all as specified and as directed. Notes : (a) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (b) Two runs of main cable and one run of earth cable all together shall be considered as one length. (c) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L in repairs Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering, all as shown in Electrical Plate No.05 of SSR-2009 (Part-I) and connected to earth test point including testing etc. complete all as specified and as directed.
Supply only plastic laminated sheet top cover 3mm thick of size 8"x5" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed.
Supply only plastic laminated sheet top cover 3mm thick of size 11"x9" fitted with MS galvanised screws and cup washer including shifting of all fixture from the old switch board and connection complete all as specified and as directed.
Supply only of plastic laminated circular fan box sheet for ceiling fan 3mm thick of fitted with MS galvanised screws and cup washer including of all fixture and connection complete as per sample complete all as specified and directed by Engr-in-Charge.
S&F in repair in repairs rigid PVC conduit 20mm dia including accessories tees, bends, reducer, cooption, riddles etc complete all as specified and directed.
S&F in repair 3 phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Note: old meter shall be deposited in MES yard.
S&F in repair 1 phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Note: old meter shall be deposited in MES yard.
S&F in repair of LED Garden Light (Bollard type) fitting, 10 Watt, in Mushroom shape, colour temperature 3000K (Warm White), system lumen efficacy not less than 100 lm/W, IP65 protection, die-cast aluminium housing with corrosion-resistant powder coating, UV stabilized polycarbonate/toughened glass diffuser, complete with inbuilt electronic driver having PF ≥0.95, THD <10%, surge protection 4 kV (inbuilt) & 10 kV (external), including necessary copper flexible wire connection of suitable size, testing and commissioning, complete all as specified and directed.
S&F in repair XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Vots grade, crpss sectional area 16sqmm 2 core complete with lugs, joints all as specified and directed by Engr in Charge.
PARAS ENTERPRISES (BID ID -3433748)
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3433359)
Vijeta Solutions (BID ID -3439984)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .