Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC PLOT NO 12 SAKAR GRAH NIRMAN SOCIETY TILHARI MANDLA ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MP | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹44.2 L+₹4.5 L (11.2%)Rejected-Finance 37A 115 MADHU NAGAR AGRA 282001 UP | AGRA | AGRA | UP | 282001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.5 L+₹6.8 L (17.0%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.8 L+₹7.1 L (17.9%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
13 Jan 2022, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF CERTAIN SPECIAL REPAIR AND MINOR WORK IN THE AREA OF AGE B/R-II UNDER GE (WEST) JABALPUR
2021_MES_491010_2
8394/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹94,000
19 Jan 2022
23 Dec 2021
15 Jan 2022
23 Dec 2021
13 Jan 2022
30 Dec 2021
24 Dec 2021 - 28 Dec 2021
Amount
M&L for Bitumen mastic flooring made out including hacking and cleaning and applying one coat of primer bitumen paint on floor surfaces complete all as specified and directed by Engineer-in-Charge as following. (a) Well graded fine aggregates of crushed stone screening (b) Lime stone dust as filler and quality of bitumen grade 85/25 as per IS 702. The propotion of mixing of bitumen and fine aggregates (sand dust or sand) as per IS 1195.(c) Thickness of bitumen mastic flooring of 30mm Note: Mastic flooring must be carried by specialized agency as approved by GE and Engg-in-Charge.
Demolition of cement concrete of any descrip-tion and in any position not otherwise specifically provided for
M&L for 75 mm thick as in sub base in PCC 1:4:8 type D2(using 40 mm graded stone aggregate) etc all complete.
Supply and laying Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and lev- elled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface etc all complete
M & L for 75mm th PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete etc all as specified and directed.
M & L for providing, cement concrete type B1 1:2:4 (20 mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges etc all complete
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc all complete
S&F Machine pressed precast cement concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006of 80mm thickness M 40 Grade fixed over and including 50mm thick sand coushning complete etc all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc
M & L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:6) & top layer of 5mm thick in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid saperately.)
M & L for rendering 5mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete etc all as specified
M & L for applying two coats of cement based paint on one coat of primer on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
M & L for applying three coat of white wash on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified.
M & L for applying two coat of white wash on newly plastered or unplastered on ceiling surfaces including preperation of surfaces, etc complete all as specified.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime morter including all quoins, arches,pillers etc, but excluding ashlar facings, dressed stone-work and precast concrete aeticles.
M&L for brick work with kiln burnt bricks built in cm (1:6) using sub class 'b' bricks of compressive strength not less than 35kg/sqcm straight or curved on plan exceeding 6 mtr mean radius.
Ditto all as per item above but except brick
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
S&F Steel rolling shutters with 1.25mm thick laths with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated,gear operated type with bevel gear boxes and crank handle complete all as specified.
Taking down chowkat or frame with shutter (without taking off shutters from frame ) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each & Refixing in Same Opening
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde-E- 250)quality
S & F Mild steel (1.25 mm Thickness), plain, blacksheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Dismantling of structural steel of any description and in any position
S&F framed work such as grills, gratings etc with ends of bars shouldered and or reiverted or forged into spikes, framed guard bars and similar work conferming to Fe 410-0 or Fe 310-0
M&L for complete removal of existing water proofing treatment from top of roof and canopies / chajjas of building including removal of debris out side MD land all as directed.
M&L for Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning & drying the concrete surfaces complete (a) M&L 10 mm thick rendering on roof surfaces/concrete surface in CM 1:3 complete. (b) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. (c) Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces. (d) Laying unrolled over the bitumen coated surface,3 mm thick polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction. (e) Applying two coats of bituminous base aluminium paint including preparation complete
Dismantling timber scantlings 40 sq. cm in section as in rafter ,purlin,unframed work etc all as specified.
M&L rolled sections as in main runs, cross beam, hip and jack rafters purline where connected to common rafter and running rails and guides for sliding door fixed with angle cleats or other connecting plates.
Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings
S&F Pre-painted galvalume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
S&F 5 to 10mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 5 cm and n exc 10 cm
S&F 11 to 15mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other end, or screwed both ends, each screwed and to fitted with washers and one hexagonal or square nut exc 10 cm and n exc 15 cm
S&F mild steel plates welded to MS pipe complete and confirming to gde Fe- 410-0 or fe- 310-0
M&L for 2 coat of synthetic enamel painting over a coat of red oxide primer incl preperation of new steel surface not exc 10cm width or girth etc all complete
M&L two coat of syntetic enamel paint over new steel surface of any description over 10cm in width or grith not otherwise described over one coat red oxide primer incl preparation of new steel surfaces complete.
S&F FI 40 x 6mm as in wind tie all as specified and directed
M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded granite stone aggregate) as in sub base of floorings to receive top finish.
M & L for Machine cut Kota stone slab flooring 18-22 mm thick fixed over and including cement screed base 15mm thick in cm 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc all complete.
M&L for Kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar laid over and including 10 mm thick cement morter (1:4) as backing coat etc and jointed with grey cement slurry mixed with pigment to match the shade of the slab incluring rubbing and mirror polshing etc all complete.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
Supply only Integral Water proofing compound.
S & F Steel window with side hung shutters incl projecting type hinges with steel handle , steel peg stay, complete with glazing bars, dovetailed and welded.or ventilators, fixed type, with glazing bar complete all as specified and directed.
Taking down chowkats or frames n exc1.5 sqm with shutter (without taking off shutters from the frames).
Taking down chowkats or frames exc 1.50sqm but n exc 4 sqm with shutter (without taking off shutters from the frames).
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples beads or in steel window complete all as specified and directed by Engr-in-charge.
S&F 3mm thick sheet glass ordinary quality and galzing with oil putty or wooden beads in squares of any size complete all as specified and directed by Engr-in-charge.
M&L for colour Chequered cement concrete tiles 20cm x 20cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigments fixed over & including screed bed 15 mm thick CM 1:4 etc all complete.
Excavation in post holes (or similar holes) each n. exc 0.5 cum, getting out in any type of soil and including returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm etc all complete
M&L for 100 mm thick PCC 1:2:4, Type B2, using 40 mm graded stone aggregate as in paving/path finished fair and even etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in coloumns, pillars and posts
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E-165)
S & F mild steel bolts exc 20 & n, exc 25mm dia, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0
Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out any type of soil complete all as specified and directed.
Excavation in trenches, n exc 1.5m wide and exc 1.5m but n.exc 3.0m in depth for fdn etc or for shafts wells, manholes pier holes etc n.exc 10 Sqm on plan and in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, sub base complete all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses etc and similar work including necessary form work complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
S&F TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
S&F Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
S&F Steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep and n exc 3 m getting out in any type of soil complete all as specified and as directed.
M&L for RCC Design Mix M 25 Type B1 OF 20mm graded stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, walls,retaining walls ,basement walls under-reamed piles and mass concrete
Form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately) complete all as specified and directed.
Supply & laying DWCP 200 mm dia pipes in trenches class SN-8 conforming to IS 16098 (Part 2) in 6 mtr length with coupler complete all as specified and directed by Engr-in-charge
M & L for solid wall DWCP socketed drain pipes class SN-8, conforming to IS 16098 (Part-2) with 150 mm bore dia in 6m length including laying and jointing complete all as specified and as directed
S & F MS works for fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets, MS Rungs (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L brick work with sub class'B' bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and as directed.
M & L for 200mm thick Cement concrete type B-2, 1:2:4, using 40mm graded stone aggregate as in hardstanding complete all as specified and directed.
M&L for Extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
S & F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S & F 110mm PVC (SWR) vent cowl
S & F Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:6
M & L of broken bricks Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells etc all complete.
M&L for RCC Design Mix M 25 Type B1 OF 20mm graded stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, walls,retaining walls ,basement walls under-reamed piles and mass concrete
Form work to face of walls,curved surface of walls, retaining walls. Including attached pillasters & buttresses.
S&F GI tubes 50 mm bore medium grade galvansied with all fittings, fixed to walls and ceilings or laid in floors complete.
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces all as specified and directed by Engineer in charge.
Taking down the ceiling fan in situ and refixing after servicing, repairing and painting to ceiling fan including scratching old paint and preparation of surface for painting with one coat of white/grey enameled paint complete all as specified and directed.
S&F in repair Sub Main Wiring four single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and two run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :-Four of 6.0 Sqmm Wire and two No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length.
S&F in repair Sub Main Wiring with two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 20mm dia with all conduit fitting,fixing accessories and 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.00 Sqmm Wire and One No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light/fan point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point controlled by one switch on same board.
(c) One socket point controlled by one switch on Independent board.
Ditto all as per above items but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 1.5 Sqmm solid copper conductor PVC for 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge .
S & F Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S & F Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F fan regulator Step type of polycarbonate complete all as specified and directed by Engineer in charge.
S & F lamp holder PVC Polycarbonate type body, with back plate for batten fitting icluding 9 watt led lamp complete all as specified and as directed by Engineer in charge.
S & F in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed.Make : Philips Cat part BN 021 LED 22S 6500/4000 PSU GR SI or equivalent
S & F in repair Bulk head endura LED light fitting complete with 10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Havells Cat Part No. RUGBY NEONFT10WLED760SSYMBOP/ BIBWP10W LED OF bAJAJ Equivalent SURYA SLEBLH 10 / Philips / Crompton
Supply & fix in replacement of LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.Make: Surya cat part no :Lexon SLE UL 25W IP66 or HAVELLS Cat part no LHDAUU7PA7J025 VLUMINA or Equ in philips,luker.
S & F in repair Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge Make- Legrand cat part No.- 5076 21 L&T, ABB.
S & F in repair Sheet metal enclosure DBs Tripple Pole and Neutral 4 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge.Make- Legrand cat part No.- 5077 80 , L&T, ABB.
S & F in repair MCB TPN 415 volts 63 Amps, C Series complete all as specified and directed by Engineer in charge.Make- Legrand , L&T, ABB.
Supply and fixing in replacement MCB single pole and neutral 240 volts 40 Amps, C Series complete all as specified and directed by Engineer in charge.Make- Legrand , L&T , ABB.
Supply and fixing in replacement MCB single pole 240 volts upto 40 Amps, C Series complete all as specified and directed by Engineer in charge. Make- Legrand,L&T,ABB.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. -1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fixing in repairs integral post top lanterns complete with Black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories with 10watt LED lamp , GI pipe as required to fix in gate piller complete all as specified and directed .Make:Havells cat part no :RUBYMINIPT15WLED757PSYMTOPC or eqv in philips ,
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 16 Sqmm complete all as specified and directed by Engineer in charge
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size 50 mm outer dia and 38 mm inner dia of Make;-Telerex/Tirupati or E-in-C approved Make
S&F GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply , laying, testing and commissioning LT underground cable 1100 volts grade, XLPE insulated , 10 Sqmm 2 core screened, PVC sheathed Heavy duty armoured with multi stranded aluminium conductor laid in pipes, trenches/ducts, on poles and wall etc of undermentioned sizes complete all as specified and directed by Engineer in charge.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts FRLSH grade drawn into and including concealed Steel conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
(a) One light point controlled by one switch.
Supply and fix Flame proof Switch rotary type switch 10 Amps SP ON/OFF complete with fixing arrangements all as specified and directed .
Supply and fixing flame Proof LED light fitting 1 x 20Watt and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size and type complete all as specified and as directed Make :- Prateek exlosion Cat Part No PE/EXLED/904236 or Eqvt in Sudhir, FCG,
Supply and fix Flame proof flexible connector for fixing of FLP Tubelight fitting/ any other reqd places complete all as specified and directed.
Supply and fix Flame proof bulk head fitting alumunium housing with suitable holder IP 65 protection fitting 1 x 30 W LED lamp complete with making connection all as specified and directed Prateek exlosion Cat Part No PE/EXBH/301030LED or Eqvt in Sudhir, FCG,
S&F dust proof totally enclosed junction box of 100x65 h suitable for fixing on wall , all as required and directed at site.
S & F in repair Sheet metal enclosure DBs Tripple Pole and Neutral 4- way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and directed by Engineer in charge.Make:Legrand cat part 5077 80 /Siemens/GE
Supply , laying and testsilng cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cab les ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and directed by Engineer in charge
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified in IS and all as shown in drawing No CEJZ/TD/824/91, Sheet No1/2 dt 16.04.91 with following specifications:- (i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level. (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work. (v) Necessary Cross arm required for fixing flood light
Supply and fixing in repair and connecting LED flood lights, not less than 100 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >80 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-65, Class I complete all as specified and directed by the Engr-in-charge, Make C&S Cat Part No LTEF100WHPLED or equivalent in Bajaj Havells, Philips
Supply & fix aluminium strip 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed by Engr - in - Charge .
S&F porceliene insulators 15 BMD type T with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC block of size 10cmX10cmX10cm height etc to avoid leakage of roof complete as directed.
S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw , drolled , cutting upper & lower portion for incoming & outgoing including double insulators including applying two coat of synthic enamel paint over one coat of red oxide primer etc all complete .
Supply and fix air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long etc all complete
Supply and errect vertically Galvanised, steel rod 16mm diameter and 2.5 metres length complete with fittings for raising height for air termination rods to site present requirements.
Earthing complete with galvanised steel earth plate 60×60cm ×3.15mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32×6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), cast iron frame, funnel with wire mesh,GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32×6mm with GI protection pipe of 15 mm medium grade 7.5 meter long, etc complete all as specified.
M/s Om Infracon
chandra builders
RAVI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .