Gurgaon PHED
Providing of gaseous chlorination system
2024_HRY_407054_1
20248D158181 288B 4385 A9C2 EBD4031843DC557PUH
Open Tender
Civil Works
365 days
Almudinpur BABRA BAKIPUR Bhasunda BIRHERA Fari
2 documents required · 2 mandatory
₹20,000
₹26.1 L
Yes
24 Mar 2025
25 Oct 2024
19 Nov 2024
25 Oct 2024
18 Nov 2024
25 Oct 2024
Designing, providing, fixing, testing and commissioning of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/ hrs. as designed having the control of gas upto 20th part of max. dose . The complete system consists of (a) Vacuum regulator (b) Measuring Glass Tube (c ) Ejector (d) PF tubing (e) Spanner with cylinder opening key (f) Ammonia Gas (Liquid for leaking test) (g) 1’ dia PVC pipe with PVC fitting, ball valves etc. (h) 2 Nos. chlorine gas cylinder capacity 100 Kg. duly certified and approved by BIS and Explosive Department Govt. of India (i) Electronic Chlorine gas leak detector with sensor and hooter (j) Full face mask with canister as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER FOR RESIDUAL CHLORINE AND TURBIDITY including RTU-Cum-Gateway with Cellular (GSM, GPRS,4G/L TE,5G, NB-IoT), LoRa or other RF technology for remote data transfer as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024
``Designing, Supply and erection of PETROL GENSET set of 10 KVA capacity with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for Petrol Genset complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Petrol Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch (on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` `
Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make , general insurance of system, SIM data cost, network and cloud storage etc for 1st year after trial period of three months and defect liability period of one year
Comprehensive maintenance of complete system under this D NIT in all respect including replacement of any part and consumables including reagents of original make , general insurance of system, SIM data cost, network and cloud storage etc for 2nd year
Comprehensive maintenance of complete system under this D NIT in all respect including replacement of any part and consumables including reagents of original make , general insurance of system, SIM data cost, network and cloud storage etc for 3rd year
Comprehensive maintenance of complete system under this D NIT in all respect including replacement of any part and consumables including reagents of original make , general insurance of system, SIM data cost, network and cloud storage etc for 4th year
Comprehensive maintenance of complete system under this D NIT in all respect including replacement of any part and consumables including reagents of original make , general insurance of system, SIM data cost, network and cloud storage etc for 5th year