Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹71.3 L+₹3.8 L (5.70%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹76.0 L+₹8.5 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹79.2 L+₹11.7 L (17.4%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹85.8 L+₹18.3 L (27.2%)Rejected-Finance S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹79.3 L
EMD Value
₹1.4 L
Closing Date
11 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
PROVN OF 100 KVA TRANSFORMER ONE 100 KVA VOLTAGE STABILIZER AND TWO 30 KVA VOLTAGE STABILIZER 100 KVA GENERATOR SET AND ALLIED INFRA FOR OT OF 319 FILED HOSPITAL AND CERTAIN SANCTIONED WORK UNDER GE 969 EWS
2022_MES_551292_1
CWEK-39/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 969 EWS
Class C Category b ii
7 documents required · 7 mandatory
₹1,000
GE 969 EWS
₹1.4 L
HQ 133 WORKS ENGRS
6 May 2023
12 Sept 2022
18 Oct 2022
12 Sept 2022
11 Oct 2022
27 Sept 2022
12 Sept 2022 - 18 Sept 2022
23 Sept 2022
Amount
Supply, installation, testing and commissioning outdoor type, trolley mounted stepdown transformer, 11 KV/415 volts (at full load) AC 3 phase 50 HZ, 250 KVA capacity, core type, double copper wound, Oil immersed, naturally cooled, oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ±5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 55 degree celsius. The transformer shall be IS-1108 marked.
Supply, installing , testing and commisioning step down Transformer, outdoor type , HT 11 KV, 3 phase, LT 433 volts, 50 Hz ,3 phase 4 wire Oil cooled, capacity 100 KVA copper wound in accordance with vector group DYN 11 with neutral brought out on LV side with tapping on HV side to vary secondary voltage upto +or - 7.5 % instep of 2.5% with externally operated off load type tap changing switch ,locking arrengement complete, all as per IS:1180 (Part-I) : 2014 (Latest Version) with all standard fittings all as specified and directed. Note : The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates).
Supply installation Testing & Commissioning of ECO friendly Diesel Engine driven generating set of 100 KVA, BHP 156, CPCB-II nearest higher side 400/440 volts, AC 3 phase, 50 HZ , 4 wire, 0.8 PF directly coupled alternator and engine water cooled with AMF Panel common steel base fixed on Cement concrete in foundation as per OEM recommendation DG set of 100 KVA platform with inbuilt AMF panel as per manufacturer recommendation and other accessories comprising of following. Note :- 1. The DG Set should be design considering the derating factor of altitude 5000ft above sea level (Pattan) extreme cold climate in winters. The ambient temp varies from -2 degree C (in winter) to 35 degree C (in summer).
a) ENGINE- ECO friendly for emisson and noise (PCB NORM COMPLIACE) 4 stoke diesel Engine confirming to BS std developing 156 BHP @ 1500 RPM turbocharged watercold complete with a provision for 10% overload for one hour on 100 KVA. (i) Fly wheel with starter ring for generating set. (ii) Dry type Air filter. (iii) Lub oil cooler assembly with accessories. (iv) Exhaust air manifold. (v) Exhaust silencer. (vi) Expension bellow. (vii) Exhaust gas turbocharger. (viii) Fuel filter (pree micro) (ix) Lubricantion oil filter. (x) 12V electrical starting system with starting motor & battery charging alternator with self starter and other auto electric accessories as recomanded by manufacturer. (xi) Centrifugal by-pass filter. (xii) Front & rear engine mounting supports. (xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, electronic Hour meter, speedometer. (xiv) Safety against low lub oil pressure. (xv) Engine operation/Maintenance, spare parts Manual. (xvi) Engine test certificate. (xvii) Cold starting kit .
b) ALTERNATOR- Sailent pole brushless type suitable for direct couple to engine self excited, self regulated with fast response thyristor type electronic automatic voltage withhold out put voltage with in desired limit(+1%) Dynamically balanced 400/415 volts AC 3 phase 50 HZ, 4 wire 0.8 PF lagging 100 KVA 1500 RPM star connected (4 wire) screen protected drip proof enclousers with radial fan mounted on rotor with insullation class- F/H and with stand an over load of 10% for one hour in every 12 hours operation ambient temperature varies from -2 degree C in winter to 35 degree C in summer (Pattan) with following accessories.(i) One MS frame suitable for mounting of Engine & alternator. (ii) Fuel tank of suitable capacity as per Manufacturer recommendation complete with fuel gauge inlet/outlet connections drain valve with plug etc. (iii) Battery of suitable capacity as per manufacturer recommendaiton with copper leads and terminals of suitable size (iv) One set of AVM pads fitted on base frame. (v) One hand operated rotory type pump connected.with HD pipe of length 10 Mtrs.
C) Acoustic enclosure- Supply & install of Acoustic Enclosure suitable for 100 KVA DG set as under.i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets. (iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg /M3 coverd with fiber glass cloth and perforated powder coats sheet specialy designed allenuators (Sound controller) at air entry and exit of the container noice level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. (iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. (v) Emergency stop push button out side the container. (vi) Provn of light inside the canopy 20W LED fitting with wiring and control switch
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 20 KVA complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 30 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 20 KVA complete all as specified and directed.
M&L for four wheeled trolley with flatted platfrom for mounting of 250 KVA transformer alongwith LT Panel and and cable all as directed Note : The appx length of trolley is 3.9 mtr made of pipes in trianglar pitch and welded to two end flanges (cylindrical in shape) the rigidity end Haujes and welded together by 6 tie rods. Both end of pipes are second by cover which are provided with handles. The overall length and diameter 2620mm and 2602mm.. The weight is appx 300 KG. the above paut stauls at 775mm from the bottom and non active porting of 245mm at top. All external components are made of stainless steel. The top structure is fabricated rectangula steel frame having appx dia mention of 3800 mm (L) X 3000 mm (W) X 345 mm (H). The two heavy duty wheels at the front and two heavy duty wheels at the rear end (a) Loading platform ht 700mm appx from the ground (b) Ground clearnance = 50-100 mm (c) No of axle lines = 2 Nos (d) Type of wheels = With flages for movement of the rail (e) No of wheels = 4 Nos (f) Wheel pitch = 2500 mm appx Rail System : Two parallel rails shall be weldede on ground channels in a such way that top surface of rails are the holt to the floor level. The two paralled channel (ISMC 200 as per IS808) embedded to the floor to the floor with their neutaal separated by a distace 2500mm. LT Panel : Panel of 3.156mm thickness CPRI approved with one incoming MCCB 350 Amp and 02 Nos outgoing MCCB 200 Amp, aluminium bus bar fixed with trolley Note : Contractor should approved drawing by Engr in Charge before supply
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed.
Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-55 (11.0 metres long) including drilling of holes of reqd size for fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portion embedded in concrete, making five black & red bands at lower portion of pole each 300 mm wide alternately,and marking pole NO.with black paint at suitable height complete all specified and directed.
S & F Cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
M&L for Lighting arresters expulsion type complete with all fittings transmission class, discharge capacity 65KA suitable for 11000 volts complete all as specified and directed.
M&L for Switch air break, gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps 11000 volts (12 Insulator) alongwith fuse system complete all as specified and as specified.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 3 Core 95 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 240 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 120 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 95 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 70 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 50 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 Core 25 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2 Core 25 Sqmm, ISI marked complete, all as specified and as directed.
Supply and laying in cable, XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 Core 16 Sqmm, ISI marked complete, all as specified and as directed.
Supply and fixing of MCCB 4 Pole, 415 V,with Adjustable type setting 63 Amps with breaking capacity 25 KA, complete all as specified and directed.
Supply and fixing of MCCB 3 Pole, 415 V, with fixed type setting , 63 Amps, with breaking capacity 16 KA, complete all as specified and directed.
Supply and fixing of MCCB 3 Pole, 415 V, with fixed type setting, 100 Amps, with breaking capacity 16 KA, complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V,with Adjustable type setting 160 Amps with breaking capacity 36 KA, complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V, with Adjustable type setting, 200 Amps with breaking capacity 36 KA complete all as specified and directed.
Supply and fixing of MCCB 4 Pole, 415 V, with Adjustable type setting , 400 Amps with breaking capacity 36 KA complete all as specified and directed.
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium graded ,GI medium graded 20mm bore watering pipe
M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth lead 4 mm and protection pipe of 40 mm bore medium graded ,GI medium graded 20mm bore watering pipe
Supply and fixing sheet metal enclosures for DBs when MCBs to be used Verticle Ttriple Pole & Neutral (VTPN) double door 415 volts, 6 way with IP-43 IK-09 protection including 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed.
Supply and fixing sheet metal enclosures for DBs when MCBs to used single pole and neutral (SPN) double door 240 volts, 12 way with IP-43 IK-09 protection incl. 200 Amp bus bar and neutral link (ISI marked) complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series (ISI marked) complete all as specified and irected.
S&F MCB Double Pole (DP) 6 to 32 Amps with 10 KA breaking capacity of 'B' series (ISI marked) complete all as specified.
M&L for Sub main wiring with 2 runs of 6 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 6 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring complete all as specified and as directed.
Supply and fixing ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amp complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
All as per item No 41 here-in-before above but in depth exc 1.5mtr and not exc 3m complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-charge.
Removing surplus exacavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed.
Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
M & L Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
M & L for cement concrete for foundation fillings and mass conctere type D2 1:4:8 (using 40 mm graded aggregate) complete all as specified and directed.
M & L for cement concrete for coping of poles using B-1 1:2:4, (using 20 mm graded aggregate), smooth finishing without using extra cement complete all as specified and directed.
M & L for cement concrete for mass fillings of poles, conctere type C2 1:3:6 (using 40 mm graded aggregate) complete all as specified and directed.
M&L for Construction of shed for suitable for 100 KVA Transformer including steps,plinth protection,cable duct complete all as specified and directed as shown on drawing NO CESZ/TD-1110/2011 sheet 1/2 and 2/2 Dated 01/12/2011
M&L for Construction of shed for suitable for 100 KVA DG Set including steps,plinth protection,cable duct complete all as specified and directed as shown on drawing NO CESZ/TD-1110/2011 sheet 1/2 and 2/2 Dated 01/12/2011
M/S KULBIR SINGH SODHI AND CO
Roy and Sons Infrastructers
M/S Noor Mohammad Shalla
ALCO ENGINEERSPVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .