| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.7 LAccepted-Finance S 29 2 GNS PLAZA I SITE IV KASNA ROAD GREATER NOIDA UTTAR PRADESH 201301 | GREATER NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L1 | Accepted-Finance L1 bidder | |
| 2 | L2₹99.2 L+₹9.5 L (10.6%)Accepted-Finance | L2 | Accepted-Finance L2 bidder | |
| 3 | L3₹1.3 Cr+₹43.5 L (48.5%)Accepted-Finance KHASRA NO 200 GHOSI ROAD GHOSI MAU UTTAR PRADESH 275305 | MAU | UTTAR PRADESH | 275305 | L3 | Accepted-Finance L3 bidder |
Tender Value
₹34 L
EMD Value
₹70,000
Closing Date
24 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE OMC4 CTPS PTPP PARICHHA JHANSI
OFFICE OF SE OMC4 CTPS PTPP PARICHHA JHANSI
Biennial Rate Contract for repair rewinding and re insulation of 6.6 KV motors ranging from 200 KW to 4600 KW of units 3 and 4 of 2x210 MW and units 5 and 6 of 2x250 MW PTPP Parichha Jhansi
2025_RVUNL_1011934_2
N-PAR/C/OMC4/EMD1/6000007138
Open Tender
Electrical Works
Item Rate
730 days
PARICHHA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DY CAO CFA AND BO PTPP PARICHHA
₹70,000
19 Jul 2025
2 Apr 2025
25 Apr 2025
2 Apr 2025
24 Apr 2025
2 Apr 2025
Amount
Provision of New Coils as per applicable scope of work for Category- I Motors 340 – 375
Provision of New Coils as per applicable scope of work for Category- II Motors 600 – 660.
Provision of New Coils as per applicable scope of work for Category- III Motors 1300-1600.
Provision of New Coils as per applicable scope of work for Category- IV Motors 3600.
Re-insulation of old coils as per scope of work for Category- I Motors 340 – 375.
Re-insulation of old coils as per scope of work for Category- II Motors 600 – 660.
Re-insulation of old coils as per scope of work for Category- III Motors 1300-1600.
Re-insulation of old coils as per scope of work for Category- IV Motors 3600.
Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- I Motors 340 – 375.
Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- II Motors 600 – 660.
Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- III Motors 1300-1600.
Complete Rewinding of stator with new or old reinsulated coils as per scope of work for Category- IV Motors 3600.
Replacement of damaged Motor Terminal Leads as per scope of work for Category- I Motors 340 – 375.
Replacement of damaged Motor Terminal Leads as per scope of work for Category- II Motors 600 – 660.
Replacement of damaged Motor Terminal Leads as per scope of work for Category- III Motors 1300-1600.
Replacement of damaged Motor Terminal Leads as per scope of work for Category- IV Motors 3600.
Complete Restaggering of Stator core as per scope of work for Category- I Motors 340 – 375.
Complete Restaggering of Stator core as per scope of work for Category- II Motors 600 – 660.
Complete Restaggering of Stator core as per scope of work for Category- III Motors 1300-1600.
Complete Restaggering of Stator core as per scope of work for Category- IV Motors 3600.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-I Bowl Mill Motor 340KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-I TAC Motor 350KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-I ACW Pump Motor 375KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-II CEP Motor 600KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work Sl. No 4.1 to 4.22 (Charges for new bars/end rings shall be payable as per Sl. No. 2a& 2b) Category-II FD Fan Motor 660KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-III PA Fan Motor 1300KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-III ID Fan Motor 1550KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per) Category-III CW Pump Motor 1600KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-IV BFP Motor 3600KW.
Cost of New bars for Category-I Bowl Mill Motor 340KW.
Cost of New bars for Category-I TAC Motor 350KW.
Cost of New bars for Category-I ACW Pump Motor 375KW.
Cost of New bars for Category-II CEP Motor 600KW.
Cost of New bars for Category-II FD Fan Motor 660KW.
Cost of New bars for Category-III PA Fan Motor 1300KW.
Cost of New bars for Category-III ID Fan Motor 1550KW.
Cost of New bars for Category-III CW Pump Motor 1600KW.
Cost of New bars for Category-IV BFP Motor 3600KW.
Cost of New End Ring for Category-I Bowl Mill Motor 340KW.
Cost of New End Ring for Category-I TAC Motor 350KW.
Cost of New End Ring for Category-I ACW Pump Motor 375KW.
Cost of New End Ring for Category-II CEP Motor 600KW.
Cost of New End Ring for Category-II FD Fan Motor 660KW.
Cost of New End Ring for Category-III PA Fan Motor 1300KW.
Cost of New End Ring for Category-III ID Fan Motor 1550KW.
Cost of New End Ring for Category-III CW Pump Motor 1600KW.
Cost of New End Ring for Category-IV BFP Motor 3600KW.
Brazing Charges Category-I Bowl Mill Motor 340KW.
Brazing Charges Category-I TAC Motor 350KW.
Brazing Charges Category-I ACW Pump Motor 375KW.
Brazing Charges Category-II CEP Motor 600KW.
Brazing Charges Category-II FD Fan Motor 660KW.
Brazing Charges Category-III PA Fan Motor 1300KW.
Brazing Charges Category-III ID Fan Motor 1550KW.
Brazing Charges Category-III CW Pump Motor 1600KW.
Brazing Charges Category-IV BFP Motor 3600KW.
Dynamic balancing of Rotor Category-I Bowl Mill Motor 340KW.
Dynamic balancing of Rotor Category-I TAC Motor 350KW.
Dynamic balancing of Rotor Category-I ACW Pump Motor 375KW.
Dynamic balancing of Rotor Category-II CEP Motor 600KW.
Dynamic balancing of Rotor Category-II FD Fan Motor 660KW.
Dynamic balancing of Rotor Category-III PA Fan Motor 1300KW.
Dynamic balancing of Rotor Category-III ID Fan Motor 1550KW.
Dynamic balancing of Rotor Category-III CW Pump Motor 1600KW.
Dynamic balancing of Rotor Category-IV BFP Motor 3600KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-I Bowl Mill Motor 340KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-I TAC Motor 350KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-I ACW Pump Motor 375KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-II CEP Motor 600KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-II FD Fan Motor 660KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-III PA Fan Motor 1300KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-III ID Fan Motor 1550KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-III CW Pump Motor 1600KW.
Repair of rotor shaft at Bearing Seat. as per scope of work Category-IV BFP Motor 3600KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-I Bowl Mill Motor 340KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-I TAC Motor 350KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-I ACW Pump Motor 375KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-II CEP Motor 600KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-II FD Fan Motor 660KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-III PA Fan Motor 1300KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-III ID Fan Motor 1550KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-III CW Pump Motor 1600KW.
Repair of rotor shaft at Coupling Seat. as per scope of work Category-IV BFP Motor 3600KW.
Removing rotor shaft bend/run out as per scope of work Category-I Bowl Mill Motor 340KW.
Removing rotor shaft bend/run out as per scope of work Category-I TAC Motor 350KW.
Removing rotor shaft bend/run out as per scope of work Category-I ACW Pump Motor 375KW.
Removing rotor shaft bend/run out as per scope of work Category-II CEP Motor 600KW.
Removing rotor shaft bend/run out as per scope of work Category-II FD Fan Motor 660KW.
Removing rotor shaft bend/run out as per scope of work Category-III PA Fan Motor 1300KW.
Removing rotor shaft bend/run out as per scope of work Category-III ID Fan Motor 1550KW.
Removing rotor shaft bend/run out as per scope of work Category-III CW Pump Motor 1600KW.
Removing rotor shaft bend/run out as per scope of work Category-IV BFP Motor 3600KW.
Re-shafting of rotor as per scope of work Category-I Bowl Mill Motor 340KW.
Re-shafting of rotor as per scope of work Category-I TAC Motor 350KW.
Re-shafting of rotor as per scope of work Category-I ACW Pump Motor 375KW.
Re-shafting of rotor as per scope of work Category-II CEP Motor 600KW.
Re-shafting of rotor as per scope of work Category-II FD Fan Motor 660KW.
Re-shafting of rotor as per scope of work Category-III PA Fan Motor 1300KW.
Re-shafting of rotor as per scope of work Category-III ID Fan Motor 1550KW.
Re-shafting of rotor as per scope of work Category-III CW Pump Motor 1600KW.
Re-shafting of rotor as per scope of work Category-IV BFP Motor 3600KW.
Provision of New Coils as per applicable scope of work for Category- I Motors 220 - 325 KW.
Provision of New Coils as per applicable scope of work for Category- II Motors 450 – 550 KW.
Provision of New Coils as per applicable scope of work for Category- III Motors 1500-1750 KW.
Provision of New Coils as per applicable scope of work for Category- IV Motors 4600.
Re-insulation of old coils as per applicable scope of work for Category- I Motors 220 - 325 KW.
Re-insulation of old coils as per applicable scope of work for Category- II Motors 450 – 550 KW.
Re-insulation of old coils as per applicable scope of work for Category- III Motors 1500-1750 KW.
Re-insulation of old coils as per applicable scope of work for Category- IV Motors 4600.
Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- I Motors 220 - 325 KW.
Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- II Motors 450 – 550 KW.
Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- III Motors 1500-1750 KW.
Complete rewinding of stator with new or old reinsulated coils as per applicable scope of work for Category- IV Motors 4600.
Replacement of damage motor terminal leads as per applicable scope of work for Category- I Motors 220 - 325 KW.
Replacement of damage motor terminal leads as per applicable scope of work for Category- II Motors 450 – 550 KW.
Replacement of damage motor terminal leads as per applicable scope of work for Category- III Motors 1500-1750 KW.
Replacement of damage motor terminal leads as per applicable scope of work for Category- IV Motors 4600.
Complete Re-staggering of stator core as per applicable scope of work for Category- I Motors 220 - 325 KW.
Complete Re-staggering of stator core as per applicable scope of work for Category- II Motors 450 – 550 KW.
Complete Re-staggering of stator core as per applicable scope of work for Category- III Motors 1500-1750 KW.
Complete Re-staggering of stator core as per applicable scope of work for Category- IV Motors 4600.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-I TAC Motor 220KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-I ACW Motor 250KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-I BAHP Motor 280 KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-I CEP Motor 325 KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-II Mill Motor 450 KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per ) Category-II FD Fan Motor 550 KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-III CW Motor 1500KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-III PA fan Motor 1650KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per Scope of work) Category-III ID fan Motor 1750KW.
Complete rotor core Re-staggering including replacement of rotor bars & end rings damaged /damaged during dismantling of rotors including brazing charges and Dynamic Balancing of Rotor but excluding charges for new bars/end rings as per scope of work (Charges for new bars/end rings shall be payable as per scope of work) Category-IV BFP Motor 4600KW.
Cost of new bar for Category-I TAC Motor 220KW.
Cost of new bar for Category-I ACW Motor 250KW.
Cost of new bar for Category-I BAHP Motor 280 KW.
Cost of new bar for Category-I CEP Motor 325 KW.
Cost of new bar for Category-II Mill Motor 450 KW.
Cost of new bar for Category-II FD Fan Motor 550 KW.
Cost of new bar for Category-III CW Motor 1500KW.
Cost of new bar for Category-III PA fan Motor 1650KW.
Cost of new bar for Category-III ID fan Motor 1750KW.
Cost of new bar for Category-IV BFP Motor 4600KW.
Cost of new end ring for Category-I TAC Motor 220KW.
Cost of new end ring for Category-I ACW Motor 250KW.
Cost of new end ring for Category-I BAHP Motor 280 KW.
Cost of new end ring for Category-I CEP Motor 325 KW.
Cost of new end ring for Category-II Mill Motor 450 KW.
Cost of new end ring for Category-II FD Fan Motor 550 KW.
Cost of new end ring for Category-III CW Motor 1500KW.
Cost of new end ring for Category-III PA fan Motor 1650KW.
Cost of new end ring for Category-III ID fan Motor 1750KW.
Cost of new end ring for Category-IV BFP Motor 4600KW.
Brazing Charges for Category-I TAC Motor 220KW.
Brazing Charges for Category-I ACW Motor 250KW.
Brazing Charges for Category-I BAHP Motor 280 KW.
Brazing Charges for Category-I CEP Motor 325 KW.
Brazing Charges for Category-II Mill Motor 450 KW.
Brazing Charges for Category-II FD Fan Motor 550 KW.
Brazing Charges for Category-III CW Motor 1500KW.
Brazing Charges for Category-III PA fan Motor 1650KW.
Brazing Charges for Category-III ID fan Motor 1750KW.
Brazing Charges for Category-IV BFP Motor 4600KW.
Dynamic balancing of rotor for Category-I TAC Motor 220KW.
Dynamic balancing of rotor for Category-I ACW Motor 250KW.
Dynamic balancing of rotor for Category-I BAHP Motor 280 KW.
Dynamic balancing of rotor for Category-I CEP Motor 325 KW.
Dynamic balancing of rotor for Category-II Mill Motor 450 KW.
Dynamic balancing of rotor for Category-II FD Fan Motor 550 KW.
Dynamic balancing of rotor for Category-III CW Motor 1500KW.
Dynamic balancing of rotor for Category-III PA fan Motor 1650KW.
Dynamic balancing of rotor for Category-III ID fan Motor 1750KW.
Dynamic balancing of rotor for Category-IV BFP Motor 4600KW.
Repair of rotor shaft at bearing seat for Category-I TAC Motor 220KW.
Repair of rotor shaft at bearing seat for Category-I ACW Motor 250KW.
Repair of rotor shaft at bearing seat for Category-I BAHP Motor 280 KW.
Repair of rotor shaft at bearing seat for Category-I CEP Motor 325 KW.
Repair of rotor shaft at bearing seat for Category-II Mill Motor 450 KW.
Repair of rotor shaft at bearing seat for Category-II FD Fan Motor 550 KW.
Repair of rotor shaft at bearing seat for Category-III CW Motor 1500KW.
Repair of rotor shaft at bearing seat for Category-III PA fan Motor 1650KW.
Repair of rotor shaft at bearing seat for Category-III ID fan Motor 1750KW.
Repair of rotor shaft at bearing seat for Category-IV BFP Motor 4600KW.
Repair of rotor shaft at coupling seat for Category-I TAC Motor 220KW.
Repair of rotor shaft at coupling seat for Category-I ACW Motor 250KW.
Repair of rotor shaft at coupling seat for Category-I BAHP Motor 280 KW.
Repair of rotor shaft at coupling seat for Category-I CEP Motor 325 KW.
Repair of rotor shaft at coupling seat for Category-II Mill Motor 450 KW.
Repair of rotor shaft at coupling seat for Category-II FD Fan Motor 550 KW.
Repair of rotor shaft at coupling seat for Category-III CW Motor 1500KW.
Repair of rotor shaft at coupling seat for Category-III PA fan Motor 1650KW.
Repair of rotor shaft at coupling seat for Category-III ID fan Motor 1750KW.
Repair of rotor shaft at coupling seat for Category-IV BFP Motor 4600KW.
Removing rotor shaft bend/run out for Category-I TAC Motor 220KW.
Removing rotor shaft bend/run out for Category-I ACW Motor 250KW.
Removing rotor shaft bend/run out for Category-I BAHP Motor 280 KW.
Removing rotor shaft bend/run out for Category-I CEP Motor 325 KW.
Removing rotor shaft bend/run out for Category-II Mill Motor 450 KW.
Removing rotor shaft bend/run out for Category-II FD Fan Motor 550 KW.
Removing rotor shaft bend/run out for Category-III CW Motor 1500KW.
Removing rotor shaft bend/run out for Category-III PA fan Motor 1650KW.
Removing rotor shaft bend/run out for Category-III ID fan Motor 1750KW.
Removing rotor shaft bend/run out for Category-IV BFP Motor 4600KW.
Re-shafting of rotor as per scope of work Category-I TAC Motor 220KW.
Re-shafting of rotor as per scope of work Category-I ACW Motor 250KW.
Re-shafting of rotor as per scope of work Category-I BAHP Motor 280 KW.
Re-shafting of rotor as per scope of work Category-I CEP Motor 325 KW.
Re-shafting of rotor as per scope of work Category-II Mill Motor 450 KW.
Re-shafting of rotor as per scope of work Category-II FD Fan Motor 550 KW.
Re-shafting of rotor as per scope of work Category-III CW Motor 1500KW.
Re-shafting of rotor as per scope of work Category-III PA fan Motor 1650KW.
Re-shafting of rotor as per scope of work Category-III ID fan Motor 1750KW.
Re-shafting of rotor as per scope of work Category-IV BFP Motor 4600KW.
LT (0.4 KV) Motor Rewinding Works as per scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole)
Repair of Rotor Shaft at Bearing Seat as per Scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole).
Repair of Rotor Shaft at Coupling Seat as per Scope of Work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole)
Removing rotor shaft bend/ run out as per scope of work for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole)
Dynamic Balancing of Rotor for Category-V motor (Vacuum pump 0.4KV,110KW, 12 Pole).
M.S.JASWINDER & CO. (BID ID -5141445)
Basant Enterprises (BID ID -5142619)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .