Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC The quoted amount of L1 bidder is found competitive and reasonable overall, hence accepted | |
| 2 | L2₹15.5 L+₹2.6 L (19.8%)Rejected-AOC D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L2 | Rejected-AOC Being not the L1 | |
| 3 | L3₹16.7 L+₹3.8 L (29.0%)Rejected-AOC 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-AOC Being not the L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, St.Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS TO LOW TENSION EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS AT IN MAP ACCN, PO COLONY, USMAN LINE, OFFRS MESS, OTA OUTSIDE UNDER GE STM
2023_MES_628361_2
8384-REPAIRS TO LOW TENSION EXTERNAL ELECTRIC SUPP
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE STM
As per tender documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹30,000
Yes
21 Feb 2024
28 Dec 2023
1 Feb 2024
28 Dec 2023
24 Jan 2024
5 Jan 2024
28 Dec 2023 - 3 Jan 2024
Amount
Excavation in trenches n.exc 1.5 mar wide and n exec 1.5 mar in depth and getting out in soft/ loose soil for laying cables / GI pipe, foundation of pole, stay etc complete all as specified and as directed
Removing surplus excavated soil n.exc 50 mar and depositing where directed at a level n.exc 1.5 mar above the starting point complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed
Supplying and laying burnt Fly ash bricks class old standard size for protection of cable as directed.
Fine Sieved excavated dry Soil obtained from excavated soil laid to the required width of trench at bottom and top of cable as cushioning all as specified and as directed.
Taking out from trenches/ poles/ wall etc LT XLPE UG Cable / PVC Sheathed aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable size of following sizes : Note: Rate including Earth Work. The Jointing Kit shall be measured and paid separately under relevant Item
(a) LT UG Cable 2/ 3.5/ 4 core 6 Sqmm to 3.5 core 50 Sqmm
(b) LT UG Cable 3.5 core 70 Sqmm to 3.5 core 300 Sqmm
Taking down old UNSV UG Cables and taking as schedule of credit including, Supplying, laying, jointing and testing LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ ducts or fixed to poles/ walls or laid under roads/ paths/ drains/culverts complete all as specified and directed of following sizes:
(a) LT UG Cable 4 core 10 sqmm .
(b) LT UG Cable 4 core 16 sqmm .
(c) LT UG Cable 4 core 25 sqmm .
(d) LT UG Cable 3.5 core 35 sqmm .
(e) LT UG Cable 3.5 core 50 sqmm .
(f) LT UG Cable 3.5 core 70 sqmm .
(g) LT UG Cable 3.5 core 95 sqmm .
Supply and Fix in repairs Straight through joints Heat Shrink insulations and sealing system for underground cable including joint kits and labour complete for making joints suitable for LT XLPE/ PVC sheathed/ armoured heavy duty cables with aluminium conductor all as specified and as directed of following sizes:-
(a) 3.5/ 4 core 35 Sqmm
(a) 3.5/ 4 core 50 Sqmm
(b) 3.5/ 4 core 70 Sqmm
(c) 3.5/ 4 core 95 Sqmm
(d) 3.5/ 4 core 120 Sqmm
(e) 3.5/ 4 core 150 Sqmm
(f) 3.5/ 4 core 185 Sqmm
(g) 3.5/ 4 core 240 Sqmm
(h) 3.5/ 4 core 300 Sqmm
(j) 3.5/ 4 core 400 Sqmm
Taking down old UNSV Main switch/ Switch fuse Unit and taking as schedule of credit including Supply & Fix following MCCBs Thermal magnetic release type directly fixing to main board/ panel / walls including new alteration to panel with all necessary accessories all as specified and directed.
(a) MCCB 63A , 4 pole, 16 KA
(b) MCCB 100A , 4 pole, 16 KA
( c) MCCB 125A , 4 pole, 16 KA
(d) MCCB 160A , 4 pole, 35 KA
(e) MCCB 200A , 4 pole, 35KA
(f) MCCB 250A , 4 pole, 35 KA
Supply & Fix in repairs 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 200 Amps including taking out old unserviceable one directly fixing to main board/ panel / walls including all necessary accessories all as specified and directed.
Supply & Fix in repairs 3 phase 04 pole ON-LOAD / Change over Switch with advanced Neutral type of capacity 320 Amps including taking out old unserviceable one directly fixing to main board/ panel / walls including all necessary accessories all as specified and directed.
M&L in replacement for factory made sheet metal encloser (junction panel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40x40x6mm equal angle size of encloser not less than 75x60x30cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of rating 600 Amps suitable for one incoming and 5 out going feeders, mounted on insulators including disconnection of cable from the burnt bus bar and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, necessary earth work and PCC foundation for grouting of four legs all as per existing
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 10 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 16 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 25 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 50 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 70 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 95 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 120 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 150 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 185 Sqmm
Supply & Fix in repairs aluminium tube terminals (cable lugs) of size 240 Sqmm
Supply and fix in replacement of MCB Four pole 40 to 63 Amps 10 KA 'C' curve series ISI marked including necessary connections compete all as specified and as directed.
Supply and fix in replacement of push buttons with 1 NO / 1 NC, screw type for operation of capacitors all as per sample available at sub stations including necessary electric connections and testing including dismantling unserviceable push buttons (start/stop button) from the power factor capacitor panel boards complete all as specified and directed.
Supply and fix in repairs, LED indicating lamps of red/ yellow/ blue/ green / amber with bulbs including connection and testing complete all as specified and directed.
M&L for replacement of lock assembly with two nos keys for old/existing LT panel board any type/ size complete all as directed
S&F in repairs locking arrangement with aldrop bolt set complete of size 225mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified.
Supply only first-aid box with suitable basic medicines (As per medical norms).
S&F in repairs of steel tubes light grade of size 80mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete, including taking down old u/s GI tubing all as specified and as directed.
S&F in repairs of steel tubes light grade of size 50mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete, including taking down old u/s GI tubing all as specified and as directed.
S&F in repairs of steel tubes light grade of size 40mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate complete, including taking down old u/s GI tubing all as specified and as directed.
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sqmm nominal cross section in service connections incl necessary connection etc complete all as specified and directed.
Supply and laying in replacement of 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 6 sqmm nominal cross section in service connections etc complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Supply and fix /erect/ ground LT cable route indicator made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage, size of cable and route indicator fixed with angle iron of size 25 x25 x3 mm thick, 50 cm long embedded in PCC 1:2:4 type B1 of size 30 x 30 x 30 cm in ground all as specified and as directed
M&L for load balancing of Single/three phase system at LT Panel upto Distribution box of any size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/ carbonized aluminium tube terminal of any size and capacity all as specified and as directed Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium tube terminal of any size as per site reqmt change under the job deemed to be included in the quoted rate.
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete , necessary earthwork as required all as specified and as directed (Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate)
M&L for preparation of old painted surfaces of LT panel/ Feeder pillar box of any type including welding of damaged doors outdoor/ indoor including removing old paint with scrubbing and applying one coat of synthetic enamel paint of shade as per existing over a coat of red oxide primer, with electrically operated spray machine, complete all as specified and directed.
Repair of earth pit incl required excavation, earth work and PCC work to make good damaged/ disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/ strip with panel/ transformer using GI nut, bolts & washer complete all as specified & directed
M&L for checking of earth pit results, cleaning pit area complete, pouring of salt water as reqd in pit for maintaining of pit resistance up to less than 3 ohm complete all as specified and directed.
Material & Labour for Earthling complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level, connected to steel strip 25x4mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No.3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B-1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100mm centre to centre both ways and MS 6mm dia hook complete all as specified and directed.
Supply and fix in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above/below ground level including taking down old complete all as specified and as directed.
Dismantling and breaking down the existing, M&L for Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate for coping to pole foundation including necessary form work with fair finished surface all as directed.
Dismantling and breaking down the existing, M&L for Plain Cement concrete 1:4:8 type C-1 using 20mm graded stone aggregate for pole foundation, filling and mass concrete all as specified.
Complete servicing, overhauling, repairing, cleaning, oiling with setting of tripping mechanism of following Air Circuit Breakers (ACBs) including submission of service & test reports. The servicing to be done by authorised service provider of manufacturer. The details are placed at "Scope of work" as given under. Note :Minimum spares/ lubricants and tools required for the job should be included in the coated rates .
a) Air Circuit Breaker (ACB) 415 volts of capacity 630 amps to 1000 Amps 50Hz type/ make all as per existing SCOPE OF WORK i) Moving arcing contacts shall be checked. Cleaning of breaker with CRC-226 ii) Removal of old grease and re-greasing the same with recommended grease. iii) Check condition of arcing contact and gap between fixed and iv) Checking reset mechanism, tripping of breaker through push button v) Checking tripping of ACB through protection release vi) Tripping of ACB manually through volt metric release. vii) Checking and adjust freeness of DN and volt metric release trip rod viii) Checking presence and proper tightening of hardware. ix) Checking presence of all circles x) Checking condition and alignment of jaw contact with cradle terminals xi) Checking condition of ACB wiring and replace if required xii) Checking and adjusting gap between hylam sheet and side plate xiii) Checking proper closing of all poles together xiv) Checking working of anti pumping device. xv) Checking alignment of SIC and it’s operation xvi) Checking scrapping earth alignment xvii) Checking condition of arc chutes xviii) Checking U/V release pick up and drop off xix) Checking ACB tripping through shunt release xx) Checking continuity and proper changeover of aux contact block xxi) Checking of release by secondary injection for O/L, S/C, E/F xxii) Setting of release as per the load xxiii) Checking the healthiness of CTs
Supply only the following parts of Air Circuit Breaker (ACB) 415 volts 630 to 1000 Amps 50Hz,any type or make or all as per existing. The rate of fixing/ installation, testing is included in item No. 46
a) Closing Relay
b) Terminal Adaptors (4 terminals per Phase)
c) Relay Module
d) Shunt trip Release
e) Auxiliary Switch
f) Arc Chutes
g) Trip Push Buttons
h) ACB Position Indicator
Dismantling the existing squirrel gauge induction motor, rewinding with super enamelled copper winding of appropriate gauge and quality and insulated with varnish after removal of burnt out winding from slots with emery paper, including replacement of worn out bush, bearing, shaft metalling / grinding, reassembling and testing of capacity 7.5 HP complete all as specified and directed
Dismantling the existing squirrel gauge induction motor, servicing by overhauling, cleaning, greasing, lubricating, replacing worn out spares, reassembling and testing of capacity upto 7.5 HP complete all as specified and directed. It includes transport to workshop for repair for repair and return back to site fixing the motor connecting to electrical supply , testing and commissioning inclusive of testing and commissioning complete all as specified and directed. Note:- Any other small spares/ parts required for the job will be supplied and utilised for the job without any extra cost. Note:- (i). Spares as required shall be measured and paid separately as supply only under respective items. (ii) The labour element involved in replacing of parts shall deem to have been included in quoted rates of above item.
Supply only DOL starter with single phase preventer of suitable capacity with all accessories required as per site complete all as specified and directed.
Supply only ball bearing complete all as specified and directed.
Supply only shaft assembly with accessories complete all as specified and directed.
Supply only pulley bearing complete all as specified and directed.
Supply only terminal connector of suitable size complete all as specified and directed.
Supply only mild steel Nut, bolt & washer of suitable size complete all as specified and directed.
Preparation of surface by removing dust, emery paper, tinkering, applying metal putty wherever necessary and painting with two coats of synthetic enamel paint existing shade/colour of Squirrel gauge induction motor complete all as specified and directed.
Supply only mild steel foundation bolts, nuts and washers of suitable size as per site reqmt complete all as specified and directed.
Supply Fabricate, install, connect, testing and commissioning of LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:- INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 200A Amps with breaking capacity 16 KA. - 01 Nos OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160 Amps with breaking capacity 16 KA. - 01 Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 02 Nos (c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 04Nos (d) Multi function Meter with CT & PTs-01 No (e) Power Contactor 63 Amps (f) Digital Time Switch for Street Light Control (g) Phase indication lamps - 3 Nos. Note: All Changeover Switch/ MCCBs should be front handle operated.
Supply Fabricate, install, connect, testing and commissioning of LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and Existing cable of any size/ type to be connected with proper termination complete all as specified and comprising of the followings:- INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160A Amps with breaking capacity 16 KA. - 01 Nos OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 16 KA. - 02 Nos (c) Multi function Meter with CT & PTs-01 No (d) Power Contactor 63 Amps (e) Digital Time Switch for Street Light Control (f) Phase indication lamps - 3 Nos. Note: All Changeover Switch/ MCCBs should be front handle operated.
Supply Fabricate, install, connect, testing and commissioning of LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and existing cable of any size / type to be connected with proper termination complete all as specified and comprising of the followings:- INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 250A Amps with breaking capacity 16 KA. - 01 Nos OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160 Amps with breaking capacity 16 KA. - 01 Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 02 Nos (c) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 04Nos (d) Multi function Meter with CT & PTs-01 No (e) Power Contactor 63 Amps (f) Digital Time Switch for Street Light Control (g) Phase indication lamps - 3 Nos. Note: All Changeover Switch/ MCCBs should be front handle operated.
Supply, Fabricate, install, connect, testing and commissioning of LT electrical Feeder Pillar panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, IP 65 outdoor weather proof type, fabricated with 3.00 mm thick mild steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars of suitable capacity as per IS specification insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including painting of panel board with two coats of synthetic enamel paint over one coat of red oxide primer and existing cable of any size /type to be connected with proper termination complete all as specified and comprising of the followings:- INCOMING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 160A Amps with breaking capacity 16 KA. - 01 Nos OUTGOING :- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 100 Amps with breaking capacity 16 KA. - 01 Nos (b) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 10 KA. - 04Nos (c) Multi function Meter with CT & PTs-01 No (d) Power Contactor 63 Amps (e) Digital Time Switch for Street Light Control (f) Phase indication lamps - 3 Nos. Note: All Changeover Switch/ MCCBs should be front handle operated.
Supply and fix in replacement Battery Pack 30AH for LED Solar Street light including necessary electric connection and testing including taking out unserviceable Battery pack complete all as specified and directed.
Supply and fix in replacement 30W PIR sensor for LED Solar Street light including necessary electric connection and testing including taking out unserviceable PIR Sensor complete all as specified and directed.
Supply and fix in replacement LED driver suitable for LED Solar Street light including necessary electric connection and testing including taking out unserviceable LED drive complete all as specified and directed.
Finding and rectification of electrical fault by Checking of external/ internal elect supply feeder, street light feeder, OH conductors / UG cables using elect tools, equipments and safety devices after arranging elect shut down of feeders from sub station to remove elect faults like tightening of loose connection, removing of any electric short,meggring of cable, excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightening of cable lugs etc all as required at site and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safety devices. (ii) Any major materials used for rectification of faults like Cables,MCB/ MCCB/ cable jointing kits/ cables of any type etc shall be measured and paid separately/ supplied by department.
S&F in repairs for informatory/ eqpt history sign boards of size not less than 900 x 600mm rectangular type with 2mm thick MS sheet plain type made out of angle iron channels frame, back ground and epqt history details (i.e. Name, Make, Ser No, Capacity of eqpt, Vintage, SM/ MES No etc.,) with high intensity retro reflective sheet letters as specified colours (blue and white) complete all as specified and directed.
Material and labour for cutting and cleaning all branches of trees on Street Light poles and maintaining the street Light fittings minimum 3 m all around tree braches at OTA area all as specified and directed. Note :- (i) Span shall be measured along the direction of Poles. (ii) The Item shall be operated 3 times in the entire period of the contract and the measurement shall be taken one time for payment after completion of third time.
Cutting unanxious green growth and wild grass by Machine at Electric / DG Set supply Installation premises, around pole, Two pole Structure, Four Pole Structure along the boundary, Fencing etc.,. Removing rubbish from the Site of work and depositing where directed not exec 100 metre from the starting point, complete all as specified and as directed.
S.M.ELECTRICALS
EVEREST ENGINEERING WORKS
Bidder Name
S.M.ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .