| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹365.7 CrAdmitted-Finance | ₹365.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹391.6 CrAdmitted-Finance | ₹391.6 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per PQ |
| Sl No | Description | Qty | Unit | SCON Projects Pvt ltd L2 | SATHLOKHAR SYNERGYS E&C GLOBAL LIMITED L1 |
|---|---|---|---|---|---|
| 1.00CIVIL AND STRUCTURAL WORKS | |||||
| 1.01EARTH WORKS: | |||||
| 1.02 | Clearing Light jungle including uprooting of trunk vegetation,grass,brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 36,625 | Sqm | 22.8 ₹9.9 L | 15 ₹6.5 L |
| 1.03 | Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the PMC/Employer and clearing and levelling the site, etc., complete complying with standard specification.The item shall include necessary civil works required for ensuring retention of full depth of excavation. | 13,483.92 | Cum | 218.4 ₹34.7 L | 154 ₹24.5 L |
| 1.04 | Up to 2.40m Depth | 2,696.74 | Cum | 258 ₹8.2 L | 154 ₹4.9 L |
| 1.05 | Up to 3.40m Depth | 6,741.86 | Cum | 321.6 ₹25.6 L | 252 ₹20.0 L |
| 1.06 | Up to 4.40m Depth | 4,477.3 | Cum | 406.8 ₹21.5 L | 333 ₹17.6 L |
| 1.07 | Up to 5.40m Depth | 850.46 | Cum | 492 ₹4.9 L | 572 ₹5.7 L |
| 1.08 | Up to 6.40m Depth | 510.27 | Cum | 568.8 ₹3.4 L | 648 ₹3.9 L |
| 1.09 | Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the PMC/Employer with an initial lead of 10 mts and initial lift of 2 mts. and including necessary backfilling in layers of not more than 15 cm thick well rammed, watered and consolidated, clearing and levelling the site, etc., complete complying with standard specification. | 4,274 | Cum | 297.6 ₹15.0 L | 344 ₹17.3 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹1.5 Cr
Closing Date
16 Feb 2026, 3:00 pmClosed
The Managing Director
TIDEL Park Ltd No.4, Rajiv Gandhi Salai, Taramani, Chennai 600113
Construction of IT Office Commercial Mixed Use Building Including Civil Construction Electrical HTLT HVAC Elevators IBMS FPS PHE Structural Facade Landscaping STP WTP and Other Allied Development Works at Hosur Krishnagiri TN
2026_TIDEC_643782_1
TIDEL/2025-26/21
Open Tender
Construction Works
730 days
Hosur, Krishnagiri District
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.5 Cr
TIDEL Park Chennai
20 Feb 2026
14 Jan 2026
17 Feb 2026
14 Jan 2026
16 Feb 2026
7 Feb 2026
14 Jan 2026 - 23 Jan 2026
23 Jan 2026
CIVIL AND STRUCTURAL WORKS
EARTH WORKS:
Clearing Light jungle including uprooting of trunk vegetation,grass,brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the PMC/Employer and clearing and levelling the site, etc., complete complying with standard specification.The item shall include necessary civil works required for ensuring retention of full depth of excavation.
Up to 2.40m Depth
Up to 3.40m Depth
Up to 4.40m Depth
Up to 5.40m Depth
Up to 6.40m Depth
Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the PMC/Employer with an initial lead of 10 mts and initial lift of 2 mts. and including necessary backfilling in layers of not more than 15 cm thick well rammed, watered and consolidated, clearing and levelling the site, etc., complete complying with standard specification.
Extra for every additional 1 metre lift or part thereof over the initial lift
All Kind of Soil - (From 2.00m to 3.00m depth)
All Kind of Soil - (From 3.00m to 4.00m depth)
All Kind of Soil - (From 4.00m to 5.00m depth)
All Kind of Soil - (From 5.00m to 6.00m depth)
Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the PMC/Employers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Disposal of surplus earth including loading, conveyance within a distance of 5 km or city limits (basic cost of earth is zero) and disposal of the conveyed earth.
Supplying and filling in foundation, basement, etc with filling suitable earth in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the PMC/Employer.This item shall include rate for all soil testing as specified in standard specification..
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of PMC/Employer 'With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of PMC/Employer.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of PMC/Employer
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of PMC/Employer.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of PMC/Employer, upto 90 metre depth below ground level.
400 mm dia
Supplying and filling of M- sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the PMC/Employer.This item shall include rate for all soil testing as specified in standard specification.
ANTI TERMITE TREATMENT :
Providing Pre-constructional Antitermite treatment including cost of chemical labour as per standard specification for preparing the area for treatment by spraying chemicals and other incidental charges etc., complete the rates should be for curing antitermite treatment from the plinth beam and brick masonry with super structure in contract with the back fill earth and at the junction of the walls. The top surfaces of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide 'Chloripyrifos' and spraying the same termicide soultion on the wooden frames and treating the other periphery of building etc., Complete in all respects as per IS 6316 (Part II) and as directed by the PMC/Employer.
CEMENT CONCRETE WORK :
To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.
Plain Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly inclusive of shoring, strutting, bailing out water, ramming, curing etc. complete in all respect by the PMC/Employer.
Plain Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly inclusive of shoring, strutting, bailing out water, ramming, curing etc. complete in all respect by the PMC/Employer.
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the PMC/Employer.
Plain Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation
Ground Floor
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation and Basement
Ground Floor
Providing and laying in position, Standardised Concrete Mix M-35 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation and Basement
Ground Floor
For First Floor
For Second Floor
For Third Floor
For Fourth Floor
For Fifth Floor
For Sixth Floor
For Seventh Floor
For Eighth Floor
For Nineth Floor
For Terrace Floor
Providing and laying in position, Standardised Concrete Mix M-50 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 460 kg/m3 and maximum water cement ratio of 0.35, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.7+B879 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation and Basement
Ground Floor
For First Floor
For Second Floor
For Third Floor
For Fourth Floor
For Fifth Floor
For Sixth Floor
For Seventh Floor
For Eighth Floor
For Nineth Floor
For Terrace Floor
FORM WORK :
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Main Building
Other Building
Providing Form work and centering for reinforced cement concrete works including supports and strutting up to 3.30m height for plane surfaces as detailed below with all cross bracings using mild steel sheets of size 90cmx60cm and MS 10 gauge stiffened with welded mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak or country wood joists of size 10cmx6.5cm spaced at about 90cm centre to centre supported by caurina props 10cm to 13cm dia spaced at 75cm intervals and removing the same after a specified period without damaging the RCC works etc., complete complying with standard specifications and as directed by the PMC/Employer.
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Centering for curved surfaces of all RCC items of work
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.30 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc.,complete complying with standard specification and as directed by the PMC/Employer.
REINFORCEMENT STEEL :
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire of 18G in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Applying one coat of anticorrosive treatment on steel reinforcement rods (20 ltrs. Of anitcorrosive chemical for one mertic tonne of steel reinforcement rods) at site including a cost of required quantity of anticorrosive chemicals, (best approved quality) cement, consumables such as brushes, gloves and labour for anticorrosive coating etc. complete and as directed by the PMC/Employer. (The Quantity and brand of anticorrosive chemaical should be got approved by the PMC/Employer
WATER PROOFING :
Note: All the waterproofing treatment shall be executed through a specialized waterproofing agency authorised by the approved manufacturer and/or PMC/Employer. Contractor shall submit technical data sheet of each product, which shall use for execution.
A written guarantee on non-judicial stamp paper shall be submitted by the main Contractor and his sub contractor who has carried out work for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system.
water proofing works shall be executed under supervision of technical person of manufacturer. Contractor shall test all elements before and after water proofing treatment as directed by PMC/Employer. Rate shall include for testing process before and after waterproofing treatment. The rate includes giving 10 year warranty for waterproofing on a Rs.100/- stamp paper in approved proforma.
NOTES: 1.Ponding test shall carried out on the mother slab 2. Rectification shall be carried out in case of leakages like crack treatment, grouting etc. to arrest the leakage. 3. Ponding test shall be carried out once again to check for leakages. 4. Once there are no leakages, waterproofing treatment shall be carried out, else the procedure shall be repeated. 5. Payment will be only once for the water proofing 6.The cost should include treatment of cove (wata) at the interface of floor and parapet /pedestals, sealing the annular space between the pipe and the masonry, making khurras, river sand screened and washed, at all leads, lifts, heights, scaffolding, with proper slope to drain-off water entirely, complete, etc.
Terrace Waterproofing
Finishing the top of Terrace floor with one course of solar reflective water proof, heat proof and cool roof ceramic tiles of size 300mmx300mmx8mm thick of approved quality laid in cement mortor 1:3 (one part of cement and three parts of sand) over base concrete mixed with calcium based mineral powder (60 kg for 1000 sqft) (before laying tiles, the tiles should be dipped with salin based nano liquid) and top Grouting with cement mortar 1:3 (one part of cement and three parts of sand) mixed with white cement, silicon powder and polimer additives (20kg m 1000 sqft.) and joint pointed with zycosil oil (200gm for 1000 sqft.) after grouting acrylic salin based liquid including cost of base concrete 1:2:4 mix using 6-10mm chips 40mm thick etc., complete complying with standard specifications including cost of all materials, labour charges for lifting to open terrace, laying and finishing and other incidental charges etc., complete and as directed by the PMC/Employers. (The Brand and quality of tiles should be got approved from the PMC/Employer before using).
Grading For Terrace Floor with 1:2:4: Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the Project Officer.
Terrace Water-proofing with Insulation
Providing and applying waterproofing and insulation for terrace in two parts as per the specifications listed below and as approved by the PMC/Employer with a guarantee of 15 years: inclusive of chasing open the construction joints and sealing the same to form a U shaped groove of approx. 20mm width and 20mm depth, using polymer modified mortar carrying out injection grouting at the construction joints, honeycombs, etc, by injecting cement slurry grout admixed with expandable grout additive to full saturation wherever necessary thereafter. (ONLY PLAN AREA CONSIDERED FOR MEASUREMENTS)
Polyurethane Based Waterproof coating system
Providing and applying Liquid applied single component pitch free Polyurethane coating capable of bridging substrate cracks upto 2mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Plasticised expandive grout admixture, application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet Non-shrink cementitious grout application primer water dispersible epoxy primer @ 8- 10 SQM/ Litre and allow it to become tackfree and application of two coats of Polyurethane coating @ consumption of 2.2 kg/m2 in 2 coats to form DFT of 1.5mm (without priming / scratch coat conforming to ASTM C 898). complete including all tools and tackles as per manufacturer’s specification. Termination details - The coating shall be taken over the parapet well and shall be terminated by providing groove min 300mm down on the other side of the parapet wall Minimum Properties required for PU Membrane Elongation as per ASTM D 412 Tensile strength as per ASTM D 412) Puncture Resistance as per ASTM E 154 Water Head Resistance: as per BS-EN-12390-8 / DIN 1048) Adhesion to concrete: Bond Strength as per ASTM D 4541 Crack bridging capacity as per ASTM C 1305 Shore A Hardness as per ASTM D 2240): >75
Non woven polyester Geo Textile fabric
Providing and placing Non woven polyester Geo Textile fabric (minimum 300 gsm) having Grab Tensile Strength > 650N ASTM D 4632, Puncture Strength (CBR) > 1600 N ASTM D 6241, UV Resistance @ 150 hrs > 85% (% Strength Retained) ASTM D 4355, with minimum 75mm overlap on the ends and sides as a separation layer on top of waterproofing
PUF Insulation Spray
Providing and applying Two Component Polyurethane based, HFC Blown, CFC & HCFC closed cell type sprayale rigid foam overdeck insulation system in average 40mm thickness. Surface prepartion includes cleaning of concrete surface to remove dust,dirt etc., followed by application of heated volumetric proportioning machine at 1:1 volumetric output fitted with spray gun, such as those manufactured by Graco or equivalent compressor enabled spray machine, followed by applying 2 coats of polyurea-polyurethane waterproofing cum sealer coat over PUF layer @ 1.5mm DFT. product shall be having properties viz. Gel time of 13 secs, Closed cell content 96 % as per ISO 4590, density of foam being >45 kg/m3 as per ASTM D 1622, Thermal Conductivity at 25 °C = 0.023 W/mK, Compressive strength Min > 400 Kpa as per ASTM D-1621/94, Water absorption Min < 3% as per EN12087, Fire resistance conforming to Class - B2 as per DIN 4102, Tensile Strength Min > 500 Kpa as per ASTM D1623/78, Adhesion to substrate- >180 Kpa ASTM D4541,Water Vapour Transmission, EN12086-132 perms, Specific Gravity of Part A & Part B - 1.23 at 20°C etc, complete. All the honeycombed areas shall be identified and injected with cement slurry admixed with AM. Check for moisture, it shall be below 5%, etc, complete. Thickness may varies as per site and client requirement as per U Value. (Primer Coat)
Non woven polyester Geo Textile fabric
WET AREA WATER PROOFING
Providing Polymer Coating (Water Proof Coating) for sunken portion of wet areas with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the PMC/Employer etc. The rate inclusive of cost of materials and labour, etc., complete.
Light weight Sunken filling using broken brick jelly 20 mm gauge The proportion of broken brick jelly of ratio being 1:3:6 (1part cement,3 part fine aggregate & 6 part broken brick jelly), well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by PMC/Employer.
UGT/OHT (inside) waterproofing with Anti microbial Coating
Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two B139component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification
Retaining wall/ UG tank wall (outside) Waterproofing with SBS Membrane
Providing and laying water proofing treatment to the Retaining wall, water retaining structures outside with fully bonded 1.6mm Thick SBS modified self-adhesive, cross laminated HDPE lining waterproofing membrane, conforming to IS 16471:2017 Type A, requirements of UG waterproofing structures, The SBS membrane shall have Mass per Unit Area > 1.8 Kg/m2 as per ASTM D 5147, Puncture resistance > 200 N as per ASTM E 154, Elongation > 180% as per ASTM D 412-06, Tensile Strength > 4 Mpa as per ASTM D 412- 06, Tear resistance > 20 N/mm as per ASTM D 4073, Hydrostatic pressure > 50M as per DIN 1048. The lap with HDPE membrane shall be 100mm treated with TS tape. followed by the installation of 8-10mm THK polyethylene dimpled drain board having compressive strength > 400kN/m2 (as per ISO 25619-2). The finished cost includes surface preparation, making coving and a coat of solvent based bituminous primer @ 0.25l/m2 on entire surface before laying membrane completely as per specification.
Underground structures waterproofing with HDPE membrane
Providing and laying water proofing treatment below UG tank raft over PCC, Lift pits, with fully bonded 1.5 mm thick HDPE waterproofing pressure sensitive adhesive membrane over PCC before laying raft concrete having higher puncture resistance of 1000N as per ASTM E 154, confirming to BS 8102 & IS 16471:2017, requirements of UG waterproofing structures. Laying adjacent sheets by keeping overlap of 75mm, end overlaps to be treated using double sided tape. The membrane shall have Tensile strength >25 Mpa as per ASTM D 412, Elongation > 500% as per ASTM D 412, Hydrostatic head resistance >70m head of water as per ASTM D 5385, Low Temperature Flexibility: -25 deg C, Peel Adhesion to Concrete >880 N/m as per ASTM D 903 Modified, UV Exposure > 45 Days. The finished cost including surface preparation completely as per specification.
Newly Constructed Roof/balcony/Refugee area with Cementatius Waterproof coating below 500 Sq.m
Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.
Providing and fixing heat resistance terrace tiles(300mmx300mmx10mm)with SRI (Solar refractive index)>78,solar refelction >0.70 and initial emitance >0.75 on waterproof and slopped surface of terrace, laid on 20mm thick cement, sand, mortar in ratio of 1:4(1 Cement : 4 course sand) and grouting joints with mix of white cement and marble powder in ratio of 1:1,including rubbing and polishing of surface upto 3 cuts complete,including providing skirting upto 150mm height along parapet wall in the same manner.
STRUCTURAL STEEL WORKS
Note for items of this Section : Contractor shall prepare shop drawing based on intent/ concept drawing and submit the same to PMC/Employer for approval and shall get approval before mock up/ execution of work. Work shall be carried out as per final approved shop drawing and approved mock up. Contractor shall responsible against stability, safety, leakage, etc all complete. Testing work shall be carried out by the Contractor as suggested by PMC/Employer.
Supply, Fabrication, Erection, alignment and levels as per approved shop drawing of structural steel work in built up sections comprising of ISMB, ISMC, angle, plates and round bar section etc., for column, truss,MS Door in Gas Bank, Stream Generator Room. Necessary permanent rivets, bolts, washers and nuts, handling, straightening, cutting, drilling holes, welding, shop assembly, transport to erection site, storing, leading to erection site and apply one coat of anti corrosive yellow primer paint and 2 coat of approved colour paint of approved make prior to erection. (payment to be made on the basis of standard section weights for net weight erected in position excluding permanent/temporary bolts, rivets etc., Rate should include the cost of permanent bolts, nuts, and washers packing plates as required and approved. And no seperate measurement shall be taken for payment of permanent bolts, nuts, all types of washers and packing plates etc..)
Supplying, cutting to shape, securing to the supporting members with bolts or welding as shown on drawings, 6mm thk M.S. Chequered plate . The rate shall be for the actually placed plate.
Providing, fabricating and fixing M.S. grills work for windows, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by thePMC/Employer
MISCELLANEOUS WORK
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete
Supplying and grouting of pockets inside the concrete structures using non shrink compensated cementitious grout including making arrangements to fix the MS framework , MS bolts , inserts, etc to required line ,level and position & cleaning the pockets & surface using water to make it free from dirt and dust ,pouring the ready mixed grout in the locations as per manufacturers detail specifications including curing at all levels and locations etc., complete all as directed
Cutting, bending and placing in position reinforcement bars of required diameter and confirming to IS 1786 wherever required by means of welding and anchorage in the wall/beams with approved Chemical bonding compound lockset after proper drilling holes in walls/beams by machine drill as per requirements with existing reinforcement.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of PMC/Employer
Made of G.I. wire of dia 4 mm
Providing corrugated galvalume sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.5mm thick
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
75mm thick
100mm Thick
150mm Thick
200mm Thick
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of PMC/Employer.
200mm Dia
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, reinforced with 8 mm dia four Nos longitudinal & 9 Nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of PMC/Employer.
75mm thick
100mm Thick
150mm Thick
Providing and fixing of Precast Concrete U Drain of Grade - M25 conforming to relevant I. S. and CPHEEO Specification ( including nominal reinforcement if required as per design consideration) the cost including with necessary earth work excavation, backfilling and compaction etc, complete.
400mm width
500mm width
Size-500x500x600mm
Hole Packing treatment on service line Providing and applying total packing treatment on any type of pipes comes into water proofing area as follows: Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of polymer coating using Polymer bonding agent to enhance adhesion between the packing material and other surfaces.
Providing laying and fixing of following dia RCC Hume Pipe NP2 Class - IS 458/2003 in ground complete with RCC Collers, jointing with cement mortar 1:2 as PMC/Employer.
200mm Dia RCC hume pipe
300mm Dia RCC hume pipe
ARCHITECTURAL & FINISHES WORKS
Masonry works
Note : 1. "Procurement of items with astehetic value and visibility shall be on prior approval of Architect and PMC/Employer for specific arae of application."
Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For Foundation and Basement.
For Ground Floor
For First floor
For second floor
For third Floor
For fourth Floor
For Fifth Floor
For Sixth Floor
For Seventh Floor
For Eighth Floor
For Nineth Floor
For Terrace Floor
Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For Foundation and Basement.
For Ground Floor
For First floor
For second floor
For third Floor
For fourth Floor
For Fifth Floor
For Sixth Floor
For Seventh Floor
For Eighth Floor
For Nineth Floor
Masonry work using Autoclaved Aerated cement blocks of size 600 x 200x 200 mm in Self curing AAC in cement Motar (1:6) (one of cement and six of M Sand) along the boundaries using AAC Block 600x 200x 200mm)minimum average crushing strength of 50Kg/sqcm in all floors including labour for fixing the doors , windows and ventilator frames in position fixing of hold fast , scaffolding ,curing etc complete in all respects complying with relevant standard specifications and drawings and as directed by the PMC/Employer. ( AAC Block should get approved by the PMC/Employer before execution of work)
For Ground Floor
For First floor
For second floor
For third Floor
For fourth Floor
For Fifth to Terrace Floor
Masonry work using Autoclaved Aerated cement blocks of size 600 x 200x150 mm in Self curing AAC in cement Motar (1:6) (one of cement and six of M Sand) along the boundaries using AAC Block 600x 200x 150mm)minimum average crushing strength of 50Kg/sqcm in all floors including labour for fixing the doors , windows and ventilator frames in position fixing of hold fast , scaffolding ,curing etc complete in all respects complying with relevant standard specifications and drawings and as directed by the PMC/Employer. ( AAC Block should get approved by the PMC/Employer before execution of work)
For Ground Floor
For First floor
For second floor
For third Floor
For fourth Floor
For Fifth to Terrace Floor
Wall Preparation
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 15mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 15mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., in all floors including necesary band, drip moulds, curing etc., complete complying with standard specification and as directed by the PMC/Employer.
Plastering External with Cement Mortar 1:5 (One cement and Five Plastering sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thickincluding rtar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Providing and applying 12 mm thick ( average ) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite / perlite respectively conforming to IS:2547 ( Part -1 & II ) 1976, applied on hacked/ uneven background such as bare brick/ block/ RCC work on wall & ceiling at all floors and locations, finished in smooth line and level etc. complete.
for buildingS
Providing and applying Bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of PMC/Employer complete in all respect. SBR Polymer ( @10% of cement weight ) modified cementitious bond coat @2.2kg cement per sqm of surface area mixed with specified proportion of approved polymer.
for buildingS
for staircase area
FLOORING, DADO & SKIRTING
Note: Contractor shall submit flooring mockup as per the drawings and get approved by PMC/Employer before execution of work.
Paving the floor with best quality Anti skid Vitrified Tiles Flooring of size 600 x 600 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by PMC/Employer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10mm thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm
Providing and laying Double Charged Anti Skid Vitrified Tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 100mm high Anti Skid Vitrified Skirting
Providing and Filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the PMC/Employer. The rate inclusive of cost of materials and labour, etc. complete.
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties
Paving the floor with best approved quality fine polished Granite Stone Slabs of 18 / 20mm thick for extra Inlay in Granite@ 15% added
Granite wet cladding on walls/columns/cills/facias/ jambs/soffits /Bands/ skirting ;Providing and fixing Granite Stone machine cut and machine high prepolished best quality approved colour granite slab of thickness not less than 17/18mm for wall lining (veneer work)/ dado of approximate size 1200 x 600 / 900 x 600 mm, backing filled with a grout of average 18 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) set in laticrete adhesive L290 or equivalent, including pointing with matching colour of Laticrete or Araldite Joint filler or approved equivalent to match the granite shade including rubbing, curing and polishing including chamfering and edge polishing at exposed surfaces etc. all complete as specified and as directed by the Engineer-in-Charge all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. The cost to include all shuttering, scaffolding, props. Also it has to be ensured that the bedding mortar thickness is adjusted to achieve the desired level to flush the surfaces with adjoining finishes.
Fine Polished Granite Slab 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties
Paving the floor with best approved quality Flamed finish Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of approved colour with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and finishing joint with Laticrete or Araldite joint filler or approved equivalent joint filler of approved shade etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with best approved quality Flamed finish Granite Stone Slabs of size 1200 x 600 of 40mm thick of approved colour with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and finishing joint with Laticrete or Araldite joint filler or approved equivalent joint filler of approved shade etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
600x600mm & 10mm thk. (Double charged)
Providing and laying Double Charged Vitrified Tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm & 10mm thk (Double charged)
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Supplying and laying wooden flooring at site 8mm thick of approved make using click laminated floor with inbuilt 3mm sound bloc class of use 31 water resistant AC 3 grade impact resistant IC3 (as per EN 130 900 / 1400) having 0.60mm MLC (Multi-Layer Guard + SRSG 2) (Scratch Resistant Surface Second Generation) on top of moisture high density fibre board substrate specially developed copr of plank size 1288 x 196 x 8mm having joints tongue and groove to secure long lasting joint. The tongue and groove having the edges duly pre impregnated with par affine including laying 0.20mm thick alkali resistant polyethylene sheet of density 850 kg / m3 beneath the laminated wooden panel to absorb the sound caused including labour charges, loading, unloading, transportation, etc., complete
Rubber mat Flooring
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the PMC/Employer concerned before use on work, etc., complete as per standard speicification.
Flooring
Staircase Treads 300mm wide
Staircase Landing, Midlanding Area
Extra for pre finished nosing in tread of stpes of kota stone / Sand stone slab
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the PMC/Employer concerned before use on work, etc., complete as per standard speicification.
Skirting of 100mm high
Staircase Risers 150mm high
Staircase Skirting of 100mm high
Providing and fixing Acoustic Wall Panelling in channelled wood works perforated panels of width 192mm, thickness of 15mm and length of 2400mm or as per required by the Departmental Engineer made of a high density fibre board with minimum 725 kg./m3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special peforation pattern where the visible surface has a Helmholtz fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be tongue-and-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non woven acoustical fleese having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Engineer-in-Charge. Installation: Install aluminium box section (provided by others) of section 50mm x 25mm or as approved by the Engineer-in-Charge on the solid wall horizontally using screws and plugs at spacing of 600mm centre to centre. Screw the aluminium extruded keel for channelled wood works provided over the lowest and second aluminium section at an on centre distance of 600mm. Place the inside clip on the groove end of the panel along the aluminium keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour . Installation to be carried out by Trained Installation Team and installation should be carried out as per Recommended Procedure.
WPC Wall Panelling
Veneer Wall Panelling
Lacquered Glass panelling
Providing and fixing machine cut, mirror/ eggshell polished ,Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
Natural Stone - wall Cladding Fabrication, Supply, Installation and Handover of 3+mm thick Sintered stone cladding with embedded mesh including all necessary framework. The Sintered Porcelain slabs shall be Supported on Aluminium tube 50X25X1.8mm thick Framing. Our aluminium framing grid size is 500mmX500mm with structural silicone (DC795/995) use to stick the Sintered porcelain slabs to aluminium framework and continuous 3mm VHB tape (12mm width and 3mm thick.) is used for instant adhesion of the Sintered porcelain slab on aluminium frame. Groove 4mmm between the Sintered porcelain slab andthese grooves are sealed with weather sealant. The Aluminium frame System shall hold by aluminium angle brackets 50X50X4MM thick every 1 meter c/c with M8X75 SS fasteners for bracket support, SS 304 M8X19 screw used for aluminium framing complete with all other necessary accessories complete complying with standard specification and as directed by the departmental officers.
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished machine cut for kitchen platforms, vanity counter, window sills, facias ans similar locations for required size, approved shade, colour and texure laid over 20mm thick base cement mortar 1:4 ( 1 Cement : 4 coarse sand), joints treated with white cement , mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glass finish etc. complete at all levels.
Granite Lift Jamb
Providing Granolithic Floor finish of the 40mm thickness with plain cement concrete 1:2:4 ( one cement, 2 Crushed Stone sand and four aggregate ) using 10 to 12 mm Gauage hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc complete complying with standard specification and as directed by the PMC/Employer. ( the rate is inclusive of necessary planking for panelling wherever necessary and as directed by the PMC/Employer )
Counters
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished machine cut for kitchen platforms, vanity counter, window sills, facias ans similar locations for required size, approved shade, colour and texure laid over 20mm thick base cement mortar 1:4 ( 1 Cement : 4 coarse sand), joints treated with white cement , mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high glass finish etc. complete at all levels. ( rcc base for counter is to be provided )
Extra for fixing Marble/ Granite stone, over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin based adhesive, including cleaning etc, complete.
Extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, inclduing necessary holes for pillar taps, etc incldung moulding, rubbing and polishing of cut edges, etc complete.
PAINTING WORKS
Supplying and painting the walls with two coats of wall putty as instructed by the PMC/Employer including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the PMC/Employer before use of work).
White washing one coat with freshly burnt white shell lime in all floors including cost of lime, blue powder, fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the PMC/Employer.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the PMC/Employer before use on works.)
Finishing walls with textured exterior paint of required shade: New work( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
DOORS AND WINDOWS
2Hr Unisulated Metal Fire Rated Doors with Frame Providing and fixing of Medium Duty Hollow metal fire door at all levels approved Manufacturer, Single / Double leaf, as per IS 3614: 2021, for 120 min integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Test Cetificates to be submited along with the shop drgs for approvals. Door frame shall be single rebate grooved profile of size 125 x 55mm / 143mm x 57mm / 100mm x 57mm made out of 1.20mm (18 gauge) or 1.00mm (20 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners of HILTI / equivalent make 3 Nos of anchor fastners 10mm x 160mm with split end on either side and 2 Nos on top for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Steel door shutter shall be 46mm / 50mm thick fully flush double skin step design door, unsulated. Door leaf shall be manufactured from 1.2mm (18 guage) or 1.6mm (16 guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.
Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include for supply and fix 3mm thick base plates, all joints of frames with provision for anchor bolt fixing to wall / RC surface, reinforcement pad for fixing of door closers, factory finish, pre-punched cut outs to receive hardwares and iron Mongery, 3mm thick hinge plates predrilled to receive hinges for screw mounted fixing, stainless steel CE marked ball bearing hinges, handles, locks, door closer, panic bar, concealled drop down seal, flush bolt, intumisent seal to shutter etc all complete of approved make Rate shall also include for grouting the frame with cement slurry between wall and frame to the required thickness as per manufacturer’s specifications. Rate to inclusive of factory fitted all required SS hardwares but supply of all required SS hardwares shall be paid separately. Rate to include factory fitted concealled drop down seal & intumisent seal to shutter and frame of approved make as per manufactures specfications.
FD2 (Single Leaf -Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1200mm x 2400mm
FD1 (Double Leaf-Openable Door) with metal Door shutter with vision panel of size 150mmx 750mm Size: 1800mm x 2400mm
2Hr Uninsulated Metal Fire Rated Doors with single rebate Door Frame Supply and Installation of Medium Duty Hollow Metal Fire Door at all levels of approved manufacturer, Single / Double leaf, as per IS 3614: 2021, for 120 min integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Test Cetificates to be submited along with the shop drgs for approvals. Door frame shall be single rebate grooved profile of size 125 x 55mm / 143mm x 57mm / 100mm x 57mm made out of 1.20mm (18 gauge) or 1.00mm (20 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners of HILTI / equivalent make 3 Nos of anchor fastners 10mm x 160mm with split end on either side and 2 Nos on top for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Steel door shutter shall be 46mm / 50mm thick fully flush double skin step design door, unsulated. Door leaf shall be manufactured from 1.2mm (18 guage) or 1.6mm (16 guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.
Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include for supply and fix 3mm thick base plates, all joints of frames with provision for anchor bolt fixing to wall / RC surface, reinforcement pad for fixing of door closers, factory finish, pre-punched cut outs to receive hardwares and iron Mongery, 3mm thick hinge plates predrilled to receive hinges for screw mounted fixing, stainless steel CE marked ball bearing hinges, handles, locks, flush bolt, intumisent seal to shutter etc. all complete of approved make & as per detail drgs. Rate shall also include for grouting the frame with PU foam between wall and frame to the required thickness as per manufacturer’s specifications. Rate to inclusive of factory fitted all required SS hardwares but supply of all required SS hardwares shall be paid separately. Rate to include factory fitted intumisent seal to shutter and frame of approved make as per manufactures specfications.
SD1 (Single Leaf-Openable Door) Size: 750mm x 1500mm
SD2 (Single Leaf-Openable Door) Size:750mm x 1200mm
SD3 (Single Leaf-Openable Door) Size: 500mm x 600mm
SD4 (Single Leaf-Openable Door) Size: 900mm x 1800mm
Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. Door Shutter Type : Flush shutter Thickness:35mm
Providing and fixing in position seasoned C.P. Teak Wood Frames of section (Approx 65mm x 150mm) as approved by Architect for doors including double grooves on both sides and two rebates for shutters /grills, shaping, jointing, sand papering, applying a coat of bituminous paint on concealed surface, necessary fixing in masonry / RCC by means of HILTI / Equivalent make Anchor fastener, 3 Nos. on each side. Frames to finished with three coats of approved PU polish finishing etc. all material and labour complete.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
Double Leaf/ Single Leaf Door
Providing and fixing approved make and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved make & manufacture SS 304 grade D type 600mm pull handle & stopper ISI marked with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specification & as directed by Engineer-in-charge.
UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Rate also to be inclusive of GI Box section of size 150mm x 120mm for Access Control Panel fixing, Box section shall be finished same as per the partition frame.
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc
ROLLING GRILLS (WITH ISI MONOGRAM) Gear Operated Type (from 8 sqm. to 12 sqm. Area)
Designing, Printing, Supply and Fixing of Frost film to glass partitions using 3M frosted film stickers as per required pattern and shape and as directed. Cost inclusive of designing, mockup and installation with all accessories. The vendor must submit required warranty certificates from the manufacturer. Working at all levels and heights and as directed by the departmental officers. The Frost Flim should be got approved from the Executive Engineer before use on work.
RAILING
Steel work Welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required - in grating, frames, guard bar, ladder, railings, brackets, gates & similar works ( for Railing works )
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and appling a priming coat of approved steel primer all complete.
Design, supply and installation of frameless glass railing system for a height of 1200mm from finished floor. The glass panel shall be of 12mm thick clear toughened glass connected to slab/beam by means of 304 grade stainless steel U-Channel at bottom with non staining weather sealant of approved make. On top, glass shall be held together by stainless steel round top U- channel of 25.4mm dia., all complete to perform as per approved detail drawings. The complete system to be designed to accommodate thermal expansion. The joint between glass panels & gaps at the perimeter & U – channel of the assembly to be filled with non-staining weather sealant, so as to make the entire system fully waterproof and dust proof. Setting block to be inserted inside U-channel at bottom for proper alignment of glass. The rate shall include all design, engineering & shop drawings including approval from structural design, labour, T&P, other incidental charges, SS Channel, laminated glass etc. All complete. Refuge Areas - 7th & 9th Floors
Fencing with angel iron post placed at required distance embedded in cement concret blocks, every 15th post, last but one end post and corner post hall be strutted on both sides and ed post on one side only and provided with horizontal lines and two diagonal interwoven with horizontal wires, of barbed wire weighin g 9.38 kg per 100m ( miniumum ) between the two post fitted and fixed with GI staples, tum buckles etc complete ( cost of post, struts. earth work and cocrete work to be paid for separately) . Payment to be made per metere cost of tatoal length of barbed wire used .
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia. Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
FALSE CEILING
Note : Contractor shall take approval of the mock up from PMC/Employer before execution of work.
Gypsum Ceiling
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Extra for Providing and fixing Gypsum Hanging Panels etc. as per approvel design
MR Gypsum board with grid ceiling
Gypsum Fluting Effect Ceiling
Acoustic Gypsum Board with grid tile ceiling- Saint Gobain Ecophon circle in size 1200/800 mm dia X 40 mm thickness, Tiles are demountable, Panel is manufactured from high density glass wool with acoustical painted surface on both the sides. Edges are straight cut & painted. Acoustics-Sound absorption(Sabine) - 2.05 at 1000 mm ods as per EN ISO 354 Humidity Resistance -Permanent ambient RH upto 95% at 30 * C without sagging , warping or delaminating (EN 13964:2014). Fire Safety -Tested and classified as non combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 -1 -European Standard. Light Reflectance - 85% light reflectance Indoor Health & Well-being - Complying with the French regulation on VOC emissions, A+ level.Certified by the Finnish Building Information Group (RTS) with the M1 label. Free from Substances of Very High Concern (SVHC) above 100 ppm as defined by the European REACH regulation (No1907/2006). Product Certified under GRIHA Council of India for Green ratings. Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards. Circularity - Re-cycled content of more than 70% CE marking - CE-marked according to the harmonised standard EN 13964:2014 Maintenance - Daily dusting & vacuum cleaning, weekly wet cleaning.
Saint-Gobain Ecophon Solo™ Baffle is vertically installed unframed baffles. Solo Baffle can be used to form distinct lines and is available in different sizes and a wide range of colours. Size 1200X200X40mm, 1200X300X40mm Manufacturing- Manufactured in Sweden, production unit is ISO 14001 certified. Acoustics-Sound absorption(Alpha w) - 0.65 at 600 mm o.d.s at c600 Flexural tensile strength - Class C/Pass Indoor Air quality - Complying with the French regulation on VOC emissions, A level. Certified by the Finnish Building Information Group (RTS) with the M1 label.Certified by Eurofins Indoor Air comfort® . Product Certified under GRIHA council of India for Green Ratings,IGBC Green Pro certified, Comply with the REACH regulation of the European chemical Agency, certified by the EUCEB which confirms that mineral wool is produced in conformity with the Note Q of EC No 1272/2008 and therefore classification as a carcinogen does not apply Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards, HPD certified Circularity - Minimum post-consumer recycled content 57%, Fully recyclable Fire Safety-Tested and classified as non combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 -1 -European Standard.
Providing and constructing 75mm thick Dry Wall Partitions, consisting of the following specifications: Providing & fixing of 48mm C Stud {Material-ASTM A-792-2010, Y/S-310Mpa, Finish - AZ150} 0.5mm thick having unequal flanges of 34mm & 36mm, length 3660mm, placed at 610mm centre to centre in 50 x 0.50mm floor and ceiling channel {Material - ASTM A-792-2010, Y/S-310Mpa, Finish - AZ 150} (0.50mm thick having equal flanges of 32mm made of Steel, length 3660mm), which is anchored to the floor & Soffit/true ceiling using anchor fastener Ø8x40mm Hilti make at 600mm c/c in zigzag manner. Fiixng channel 99 x 9 x 0.90mm {Material-IS277,120GSM galvanizing coating both sides inclusive} has to be provided at every horizontal joint of the outer layer boards & fixed to the studs using Ø4x13 Wafer head Metal to Metal screws. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A nogging channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ 150 (IS 15961)} of 48 x 0.5mm width has to be provided at the horizontal joints of the two boards. Providing and fixing Final Skin of Partition, which include of tapered edge 12.5mm thick Regular Gypsum board on both sides. Boards to be screw fixed with drywall screws of 25mm at minimum spacing of 600mm at centre and 600mm at periphery. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound, (Conforms to ASTM C475), Joint Paper tape or fiber tape. The junction of the partition with masonry & all penetration through the partition has to be treated with Hilti / Pyroplex fire and acoustic sealant. The boards are to be fixed vertically to the framework with joints staggered to avoid leakage through joints. 25mm x 25mm x 0.5mm angle bead should be used at all L-Junctions of partition. Screw fix angle bead at the external corner of drywall and shadow line edge bead at the junction of drywall & column has to be used to get straight line and finish and protection from impacts. Edge bead has to be used to protect the exposed edges of Gypboard. Shadow line beads to be used at the junction of door jambs, glazing, windows etc for giving a clean, straight, shadow edge on installation and finishing.
2Hr Fire Rated Glass Partition Supply and Installation of Shakti Hormann insulated glazed Fire Fixed Partition as per IS 16947 for stability, integrity (E/EW 120) & Insulation (EI 30). Pressed galvanized steel confirming to IS 277 with the following specification. Glazed partition shall be tested to IS/ISO 834-1, IS/ISO 3008-1 for integrity & insulation (E/EW 120). Glazed partition shall be tested from CBRI/ TBW / CERTIFIER for maximum rating of 120mins with 30Mins Insulation. Test certificates should be made available for max door size tested as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Partitions The system is tested as per reputed laboratory. The profiles are manufactured from 2.0 mm galvanized steel sheet pressed formed to a profile of the dimension of 60 x 70 (overall dimension in mm) as by means of M10 x 120 or bigger steel bolts at every 300mm from the edges and every 550 mm (approx) c/c. The glass should be held in its place with the help of minimum 1.25 mm GI beading which can be clamped or bolted to the profile by 4 mm x 35 mm steel screws at every 250 m c/c and a ceramic tape of the cross section of 5 mm x 20 mm as per the test evidence. A 2 mm ceramic paper should be put all around the perimeter of the glass. The glass panes are to be supported on non-combustible 5 mm Calcium Silicate setting blocks. The maximum glazing size cannot be more than 1250mm x 2840mm (w x h) or 3.55 sq. mt in total area as per the test certification.
with Contraflam Lite 14mm clear 120min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 20) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall provide bi-directional (Symmetrical) fire protection. Rate to be inlcusive of necessary MS framework above the Partition to support the Partition as per manufactures specifications. MS shall be finished with approved paint with anti rust primer. Rate also to be inclusive of GI Box section of size 150mm x 120mm for Access Control Panel fixing, Box section shall be finished same as per the partition frame. 12 mm thick toughened glass Partition
Toilet Cubical- Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 304) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. All screws will be of 304 Grade in stainless steel with satin finish. All pilasters are supported by series stainless steel shoe box with MS- Base Plate. The Base of stainless steel shoe box will be anchored to the floor with a clearance height upto 110 mm. Fixing of intermediate panels to the wall shall be stainless steel 'L'- Bracket or stainless U- Channel section are fixed into wall with screw inserts. All screws will be of 304 Grade in Stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 110 mm. All intermidiate panels shall be 12 mm thick, pilasters and door shall be 18 mm thick with edges chamfered complete as per drawing and directions of Engineer- In- Charge.
Toilet Cubicle with standard dimension of 1840 mm Height x 1000 mm width x 1550 mm Depth, which include 600 mm door size width). Toilet Cubicle I- Shape (Front Partion) with standard dimension of 1840 mm Height x 1000 mm width which includes 600 mm door size width).
Providing and fixing Protection Gate
Manufacture, Supply, fabrication and Installation of Motorized Sliding Compound wall Gate as per detail drgs Number of leaves: as per design Mounting surface: as per design Bottom Rail : RCC Columns : RCC / M.S. Gate Design Pattern :Standard Mild Steel square hollow tubular section, torsion free fully welded unit Gate frame:M.S. pipe top/bottom horizontal & vertical profile Infill's : The infill's are to be fully welded between the upper & lower gate frame Cladding : (Optional if any applicable as per gate design) Bottom rail : C channel & 20mm round polished bar Bottom rollers: Italian make Galvanised Wheels 120mm dia.with ball bearings and axle with lubrication point (Appx. weight will be 80kg per Sqm )
Gate 01-Main entry-Two panels Telescopic sliding(equal divisions) - Automatic
Gate 02-Main exit-Two panels Telescopic sliding(equal divisions)
Manufacture, Supply, fabrication and Installation of Swing Type Openable Compound Wall Main gates and wicket gates of specified size and width constructed in MS frames as per design and detailed drawings including all accessories and hardwares and all fabricated and fixed as shown in the drawing, including buffing, painting 3 coats with approved shade epoxy paint over a coat of Zinc chromate primer / Anti corrosive painting etc. complete and all as directed. Rate shall include for fixing in position, alignment, grouting the MS support using cement concrete 1:2:4 and finishing the surface neat and smooth etc. as per drawing and specification complete as directed. Gate should get manufactured in factory & after inspection get dispatched to site except final coat of painting which will be done at site after installation (Appx. weight will be 80kg per Sqm )
Gate 04-OSR--Single panel Non-Telescopic sliding
Gate 08-Service - pedestrian entry-Single panel swing
Gate 05-HSD yard-Single panel Non-Telescopic sliding
UGT/STP
FAÇADE WORKS
Note for items of this Section: Designing, providing, fabricating, testing, protection, installing and fixing in position of façade/structural glazing system for all heights and all levels is in the scope of contractor. The façade/glazing system shall be designed for wind load and contractor shall prepare shop drawing based on intent/ concept drawing along with design calculation considering all parameters and submit for the approval of PMC/Employer and shall get approval before mockup/ execution of work. The design calculation of façade/glazing system shall consist of load calculations, design methodology, design of various elements, analysis models such as ETABS/STAAD etc. and contractor shall submit the same to PMC/Employer and get it approved by PMC/Employer before proceeding with execution of work. Shop drawings shall be prepared for the specified design loads conforming to IS 875 part III (the system must pass the proof test at 1.5 times design wind pressure without any failure). Work shall be carried out as per final approved shop drawing and approved mockup. The work shall include cost of all mockups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. Contractor shall provide a watertight structural glazing/facade having all the performance characteristics etc. all complete as required, as per the intent drawing, as per item description, as specified, as per the approved shop drawings and as directed by the PMC/Employer. Contractor shall responsible against stability, safety, leakage, etc all complete.
Conventional Capped Curtain Wall Glazing at double height entrance Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Conventional capped curtain wall system designed to withstand the wind pressure of confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The profile system is based on capped curtain wall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets of Aluminium alloy of 6005 T5 / MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, Anchor fasteners, screws and fasteners with non staining weather sealant and Aluminium flashing sealed all around parameter inside and outside to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.
Transom shall be overlap with mullion to have proper drainage to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
The system shall be designed of floor height units spanning between the floors with Dead load & wind load brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be designed to accommodate 36mm DGU in vision area. System shall accommodate openable panel as per architectural requirement in the system . All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with Black Anodized shall be fixed at all vertical & horizontal grooves. Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet & internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with external & internal aluminium profiles respectively.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External capping & visible surfaces shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.
The system shall have PVDF Coated vertical & horizontal capping of 20mm deep visible in the elevation. End Cover plate to be fix in vertical & horizontal capping
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employer.
All shade approval shall be as per PMC/Employer Approval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Conventional Capped Curtain Wall System Quote rate for complete system as mentioned above under (2.10.1 )
Vision Glass : Extra over 2.10.1 a Quote extra over on item (2.10.1 a) for providing and fixing 36mm thick DGU 10mm Low-e HS + 16mm Air Gap + 10mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC < 0.25 (LEED requirement) U Value < 1.7 W/m2K (LEED requirement)
Automatic Sliding Door : Extra over 2.10.1 a Providing and fixing Compact automatic linear sliding door, TÜV type-tested as per DIN 18650, with self-cleaning rollers, for leaf weights up to 120 kg per leaf System shall have following specifications : • Integrated battery pack for emergency opening or closing in case of power failure • Intelligent digital DCU controller (category 2 as per DIN EN 954-1): • Self-learning • With dynamic adjustment of hold-open time on traffic for optimal comfort • Network able and integrable in building systems • Error self-detection and logging • All movement parameters can be adjusted • Extremely quiet DC drive • Rugged transformer with integrated all poles disconnecting main switch and fuse protection • Static and dynamic force limitation as per new DIN 18650 and under 150 N as per BGR 232 (formerly ZH 1/494) • Automatic reversing on obstacle detection System to hav continuous floor guide, made of anodised E6/EV1 aluminium, can be installed flush to ground, guide rail can be removed for cleaning. Shall also have a rain water drain option. Quote rate for complete system as mentioned above with 12mm Clear FT Heat Soaked Glass 2205mm (W) x 2700mm (H) = 2 Nos.
MS Tonnage: Inserts to suffice the structural requirement of profiles Design, Fabrication, Supply and install required structural steel frame work in line with design drawings made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
Semi Unitized Structural Glazing with Horizontal Fin Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Semi-Unitized four sided structurally glazed curtain wall system custom designed to withstand the design wind pressure confirming to IS-875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with microwave cured EPDM gaskets, Two-part structural sealant & non-staining, non-bleeding weather sealants, Open PU cell Spacer tape, backer rod, face mounted / slab mounted bracketing system with MS hot dip galvanized / aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, building plump tolerances as per structural DBR, SS 316 grade fasteners & SS316 anchor fasteners (designed as per cracked concrete condition), nylon / hard PVC separators (upto 3mm and beyond 3mm GI shims which should be tack welded to act monolithic) to prevent bi-metallic contacts, aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.
The system design shall be based on open joint system principle & design shall also include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have condenstion slots & weep holes on vertical side of profile system to avoid condensation. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C - 90C° & differential temperature of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall have transom overlap principle which facilitates the water from transom gutter to flow directly into the mullion gutter, hence avoid water seepage through mullion - transom junction.
The system shall be designed of floor height units spanning between the floors with face / slab mounted brackets or hook-on bracket on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of SS316 anchor fasteners. The bracketing system with aluminium alloy / MS HDG with built in serration & serrated washers. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the DGU and SGU glass thickness in black anodized. System shall accommodate openable panel as per architectural requirement in the unitized system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertical & horizontal grooves. Each glass panel shall be structurally glazed on the main unitized profile system . Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.
The three barrier gasket system consists of 1st Barrier of Silicon Gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. Gaskets shall be of microwave cured (Online Curing) with shore A hardness of 60-65.
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.2mm thk GI sheet. Internal & External exposed flashing shall be 2.5mm thk. aluminium sheet with coating matching with internal & external Aluminium profiles respectively.
Termination of systems with civil or adjoining MS structure shall have one layer of vertical continuous EPDM membrane with 1.2mm thick GI flashing ensuring water and air tightness.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1). Acceptance of equivalent makes is subject to prior approval from client / PMC / architect / consultant.
All shade approval shall be as per client / architect's Approval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Semi-Unitized structural glazing curtain wall system Quote rate for complete hardware as mentioned above under (2.10.2)
Semi-Unitized structural glazing curtain wall system Quote rate for complete Aluminium as mentioned above under (2.10.2)
Spandrel panel : Extra over 2.10.2 a (behind spandrel glass) Quote extra over on item (2.10.2 a) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent
Spandrel panel : Extra over 2.10.2 a (at top Fibre Cement Sheet) Quote extra over on item (2.10.2 a) for providing and fixing the spandrel panel with the 50mm thick Glasswool insulation of density 48kg/m3 held firmly by 1.2mm thick GI tray on both sides.
Fire Stop : Extra over 2.10.2 a (Horizontal smoke seal at floor perimeter) Quote extra over on item (2.10.2 a) for providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.
Top Hung Openable window : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .
Fibre Cement Board Cladding : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 12mm thick Paintable fibre cement board. The paint on the fibre cement board shall be as per architect's intent. Surface should be free to receive any RAL shade chosen by the architect. The cement board shall be held by necessary alum angle as per tender drawings.
Internal Alum. Floor closure extrusion at bund level : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing min. 1.8mm thick aluminium extruded members at skirting / bund / slab level in-line with tender drawings. Internally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
MS Tonnage (Considered 8 kg/sqm of Unitized glazing area) : Suspended supports to support the Unitized Glazing from top Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
Vision Glass : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC < 0.25 (LEED requirement) U Value < 1.7 W/m2K (LEED requirement)
Spandrel Glass : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)
40mm x 150mm Horizontal Fin : Extra over 2.10.2 a Quote extra over on item (2.10.2 a) for providing and fixing PVDF coated horizontal rectangular extrusion profile of size 40mm x 150mm.
Conventional Capped Curtain Wall Glazing at Cafeteria Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Conventional capped curtain wall system designed to withstand the wind pressure of confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The profile system is based on capped curtain wall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets of Aluminium alloy of 6005 T5 / MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, Anchor fasteners, screws and fasteners with non staining weather sealant and Aluminium flashing sealed all around parameter inside and outside to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.
Transom shall be overlap with mullion to have proper drainage to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
The system shall be designed of floor height units spanning between the floors with Dead load & wind load brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU glass spandrel panel. System shall accommodate openable panel as per architectural requirement in the system . All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with Black Anodized shall be fixed at all vertical & horizontal grooves. Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet & internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible & all externally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External capping shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.
The system shall have PVDF Coated vertical capping of 20mm & horizontal capping of 15mm deep visible in the elevation. End Cover plate to be fix in vertical & horizontal capping
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employer.
All shade approval shall be as per PMC/Employer Approval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Conventional Capped Curtain Wall System Quote rate for complete system as mentioned above under (2.10.3 )
Vision Glass : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC < 0.25 (LEED requirement) U Value < 1.7 W/m2K (LEED requirement)
Spandrel Glass : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)
Fire Stop : Extra over (Horizontal smoke seal at floor perimeter) Quote extra over providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.
Spandrel panel : Extra over 2.10.3 a (behind spandrel glass) Quote extra over on item (2.10.3 a ) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent
Spandrel insulation : Extra over 2.10.3 a (at top Fibre Cement Sheet) Quote extra over on item (2.10.3 a ) for providing and fixing the spandrel panel with the 50mm thick Glasswool insulation of density 48kg/m3 held firmly by 1.2mm thick GI tray on both sides.
Fibre Cement Board Cladding : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing and fixing 12mm thick Paintable fibre cement board. The paint on the fibre cement board shall be as per architect's intent. Surface should be free to receive any RAL shade chosen by the architect. The cement board shall be held by necessary alum angle as per tender drawings.
Top Hung Openable window : Extra over 2.10.3 a Quote extra over on item (2.10.3 a ) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .
MS Tonnage (Considered 8 kg/sqm of CCW glazing area) : Suspended supports to support the Glazing from top Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
Aluminium Framed Door Quote extra over on item (2.10.3 a ) for providing & fixing single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1225mm X 3000mm)
3mm thick Solid Alum sheet column cladding Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing , protection, cleaning & handover of aluminium sheet cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.
Prefabricated grid mullions are fixed on to the RCC and concrete masonry walls with SS 316 anchor bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.
The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Quote rate for complete system as mentioned above under (2.10.4)
Semi Unitized Structural Glazing with Vertical Fins - North West, North East, South West, South East Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Semi-Unitized four sided structurally glazed curtain wall system custom designed to withstand the design wind pressure confirming to IS-875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with microwave cured EPDM gaskets, Two-part structural sealant & non-staining, non-bleeding weather sealants, Open PU cell Spacer tape, backer rod, face mounted / slab mounted bracketing system with MS hot dip galvanized / aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, building plump tolerances as per structural DBR, SS 316 grade fasteners & SS316 anchor fasteners (designed as per cracked concrete condition), nylon / hard PVC separators (upto 3mm and beyond 3mm GI shims which should be tack welded to act monolithic) to prevent bi-metallic contacts, aluminium trims and flashings to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ.
The system design shall be based on open joint system principle & design shall also include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have condenstion slots & weep holes on vertical side of profile system to avoid condensation. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C - 90C° & differential temperature of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall have transom overlap principle which facilitates the water from transom gutter to flow directly into the mullion gutter, hence avoid water seepage through mullion - transom junction.
The system shall be designed of floor height units spanning between the floors with face / slab mounted brackets or hook-on bracket on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of SS316 anchor fasteners. The bracketing system with aluminium alloy / MS HDG with built in serration & serrated washers. The system shall be designed to accommodate 32mm DGU in vision area & 6mm SGU in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the DGU and SGU glass thickness in black anodized. System shall accommodate openable panel as per architectural requirement in the unitized system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertical & horizontal grooves. Each glass panel shall be structurally glazed on the main unitized profile system . Each glass panel shall be supported for dead load at the bottom of glass with black anodized glass retainers two per panel.
The three barrier gasket system consists of 1st Barrier of Silicon Gasket and 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. Gaskets shall be of microwave cured (Online Curing) with shore A hardness of 60-65.
Flashing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concealed Flashings shall be 1.2mm thk GI sheet. Internal & External exposed flashing shall be 2.5mm thk. aluminium sheet with coating matching with internal & external Aluminium profiles respectively.
Termination of systems with civil or adjoining MS structure shall have one layer of vertical continuous EPDM membrane with 1.2mm thick GI flashing ensuring water and air tightness.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604 & all externally visible surfaces shall have PVDF finish with minimum 35 micron confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1). Acceptance of equivalent makes is subject to prior approval from client / PMC / architect / consultant.
All shade approval shall be as per client / architect's Approval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Semi-Unitized structural glazing curtain wall system Quote rate for complete hardware as mentioned above under (2.10.2)
Semi-Unitized structural glazing curtain wall system Quote rate for complete Aluminium as mentioned above under (2.10.2)
Spandrel panel : Extra over 2.10.5 a (behind spandrel glass) Quote extra over on item (2.10.5 a) for providing and fixing the spandrel panel with the thermal insulation of thickness and density slab as per firestop and smoke seal suppliers EJ / test certificates firmly held on the powder coated GI tray (thickness of GI tray as per firestop and smoke seal suppliers EJ / test certificates). The assembly is kept atleast 50mm away from the glass surface. The spandrel insulation to have front face as 2mm thick powder coated alum. tray, powder coating shade to be as per architect's intent
Fire Stop : Extra over 2.10.5 a (Horizontal smoke seal at floor perimeter) Quote extra over on item (2.10.5 a) for providing and fixing the tested fire stop for 120min rating with smoke seal at all floor slab levels required as per local fire authority. Voids created between the fire resistance rate floor assembly and the exterior curtain wall shall be protected with a perimeter joint that is designed and tested in accordance with ASTM E 2307 – As per NFPA 101 : Life Safety Code. The fire stop assembly shall run vertical side where there is a shear wall condition or break in horizontal fire stop. The floor closure shall be provided continuously at floor level with 1.2mm thk GI flashing closing gap between transom and building line. Super Durable Powder coated 2mm thick Aluminium flashing shall be provided at the soffit to provide a proper closure at soffit level between the insulation tray and building line.
Top Hung Openable window : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing & fixing the Top Hung Open Out (operable) vent, accessories with heavy duty self balancing stainless steel friction hinges with provision to hold open at 250mm. Vent locking accessories with Cremone lock and handle with multi point locking (with minimum 2 typhoon locks / as recommended by the hardware manufacturer) mechanism to keep the vent weather tight. The vent shall comprise of Aluminium outer frame with drainage provisions, crimped corner & shutter frame with Euro grooves with crimped corners. The outer frame fixed to the unitized profile system with necessary SS screws & weather sealant applied from outside. The stepped glass design vent shall have ceramic frit in black at the portion of the stepped unit in case of high light transmission glass to reduce banding effect in the glazing .
Vision Glass : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing 32mm thick DGU 8mm Low-e HS + 16mm Air Gap + 8mm Clear HS Appearance : As per Client / Architect's approval VLT : 45% - 70% SHGC < 0.25 (LEED requirement) U Value < 1.7 W/m2K (LEED requirement)
Spandrel Glass : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing 6mm thick Ref. SGU (as per PMC/Employer approval)
40mm x 150mm Vertical Fin : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing PVDF coated vertical rectangular extrusion profile of size 40mm x 150mm.
Aluminium Framed Door Quote extra over on item (2.10.5 a) for providing & fixing single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Quote rate for complete system as mentioned above With fittings and panic device under item ( L) including 12mm clear FT - Double Shutter (Size : 1225mm X 3000mm)
MS Tonnage (Glazing at terrace level glazing & terrace copping) Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
Terrace Copping Quote extra over on item (2.10.5 a) for Installation of ACP Copping at terrace level sealing the top gap between the curtain wall & parapet top. ACP Panel shall have GI stiffners below with required Aluminium grid work with necessary MS HDG / Aluminium alloy brackets & fasteners in SS 316. 2nd barrier of 1mm thk GI sheet laid contineously below the copping to seal the parapet & Unitised curtain wall. Overlap of GI sheet shall be properly sealed with weather sealant. The grooves between two copping panels shall be filled with non staining weather selant complete as per drawing and specification. The groove sealed joint to be covered by 2mm thk 60 mm wide Aluminium / ACP strip to protect the sealant detorioration.
Internal Alum. Floor closure extrusion at bund level : Extra over 2.10.5 a Quote extra over on item (2.10.5 a) for providing and fixing min. 1.8mm thick aluminium extruded members at skirting / bund / slab level in-line with tender drawings. Internally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
3mm thick Solid Alum sheet soffit cladding Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa
Design, fabrication, supply, installation, testing , protection, cleaning & handover of aluminium sheet cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.
Prefabricated grid mullions are fixed on to the RCC and concrete masonry walls with SS 316 anchor bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.
The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80°C-90°C & temperature differential of 25°C without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Quote rate for complete system as mentioned above under (2.10.6)
Aluminium Z Louvers Design Wind Pressure : 1.55kPa Proof Wind Load : 2.32kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Aluminium Louvers system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure).
Aluminum Louvers shall be made out of "Z" shape louvers spaced at equivalent distance support to Aluminium grid work. Louvers profile shall be fixed on the 2.5mm thick Al angle to form a frame. The louver frame is supported on the aluminium grid mullions with necessary fasteners in SS 316 & MS / Aluminium alloy brackets with provision to accommoadate movement at all floor levels. The bracketing system with Aluminium Alloy of 6005 T5 / MS HDG with built in serration & serrated washers.
Flasing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continuously with required GI / Aluminium sheet. Internal & External concelled Flashings shall be 1.0mm thk GI sheet. External exposed flashing shall be 3mm thk. Aluminium sheet with PVDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. All the internal visible & all externally visible surfaces shall have Super Durable Powder coating finish with minimum 60-80 micron confirming to AAMA 2604. External fins shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Quote rate for complete system as mentioned above under 2.10.8
Glass Canopy with Spider Fittings Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Glass canopy with spider glazing system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure) with weather sealants, backer rod, Bracketing system with MS hot dip galvanized / Aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, SS 316 grade fasteners & Anchor fasteners, nylon separators to prevent bi-metallic contacts, all complete required to perform as per specification and drawing in conjunction with BOQ.
The stainless steel spider system of Grade 316, supported on MS structure. All the weather sealants shall be non staining of approved make, stainless steel spider system of grade 316 with Articulated bolt assembly, with SS 316 grade fasteners and anchor bolts of approved make, Teflon/ nylon bushes & separators to prevent bi-metallic contacts, all in complete required to perform as per specification and drawing in conjunction with BOQ.
Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for WT 07 made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Glass Canopy system with gutter system Quote rate for complete system as mentioned above under 2.10.9
Canopy Glass: 15.52mm Laminated glass 8mm clear FT with Heat Soak Tested + 1.52mm SGP + 6mm clear FT with Heat Soak Tested
MS Tonnage Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
3mm thick solid aluminium sheet cladding Quote extra over on item ((2.10.9 a) ) for providing & fixing 3mm thick solid alum sheet enclosure beneath the canopy glass. Prefabricated grid mullions are fixed on to MS structure with SS 316 nut-bolts as recommended by approved supplier to support given design loads. The brackets shall have provision movement to accommodate the manufacturing tolerances +/- 20mm plumb incase of steel structure. Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final position. Use of Hot Dipped galvanized brackets with serrations and serrated washers on to Steel structures.
U Channel Glazing at Security Cabin Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of U Channel Glazing system designed inline with the architectural intent. The glass is held all around by mechanically from top and bottom with U Channel & structural silicon. Glass to glass groove to be sealed with DowSil clear silicon.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
SS316 Anchors to be designed as per cracked concrete condition.
All Material Make / Vendor list / Supplier list shall be as per Annexure 1. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
U Channel System Quote rate for complete system as mentioned above under 2.10.10
Vision Glass : Extra over (2.10.10 a) Quote extra over on item (1.10.10 a) for providing and fixing 13.52mm thick Laminated Glass 6mm Clear HS + 1.52mm PVB + 6mm Clear HS
Side Hung operable Window at Security Block Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Providing & fixing the Side Hung vent,. System shall have Euro grooves for the compatibility of European accessories. Cremon handle with multi point locking to ensure air tight sealing . Butt hinges / concealed butt hinges,stay arm with 30o & 90o , Microwave cured EPDM gaskets to acomodate glass thickness as per structural requirement, weather sealants, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Some locking points to be typhoon locks. Location of the operable vent shall be inline with tender drawing.
Microwave cured EPDM gaskets to accomodate glass thickness as per structural requirement, weather sealants, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
The system shall demonstrate performance for air seal / water seal / structural requirement.
Aluminium's stress utilization, MS utilization & anchors utilization shall not exceeding 90%.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
Side Hung Window System Quote rate for complete system as mentioned above under 2.10.11 including all hardwares & accessories
Vision Glass : Extra over 2.10.11 a)(side hung window) Quote extra over on item (2.10.11 a) ) for providing and fixing 6mm Clear HS Glass
Aluminium Framed Door Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa Design, fabrication, supply, installation, testing, protection, cleaning & handover of single leaf aluminium framed door door opening outward / inward (as per tender drawings) custom designed to withstand the design wind pressure. The system shall have two barrier gasket system for weather sealing & provision for aluminium thrash hold at bottom. The profile system shall be of minimum 2.5mm thickness. Door shutter shall have crimped corner at top and SS tie rod at bottom for rigid connection. The system shall have hydraulic door closure mounted on the profiles, three leaf projected type hinges of approved make, Microwave cured EPDM gaskets .Door shutter profile to accommodate the 12mm clear FT glass, weather sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1000mm X 2530mm)
Quote rate for complete system as mentioned above with fittings and door closure including 12mm clear FT - Single Shutter (Size : 1200mm X 2530mm)
Single Shutter Sliding Door Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Sliding Doors / Windows system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The system shall have drainage gutter profile at bottom track with the possibility of drain container, wool pile with silent film for weather protection and complete air seal. The shutter engagement shall be minimum of 12mm at top and bottom track to ensure stability under deflection of vertical mullions. The track profile to be designed to ensure smooth movement of the shutter with the rollers of needle bearings or ball bearing.
The system shall be designed to accomodate European accessories with Heavy duty roller assembly considering the weight of the shutters and flush type lock with manual operation. Microwave cured EPDM gaskets to accomodate glass thickness as per structural requirement, weather sealants, top & bottom shutter guides, anticapillary at interlock junction for proper sealaing, SS 316 grade screws of approved make, all in complete required to perform as per specification and drawing in conjunction with BOQ. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness at mechanical engagement points. All the internal & external visible surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per Annexure 1. Acceptance of equivalent makes is subject to prior approval from PMC/Employert.
All shade approval shall be as per PMC/EmployerApproval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all taxes, duties, statutory obligations and safety code compliance as per PMC.
Quote rate for complete system as mentioned above 1225mm (W) x 2530mm (H) = 2 Nos.
Aluminium Baffles Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, fabrication, supply, installation, testing, protection, cleaning & handover of Aluminium Box Profile Baffle Ceiling system custom designed to withstand the design wind pressure which is confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure).
Aluminum system shall be of HunterDouglas product V100 or equivalent at C/C spacing of 100/150/200mm as per Architect's approval. The louver frame is supported on the MS structural frame work with necessary fasteners in SS 316 & MS brackets with provision to accommoadate movement at all floor levels.
The extruded aluminium sections of Alloy 6063 T6 & tolerances confirming to DIN / EN standard from approved extruder. All the visible surfaces shall have Superdurable powder coating of 60 - 80 micron confirming to AAMA 2604. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification. Acceptance of equivalent makes is subject to prior approval from Client / PMC / Architect
All shade approval shall be as per Client / PMC / Architect's approval.
The quote rate shall include all design, engineering & shop drawing approval from Client / PMC / Architect . The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC / Client.
Bafffle System Quote rate for complete system as mentioned above
MS Tonnage (Considered 20 kg/sqm) : Suspended supports for baffles Design, Fabrication, Supply and install required structural steel frame work in line with design drawings for made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)
ACP soffit cladding FR class B (At First Floor Level) Design Wind Pressure : 1.20kPa Proof Wind Load : 1.80kPa
Design, Fabrication, Supply, installation, Testing , protection, cleaning & handover of Aluminium composite cladding of approved make in solid or metallic colours as per architect's approval Using grid work of prefabricated aluminium extruded sections to with stand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure). The fastening brackets of Aluminium alloy 6005 T5 / MS with HDG with serrations and serrated washers to arrest the wind load movement, fasteners and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing in conjunction with BOQ.
The 4mm thk ACP consists of 0.5mm outer skin of Aluminium with Lumiflon based fluorocarbon paint or kynar 500 based PVDF paint confirming to AAMA 2605 + 3mm FR Grade mineral core material (Fr Grade Class B as per EN 13501) + 0.5 mm aluminium skin with service coat. The panel shall be designed for 15mm groove in horizontal & 15mm groove in verticals with close joint system. Vertical & Horizontal groove shall be filled by non staining high performance weather sealant. ACP panel shall have subframe all around panel and aluminium stiffner profile as per structural requirments.
Prefabricated grid mullions are fixed on to the RCC and concrete walls with SS 316 anchor bolts as recommended by approved supplier to support given desing loads. The brackets shall have provision movement to accommodate the construction tolerances with + 35mm plumb in case of RCC structure and + 20mm plumb incase of steel structure . Use of aluminium brackets with serration and serrated washers to prevent wind direction movement after final postion. Use of Hot Dipped galvanised brackets with serrations and serrated washers on to Steel structures.
The design shall accommodate the building movements, thermal expansion and seismic movements. Also shall accommodate thermal expansion resulting from surface temperature of 80-90 deg cel on ACP outer skin without creating any additional stress.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The structural profiles shall have minimum 2.5mm wall thickness. Externally visible surfaces shall be PVDF coating with minimum coating thickness of 30-35microns confirming to AAMA 2605 with min 30 years warantee. The non visible aluminium surfaces shall have minimum chromatizing treatment. Complete system shall be warranteed for minimum 10 yrs against design & workmanship defects.
All Material Make / Vendor list / Supplier list shall be as per tender specification. (Annexure 1)
All shade approval shall be as per Architect's Approval.
The system shall demonstrate performance for air seal / water seal / structural /seismic requirement. Onsite test for workmanship verification shall be carried out in stages for water penetration hose test as per AAMA 501.2 at minimum 6 locations.
The quote rate shall include all design, engineering & shop drawing approval from architect & consultant. The quote rate shall include all Taxes, duties, statutory obligations and safety code compliance as per PMC.
ACP Cladding with close joint system as mentioned above under (2.10.15)
Quote rate for complete system as mentioned above under 2.10.15 including 4mm thk. Class B FR grade ACP
Performance Mockup Test at NABL Accredited laboratory of Unitized Glazing System 3bay x 2 floor height • Pre-Load for 50% of +ve design wind pressure - 1500 Pa • Air Infiltration test –300 Pa (As per ASTM E 283) • Static water test –450 Pa (As per ASTM E 331) • Dynamic water test –450 Pa (As per AAMA 501.1) • Wind load serviceability test 100%, +ve design wind pressure –2000 Pa (As per ASTM E 330) • Wind load serviceability test 100%, -ve design wind pressure –2000 Pa (As per ASTM E 330) • Repeat air Infiltration test –300 Pa (As per ASTM E 283) • Repeat static water test –450 Pa (As per ASTM E 331) • Proof load test 150% +ve design wind load –2250 Pa (As per ASTM E 330) • Seismic rack test
Onsite Water test as per AAMA 501 by NABL Accredited Laboratory
At Unitized Glazing Area: 3 Locations
At Conventional Cap Curtain Wall Glazing Area (Entrance Glazing) : 2 Location
At Conventional Capped Curtain Wall Glazing Area (Cafeteria) : 1 Location
BMU Type 01- Floor Mounted BMU On Twin Track
Design, manufacture, supply, transportation and installation ofFloor Mounted BMU On Twin Track (Type-1) With Luffing Jib (Max Outreach = 5.7m & Height 2.8m) integrated with Glass Replacement unit capacity-200kg, double suspension cradle, Galvanized steel track including all necessary fixing arrangement as per requirement complete as directed by project manager/As per site condition. The trolley rigid base frame has four traversing wheels for a safe load distribution. Each front wheel is equipped with an electrical driven geared motor. Limit switches control and stop the movement when the path end is reached. The machine has a base frame mounted on wheel assemblies designed to run on single L-Angle guide rail fixed to the parapet wall. (Note :- The Contractor must provide details of structural calculations and also provide shop drawings and all details - clearly indicating all dimensions, fixing details etc. for approval. Vendor visit the site and review the drawings before quote, nothing extra shall be paid. ) BMU should have following technical Spec. 1. Safe working load 240kg. 2. Glass replacement unit capacity 200kg , permanently fixed to BMU. 3. Main Hoisting system- Multilayer drum winch (No friction type/Traction type). 4. Should have four individual wire rope (2 for working,2 for safety). 5. All Steel parts to be Galvanized for minimum 100 microns. 6. Restraint autostop function and indicator to be provided in the cradle. 7. Wire rope make to minimum Brugg/Gustav Wolf of core conductor. Not less than 7mm,Length accoridng to Building height requirement 8. Lufing Jib and mast with all safety values. 9.Double Suspension Cradle Articulated Cradle
Floor Mounted BMU On Twin Track (Outreach 5.7 Meter )
Glass Replacement Unit capacity 200kg
Double Suspension Articulated Cradle
Twin Track Hot dip Galvanized
Base Plates Grade E-350 C/C-2.0 M
SS 316 Chemical Anchors fixed with Hilti/Fischer Chemical
SS 316 grade Nut-Bolt
BMU Type 04- Restraining System
Design, manufacture, Supply of S.S. 316 grade Restraining Socket ( As per drawing attach) - Supply Only - Excluding Fixinging Accessories. Fixing will be done by fabricator. To comply with BS EN 1808 standards, external use suspended façade access equipment suspension ropes must be restrained to the façade. The following statement taken from BS EN 1808 standards outline the requirement of the façade restraint system: 1. The lowest restraint point shall not be more than 40 meters above the lowest working level. 2. The distance between restraints above 40 meters shall not exceed 20 meters. 3. The restraint lanyards shall be attachable & detachable by an operator on the platform in a safe manner.
SS 316 Restraining Pins/Lanyard
Providing & Fixing Glass Fibre Reinforced concrete made from OPC 53 gradecement/White Cement, quartz sand, Alkali Resistant Glass (manufactured by Nippon Electric Glass or Owens Corning), with UV stable pigments, suitable acrylic polymers. No metal/mesh reinforcement to be used in the GFRC panel & fixed with stainless steel cleats and anchors. GFRC must have a minimum flexural strength of 8 N/mm2 and must have a minimum density of 2 g/cc. The water absorption must be less than 10% as measured by ASTM standards
Central Feature
Entrance Canopy
Horizontal Bands
Main Entrance
HARD LANDSCAPE WORKS
Supplying and fixing of pre-cast kerb stone of size 450x300x150mm made in CC 1:3:6 (One of cement, three of sand and six of hard broken stone jelly) using 20mm size hard broken stone jelly including the cost of Kerb stone moulding, laying, curing, transporting, pointing and as directed by the Project Officer.
Turf paver
Providing and laying 500x500x40mm thick Turf paver (Turfpave XD)on 150mm thick sub grade of compacted bed of 20mm thick nominal size stone aggregate and base course and filling with 150mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.
Tactile paving
Supplying and laying of Tactile Paver Block Stone 15 mm thk. Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc.,
EXTERNAL INFRASTRUCTURE WORKS
Road Work
Construction of Subgrade (Construction of subgrade with approved material having CBR 8% or more with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of PMC/Employer and accordance with applicable specifications.
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of PMC/Employer
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by PMC/Employer, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the PMC/Employer(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
Overhead informatory road signage
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of PMC/Employer
Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered,LED self illumination in active mode, 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 Kilograms. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.
Supply of imported outdoor Polycarbonate Convex Mirror with 130 Degree + actual viewing angle, equipped with adjusting swivel and mounting bracket for infinite adjustment. Diameter – 100 cm outdoor
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of PMC/Employer
Providing and fixing Rubber Speed Breaker in yellow & black shade with load capacity of 30 ton, moisture resistant of size 500mm 350mm x 50mm & having end cap from both ends as per approved make by design architect. ( Rate to include the required hardware accessories etc )
Supply & installation of 40 inch Concave mirror with scratch proof & dimensional accuracy with required accessories, Hardware, etc of approved make from design architect & as per manufcaturers specificaiton
Providing and fixing yellow & black rubber Wheel stopper for parking area with size 1840mmx 150mm x 100mm of approved make by design architect . ( cost to include installation charges along with necessary hardware, accessories, etc )
Supplying and laying of Interlocking Paver Block Stone 83mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers.
IRRIGATION
Manual Irrigation Works
Description
Pipes Work: Supply, laying & commissioning in position PVC pipe conforming to IS:4985:2000 and suitable for the respective working pressures without all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc., complete.
uPVC Pipe 63 mm dia / 6 Kg / sq. Cm.
uPVC Pipe 40 mm dia / 6 Kg / sq. Cm.
uPVC Pipe 20 mm dia / 10 Kg / sq. Cm.
Specials like Tee, Elbow,Reducr, Bush, Solvent, MTA,FTA,Union,Tailpiece etc., @ 30 % of uPVC Pipe value
Earth work excavation and refilling 300x450mm
Core cutting in concrete slab/brick wall for pipe routing Up 63 to 110 mm dia
SOFT LANDSCAPE WORKS
Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. .
Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth.
Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre- measurements obtained from sand deposits and should clean without solid particles
"Mixing charges of Red soil, manure and pit sand uniformly (2:2:1) for Preparation of soil mixture (excluding material cost)"
Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller.
Filling mixture of Red soil, manure and pit sand in the desired proportion in trenches, flooding with water and leveling (cost of supplyingRed soil, manure and pit sand and mixing excluded).
PLANTING PIT PREPARATION
Earth work excavation for foundation in all kinds soils in varying depths (Digging of new trenches for hedge / edge planting, digging and removal of excavated earth from site complete)
SUPPLYING & PLANTING OF PLANTS
Supplying & planting of trees
Supplying and planting at site healthy,disease free and well developed Trees.of the prescribed height and spread as per detail below, supported with casuarina stakes, including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthenpot of of size as mentioned below.
Providing, stacking and planting of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the PMC / Employer
Providing, stacking and planting of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the PMC / Employer
Providing,stacking and planting of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Cassia fistula (Amaltash) of height 120-135 cm. In big poly bags of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Erythrina indica of height 150-165 cm. in big polybag of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Millingtonia hortensis of height 150-165 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Mimusops elengi (Maulsri) of height 150-165 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Pongamia glabra (Papri) of height 120-135 cm. In big poly bag of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Eugenia jambolana (Jamun) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Tamarindus indica (Imli) of height 120-150 cm. In big polybags of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the PMC / Employer.
Providing,stacking and planting Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the PMC / Employer.
Providing,stacking and planting of Plumeria rubra of height 120-150 cm. With 3-4 branches and thick stem in big size HDPE bags as per direction of the PMC / Employer.
"Supplying and Planting of Terminalia Metalica (Terminalia mantalay variegated) ornamental foliage Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."
`Supplying and Planting of Terminalia Metalica green (Terminalia mantalay green) ornamental foliage Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Supplying & planting of shrubs
Supplying and planting at site healthy,disease free and well developed shrubs of the prescribed height as per detail below including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthen pot of size as mentioned below.
Providing, stacking and planting Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the PMC / Employer.
Supplying and Planting of Dypsis lutescens (Areca palm) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Providing, stacking and planting Bougainvillea named Cherry Blossom well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the PMC / Employer.
Providing, stacking and planting Bougainvillea named Thima well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the PMC / Employer.
"Supplying and Planting of Euphorbia milli foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by thePMC / Employer."
Providing, stacking and planting of Excoecaria bicolor of height 45-60 cm. in earthen pots of size 20 cm as per direction of the PMC / Employer.
Supplying and Planting of Ficus black ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Providing, stacking and planting of Ficus reginald well branched, bushy of height 45- 60 cm. in earthen pots of size 25 cm as per direction of the PMC / Employer.
Providing, stacking and planting of Gardenia jasminoides of height 45-60 cm. With 3- 4 branches in earthen pots of size 20 cm as per direction of the PMC / Employer.
"Supplying and Planting of Hemelia pattens foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."
Providing, stacking and planting of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the PMC / Employer.
Providing, stacking and planting of Hibiscus variegated of height 60-75 cm. With healthy variegated foliage in earthen pots size 25 cm as per direction of the PMC / Employer.
Planting of Jetropha Plant (Jatropha multifida) foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Providing, stacking and planting of Malpighia coccigera of height 30-45 cm., multibranched in earthen pots of size 20 cm as per direction of the PMC / Employer.
"Supplying and Planting of Nerium oleander foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."
Providing, stacking and planting of Nerium oleander variegated of height 45-60 cm in earthen pots of size 20 cm as per direction of the PMC / Employer.
Supplying and Planting of Plumbago (Plumnbego capensis) foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
"Supplying and Planting of Tabernum (Tabernaemontana coronaria) green foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."
Supplying and Planting of Tecoma goudi choudi foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Planting of Adenium (Adenium obessum) Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Providing, stacking and planting of Raphis palm having ht. 75 cm to 90 cm with 12 to 15 equal suckers, well developed, full of fresh & healthy leaves from bottom to top in 25 cm size Earthen pot/Plastic pot & as per direction of the PMC / Employer.
Supplying & planting of groundcovers
Supplying and planting at site healthy,disease free and well developed groundcovers of the prescribed height as per detail below including cost of transportation, loading and unloading and providing the required intermittent care in the course of transportation and upto plantation. Plants to be supplied in polybag / HDPEbag / earthen pot of size as mentioned below.
Providing, stacking and planting of Cuphea chinensis of ht. 20-30 cm full of branches and healthy foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the PMC / Employer.
Supplying and Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Supplying and Planting of Wedelia trilobata foliage Ground cover variety in Polythene bag of size 6x7 inch the rate including loading and unloading charges, transportation, stacking of sapling at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by thePMC / Employer.
Supplying and Planting of Chlorophytum ornamental foliage Ground cover variety in Polythene bag of size 6x7 inch the rate including loading and unloading charges, transportation, stacking of sapling at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Supplying & planting of lawn
Turfing of Mexican grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
MAINTENANCE
Maintenance of shrubs, other ornamental foliage, foliage planting and Trees planting including watering, weeding, application of fertilizers and pesticides, trimming etc for One month
Maintenance of shades grass / carpet grass / G2 grass by regular watering, weeding, protection, mowing etc for a period of One month
Supplying and fixing in position SFRC manhole covers of 40 tonnes with frames (Heavy duty) of size 60cm Dia of best approved quality as per standard specification etc., complete compying with standard specifications . Item includes all transportation, lifting, machinery, fixing in position, labour etc required to complete the job
ELECTRICAL WORKS
HT PANELS
33 KV Ring Main Gear (RMG) - OutdoorType Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Ring Main Gear Comprising of Incomer : 2nos 800A ,31.5 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements (AS PER TANGEDCO NORMS). Outgoings : 1no of 800A, 31.5 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements (AS PER TANGEDCO NORMS). Busbars: 33KV,800A,TP,50Hz,31.5 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets and as per TANGEDCO Requirements. The panel suitable for outdoor mounting & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. RMG yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items. Note: Vendor should procure the RMG as per latest amendement from TANGEDCO and Metering and Protection should be supplied as per TANGEDCO Requirements. No additional payment shall be provided from client.
33 kV HT 1 VCB Panel - 1 (Outdoor Type ) Design, Manufacture, Assembly, Inspection and Testing before supply,Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Panel-1 Comprising of Incomer : 1no 800A ,31.5 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, Arc flashrelay,, CTs, PT with necessary control fuses/MCBs,Terminal Blocks, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets. The panel suitable for outdoor mounting & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. HT panel yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items.
33 kV HT 4 VCB Panel - 1 (Indoor Type ) Design, Manufacture, Assembly, Inspection and Testing before supply,Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase ,three wire,33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Panel-1 Comprising of Incomer : 1no 800A ,31.5 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements Outgoings : 3nos of 800A, 31.25 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements Busbars: 33KV,800A,TP,50Hz,31.5 KA, Copper. Busbars The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, Arc flashrelay,, CTs, PT with necessary control fuses/MCBs,Terminal Blocks, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets. The panel suitable for outdoor mounting & terminating of 400 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. HT panel yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items.
HT CABLE
Supply, Laying, testing and commissioning of 3 core 400 sqmm 33KV, XLPE Aluminium conductor individual core screened, PVC sheathed, flat steel strip armoured earthed cable with specified IS 7098/11/85 with latest amendments. in hume pipe / cable trench (From 33KV RMG to HT 1 VCB panel-1, 4VCB panel-1 ) If Cable shall be laid in ground , necessary excavation, sand brick protection and back filling of trench and made good as necessary for laying open with necessary cleats, clamps, pipe sleeves screws etc.
Supply & Installation of indoor type heat shrinkable end termination kits and making End Terminations for XLPE insulated HT power cables 33kV (E) grade of 3Cx400sqmm size, including double Compression Gland of brass type, Aluminium lugs for Aluminium Cables and Bimetallic lugs at tranformer/panel end,including supply and fixing as per specification and direction of PMC / Employer.
Supply & Installation of outdoor type heat shrinkable end termination kits and making End Terminations for XLPE insulated HT power cables 33kV (E) grade of 3Cx400sqmm size, including double Compression Gland of brass type, Aluminium lugs for Aluminium Cables and Bimetallic lugs at transformer/ panel end,including supply and fixing as per specification and direction of PMC / Employer.
Substation Battery Charger: Design, supply, erection, testing and commissioning of Battery Charger 110V DC 200 AH Trip unit combined with trickle and Float & Boost charging facilities with battery banks (SMF) & Distribuition Board and complete with all accessories like insulators, clamps, bimetal connectors, M.S.support rack as required and as per technical specifications.
TRANSFORMERS
DRY TYPE DISTRIBUTION TRANSFORMER Design, Engineering, Manufacturing, Supply and supervision , installation, testing and commissioning of 2500KVA , 33kV/433V, Cast Resin Dry Type Distribution Transformer, 3ph, 50Hz, with vacuum break On Load Tap changer on HT side & Insulation level Class F insulated, Vector Dyn11, Continuous duty, AN cooling, copper wound as per relevant standard with Resistive temperature detectors with enclosure should be embedded in winding, ventilation fans, RTCC panel, Marshalling box, Bidirectional rollers, HV Side Cable box & LV Side adapter box for connecting Bus duct, Painting to be RAL-7032. Transformer suitable indoor type distribution mounted inside enclouser with all standard accessories,Transformer shall be as per single line diagram and specifications / Technical Data Sheets. Enclosure for mounting Class PS Neutral CT for REF protection to be provided. The Transformer supplier shall co-ordinate with the panel vendor & install the Neutral CT . OLTC Tap settings: -10 % to +10%, 2.5% for each step. Primary Voltage: 33000V Secondary Voltage:433V. Losses- As per ECBC Building 2017. Lockable Emergency Push button should be provided . The civil works like construction of plinth, foundation etc shall be carried out by others. However, the correct sizes including type of construction shall be specified and a shop drawings shall be submitted by transformer supplier for approval before execution for review & approval by PMC / Employer. Note : Factory testing shall be carried out as per the technical specifications on all the transformers. Testing shall include all routine tests as per latest IS / IEC standards and type test as mentioned in the specifications etc. All routine and type tests shall be carried out on all the transformers with out any extra cost as per PMC/ EMployer.
LT PANELS
Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz, fully compartmentalized cubical type, fabricated with CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP Copper alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity as mentioned in the below & SLD, bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4B with metallic separation only entire panel shall have a common copper earth bar size as per OEM requirements at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Cu. bus bars, interconnection, interlocking between feeders etc., Annuntiation window requirement shall be as per SLD. with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. PVC insulated FRLS copper conductor , cable alleys, cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec. All MCCBs shall be rating for Ics=Icu as per provided SLD. All MCCBs above 63A should be provided with Copper Spreader Terminals.Marshalling Bay To Be Provided for BMS Operation Please consider IP42 for Indoor panel & IP 55 for out door panels if it is not specified . Approval shall be taken for each panel before fabrication. contractor to consider the termination requirement as per the cable sizes sheet provided.
If any additional termination box is required the same shall be considered by contractor in the panel cost itself. The fault level of the component shall be same as the bus bar fault level indicated. The panel shall be designed to suit to the site condition. If any U shape/L shape panels required as per site requirement, contractor to consider all required dummy panel, adaptor boxes, bus bar extension, other accessories, etc. in the panel cost itself. All the cost required for BMS integration like cable,control modules,converters, connectors etc as per the attached scheme shall be included in panel cost itself. The scope shall include relay coordination study. ON / OFF / TRIP status for all the incomming breakers (ACB, MCCB, MCB, MPCB, RCBO) & meter parameter from all main LT panel (Listed Below) to be provided through modbus IP output (PLC) to connect to BMS through ethernet switch located within one of the panels in each electrical room. All cost towards cable, ethernet switch, BMS interface module, etc shall be covered in the panel cost itself. LT panel with 400A & above shall be OEM Certified ( IEC 61439) type tested approved design. Below 400A shall be as per IEC 60439 design. All VFDs shall comply with IEC 61800-3 & have THD less than 5% which will be in scope of Drive authorized supplier of OEM as per list of approved make. Surge Protection device of sutibale type and range to be considered as per the SLD. Any details indicated in SLD and specification is also need to be consiedered for panel cost. Any details indicated in SLD and specification is also needs to be consiedered for panel cost. Internal ARC Flash test shall be provided for Mian LT Panels. Type Test certificates shall be submitted for all panel and its componenents. Note : Refer the SLD
MPCC PANEL - 1
Incomer 4000A 4P EDO ACB 65 KA with microprocessor based O/L, S/C and E/F -4 Nos. Suitable for Bus Duct termination SPD type II, 125KA, FP - 4 nos Multi Function Meter with RS 485 port Interface with Maxmimum Demand Indication & controller .-4 nos. C.T. 4000/5A, CLASS 0.5 15VA- 5sets. C.T. 4000/5A, CLASS PS - 2 sets. Line PT : 415V/v3/110V/v3, Cl.1, 10VA -4 nos For indication lamps please refer to SLD Bus Coupler 4000A FP EDO ACB (65kA),microprocessor based with O/L, S/C & E/F Protection as a buscoupler - 5 no For indication lamps please refer to SLD Mechanical & Electrical interlock between 3 Nos incomers and 1 No. Buscoupler Busbars: 4000A 4P Cu busbar 1sec (65kA)
Outgoings : 65kA ALL ACB / MCCB 2500A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection - 6 nos. C.T. 2500/1A, CLASS 1.0 15VA- 6 sets 2000A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection - 2 nos. C.T. 2000/1A, CLASS 1.0 15VA- 2 sets 1000A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection-4 Nos C.T. 1000/1A, CLASS 1.0 15VA- 4 sets 630A 4P EDO ACB microprocessor based with O/L, S/C & E/F Protection-2 Nos C.T. 630/1A, CLASS 1.0 15VA- 2sets 400A 4P MCCB MP Based O/C, S/C & E/F Release- 8 Nos C.T. 400/1A, CLASS 1.0 15VA- 8 sets Multi Function Meter with RS 485 port.- 24 nos. For indication lamps please refer to SLD for each Outgoings.
The transformer incomer, DG incomer shall be provided with protection relays such as IDMT (3O/C + E/F), REFR (Restricted Earth fault Relay) etc., both the incomers, buscoupler shall be interlocked with mechanical and electrical arrangements by hardware control wiring along with PLC (Programmable Logic Controls). The PLC should have suitable communication port for BMS integration. All incoming and Outgoing breaker should be communicable for status monitoring. Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification. refer SLD
MPCC PANEL - 2
Incomer 4000A 4P EDO ACB (65kA) with microprocessor based O/L, S/C and E/F - 2No. Suitable for Bus Duct termination SPD type II, 125KA, FP -2nos. Multi Function Meter with RS 485 port Interface with Maxmimum Demand Indication & controller.- 2 nos. C.T. 4000/5A, CLASS 0.5 15VA- 2 set. C.T. 4000/5A, CLASS PS - 2 sets. Line PT : 415V/v3/110V/v3, Cl.1, 50VA - 4 nos For indication lamps please refer to SLD Bus Coupler 4000A FP EDO ACB (65kA),microprocessor based with O/L, S/C & E/F Protection as a buscoupler - 1 no For indication lamps please refer to SLD Mechanical & Electrical interlock between 3 Nos incomers and 1 No. Buscoupler Busbars: 4000A 4P Cu busbar 1sec (65kA)
Outgoing : 65kA ALL ACB / MCCB 2000A 4P EDO ACB microprocessor based with O/L, S/C & inbuilt E/F Protection - 2nos. C.T. 2000/1A, CLASS 1.0 15VA- 2sets 1000A 4P EDO ACB microprocessor based with O/L, S/C & inbuilt E/F Protection -5nos. C.T. 1000/5A, CLASS 1.015VA- 5sets 800A 4P EDO ACB microprocessor based with O/L, S/C & inbuilt E/F Protection- 2Nos C.T. 800/5A, CLASS 1.0 15VA- 2 sets 630A 4P EDO MCCB microprocessor based with O/L, S/C & inbuilt E/F Protection- 2Nos C.T. 630/5A, CLASS 1.0 15VA- 3 sets 400A 4P MCCB MP Based O/C, S/C & E/F Release- 5 Nos C.T. 400/5A, CLASS 1.0 15VA- 4 sets Multi Function Meter with RS 485 port.- 16nos. For indication lamps please refer to SLD for each Outgoings.
The transformer incomer, DG incomer shall be provided with protection relays such as IDMT (3O/C + E/F), REFR (Restricted Earth fault Relay) etc., both the incomers, buscoupler shall be interlocked with mechanical and electrical arrangements by hardware control wiring along with PLC (Programmable Logic Controls). The PLC should have suitable communication port for BMS integration. All incoming and Outgoing breaker should be communicable for status monitoring. Please refer to single line diagram and technical specification for more details Supply, Installation, testing & commissioning of Inert type Novec-1230/FM200 Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification. refer SLD
APFC PANEL - 1 ,2&3
Incomer 2000A 4P MDO ACB (65kA) with MP Based O/C, S/C & E/F Release- 1No Busbar:2000A TP Cu Busbars (50kA) 1sec Outgoing : Active Filters consists of IGBT based Active technology with complete forced cooling arrangement Interfacing and other control cards, Sensor control card, SMPS, Precharge circuit , Interconnection with UNIVYNIN copper stranded wires, busbars, earth busbar, danger notice boards, inscription plates, terminals for incoming & outgoing cable connections.MCCB, contactor and fuses of applicable rating and protections shall be provided for the active filter. 400 Amp MP Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 100 KVAR capacitor bank). - 4Sets 200 Amp MP Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 50 KVAR capacitor bank). - 6Sets 63Amp TM Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 25 KVAR capacitor bank). - 2Sets 32Amp TM Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 5 KVAR capacitor bank). - 1Sets 32Amp TM Based O/C & S/C Release MCCB (50kA) with suitable rating TP capacitor duty contactor (Suitable for 5 KVAR capacitor bank). - DUMMY CT with Analog Ammeter with selctor switch -1set for each outgoings Indication lamp please refer to SLD Instruments Panel - 7 inch LCD touchscreen for all parameters related to IGBT based system - 01No Please refer to single line diagram and technical specification for more details. Hybrid APFC Panel shall comprise IGBT based active technology (for reactive and harmonics compensation) and detuned capacitor banks(for reactive compensation). The entire system shall be controlled through a single integrated controller for Active and Detuned capacitors.
300A AHF PANEL
DG SYNC. PANEL
Outgoings: 3No - 4000A 65KA 4P ACB, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. wth front drive kit 1No - 400A 65KA 4P MCCB, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. wth front drive kit Metering for Each outgoing: 1No - Load Manager with RS485 Interface with suitable Cts 1 Sets - 63A 4P MCB 1set - RYB LED type indication lamps for Phase 1set - RGA LED type indication lamps for ON/OFF/Trip 1Set - Control MCB with Neutral link
UTILITY PANEL
Incomer 630A 4P ATS - 1 Nos. 630A 4P MCCB (36kA) with microprocessor based O/L, S/C and E/F - 1 Nos. RYB on, off trip indication lamp -3 set. C.T.630/5A, CLASS 0.5 10VA- 1 set. Multi Function Meter with RS 485 port.-1nos. Electrical interlock between 3 incomers Busbars: 630A TPN Cu. Busbars: (36kA) ,1sec Outgoing : 250A 4P MCCB TM based O/C & S/C Release (25kA) - 2 nos. C.T.250/1A, CLASS 1.0 10VA- 2set 125A 4P MCCB TM based O/C & S/C Release (25kA) - 7 nos. C.T.125/1A, CLASS 1.0 10VA- 7set 63A 4P MCCB TM based O/C & S/C Release (25kA) - 2 nos. C.T.63/1A, CLASS 1.0 10VA- 1set On, off trip indication lamp - 1sets. Please refer to single line diagram and technical specification for more details
VENTILATION MAIN PANEL
Incomer 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P Cu Busbars: (36kA),1Sec Outgoing : 100A TPN MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.100/5A, CLASS 0.5 10VA- 4 set
SUB VENT PANEL-TRANSFOMER
Incomer 100A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.100/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 100A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCCB TM based O/C & S/C Release (16kA) -10 nos. C.T.63/5A, CLASS 0.5 10VA- 8 set
SUB VENT PANEL-DG SET
Incomer 100A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.100/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 100A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCCB TM based O/C & S/C Release (16kA) -8 nos. C.T.63/5A, CLASS 0.5 10VA- 8 set
SUB VENT PANEL-CHILLER
Incomer 100A 4P MCCB (25kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.100/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 100A 4P Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCCB TM based O/C & S/C Release (16kA) -8 nos. C.T.63/5A, CLASS 0.5 10VA- 6 set
SUB POWER PANEL
Incomer 100A TPN MCCB (25kA) -1No RYB on, off trip indication lamp -1 set. C.T.100/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 100A TPN Cu Busbars: (35kA),1Sec Outgoing : 63A TPN MCB (16kA) -4 nos. C.T.63/5A, CLASS 0.5 10VA- 4 set
SUB POWER IBMS PANEL
Incomer 125A TPN MCCB (25kA) -1No RYB on, off trip indication lamp -1 set. C.T.125/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 125A TPN Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCB (16kA) -5nos. C.T.63/5A, CLASS 0.5 10VA- 5 set
PRIMARY PUMP PANEL
Incomer 250A 4P ATS (36kA) - 1No 250A 4P TM MCCB (36kA) O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp - 1 set. C.T. 250/5A, CLASS 0.5 10VA- 1 nos. SPD type II, 36KA, FP - 1 nos. Multi Function Meter with RS 485 port.- 1no. Busbars: 250A TPN Cu Busbars (36kA) 1Sec Outgoing : 80A 4P MCCB 36KA - 7 Nos 2NO+2NC PFC-6 Nos SD-6 Nos For indication lamp refer SLD. Please refer to single line diagram and technical specification for more details
COOLING TOWER PANEL
Incomer 800A 4P ATS (36kA) - 1No 800A 4P MPMDO (36kA) O/C, S/C & E/F Release- 1No RYB on, off trip indication lamp - 1 set. C.T. 800/5A, CLASS 0.5 10VA- 1 nos. SPD type II, 36KA, FP - 1 nos. Multi Function Meter with RS 485 port.- 1no. Busbars: 800A TPN Cu Busbars (36kA) 1Sec Outgoing : 100A 4P MCCB 25KA - 8 Nos 80A 4P MCCB 25KA - 6 Nos 2NO+2NC PFC-12 Nos SD-12 Nos For indication lamp refer SLD. Please refer to single line diagram and technical specification for more details
CHILLER PANEL;1,2 &3
Incomer 1000A 4P 36KA ATS - 1 No. 1000A 4P MDO ACB (36kA) with microprocessor based O/L, S/C and E/F - 1 No. SPD type II, 36KA, FP - 1 no. C.T.1000/5A, CLASS 0.5 10VA- 1set. Multi Function Meter with RS 485 port.- 1no. For indication lamps please refer to SLD Busbars: 1000A TPN Cu Busbars (36kA) 1Sec Outgoing : 25kA ALL MCCB 630A 4P MCCB MP Based O/C & S/C Release - 3 Nos C.T. 630/1A, CLASS -1.0 10VA- 3 sets For indication lamps please refer to SLD Please refer to single line diagram and technical specification for more details
GF-EV CHARGING PANEL-1&2
Incomer 400A 4P 36KA ATS-1no. 400A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.400/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 400A 4P CU Busbars: (36kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.63/5A, CLASS 0.5 10VA- 4 set 125A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.125/5A, CLASS 0.5 10VA- 4 set
HUB ROOM PANEL MAIN BUILDING
Incomer 125A TPN MCCB (25kA) -1No RYB on, off trip indication lamp -1 set. C.T.125/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 25KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 125A TPN Cu Busbars: (25kA),1Sec Outgoing : 63A TPN MCB (16kA) -4 nos. C.T.63/5A, CLASS 0.5 10VA- 4 set
POWER PANEL LEFT WING (GF,4F,7F & RIGHT WING 4F,7F)
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (25kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -4 nos. C.T.40/5A, CLASS 0.5 10VA- 4 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.40/5A, CLASS 0.5 10VA- 8 sets Multi Function Meter with RS 485-12 nos Please refer to single line diagram and technical specification for more details
GF POWER PANEL RIGHT WING
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/5A, CLASS 0.5 10VA- 3 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.40/5A, CLASS 0.5 10VA- 8 sets Multi Function Meter with RS 485-11 nos Please refer to single line diagram and technical specification for more details
1F POWER PANEL LEFT WING
Incomer. 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -6 nos. C.T.40/5A, CLASS 0.5 10VA- 6 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -4nos. C.T.63/5A, CLASS 0.5 10VA- 4 sets 125A 4P MCCB TM based O/C & S/C Release (25kA) -2nos. C.T.125/5A, CLASS 0.5 10VA- 2 sets Multi Function Meter with RS 485-12 nos Please refer to single line diagram and technical specification for more details
1F POWER PANEL Right WING
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.40/5A, CLASS 0.5 10VA- 5 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -7nos. C.T.63/5A, CLASS 0.5 10VA- 7 sets Multi Function Meter with RS 485-12 nos Please refer to single line diagram and technical specification for more details
POWER PANEL LEFT WING(2F,3F,5F,6F,8F)
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) M P Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CUBusbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -5 nos. C.T.40/5A, CLASS 0.5 10VA- 5 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -8nos. C.T.63/5A, CLASS 0.5 10VA- 8 sets Multi Function Meter with RS 485-13 nos
POWER PANEL RIGHT WING (2F,3F,5F,6F,8F)
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MPBased O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -3 nos. C.T.40/5A, CLASS 0.5 10VA- 3 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -9nos. C.T.63/5A, CLASS 0.5 10VA- 9 sets Multi Function Meter with RS 485-12 nos
9F POWER PANEL LEFT WING
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -6 nos. C.T.40/5A, CLASS 0.5 10VA- 6set 63A 4P MCCB TM based O/C & S/C Release (25kA) -7nos. C.T.63/5A, CLASS 0.5 10VA- 7 sets Multi Function Meter with RS 485-13nos
9F POWER PANEL RIGHT WING
Incomer 250A 4P 36KA ATS-1no. 250A 4P MCCB (36kA) MP Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.250/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 250A 4P CU Busbars: (36kA),1Sec Outgoing : 40A 4P MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.40/5A, CLASS 0.5 10VA- 8 set 63A 4P MCCB TM based O/C & S/C Release (25kA) -3nos. C.T.63/5A, CLASS 0.5 10VA- 3 sets Multi Function Meter with RS 485-11 nos
VENTILATION PANEL LIFT WING
Incomer 320A 4P 36KA ATS-1no. 320A 4P MCCB (36kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.3200/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 320A 4P AL Busbars: (36kA),1Sec Outgoing : 32A 4P MCCB TM based O/C & S/C Release (25kA) -20 nos. C.T.32/5A, CLASS 0.5 10VA- 20 set
VENTILATION PANEL RIGHT WING
Incomer 320A 4P 36KA ATS-1no. 320A 4P MCCB (36kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.320/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 320A 4P CU Busbars: (36kA),1Sec Outgoing : 32A 4P MCCB TM based O/C & S/C Release (25kA) -17 nos. C.T.32/5A, CLASS 0.5 10VA- 17 set
LIFT PANEL LEFT & RIGHT WING
Incomer 200A 4P 36KA ATS-1no. 200A 4P MCCB (36kA) TM Based O/C, S/C & E/F Release-1No RYB on, off trip indication lamp -1 set. C.T.200/5A, CLASS 0.5 10VA- 1set. Type-2 SPD 36KA-1 no Multi Function Meter with RS 485 -1 no. On, off indication lamp - 2 sets. Busbars: 200A 4P CU Busbars: (36kA),1Sec Outgoing : 63A 4P MCCB TM based O/C & S/C Release (25kA) -8 nos. C.T.63/5A, CLASS 0.5 10VA- 8 set
Supply, Installation, testing & Commissioning of following MCB/ MCCB breaker with O/L, S/C & E/F protections in suitable sheet steel enclosure for local isolation with Phase LED lamp & Breaker ON/OFF/Trip (R/Y/B/R/G). Note: For 630A rating breaker shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.
100A 25kA 4P MCCB (INDOOR IP42)
63A 25kA 4P MCCB (INDOOR IP42)
Supply, Installation, testing & Commissioning of following TP/4P MCB/RCBO 10kA breaker in suitable sheet steel enclosure for local isolation with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.
32A TP MCB (INDOOR IP 42 )
63A TP MCB (INDOOR IP 42 )
RISING MAIN
Supply, Installation, Testing and Commissioning of 2500 A, 4P 65kA 1 sec Copper Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP55 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos Copper bus bars , necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos GI strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system, supports etc. as required. The rate shall be included of wall frame assembly, all the supports, angles etc. Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature as per the site location. ( Legrand,C&S,)
END FEED UNIT : Supplying, installation, testing & commisioning of 2500A 65kA 4P EDO ACB with O/C, S/C, E/F release SC for 1 sec End Feed Unit for the existing Sandwich type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with ACB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required. Separate cable alley need to be considered for cable termination considering the cable bending radius.
Tap off Boxes
Supplying, installation, testing & commisioning of Tap-off boxes with 250A, 36kA 4P MP based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.
Supplying, installation, testing & commisioning of Tap-off boxes with 320A, 36kA 4P MP based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.
Supplying, installation, testing & commisioning of Tap-off boxes with 200A, 36kA 4P TM based MCCB with O/L,S/C releases. Separate cable alley need to be considered for cable termination considering the cable bending radius.
BUSDUCTS
Design, Engineering, Manufacture, Supply, Testing , Commisioning of 4000 Amps 4P 65kA Sandwitch type Copper BUSDUCT with integral earth including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment at site, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor,minor civil works, interconnection of shipping sections, installation of bus duct support (fixing to wall/column/ceiling or steel structures) and aligning, levelling, grouting, testing, and calibration of equipment, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-charge along with its necessary accessories. The bus duct shall be with IP 55 without any additional enclosure. The busduct should have two seperate runs of external earth busbar which should have half the size of phase busbar and suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. horizontal and Vertical bends, busbar trunking fittings (elbow, tees, End (Cable) feed Box, end covers, horizontal fixing devices, required Phase crioss over chambers,Terminal box at switchgear end including seal off bushing and Aluminium flexible and required accessories, Hot dip galvanised steel Bus duct support required as per site requirement. etc. The horizontal runs of busbar trunking system shall be supported by hangers at every 2 metre. Vertical runs of busbar trunking system shall be supported by hangers not more than 4m apart. Outdoor external canopy is required only for out door busdcuts as required as per site conditions. (From Transformer to Main Panel & DG to DG sync paenls & DG Sync panel to Main Panel ( Legrand,C&S,)
Design, Engineering, Manufacture, Supply, Testing , Commisioning of 2000Amps 4P 65kA Sandwitch type Copper BUSDUCT with integral earth including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment at site, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor,minor civil works, interconnection of shipping sections, installation of bus duct support (fixing to wall/column/ceiling or steel structures) and aligning, levelling, grouting, testing, and calibration of equipment, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-charge along with its necessary accessories. The bus duct shall be with IP 55 without any additional enclosure. The busduct should have two seperate runs of external earth busbar which should have half the size of phase busbar and suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. horizontal and Vertical bends, busbar trunking fittings (elbow, tees, End (Cable) feed Box, end covers, horizontal fixing devices, required Phase crioss over chambers,Terminal box at switchgear end including seal off bushing and Aluminium flexible and required accessories, Hot dip galvanised steel Bus duct support required as per site requirement. etc. The horizontal runs of busbar trunking system shall be supported by hangers at every 2 metre. Vertical runs of busbar trunking system shall be supported by hangers not more than 4m apart. Outdoor external canopy is required only for out door busdcuts as required as per site conditions. (From Main Panel to APFC panel) . ( Legrand,C&S,)
MCB DISTRIBUTION BOARDS
Supply, Installation, Testing and Commissioning of MCCB/ MCB Distribution board as per approved installation dwgs. Wall mounted MCCB/ MCB DBs with MS wire way box on top / bottom & on sides. MCBs shall be rated for 10kA with current limiting feature. Dummy ways to be covered with blank plates. All out going ways shall be labelled & laminated. Enclosure:1.2mm CRCA Sheet Steel, Powder Coated Door : Double Door Protection : IP 42 for Indoor / IP55 for out door Cable Entry : Top & Bottom Fixing Support - Indoor required clamps / Outdoor with required MS supports of Operating height at 1.2 mtr For UPS distribution RCBO`s shall be harmonic resistant (HI/SI type) Bus bar : Shall be tinned Copper and 200% rating for UPS DB Neutral Link MCB's : 10kA 'C' Curve for Lighting, Emergency Lighting & Raw power, 10kA 'D' Curve for UPS Power Distribution Note: 1) Separate Earth bus/Neutral bus for each phase 2) Each Circuit shall have yellow ferrules with circuit number 3) Accessories required for installation of DB's on Wall/Column/Gyp Board shall be considered 4) DB's shall be covered with powder coated (paint should match with DB Color) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items 5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB door 6) Safe shroud for Neutral link shall be provided
UPS DB Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO+40A DP MCB - 3Nos Outgoings - 16A SP MCB 'D' Curve - 24Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
Kitchen VTPN DB Supply, Installation, Testing and Commissioning of Three phase, 16 Way VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for KITCHEN VTPN DB Incomer - 125A 4P MCCB - 1 No Outgoings - 63A TP MCB - 4 Nos Outgoings - 40A TP MCB - 8 Nos Outgoings - 16A SP MCB - 12Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
VTPN Power DB(Common & Electrical) Supply, Installation, Testing and Commissioning of Three phase, 6 Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for VTPN DB With Cables Adapter BOX -2 Nos Incomer - 63A 4P MCB+ 63A 4P RCCB 100mA - 1 No Outgoings - 32A TP MCB - 3 Nos Outgoings - 32A SP MCB - 9 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
Cafe Area VTPN Power DB Supply, Installation, Testing and Commissioning of Three phase, 8 Way VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for Cafe Area VTPN DB Incomer - 125A 4P MCCB - 1 No Outgoings - 40A TP MCB - 4 Nos Outgoings - 16A SP MCB - 12 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
VTPN Power DB(LIFT DB) Supply, Installation, Testing and Commissioning of Three phase, 4 Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for Lift VTPN DB With Cables Adapter BOX -2 Nos Incomer - 63A 4P MCB+63A 4P RCCB 100mA - 1 No Outgoings - 40A TP MCB - 1 Nos Outgoings - 32A TP MCB - 2 Nos Outgoings - 25A TP MCB - 1 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
SPN DB -2(LIGHTING) Supply, Installation, Testing and Commissioning of Single phase, compartmentalised 8 way SPNDB Single door type, IP 42 powder coated comprising of "C" curve MCB's for DB. Phase Incomer - 25A 30mA DP RCBO - 1Nos Outgoings - 6/10A SP MCB - 6 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.
VTPN Power DB-1 Supply, Installation, Testing and Commissioning of Three phase, 6Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for VTPN DB Incomer - 63A 4P MCB+63A 4P RCCB 100mA - 1 No Outgoings - 32A SP MCB - 6 Nos Outgoings - 32A TP MCB - 2 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
VTPN Power DB-2 Supply, Installation, Testing and Commissioning of Three phase, 6Way VTPN MCB DB Double door type, IP 42 powder coated comprising of "D" curve MCB's for VTPN DB Incomer - 40A 4P MCB+40A 4P RCCB 100mA - 1 No Outgoings - 32A SP MCB - 6 Nos Outgoings - 32A TP MCB - 2 Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions
LT POWER CABLES
Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of XLPE insulated PVC sheathed,FRLSH, Aluminium/Copper conductor armoured/Unarmoured power/control cable of 1.1 KV grade conforming to IS amended upto date and as per specifications.All cables shall be tagged. Cables shall be laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. The Quantities given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work.
3.5 C X 300 sqmm A2XFY
3.5 C X 240 sqmm A2XFY
3.5 C X 185 sqmm A2XFY
3.5 C X 50 sqmm A2XFY
3.5 C X 70 sqmm A2XFY
3.5C X 25 sqmm A2XFY
4CX4sq.mm 2XWY
4RX10sq.mm ZH.FRLS.CU. WIRE
4RX6sq.mm ZH.FRLS.CU. WIRE
1C X 16 sqmm Copper flexible cable
1C X 10 sqmm Copper flexible cable
1C X 6 sqmm Copper flexible cable
1C X 240 sqmm Copper flexible cable
3C X 4 sqmm Copper flexible cable
3C X 6 sqmm Copper flexible cable
3C X 70 sqmm 2XWY
3CX16sq.mm 2XWY
3CX25sq.mm 2XWY
4C X 16 sqmm A2XFY
LT CABLES TERMINATIONS
Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression.
3.5 C X 300 sqmm A2XFY
3.5 C X 240 sqmm A2XFY
3.5 C X 185 sqmm A2XFY
3.5 C X 50 sqmm A2XFY
3.5 C X 70 sqmm A2XFY
4C X 25 sqmm A2XFY
4CX4sq.mm 2XWY
4RX10sq.mm ZH.FRLS.CU. WIRE
4RX6sq.mm ZH.FRLS.CU. WIRE
1C X 16 sqmm Copper flexible cable
1C X 10 sqmm Copper flexible cable
1C X 6 sqmm Copper flexible cable
1C X 240 sqmm Copper flexible cable
3C X 4 sqmm Copper flexible cable
3C X 6 sqmm Copper flexible cable
3C X 70 sqmm 2XWY
3CX16sq.mm 2XWY
3CX25sq.mm 2XWY
4C X 16 sqmm A2XFY
LUMINAIRES
Supply,Installation, testing & commissioning of following types of light fixture complete with driver, Mirror optic reflectors, louvers, inter connecting wires, terminals, lamps,connectors etc, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks., rate shall include necessary supporting / suspending hardware.The support requirement shall be as per site requirement.. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Note: Samples should be submitted for light fixture model and Lamp Colour tempature (CCT) for approval of PMC / Employer.
Supply,Installation, testing & commissioning of 20W Recess mounting circular LED downlight luminaire with casted aluminium housing, anti-glare PS diffuser SS springs and energy efficient electronic driver. The aluminium recessed down light also comprises of casted aluminium housing with high quality diffuser for glare-free uniform light distribution and a minimum system efficacy of 110lm/W. The LED chips are mounted in Metal core printed circuit board with thermal paste for better heat dissipation.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120Deg with a color temperature of 5700K CCT and CRI>80. Low Depth Suitable for ceiling wherein depth between True ceiling and False ceiling is constraint, Wide Operating Voltage Operating Voltage:140-270V AC,Safe & Reliable THD<10%, Inbuilt Surge Protection: 4kV Class-I product, IK05,Non Integrated Isolated Driver No Electric Shocks. Protects the output/secondary side from any disturbance on the Input /Primary side ensuring safe operation,Higher Life:50,000 BH, Operating Temperature 0degC to +45degC. Similar to product code : PDLM49208
Supply,Installation, testing & commissioning of 25W BASELIGHT SCANTO PLUS Recess mounted LED luminaire equipped with CRCA powder coating housing, high transmittance diffuser for symmetric light distribution with separate energy efficient non isolated electronic driver. High on Efficacy of 130lm/W with Wide Operating Voltage Operating Voltage: 140-270V AC Safe & Reliable THD<10%, Inbuilt Surge Protection: 3kV Class-I product Non Integrated Non Isolated Driver Protects the output / secondary side from any disturbance on the Input /Primary side ensuring safe operation Higher Life Life: 50,000 BH Operating Temperature 0degC to +45degC, The LED chips are mounted in Metal core printed circuit board with thermal paste for better heat dissipation.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120Deg with a color temperature of 5700K/4000K and CRI>80. Similar to panasonic product code : PBLM21258
Supply,Installation, testing & commissioning of4ft stanalone Suspended slim Linear LED made of extruded Aluminium with white/black powder coaed finish with high efficiency polycarbonate/PS diffuser and Option of Prismatic Diffuser for Low UGR Rating. The fixture construction shall be H-section construction with LED compartment to be independent from the Driver compartment, the access to the driver should be from the top of the luminaire and not through the diffuser and LED tray to avoid any damage to the diffuser and light leakage.The luminaire shall have a width of not more than 50mm(± 2mm), and shall be available in multiple lengths. LED Used shall be SMD type with approx system Lumens 2500 @21W & efficacy 120lm/W,Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K (SDCM<=5), CRI Ra ≥80, PF ≥0.95, THD≤ 10%, an Operating working temp range - 0°C < Ta < 45°C & operating Voltage Range of 140-270 V AC having Class - I protection & serviceability of Class B. Minimum Internal Surge Protection 3.5kV. Current Ripple necessarily <5%. Luminaire with Ingress & IK protection Rating of of IP20 & IK02.The driver shall be compliant to IEC61347-2-13, IEC62384 & IEC6100-3-2. The driver & Luminaire shall be BIS registered. The driver shall be designed for continuous operation of minimum 12-15Hrs a day. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires and must be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab in India to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer. The manufacturer shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer. Similar to Signify (Philips) Cat No. SP780 H LED25S-6500 PSU W5L112 OD S1 WH
Supply,Installation, testing & commissioning of 8ft stanalone Suspended slim Linear LED made of extruded Aluminium with white/black powder coaed finish with high efficiency polycarbonate/PS diffuser and Option of Prismatic Diffuser for Low UGR Rating. The fixture construction shall be H-section construction with LED compartment to be independent from the Driver compartment, the access to the driver should be from the top of the luminaire and not through the diffuser and LED tray to avoid any damage to the diffuser and light leakage.The luminaire shall have a width of not more than 50mm(± 2mm), and shall be available in multiple lengths. LED Used shall be SMD type with approx system Lumens 4400 @37W & efficacy 120lm/W,Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 4000K (SDCM<=5), CRI Ra ≥80, PF ≥0.95, THD≤ 10%, an Operating working temp range - 0°C < Ta < 45°C & operating Voltage Range of 140-270 V AC having Class - I protection & serviceability of Class B. Minimum Internal Surge Protection 3.5kV. Current Ripple necessarily <5%. Luminaire with Ingress & IK protection Rating of of IP20 & IK02.The driver shall be compliant to IEC61347-2-13, IEC62384 & IEC6100-3-2. The driver & Luminaire shall be BIS registered. The driver shall be designed for continuous operation of minimum 12-15Hrs a day. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires and must be EMI/EMC compliant. Luminaire manufacturer must have In-house NABL accredited lab in India to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer. The manufacturer shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer. Similar to Signify (Philips) Cat No. SP780 H LED44S-4000 PSU W5L224 OD S1 WH
Supply,Installation, testing & commissioning of 2' LED batten (Mirror light) with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be 12W with system lumens of 1200 lumens and system efficacy of 100 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 20000burning hours, Ambient temp-0 to 35DegC, Driver efficiency>85%, THD<30%, Power factor>0.9. Philips Cat Ref: BN021 LED12S 6500 PSU GR
IP65 LED bulkhead luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather polycarbonate housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with pressure die cast aluminium housing. The system wattage shall be < 15W with system lumens of > 1200 lumens and system efficacy of > 80 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency>85%, THD<10%, Power factor>B231 .
Supply of IP20 LED recess mounted deep recessed high efficacy downlighter with minimum system lumen output of 3600lm with >115lm/W system efficacy . The product shall be with white reflector options, with beam angle of 80 deg (White reflector). The luminaire shall have life of 50000hrs @L70B50, CRI ≥80, SDCM 5, THD ≤10%, pf ≥0.9, CCT - 5700K. The product shall have internal surge protection of 3.5kV, with operating temperature range of 0 to 45 deg C and operating voltage range of 140-270V. The product shall have 105mm cutoutdia. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Similar to Signify Cat No. DN394B LED36S/857 D200 PSU WH IN
Supply,Installation, testing & commissioning of LED Decorative Light-1
Switching PIR SensorsCeiling Mount 360 degree. Micro Detection - High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) and . Current Capacity 10A. Digital Remote IR based Commissioning with hand held programmer for following Programmable features: OFF delay time 10 Sec - 96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override luminary ON/OFF status using hand held remote control.
*Supply of 12W/m 5000mm LED flexible IP20 strip with aluminium profile for special application should be designed to provide undisrupted lighting for dusty and humid indoor application. The LED should be with silicon housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The system wattage shall be 12W with system lumens of 1200 lumens and system efficacy of >100 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of > 100lm/W, Colour Temperature-2700K with LED binning of SDCM<3 as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED strip as per L70 > 50000burning hours, Ambient temp-0 to 35DegC, Driver efficiency>85%, THD<10%, Power factor>0.9, Constant Current - Constant Voltage LED Driver Voltage range 140-270V AC, potted driver. LED strip should be with minimum cut length of 10cm and also provision to joint two strips. LED strip should be with IP20, IK03 protection, also BIS & CB certified Similar to Philips Cat no :LS170S LED12 827 IP20 L5000 G2
Supply,Installation, testing & commissioning of LED Decorative Light-2
Supply,Installation, testing & commissioning of LED Flood Standing Light-60w
Flexible Strip luminaire with LED system power: 12W/m, luminous flux of luminaire 540lm/m,colour temperature of 3000K, beam angle of 160°, CRI>80, 230Vconstant current driver, 70% of luminous flux after50,000 operating hours; energy effcient LEDs, direct lightemission, support profile in powder coated white, Electroniccontrol gear, Protection class I, IP68,L=1000mm, B = 16mm, H = 12mm. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition.
Integral, SMD LED, IP40, 36/40W Surface Mounted LED Batten with System efficacy of more than 110 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. including Suspention rod from Ceiling
Supply,Installation, testing & commissioning of LED12W Recess mounting circular LED downlight luminaire with casted aluminium housing, anti-glare PS diffuser SS springs and energy efficient electronic driver. The aluminium recessed down light also comprises of casted aluminium housing with high quality diffuser for glare-free uniform light distribution and a minimum system efficacy of 110lm/W. The LED chips are mounted in Metal core printed circuit board with thermal paste for better heat dissipation.The luminaire shall have a rated system life of 50,000BH @ L70. The luminare should have beam angle of 120Deg with a color temperature of 5700K CCT and CRI>80. Low Depth Suitable for ceiling wherein depth between True ceiling and False ceiling is constraint, Wide Operating Voltage Operating Voltage:140-270V AC,Safe & Reliable THD<10%, Inbuilt Surge Protection: 4kV Class-I product, IK05,Non Integrated Isolated Driver No Electric Shocks. Protects the output/secondary side from any disturbance on the Input /Primary side ensuring safe operation,Higher Life:50,000 BH, Operating Temperature 0degC to +45degC. Similar to product code : PDLM49128
Supply,Installation, testing & commissioning of SINGLE ARM DECORATIVE BRACKET OH -750MM, H-1000MM PU Grey Paint (OPO-GRY-POLBKTS04SA7501M) with POLE 6.0M PU Grey Paint OPO-GRY-POLBKOD11476600M , Earthing studs, TPN loop-in and loop-out smart pack junction box with MCB & necessary 50mm dia GI pipes bent to shape for cable entry/ exit and including 3C x 2.5 sq.mm PVC multistranded copper wire between terminal block and luminaire and with coil earthing using 80 turns of 8 SWG GI. wire as per standards. (complete including all civil work for foundation etc) & Stand terminals as per specifications with one 10A (10kA) SP MCB and 20A TPN terminals. Supply and erection of RCC Civil foundation & "U" Bolts & Nuts.
Supply,Installation, testing & commissioning of DOUBLE ARM DECORATIVE BRACKET OH -750MM, H-1000MM PU Grey Paint PU Grey Paint (OPO-GRY-POLBKTS04DA7501M) with POLE 6.0M PU Grey Paint OPO-GRY-POLBKOD11476600M , Earthing studs, TPN loop-in and loop-out smart pack junction box with MCB & necessary 50mm dia GI pipes bent to shape for cable entry/ exit and including 3C x 2.5 sq.mm PVC multistranded copper wire between terminal block and luminaire and with coil earthing using 80 turns of 8 SWG GI. wire as per standards. (complete including all civil work for foundation etc) & Stand terminals as per specifications with one 10A (10kA) SP MCB and 20A TPN terminals. Supply and erection of RCC Civil foundation & "U" Bolts & Nuts.
Supply,Installation, testing & commissioning of SINGLE ARM DECORATIVE BRACKET PU Grey Paint (OPO-GRY-BKTS07SAD420900M) with POLE 6.0M PU Grey Paint OPO-GRY-POLBKOD11476600M , Earthing studs, TPN loop-in and loop-out smart pack junction box with MCB & necessary 50mm dia GI pipes bent to shape for cable entry/ exit and including 3C x 2.5 sq.mm PVC multistranded copper wire between terminal block and luminaire and with coil earthing using 80 turns of 8 SWG GI. wire as per standards. (complete including all civil work for foundation etc) & Stand terminals as per specifications with one 10A (10kA) SP MCB and 20A TPN terminals. Supply and erection of RCC Civil foundation & "U" Bolts & Nuts.
Supply,Installation, testing & commissioning of DOUBLE ARM BRACKET PU Grey Paint PU Grey Paint (OPO-GRY-BKTS07DAD420900M) with POLE 6.0M PU Grey Paint OPO-GRY-POLBKOD11476600M , Earthing studs, TPN loop-in and loop-out smart pack junction box with MCB & necessary 50mm dia GI pipes bent to shape for cable entry/ exit and including 3C x 2.5 sq.mm PVC multistranded copper wire between terminal block and luminaire and with coil earthing using 80 turns of 8 SWG GI. wire as per standards. (complete including all civil work for foundation etc) & Stand terminals as per specifications with one 10A (10kA) SP MCB and 20A TPN terminals. Supply and erection of RCC Civil foundation & "U" Bolts & Nuts.
Supply,Installation, testing & commissioning of LED 100W low bay IP65 FLOOD LIGHT EQUIVALENT TO PHILIPS
Supplying and fixing of LED Aviation light, suitable for upto 70 m height, epoxy flame orange painted die-cast aluminum alloy housing, with polycarbonate glass, bird spike including supplying and laying of 3 core weather proof PVC insulated and PVC sheathed copper conductor cable from ground.
4 feet 36W Well glass Falme proof LED emergency light with required fixing accessories as required & Colour Temperature-6500K, CRI > 80, Life of LED as per L70 > 50000burning hours, , Driver efficiency>85%, THD<10%, Power factor>0.95, Driver Voltage range 140-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, high voltage cutoff & auto restart @320V, phase to phase 440V protection upto 8hrs, Electrical Safety with Class 1 Insulation, Constant Current - Constant Voltage LED Driver with APFC Construction, Driver shall be compatible for auto cut off and restart with deviation to operating voltage also the ripple shall be less 5%. (TYPE-10)
Supplying of 60W Decorative street light with architectural pole and arm Luminaire made out of Spun Aluminium with PU Grey Paint and PC Lens and Transparent Acrylic Diffuser The Luminaire shall have following specifications as System Efficacy ≥ 100 lm/W, CRI ≥ 80, Asymmetric distribution Operating Voltage 220V-240V Colour Temperature Range : 6500K, with High performance Constant Current Driver suitable for operation on 230V 50Hz AC, Surge Protection ±5.0KV, ATHD <10%, Over Voltage Protection Cut Off @ 330V±5%, Life Span >50000 Hrs (Ta=25℃ @L70), Ingress ProtectionIP 65
Supplying of 60W street light, Luminaire made out of Aluminium Die Cast with Powder Coating With Lens and Toughened Glass, The Luminaire shall have following specifications as System Efficacy ≥ 100 lm/W, CRI ≥ 70, Asymmetric distribution Operating Voltage 240V Colour Temperature Range : 5700K, with High performance Constant Current Driver suitable for operation on 230V 50Hz AC, Surge Protection ±4.0KV external Upto 10KV with SPD, ATHD <10%, Withstand upto 440V/AC for 4 Hrs, Life Span >50000 Hrs (Ta=25℃ @L70), Ingress ProtectionIP 66, Impact Protection IK 06
Supply of surface mounted, exterior-rated LED linearstrip light with 57W / 5m roll with 1100 lm/m luminaire with all the necessary accesories as below that is designed for grazing architectural lighting applications waterproof and anti-dust LED strips. It shall be sealed with Glue-injected with polyurethane (PU). SDCM<5 and 3000K. Robust Design & IP68 rating for outdoor use. Luminaire has input voltage 24VDC, Operating temperature -40°C to 50°C, IP68 & IK06 protection, Lumen maintenance of 30,000 hrs @ L50 at 35°C. Standards : EN60598,EN62471,EN62493+IEC62778, CE-EMC. Similar to Philips Cat Ref No: BGC301 1100LM 3000K L5000 . BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition. with proposer instalation as per site condtions. for Out side elevations The LED driver shall be a high-efficiency, constant-voltage DC type with a minimum rated output power of 150 watts
Translucent Ceiling - Fabric, Profile Including Installation. Stretch Material - Continent of Origin - Asia Thickness of Membrane - 0.18mm Weight - 250 -300 gsm +/- 2% The width of membranes (without seams) stretched - 500 cm unstretched, 514 cm stretched. Hairline seam afterwards. % of light transmission - 75.00% Fire Rating - BS1D0 in accordance with EN 13501-1. Warranty - 10 years against Welding Joints VOC Rating - ROHS +REACH Compliant Installation system - PVC harpoon welded with high frequency on the perimeter of the membrane according to shape and size. Aluminium profiles with Osram 24V Rigid Block Led 3000K, with JST 2Pin Female and Male Connections Plug with Red Black Terminal Connector Wire Cable & lighting Screw 160 Degree Best Viewing Angle with PMMA Lens ROHS Certified Make: Orbit+ Including Suitable wooden supports for the Light fiitngs (Size Of the Lumunire is 10Ft X10ft- 2Nos)
Aesthetically designed IP65 LED Bollard luminaire comprises of galvanised extruded mild steel pipe housing with opal polycarbonate diffuser and aluminium mounting base.System Efficacy of 90 lm/W,Robust Design Light Distribution,Safe & Reliable High Surge Protection: 4KV Power Factor >0.95,Wide Opeting Voltage Operating Voltage: 140-270V AC,Weather Proof IP65 Protection,Long Life Specially designed heat sink for long life of 50,000 BH , similar to product code PBDM03108
Supply, Installation, Testing & Commissioning of LED COB Type Surface/Suspended Downlighter with a nominal system lumen output of 1500 lumens (1100Lm/W) and Luminaire wattage should not exceed 15W Also Safe operating voltage 140-270V AC. Power factor should be >0.95 & THD should be <10% & CRI>80. Color temperature – 5700K. SPD Should be 2.5KV Surge Protection. Dia : 80MM Height ; 170MM And its should be Extruded Al.Housing.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model No : SP320P LED15S 5700 PSU DIA80 WH
Supplying, erecting, connecting and commissioning of LED light fitting of with necessary standard accessories Continuous Profile based lighting using Extruded aluminium deep profile of 17mm width with frosted diffuser. 24V LED short pitch strip light having power of 12W and 1200lm per metre to be used inside profile neatly pasted using high quality self-adhesive tape of 3M. 24V non integral driver to be used for the LED strip light. The profile and LED Strip should be cuttable as per site requirements. also. ( 5mtrs strips with ballast)The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site condition
Supply, Installation, Testing and Commisioining of 600mm Triangle shape Decorative type fittings. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs4500.
Supply, Installation, Testing and Commisioining of Decorative type fittings. Type-1 The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs4500.
Supply, Installation, Testing and Commisioining of Decorative type fittings. Type-2 The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs8500.
Supply, Installation, Testing and Commisioining of wall Decorative type fittings. Type-1 The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs11500.
Supply, Installation, Testing and Commisioining of wall Decorative type fittings. Type-2 The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs13500.
Supply, Installation, Testing and Commisioining of floor Decorative type fittings. Type-2 The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions approved by archeitech/consultant.Approx. Value of the fittings is Rs14500.
Supply, Installation, Testing and Commisioining of instalation of 1200mm Sweep BLDC celing fan and along with Suitable BLDC 2module Regulater ( Havells & Panasonic) all accesaries
WIRING FOR LUMINAIRES
CIRCUIT MAIN
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge.
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed medium class PVC conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Wire`s colour coding should be as per PMC/Employer in charge.
Supply, Laying, Testing and Commissioning of Wiring for submains along with earth wire with 2R 1.5Sq.mm + 1R 1.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge.
LIGHT POINTS WIRING Supply, installation, Testing and Commissioning of switch control point wiring as describe in below line items . Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge. Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be covered under relavant item) For concealed conduiting, wall chasing and finishing need to be considered in the quote.
PRIMARY POINTS Supply, installation, Testing and Commissioning of point wiring with Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End
SECONDARY POINTS Supply, installation, Testing and Commissioning of Group controlled point wiring with 2Rx1.5Sq.mm (Phase&Neutral) + 1Rx1.5Sq.mm (Earth) FRLS PVC insulated 1100V Copper wires in suitable surface/receesed Steel conduit including all accessories such as bends, junction boxes,ceiling roses etc., complete. Light outlet from existing primary point with 20mm dia MS .Consider Average Length foreach point as- 5Mtrs. (From Primary points to other Light Points) .
Elevator Shaft Lighting for Service Elevators (Ground to Terrace) comprising of following items mentioned below & Consider surface mounted conduiting with required all fixing accessories as required as per site conditions. Consider surface mounted conduiting. The rates & quantity of below mentioned items shall be considered from GF to 9 th Floors for 1no Lift. comprising of : - a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit light using 2 Nos 6A 2 way switches. e. Wiring for sets of 6A switched & socket outlets. wire for lighting circuit : 3 runs of 1.5 sq.mm wire for power circuit : 3 runs of 4.0 sq.mm Conduit: 20mm steel Conduit for lighting & 25 mm dia steel Conduit for Power
WIRING FOR POWER
MAIN POWER WIRING
Supply, Laying, Testing and Commisiosning of 2R 6Sqmm + 1R 6 Sq..mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.
Supply, Laying, Testing and Commisiosning of 2R 4Sqmm + 1R 4Sq.mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 2.5Sq.mm PVC insulated FRLS multistrand copper wire in MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.
SWITCHES, SOCKETS & ACCESSORIES 'Supply, fixing, testing and commissioning of Modular Switch & Socket combination in suitable modular box with front plates ,blank plates,acessories wherever required and Industrial Sockets with MCB in Open/Recessed system with necessary earthing arrangements.The necessary civil works shall be done for connected works and no extra payment will be made for the same. (On non availability of specified rating industrial sockets, immediate higher rating socket must be provided with given control breakers). 'All modular type sockets shall be shuttered type with earth terminal. All industrial sockets should be provided with suitable plug. All metal box should be earthed as required & shall be covered with removable film coat to protect from scratches and paint.
Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 2nos.6A two module 3 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End ( UPS Power)
Supply and fixing of 16A Flush type Wall 3pin Socket 16A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
1No 16A 240V 3 pin single phase modular 3pin socket with plug top controlled by 16A DP MCB in a suitable size MS enclosure fixed in open / recessed system.
1No. Of 32A 5 pin Three phase Industrial type socket with plug top controlled by 32A 4P MCB in a suitable size MS enclosure fixed in open / recessed system.
Supply and installation of 1No. Of 32A 3 pin single phase Industrial type socket with plug top controlled by 32A DP MCB (D-curve) in a suitable size enclosure fixed in open / recessed system.
Supplying and fixing 1 or 2 Module (75mmX75mm) size GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 4 Module (125mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 6 Module (200mmX75mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 8 Module (125mmX125mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 12Module (200mmX150mm) size GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supply, installation, connection, testing and commissioning of following size minimum IP-67 Water tight Junction box along with Terminal & including accessories for junction box like PVC grommet ,Entery Thread Metric,Lock Nuts etc. 130X180X77mm
Supply, Fixing, Testing and Commisiosning of 1nos 6A+with 2A USB port moulded front plate socket and 1 no 10A switch with moulded front plate GI anodised enclosure and other associated accessories in the work station as required as per the site conditions.(for UPS POWER)
Supply, Fixing, Testing and Commisiosning of 1 no 16/6A water/spalsh proof switched socket with moulded front plate GI anodised enclosure and other associated accessories as per the site conditions.(for RAW POWER)
LADDER CABLE TRAYS
Supply & Installation of hot dip GI ladder type cable tray (galvanisation thickness not less than 80 microns) with all accessories like coupler,including supply and fixing of suitable supports (Including Anchor fastners) GI nut bolts,bend, tee, reducer etc as per specification and drawing with all necessary accessories as required for complete installation shall be included and complete with all required hardware, Contractor to provide shop drawing for cable tray : (Quoted cost shall include the cost towards cable tray supporting systems.) The support shall be as per site requirement.
450 mm width X 100 mm depth X 2 mm thicknessv GI ladder type cable tray
600 mm width X 100 mm depth X 2 mm thickness GI ladder type cable tray
750 mm width X 100 mm depth X 2 mm thickness GI ladder type cable tray
1000 mm width X 110 mm depth X 2 mm thickness GI ladder type cable tray
PERFORATED CABLE TRAYS
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
150 mm width X 75 mm depth X 1.6 mm thickness
300 mm width X 100 mm depth X 1.6 mm thickness
450 mm width X 100 mm depth X 2.0 mm thickness
600 mm width X 100 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 100 mm depth X 2.0 mm thickness
Supplying and installing following size of BOX Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 100 mm depth X 1.6 mm thickness
FLOOR RACEWAYS
Supply and installation of pre-galvalized (galvanisation thickness not less than 80 microns) floor raceways made from 2.0mm thick G.I. sheet in following size for industrial power outlet wiring, ncluding supply and fixing of suitable supports (Including Anchor fastners) tele, data, etc complete with suitable knockouts, junction box, tap off points, reducer, 3mm /2.5mm/2 mm thick removable top cover and cable holding arrangement : (Quoted cost shall include the cost towards raceway supporting systems.) Raceway installed above false ceiling/floor shall include necessary mounting supports, junction boxes and accessories to fix it firmly to the ground/ ceiling. The raceways shall be fixed to the floor with GI/MS (25mm x 3mm) strips so that there is no movement of the channels when civil work (pouring of cement concrete) is being done. Rate includes necessary floor cutting and chipping with machine of minimum 50mm depth, removal of debris out of site and neatly finished with M15 grade concrete up to the finished floor level. Race ways to be covered with Chicken mesh before concreting. Curing compound to be applied after initial setting of the concrete.All edges, cut faces shall be free of burrs & shall be smooth. The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire with screws so that earth is continuous. Jointing of the race ways to be done with welding.
FLOOR JUNCTION BOXES
150 x 150 x 50mm Size
250 x 250 x 50mm Size
FLOOR RACEWAYS
100 x 45mm Size with one compartments and 2mm thick top cover.(DATA)
CONDUITS /ACCESSORIES
Supply and fixing of heavy duty PVC& steel conduit of various dia., exposed or concealed, with all accessories, Wall chasing, finishing, fish wire, junction boxes etc., as directed by the project incharge officers and the brand should got approval. (Exposed Conduiting - MS & Concealed Conduiting - PVC HMS )
Supply and Fixing of 32mm PVC Conduits
Supply and Fixing of 25mm PVC Conduits
Supply and Fixing of 20mm MS Conduits
Supply and Fixing of 25mm MS Conduits
Supply and Fixing of 32mm MS Conduits
Supply and arranging for Temporary Power Supply for Electrical power distribution on site for lighting , Power and other contract agencies at site including sufficiaent no of tube light fittings, sifficient no. of plug points with plug tops with adequate distribution boards with IP Rating and all other necessory safety devices like elcb, etc., to ensure safe and continued supply at site. up to end of the project. as directed by the departmental officers and the brand should be got approval.
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure including all accessories i.e. bends, reducers, flanges as required. of following sizes
50 mm OD with 3.6 mm wall
100 mm OD with 5.5 mm wall
160 mm OD with 7.7 mm wall
SHOP DRAWINGS, INSPECTION AND APPROVALS
Preparation & submission of applications, Liasioning with TNEB for getting Load sanction, service connections all necessary co-ordination upto completion of the project.
Preparation & submission of drawings for CEG approval , Getting the required statutory approval like CEIG, local statutory authorities, etc. for the entire building including all liasoning works, filing necessary applications, submission of forms for approval to the authorities, all required drawings preparation and approval including attending meetings, depositing the fees / other amounts as required for getting the premises / installations, inspected and approved and all other formalities required for getting the approval. All professional charges, liasoning charges & the expenses incurred in this regard shall be borne by the Contractor. Four Sets of paper print of as built drawings& as soft copy of these drawings to be submitted to the clients while completion.
LIGHTNING PROTECTION SYSTEM & STRUCTURAL EARTHING
LIGHTNING PROTECTION LEVEL - III
EARTHING SYSTEM
Supply & Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 100µm. Tested as per IEC 62561-2. CAPE Type: SRC 10 CuB (Article No. 400 010)
Supply and installation of 18 mm copper bonded Solid Steel Round Conductor with minimum coating thickness 70µm as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. CAPE Type No. CBSR 18 (Article No. 400 021)
Installation of Exothermic Welding - Including welding mould and other accessories for welding confirms the requirements of IEEE 837:2014 : T-Joint, X-Joint, L-Joint , Straight joint CAPE Article: 400 880
Supply and installation of Corrosion Bitumen tape for inside soil. CAPE Type: CT5 (Article No. 400 200)
STRUCTURAL DOWN CONDUCTOR
Supply & Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for integrated down conductor. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 100µm. Tested as per IEC 62561-2. CAPE Type: SRC 10 CuB (Article No. 400 010)
Supply & Installation of Multipurpose Bonding clamp for interconnecting Ø10mm copper bonded steel Round Conductor with reinforcement rebar inside the concrete at every 3 mtr to meet the requirements of IS/IEC 62305. CAPE Type: MCBC 101832 (Article No. 410 506)
Supply & Installation of Stainless Steel Straight Connector of integrated down conductor at every 4 mtr and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: SC 8-10 (Article No. 400 210)
Supply and installation of Earthing stud & suitable Clamp of dimension 69 x 69 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. CAPE Type No. ES 1 RA1 ( Article No. 401 510 )
AIR TERMINATION SYSTEM
Supply and installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in down conductor system . Cross sectional area of conductor should be 50 mm².Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL (Article No. 400 008)
Supply & Installation of Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor. CAPE Type: PCH 8-L (Article No. 440 006)
Supply and installation of Nylon roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr. CAPE Type: MBPCH 8-L(Article No. 440 008)
Supply & Installation of Stainless Steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor at cross/Tee junction. Test Parameter a) Mechanical Load b) Electrical Test c) ENvironmental Test .Tested for IEC 62561-1 CAPE Type: MPC 8-10 SS (Article No. 420 022)
Supply & Installation of Expansion joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations.Expansion joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor. Test Parameter: Electrical Resistivity Test-0.036 µΩm Salt Spray Test - No Sign of Corrosion .Tested as per IEC 62561-1 CAPE Type: EPC 8 (Article No. 401 209)
Supply & Installation of Aluminium Straight conductor connector for interconnecting 8mm dia Aluminium conductor to meets the requirement of IS/IEC 62305.Tested for Electrical, Mechanical and chemical as per IEC 62561. CAPE Type: CJ 8 (Article No. 401 211)
Supply & Installation of air termination rod of 3mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories . Test Parameter for 3 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist Tested as per IEC 62561-2.Test Parametrer for Wall clamp a) Mechanical load as per IEC 62561-1 CAPE Type: VATW3 (Article No. 405 420)
Supply & Installation of air termination rod of 3 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 3 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist .Tested as per IEC 62561-2. CAPE Type: VATF3 (Article No. 401 430)
Supply & Installation of air termination rod of 6 mtr length of material AlMgSi of diametre ø 40/16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 6 mtr Vertical Air terminal a)ELectrical Resistivity b) Tensile Strength .Tested as per IEC 62561-2. CAPE Type: VATF6 (Article No. 401 470)
Supply & Installation of Stainless steel folded clamp for fixing Aluminium conductor on the metal structure to meet the requirement of IS/IEC - 62305 CAPE Type: FSCH 14-8 (Article No: 440 011)
Supply and installation of stainless steel Earth stud of dimension 69 x 69 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and humidity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. (for interconnecting Air termination and structral down conductors) Cape Type No. ES 1 RA1( Article No. 401 510 )
Supply and installation of CAPE make connecting point made of stainless steel for terminating 10mm copper conductor. CAPE Type: CPES 10 (Article: 400 504)
TN-S PME EARTHING
Supply & Installation of 18 mm dia copper bonded Solid Steel Round Conductor with minimum coating thickness 70µm for grid earthing system & integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. CAPE Type: CBSR 18 (Article No. 400 021)
Supply & Installation of Rust resistant non corossive 10 mm dia Copper Bonded Solid Steel round conductor used for grid earthing system & integrated down conductor. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 100µm. Tested as per IEC 62561-2. CAPE Type: SRC 10 CuB (Article No. 400 010)
Supply & Installation of Multipurpose Bonding Clamp for interconnecting Round Conductor with reinforcement rebar inside the concrete at every 3 mtr to meet the requirements of IS/IEC 62305. CAPE Type: MCBC 101832 (Article No. 410 506)
Supply & Installation of Diagonal Clamp for interconnecting 10 mm dia Round Conductor with reinforcement rebar inside the concrete at every 3 mtr to meet the requirements of IS/IEC 62305. CAPE Type: DCMS (Article No. 401 507)
Supply & Installation of 10mm dia Stainless Steel Straight Connector for integrated down conductor at every 4 mtr and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: SC 8-10 (Article No. 400 210)
Supply & Installation of 18mm dia stainless Steel Straight Connector at every 5 Mtr of integrated down conductor and should be tested for electrical resistivity, mechanical load to meet the requirement for IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: SC 16-18 (Article No. 402 210)
Supply & Installation of suitable Steel Cross Connector for 10 mm dia round conductor at Tee and Cross Junction to meet the requirement for IS/IEC-62305. Cape Type: CCMS 8-10 ( Article No. 400 205)
Supply & Installation of suitable Steel Cross Connector for 18 mm dia round conductor inside concrete and should be tested for electrical resistivity and mechanical load to meet the requirement of IS/IEC - 62305 and IEC 62561-1&2. CAPE Type: CCMS 16-18 (Article No. 403 206)
Supply & Installation of Stainless Steel Earthing Stud with fixing clamp accessories of dimension 69 x 69 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Cape Type: ES 1 RA1 ( Article No. 401 510 ) Rated Current (CPRI TESTED): Irms- 5.33 KA; Ipeak- 11.14 KA Per sec
Supply & Installation of Stainless Steel Earthing stud with fixing clamp accessories of dimension 99 x 69 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Cape Type: ES 3 RA1 ( Article No. 401 520) Rated Current (CPRI TESTED): Irms- 7.81 KA; Ipeak- 18.88 KA Per sec
Supply & Installation of Cu Earthing stud with fixing clamp accessories of dimension 100 x 70 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Cape Type: ES3CU RA1 Rated Current (CPRI TESTED): Irms- 27 KA per sec; Ipeak- 79 KA per sec
Supply & Installation of Cu Earthing stud with fixing clamp accessories of dimension 150 x 80 mm used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. Cape Type: ES5CU RA1 Rated Current (CPRI TESTED): Irms- 50 KA per sec; Ipeak- 110 KA per sec
LIGHTNING PROTECTION SYSTEM
Supply and installation of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in down conductor system . Cross sectional area of conductor should be 50 mm².Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL (Article No. 400 008)
Supply and installation of Nylon Conductor Holder for side wall for holding 8 mm dia Aluminium alloy round Conductor. CAPE Type: PCH 8-L (Article No. 440 006)
Supply and installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test .Tested as per IEC 62561-1 CAPE Type: CJ 8 (Article No. 401 211)
Supply and installation of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6. CAPE Type No: PRO LER (Article No. 400 999)
Supply and installation of Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1 CAPE Type: TJRRE - G1 (Article No. 404 214)
Supply and installation of stainless steel Earth stud of dimension 69 x 69 mm integrated inside concrete and should be tested for electrical resistivity, salt spray and humidity test & short circuit to meet the requirements of IS/IEC 62305 and IEC 62561-1&2. (for interconnecting Air termination and structral down conductors) Cape Type No. ES 1 RA1( Article No. 401 510 )
Supply and installation of CAPE make connecting point made of stainless steel for terminating 10mm copper conductor. CAPE Type: CPES 10 (Article: 400 504)
Supply & Installation of Rust resistant non corossive 10 mm dia Copper Bonded Steel round conductor used for Earth termination inside the concrete and soil. Test parameter: a) Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec (IS3043/IEEE80); b)Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. c)Tensile Test 290 to 510 N/mm². d)Adhesion no peel or crack & Bend test no seperation of Cu, e)Cu Coating thickness min. 100µm. Tested as per IEC 62561-2. CAPE Type: SRC 10 CuB (Article No. 400 010)
Supply & Installation of Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test .Tested as per IEC 62561-4 CAPE Type: CH 8-10 (Article No. 400 213)
Supply and installation of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 20 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. CAPE Type No. CBR 2010 (Article No. 300 110) Supply and installation of CAPE make earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kg CAPE Type: PROSAN 25 (Article No. 300 832) Supply and installation of CAPE make Earth rod clamp made up of SS Material for terminating cable / flat conductor. CAPE Type: ERC 2025 SS (Article No. 300 464) + CAPE Type: CPES 8 (Article No. 401 504) Supply and installation of CAPE make Earth Chamber Inspection Pit made up of Plastic withstand load of 60kN with the dimention of 290*290*209mm CAPE Type: EC 290 (Article No. 300 852)
EARTHING
Supply & Laying of 75x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 65x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x10mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 40x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x10mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 50x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x3mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 25x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 6 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Laying of 4 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.
Supply & Installation of Busbar of 0.5 Mtr length made out of 50x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with visible glass
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm Cu strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass
Earthing Pits
Supply,installation, testing and commissioning of GI Pipe Electrode Earthing System:Pipe Earth Electrode using 38 mm dia class B GI pipe complete as per IS 3043 with salt, charcoal, brick masonary chamber with heavy duty RCC cover of 450mm x 450mm x 300mm chamber. (Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.
Supply,installation, testing and commissioning of Copper plate Electrode Earthing System:Plate Earth Electrode using 19 mm dia Class B copper plate of size 600 x 600 x 3 mm thick.with heavy duty RCC cover of 450mm x 450mm x 300mm chamber.(Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.
Supply and insallation maintenance free Earthing System comprising of carbon coated (with micron bonding of 100 Microns) 3 Mtrs long earth MS electrode with pipe in pipe technology of 76mm outer dia Dia and 42mm inner dia overall and 25 kgs. of environment friendly backfill compound with suitable clamp and all other required accesroes for its complete commiosing of Earth pit with effective resistance as per Specifications,
Electrostatic Earthing system for tanker grounding. Supply and installation of earthing integrity monitoring system for tanker unloading with all necessary indications , interlockings , alarms , switches and cable entry points. The System shall be in flame proof enclosure with CCOE certification.
UPS & BATTERY
Supply, installation, testing and commissioning of UPS system for consisting of 3KVA UPS with IGBT UPS modules in capacity of capacity of 3 KVA each with necessary BMS compatibility (hardware & software items for third party integration) with MODBUS protocol RS485, Telenet service -communication with LAN for sending mails/ messages in case any tripping or maintenance required with necessary software.
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 3 kVA (Continuous rating) online, modular UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links/wiring for each of above UPS units with 90 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.
Supply, installation, testing and commissioning of 20KVA UPS with IGBT UPS modules in capacity of capacity of 20 KVA with necessary BMS compatibility (hardware & software items for third party integration) with MODBUS protocol RS485, Telenet service -communication with LAN for sending mails/ messages in case any tripping or maintenance required with necessary software.
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 20 kVA (Continuous rating) online, modular UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links/wiring for each of above UPS units with 30 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.
EV Charging Equipments
Supply installation testing and commissioning of 60KW charger:- ITEM CODE-OEV 60K-2DCCS-LSC
Supply of CCS-2+CCS-2DC FAST EV CHARGER 60KW (Dual Gun) (200-1000v DC)
input Voltage (AC): 3Phase 415VAC(374-440VAC) Input frequency 50+1Hz
wire connections:5 (L1,L2,L3,N,PE) Number of outputs:-2Nos
Output Connector: 30KW CC-2+ 30KW CC-2(Max @30KW output)
Out put rarting:60KW
Display: 7" TFT LCD with touch user Authentication RFID Based
Charger and CMS Protocol OCPP1:6 (open charge point Protocol)
Interface: Ethernet/4G/Wi-Fi/Wire Length;7M
Ambient Temperature:- -20degree C to 55degree C Storage temperature 20degree C to 70degree C Altitude <2000Mtr
Humidity ; <95% Non-Condensing Ingress Protection IP54
Cooling Forced fan Air
Installation Charges
Commissioning Charges/unit
LUBICMS Software Integration- One time
LUBICMS Subscription 1 year
Supply installation testing and commissioning of 10KW charger:- ITEM CODE- LEVBAC001-10KD4G
Bharat Charger (BEVC-AC001) 10KW
input Voltage (AC): 3Phase 415VAC(374-440VAC) as per IS 12360AC
Input frequency 50+1Hz
wire connections:5 (L1,L2,L3,N,PE) Number of outputs:-3.3KW x3 Nos
Output Connector : IEC 60309 Industrial?domestic 3Pin Socket Out put Current :15A
Ambient Temperature:- -20degree C to 55degree C Storage temperature 20degree C to 70degree C Altitude <2000Mtr
Humidity ; <95% Non-Condensing Ingress Protection IP54
Installation Charges
Supply and fixing of supporting metal frame work for the 10KW charger panel
Commissioning Charges/unit
LUBICMS Software Integration- One time
LUBICMS Subscription 1 year
Supply,Erection,Testing and commissioing of Grid Connected Roof Top Solar system at Various Loactions in Main Building at Tidel Park, Hosur.
Supply,installation,Testing and Commissioing of Solar Panel 550 Watt II Pack of 2 II Half-cut 144 Cells II Dual Glass Mono Perc Bifacial Solar Panels II 30YearsPerformance Warranty.Modules must qualify to IEC 61215 / IS 14286 and IEC 61730 Part I and II for safety qualification testing or Equivalent IS(Under Dec.) & IEC 61701/IS 61701 90%output forfirst 10 years, 80% output for 25 years.
Module Mounting Structures: The PV modules will be mounted on fixed metallic structures of adequate strength and appropriate design, which can withstand load of modules and high wind velocities up to 160 km per hour. The support structure used in the power plants will be hot dip Galvanized Iron (G.I) with m thickness. The modules support structure shall be hot dip galvanized for holding the PV modules The leg of the structure shall be fixed and grouted in the PCC foundation column made with 1:2:4 cement concrete at depth of 4.5ft below ground with 1ftx1ft and 1 feet above ground. For each table, 8 nos of foundation columns should be provided to support the steel structure. The foundation shall support SPV modules at a given orientation, absorb and transfer the mechanical loads to the ground properly and shall withstand maximum wind speed of 160 km/hr. Total weight of the steel structure should not be less than 150 Kgs (each1 unit)
DC Cables: Supply and run 2 of 4sq.mm DC copper Cable PVC or XLPE insulated and PVC unsheathed single or multi core cable with minimum 6 sq.mm in suitable PVC pipe on wall from PV array to DCDB
AC Cables: Supply and run of 3x 50sq.mm aluminum PVC or XLPE insulated and PVC unsheathed single or multi core flexible cable with Voltage rating 1100V UV stabilized Copper Cable in suitable PVC rigid pipe on wall.
Power Conditioning Unit: The PCU shall also house MPPT (Maximum Power Point Tracker), and interface between Solar PV array & the Inverter, to maximize Solar PV array energy input into the system. PCU & protection PCU including MPPT & protection conform to IEC 61683/IS 61683, IEC 60068 - 2 (1,2,14,30) /Equivalent BIS Std. as per specifications PCU refers to combination of charge controller,inverter shall be supplied as integrated unit or separate units. Type of Switching Element has been IGBT/MOSFET, Type of Charger has been MPPT based PWM charger, Input from Solar Array has been 24 V (nom)-10% to + 15%. Protection has been input Over voltage, Low/High frequency, Short circuit. Load surge current, Over current, Under/over output voltage, Over temperature, Over voltage with auto recovery, indication has been Inverter 'ON' and over temperature.
Capacity: 25KVA - 1 No /Three Phase
Capacity: 50KVA - 1 No /Three Phase
ACDB: It shall be provided in between PCU and loads; It shall have MCB of suitable rating for connection and disconnection of PCU from load. It shall have MCBs to supply power to control room loads such as existing loads.It shall have AC voltmeter, Ammeter, Energy meter to record energy supplied to loads. It Shall be mounted close to the Grid-Tie Inverter with thermoplastic IP65 protection for cable termination points for identification. 1 In 1 Out │IP65 PC Enclosure │ 4P, 440V 63A MCB at solar side along with phase indication lamp │Type-2, 40kA SPD at grid side output
DCDB: DC Distribution panel is needed to receive the DC output from the array field, with analog measurement panel for voltage, current from different MJBs so as to check any failure in the array field. It shall have MCBs of suitable rating for connection and disconnection of array sections. Array Junction boxes with fuses and Surge Protection Devices with lightning and over voltage protection with thermo plastic IP65 protection junction boxes for cable termination points for identification 2 In 2 Out │ IP65/66 PC Enclosure with 1000V 12A fuse at each Positive I/P │ Terminal Block at Negative I/P and 2P MCB │ Type-2 40kA SPD at each Output │ MC4 Compatible Connectors at both input and output terminals.
Supply and installation Reverse power protection relay unit with control MCB in suitable enclosure with necessary accessaries & connection to be install near the PCU
Supply and insallation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth Connection
Supply and Fixing of 50MM Height TMC Insulator on wall with necessary bolt and Nut connection grouting on wall
Supply and fixing of UPVC Pipe accessories
Supply and fixing of Cable Tray 100 mm width on wall with Necessary clamps etc.
Supply and erection of Conventional Lightning arrester
MC4 Connectors, Cable Tray, Cable Conduit, Cable Tie, Cable Lugs, Cable Clips, Ferrules, Cable route marker, Inverter canopy, MDB Breaker , Fire Extinguishers,Caution sign Boards, Insulation mats
CEIG approval and TNEB charges
Comprehensive Maintenanace for 5 Years
Elevator Systems
DIESEL GENERATING SETS (WITH ACCOUSTIC ENCLOSURE)
Supply, design, Manufacturing, testing at manufacturers works & delivery to site including packing, transportation to site, installation, testing at site and commissioning of 3 Phase 415 Volts 50 cycle per second, 1500 RPM ,2250KVA Prime Rated Radiator Fan Cooled Diesel Generator Sets with PCC 3.3 and accoustic enclosure. The engine shall be complete with turbo charger, flywheel to suit flexible coupling with guard, air cleaner, blower fan, fuel pump, variable speed electronic governor, fuel filter, lube oil filter and pump, primary water circulating pumps, battery charger, 24 volt batteries of compatible capacity, MS battery stand and instrument panel comprising of switch with key, lube oil pressure gauge, water temperature gauge, battery charging voltmeter, safety control for low lube oil pressure, over speed and high cooling water temperature with tripping. The alternator shall be self excited, self regulated, brushless and continuously rated for kVA at 0.8 P.F., 3 phase 415 volts, 50 cycle per second, 4 wire system and shall be provided with static excitation unit. Alternator insulation shall be class 'H' suitable to withstand tropical conditions and shall generally comply with latest up to date amendment to IS Code. The overload capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. The DG Set shall be mounted on a fabricated rigid common base frame with anti-vibration mountings to provide 98% vibration isolation. The DG set shall include all accessories, fittings, instruments and standard tool kit complete as per specification and as required including control cabling. The cost shall include providing and fixing adaptor box for cable termination as required. The Governing system of the Diesel genets shall be compatible with the Synchronizing and auto load sharing The cost shall include providing adopter box for 415 alternator with rubber bellows.All DGs shall have the quick start facility. First Fill lube oil alsoshal be part of supplier scope only.
isolater enclosures: Supply Installation testing and commisioning of DG isolator Panel As per SLD mounting brackets, MS stand, clamps etc. and suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the box along with 4000A 4 Pole ACB. Including Suitables Adapater box
CONTROL CABLES
Supply , laying of 1.1KV Grade FRLS Copper armoured Control Cabling inbetween Day oil tanks, DG Sync Panel/DG power Panel, Auxillary power panel, Sensing cables from utility power panels along with its end terminations inclusive of brass double compression glands and copper lugs for complete auto & manual control and logical operations. All necessay control cabling shall be considered under this line Item required for fully auto operation of entire DG & Fuel system.
Supply & end termination of following CU FRLS armoured power/ control (shielded Signal) cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required
24C x 1 sq. mm. YWY cable
End termination for 24C x 1 sq. mm. YWY cable
12C x 2.5 sq. mm. YWY cable
End termination for 12C x 2.5 sq. mm. YWY cable
10C x 2.5 sq. mm. YWY cable
End termination for 10C x 2.5 sq. mm. YWY cable
6C x 2.5 sq. mm. YWY cable
End termination for 6C x 2.5 sq. mm. YWY cable
4C x 2.5 sq. mm. Cu. Flexible cable (Shielded )
End termination for 4C x 2.5 sq. mm. Cu. Flexible cable
4C x 2.5 sq. mm. YWY cable
End termination for 4C x 2.5 sq. mm. YWY cable
3C x 2.5 sq. mm. YWY cable
End termination for 3C x 2.5 sq. mm. YWY cable
2C x 4 sq. mm. YWY Cable
End termination for 2C x 4 sq. mm. YWY Cable
2C X 2.5 Sq. mm YWY cable
End termination for 2C X 2.5 Sq. mm YWY cable
4 Core x 1.5Sq.mm, PVC Insulated Copper conductor armoured cable for control cabling
End Terminations 4 Core x 1.5Sq.mm, PVC Insulated Copper
4 Core x 2.5Sq.mm, PVC Insulated Copper conductor armoured cable for sensor
End Terminations 4 Core x 2.5Sq.mm, PVC Insulated Coppe
FUEL SYSTEM :
Charges towards First fill of High Speed Diesel as per requirements of Day Oil of 3 Nos. Individual 415V , 2250 KVA LT DG Sets.
Supply Install , testing and commisioning of 990 Ltrs tank . The fuel tank shall be fabricated from 2 mm thick MS sheets and shall include the cost of removable cover with locking arrangement, the cost of painting, the cost of providing all the required appurtenances like inlet & outlet connection, float valves, drain connection, oil level indicator and low level/high level alarms and the cost of support arrangement And all other necessary accesories required for its complete installation complete as per specification as required. Level indicator shall be compatibel to BMS integration. The 990 Ltrs Tank shall be used as Day Oil Tank for individual DG Sets , Over flow tank and Buffer tank. M.S Steel Structure required for complete errection and installation shall be considered in this line item.
EXHAUST SYSTEM 'Supply, Erection, Testing & Commissioning of Self-supporting M.S Class B or 5mm thick DG Exhaust Pipes as specified & complete with all M.S supporting structures, sampling point, two coats of red oxide and anti corrosive painting, necessary anti-vibration supports, floor brackets, required insulation of 100mm thickness having density of 64 Kg/ M3 wrapped in chicken mesh and cladding as with 24 gauge alluminium sheet specified including erection. Expansion bellows shall be provided at necessary location. The diameter of the exhaust pipe has to be decided by DG vendors considering the horizontal and vertical length, bends involved to take required height for discharge as per CPCB norms.Back pressure calculation has to be submitted by DG vendor and get approved from Engineers incharge.
Exhaust pipe
300mm dia. Exhaust Pipe
600mm dia. Exhaust Pipe
Supply & Installation of Exhaust hot air GI duct with louvers with angle frame work & fixing accessories, to be fixed on external wall to throw hot air from chamber, it shall be suitable for supplying required air in CFM for Above DGs. complete system has be considered with rain water protection fins wherever required.
Silencer
Supply, Installation , Testing and commisioing of Silencer Insulation 50mm thick lightly resin bonded (LRB) rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.
Supply and installation of stainless stell vent cowl suitable for exhaust piping as provided above will all the necessary fixing arrangments and accessories to make it fully functional.
Supply and installation of SS flexible bellows
SS flexible bellows-300 mm dia
SS flexible bellows-600 mm dia
HSD WORKS
Design, Supply, fabrication, testing & commissioning of 20KL capacity MS tank for storing HSD as per drawing for below ground installation. Tank to be suitably fabricated with stiffeners as per approved drawing & IS10987.Tank shall be suitably fabricated with MS plate duly treated with necessary anticorrosive tar plastic compound externally with necessary accessories such as inlet, outlet, manhole, dipstick, fixed holding supports, bolts, nuts and necessary brackets on the tank etc., complete. Rate shall also include for necessary transportation, loading and unloading at site as directed. (Tank should be coated twice with anti-corrosive bituminous paint). Shell Plate 6mm & End Plate 10mm thick, The Dimesensions of 20KL Tank should be considered as per relveant IS standards ( IS 10987 )and as per stauatory requirements. Necessary drawing to be submitted for review and approval from Project Officer before procurement .
Suppply & Installation of SS 304 Single Braded wired Flexible hose(Unloading hose) suitable for diesel oil including fittings of one end flanged and other end with suitable coupler. Hose to have ACME End Connectors as per standards for un-loading of fuel. The flexible hose shall be 3 Mtrs in Length and 80 NB Diameter.
Supply & installation of Fuel Transfer Panel -1(FTP-1 IP 43 ) with all required controllers / PLC for communication with pumps and providing power supply to the transfer & overflow pump to be installed inside DG room.
Supply & installation of Fuel Transfer Panel -2 (FTP-2 IP 65 ) with all required controllers / PLC for communication with pumps/ centrifuge unit and providing power supply to the transfer & centrifuge unit to be installed near HSD storage area.
Supply & installation of Explosion Proof Local Push Button station with ON & OFF indication Lamps to be installed near the pumps in HSD Area as per the approved drawings.(IP 65)
Supply & installation of Local Push Button station with ON & OFF indication Lamps to be installed near the pumps as per the approved drawings. (IP - 43)
PIPING FOR FUEL SUPPLY SYSTEM
Suppply & Installation of Piping buried in ground / in trenches/ on Floor.
80mm dia.
65mm dia.
50mm dia
40mm dia.
25mm dia.
15mm dia.
Suppply & Installation of Ball Valve
80mm dia.
65mm dia.
50mm dia
40mm dia.
25mm dia.
15mm dia.
Suppply & Installation of Non Return Valve.
80mm dia
65mm dia
50mm dia
40mm dia
25mm dia
Suppply & Installation of Y' STRAINERS
80mm dia.
65mm dia
50mm dia
40mm dia.
25mm dia.
Suppply & Installation of Soleniod valve (Electrically Operated)
80mm dia.
50mm dia.
40mm dia.
25mm dia.
Suppply & Installation of Basket Strainer
80mm dia.
65mm dia.
50mm dia.
40mm dia.
25mm dia.
Pressure Guage / Pressure Indicator. Supply and fixing of Glycerin filled Pressure gauge 6" dial with 20NB isolation valve
Supply, Installation, Testing and commissioning of ultrasonic flow meter complete with all accessories and attachments
80mm dia.
65mm dia.
50mm dia.
40mm dia.
25mm dia.
Level Indicators & level controllers.
Supply and fixing of Digital level indicator for diesel UG tank,day tanks, Buffer tanks & Overflow tank.
Supply and fixing of Level control instrument , for diesel UG tank , day tanks , Buffer tank & Overflow tank with ModBus RS485 connectivity to integrate with BMS System to share the Pump Status and Oil Tank Variable ouputs in terms of Linearity/volume/Percentage of Tank Liquids
Supply and fixing of Drip tray for fuel pipes. The cost shall include necessary supports, necessary clamping on each fuel pipe running in the drip tray.200 x 75mm dia floor mounted MS drip tray, running along the length of fuel storage room and as header for pipes to individual DG's. 100 x 75mm dia floor mounted MS drip tray, running from main header to individual DG's in DG room.
Centrifuge Seperator Machine Supply , Installation , Testing and Commisioing of Centrifuge seperator (1W + 1S) as per specifications & Data Sheet complete with , 1. Exposion proof outdoor type Control Panel with Switchgear and Internal Cabling and Accessories. 2. Explosion proof Motor with necessary switch gear and internal cabling 3. Vavles , Pressure switch , pressure guage. 4. Temperature sensor , preheater ,thermometer. 5. Flow Switch , strainer , oil feed Pump. 6. Control Unit for heater , starters. 7. All Communicating accesories with PLC / Control of respective Fuel Transfer Panel. 7. All Interconnecting Accesories.
LIAISON WORKS Vendor should coordinate and Obtaining clearance, license and safety certificates from State pollution control board, CEIG ,CCOE (if Applicable) and other local bodies, etc if any applicable for installation and operation of the 3x 2250 kVA DG SET.
Charges for liaison work to getting approval from chief controller of Explosive (CCOE) For installation and operation of the storage and transfer system
MISCELLANEOUS ITEMS
Supply and installation of 2m x 1m Rubber Mat suitable for 33 KV & 1000V installation confirming to IS
Supply and installation of framed first aid chart (English & Local language) in panel room
Supply and installation of First Aid Box complete with all First Aid Medicines
Supply and installation of Shock Treatment Chart fixed in glass frame
Supply of Hand Gloves 33KV Grade
Supply & installation of 33 KV Danger boards
Supply & installation of 440V Danger boards
Supply and installation of framed, Laminated SLD in Electrical rooms
Supply & Installation of HT / LT cable route marker complete as per Latest Standards & regulations
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE Energy efficient 1200mm Sweep Ceiling Fan 5 Star Rated, inverter driven controlled by microprocessor with 300mm down rod with regulator / remote control (35 W)
Supply, Installation, Testing and Commissioning of 300mm dia. Box type single phase heavy duty exhaust fan with suitable louvers
Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of PMC / Employer. (For all building areas) DG stack - MS steel structure & painting with two coats of primer zinc oxide and two coats of approved enamel paint. All MS supports shall be measured in this line item (DG Stack, & DG day tank Supports)Quoted price shall be inclusive of Supporting arrangement at all levels & for the metal deck slab shall be with Wedge/ Gripple / Lindapter / fischer fixing arrangement for TR 60 / TR 80 metal decks. (Vendor has to submit Structural design calculation for DG stack supports separately and same shall be reviewed and confirmed by PMC / Employer before execution.
HVAC WORKS
Engineering, Supply, Inspection, testing, erection and commissioning of following items including water and air balancing.
CHILLERS
Design, Supply, delivery, hoisting, including the customs clearance, freight up to site, Insurance, port handling charges, other local duties, loading, transportation, receving at site, unloading, positioning the chiller as per approved shop drawing, installation including supplying & installing all necessary accessories as required for complete and satisfactory operation, testing & commissioning for the following items as shown on the equipment data and drawing for complete and satisfactory operation. Specification to be complied by the vendor to met the performance of chiller as per tender conditions. First chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. (Charges for arranging inspection of chillers for 5 persons, at Manufacturer’s point for witnessing testing the chiller ( 1no. chiller ) at minimum 4 test points. Clearly indicate the facilities available at manufacturer’s point for testing and also confirm wehther test bed is AHRI approved) All necessary hardwares / software's to integrate the chiller panel to BAS system shall be provided free of cost by chiller manufacturer / supplier. Control panel should be with open protocol like Modbus RTU/ Bacnet/ Lon work for integrating with BAS. Chiller is accepted only based on 100% loading and its performance shall be tested at site against approved data sheet. Any fall back on the performance to be corrected and rechecked and then chiller will be accepted.
a). Compressor extended warranty of 1 year for refrigerent leakage & mechanical seal.
b).Vendor must provide Junction box along with each set of unit including cable works from juction box to chiller.
d). Lubrication Device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, automatic pressure regulating valve, oil heater, thermal switch etc, as per detailed specifications and as required -- 1 Set
e). Matching Shell and Tube Water Cooled Condenser of M.S. Shell and integrally finned Copper Tubes, 2 pass heat exchanger.The Condenser shall have U- stamping / PED Certification
f). Matching Shell and Tube Flooded type Chiller for centrifugal unit consisting of MS Shell and Copper Tubes, 2 pass Heat Exchanger, duly insulated at factory complete as per specifications and as required. The Evaporator shall have U- stamping.
g). Refrigerant Line Accessories comprising of safety valves, angle valve, liquid line indications, liquid level control, liquid line isolation valve, etc. OR as per OEM design standard complete as per specifications -- 1 Lot
h). DP/ Water Flow Switches at inlet and outlet of the condenser & chiller, water drain & air purge valves wherever required, complete as per specifications -- 1 Lot
i). Suction Line and Chiller Insulation with minimum 19mm thick elastomeric nitrile rubber insulation complete as required from factory -- 1 Lot
j). Foundation Frame Work for mounting the above condenser, chiller, compressor and motor with base plate, panel complete with anti-vibration pads (set of spring type vibration isolators with isolation efficiency more than 90%. Numbers shall be as per OEM standards.), complete as per specifications -- 1 Lot
k). Initial/ First Charge of Refrigerant Gas and Compressor Oil - 1 Lot
l). Chiller shall be factory tested at 25%, 50%, 75% and 100% load at Constant Condenser Water inlet
m). Each chiller shall be provided with set of grooved coupling along with the chiller for cooler and condenser inlet / outlet connection.
n). Chiller OEM shall provide undertaking in the name of end user for providing support for maintenance & spare availability for next 15 yrs from the date of Handover
Chiller: Capacity - 410TR at Hosur Condition DBT 36Deg C & WBT 25.55 Deg C Chilled Water IN - 53.6°F . Chilled Water Out - 42.8°F Chilled Water Flow - 915 USGPM Fouling factor - 0.0001 FPS Units, Condenser: Condenser Water IN - 83.39 °F, Condenser Water OUT - 92.39°F Condenser Water Flow - 1423 USGPM Fouling factor - 0.00025 FPS Maximum Power Consumed at above conditions : Not more than 0.6 kW/ TR The chiller shall achieve a minimum full-load COP of 6.5 at AHRI standard rating conditions and a minimum IPLV of 10.0 under AHRI part-load conditions.
CHILLER ATC - Supply, Installation, testing & Commissioning of Automatic Tube Cleaning system ( ATCS ) for 6 Nos. Chillers (1:1) shall include Touch Screen Graphical PLC, one injection/collection pump, actuator based valves and complete with all accessories and Low side activities of piping connections from Ball traps to Ball collectors and Chillers. The actuator based valves shall give signals to PLC of their functioning and all process of injection and collection should be shown on the PLC while in operation. The ATCS System can be individual to each chiller or may handle multiple chiller at a time. As per specification/drawings and as directed by PMC/Employer.
COOLING TOWER
CHILLER PLANT MANAGER
Supply, Installation, testing & Commissioning of Chiller Plant Manager including LCD Display, DDC Controller with all instruments, accessories and interconnecting control & power cabling, tray and etc.,supporting & controlling the proposed chilled water system as per specification/drawings and as directed by PMC/Employer Following are the list of equipment - Chillers - 410 TR x6 nos - Primary Chilled water Pumps - 6 nos - Secondary Chilled Water Pump - 6nos - Cooling Tower - 6 nos ( 2/4 fans each) - Condensor Pump - 6 nos - Motorized Butterfly Valve - 24 Nos - Auto Tube Cleaning - Pressurization Unit - Water level switches in cooling towers (6 Nos )
CPM to control chiller plant as describe above
CENTRIFUGAL VERTICAL INLINE PUMPS
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-5). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.
e. The duty point of the pump shall be defined in the pump curve
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 40kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.
g. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 22 W/gpm, Motor efficieny not less than 90% (IE-5). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.
e. The duty point of the pump shall be defined in the pump curve
f. Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding.
g VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design. VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor.VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be motor mounted and IP 54 rated.
h. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
b. Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller, mechanical seal & Suction guide.
c. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficiency should not be less than 85% & pumping power must not exceed 19 W/gpm, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection.
d. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.
e. The duty point of the pump shall be defined in the pump curve
f. Head Indicated below is tentative , Contractor shall submit Pump static head calculations based on approved shop drawings before ordering the pumps. Any rise in head required shall be offer by contractor without any additional cost. Note- "The Variation in Static Head Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
Ceiling Suspended Air Handling Unit with EC motor
Supply, installation testing & commissioning EUROVENT CERTIFIED CSU Airhandling units having following specifications. a. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . b. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage with velocity less than equal to 500 FPM. c. Coil Section: Chilled water coil Min. 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, Coil shall be provided with copper header. d. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. e. Fan Section: Shall be with multiple EC fans coupled with IE5 motors along with potentiometer and shall accept analogue signal from BMS for speed variation. EC fan shall also provide BMS output through Modbus over RS 485 with following readings on a digital display mounted on the AHU. (EC fan Status, Air flow, speed feedback, CO2 sensor controller based on CO2 level, soft integration as minimum). Unit shall be able to vary the fan speed based on the BMS input. Unit shall be provided wtih safety features like limit switch /marine lamp interlocked with the door. f. Noise level should be lessthan 55dba@1meter distance, Fan Acoustic inner insulation to be considered further noise level reduction. g. Supply & Installation of compatible room thermostat with shall be with inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status through BMS. h. Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top i. Supply & Installation of Halogen Free control wiring between the unit and thermostat including 25mm dia pvc conduit j. Starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered.
3TR/1200 CFM ESP 15 MM
5TR/2000 CFM ESP 15 MM
8TR/3200 CFM ESP 15 MM
11TR/4400 CFM ESP 25 MM
12TR/4800 CFM ESP 25 MM
15TR/6000 CFM ESP 30 MM
TREATED FRESH AIR UNITS.
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.
STRIP HEATERS ( Mounted within the Ahu cabinet) WITH SCR CONTROL: Electrical Heaters complete with locate inside the AHU cabinet to which it has to be connected suitable for operation upto 950°F & RH up to 90%. The heaters shall be made out of SS-321 sheathed tubular elements with / without fins, heating elements mounted on detachable terminal plate galvanized retainers, mounting flange for attaching it to the Ahu unit work, thermal cut-out fitout for over heating, thermostat control, contactor & fan interlock device, flame proof cover, disconnect switch, door interlock switch, SCR control, fan control relay, protective screen, insulated control panel, supports etc. The Heaters shall be installed inside the AHU. The unit shall be suitable for operation through BMS System and shall be provided with necessary PFC contacts / relays.
BMS compatible starter panel with VFD and bypass starter with on/off push button station / PFC contacts / Overload relays/ fire trip integration provsion with all accessories to be considered. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered
28TR/5000CFM with 30mm ESP
33TR/6000CFM with 30mm ESP
39TR/7000CFM with 30mm ESP
50TR/9000CFM with 30mm ESP
Chilled Water Cassette
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of 1 Ball valve with and 1 without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Digital wireless remote shall be part of scope.Unit should be with Inbuilt Drain Pump. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status.
1.0 TR ( Four way cassette)
1.5 TR ( Four way cassette)
2.0 TR ( Four way cassette)
3.0 TR ( Four way cassette)
DRAIN PUMPS
Supply, Installation, Testing & Commissioning of Condensate Drain Pumps (1W + 1S) with Tank along with Level sensor. The pump should be interlocked with the sensor to avoid dry run. The pump should be with an Inbuilt non-return valves on discharge & solenoid valves as required. The tank capacity should be minimum 2 Litres in Capacity. The pump should be able to deliver 6m Vertical head @ 150 litres/ hr flow rate. The Power supply shall be single phase 230 V AC. Single phase power shall be provided near-by the pump. The necessary UPVC / CPVC Piping & Cabling Connection shall be done by contractor and the cost for the same to be considered (5m Cabling to be Included). Application - Critical Rooms
MINI DRAIN PUMPS
Supply, Installation, Testing & Commissioning of Condensate Drain Pumps with Tank along with Level sensor. The pump should be interlocked with the sensor to avoid dry run. The pump should be with an Inbuilt non-return valves on discharge & solenoid valves as required. The tank capacity should be minimum 1 Litres in Capacity. The pump should be able to deliver 6m Vertical head.The Power supply shall be single phase 230 V AC. Single phase power shall be provided near-by the pump. The necessary UPVC / CPVC Piping & Cabling Connection shall be done by contractor and the cost for the same to be considered (5m Cabling to be Included). Application - Cassette Units . FCUs.
VENTILATION WORKS
Tube Axial Flow Fan for Smoke & Pressurization
a). Supply, Installation, testing & Commissioning of Smoke Evacuation Tube Axial fan for Room Smoke exhaust complete with MS channel base, housing, fire retardant flexible connection with nut bolts at outlet, mounting, spring vibration isolators, & bird screen,wherever required for complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/EMployer
c). The complete fan assembly shall be CE Certified in accordance with EN-12101-2:2015 or UL Listed conforming to UL-705 Power Ventilator for smoke exhaust OR TUV SUD PSB Pte Ltd(Vendor shall submit the certifications for below listed fans) Fan casing shall be de-rusted, cleaned, primed and finish coated with enamel paint or shall be hot dip galvanized with min. 220 GSM coating. Fan casing, motor mount support brackets for ceiling suspension shall be welded or bolted to the casing for connection to hanger bolts. Hub and Blades of Axial fans Impeller/Rotor shall be constructed for cast aluminium or aluminium alloy. Extended grease leads for external lubrication shall be provided for motors above 180 frame size. The fan pitch control maybe manually readjust able at site or at manufacturer’s facility. The motor and impeller speed shall be as per specification and capacities shall be as follows. Fan & motor shall be suitable for outdoor application. Necessary spring isolators for mounting of fan shall be considered in the cost.
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
15000 CFM, 35mm ESP - Lift Lobby Pressurization
16000 CFM, 35mm ESP - Lift Lobby Pressurization
17000 CFM, 35mm ESP - Lift Well & Stairwell Pressurization
10000 CFM, 35mm ESP - Lift Well Pressurization
Ducted Axial Flow Fan
a). Supply, Installation, testing & Commissioning of Tube Axial fan for Room exhaust sutiable for Ducting along with Sound Attenuators to achieve noise levels as mentioned complete with MS channel base, housing, fire retardant flexible connection with nut bolts at outlet, mounting, vibration isolators, & bird screen,wherever required for complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/EMployer
c). The complete fan assembly shall be CE Certified in accordance with EN-12101-2:2015 or UL Listed conforming to UL-705 Power Ventilator for smoke exhaust OR TUV SUD PSB Pte Ltd(Vendor shall submit the certifications for below listed fans) Fan casing shall be de-rusted, cleaned, primed and finish coated with enamel paint or shall be hot dip galvanized with min. 220 GSM coating. Fan casing, motor mount support brackets for ceiling suspension shall be welded or bolted to the casing for connection to hanger bolts. Hub and Blades of Axial fans Impeller/Rotor shall be constructed for cast aluminium or aluminium alloy. Extended grease leads for external lubrication shall be provided for motors above 180 frame size. The fan pitch control maybe manually readjust able at site or at manufacturer’s facility. The motor and impeller speed shall be as per specification and capacities shall be as follows. Fan & motor shall be suitable for outdoor application. Necessary spring isolators for mounting of fan shall be considered in the cost.
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
41500 CFM, 40mm ESP, Noise level of the fan should be less than 65dba @3M distance- DG Room Exhaust (With attenuator)
21,000 CFM, 35mm ESP, Noise level of the fan should be less than 65dba @3M distance- STP Room Exhaust (With attenuator)
19,000 CFM, 30mm ESP, Noise level of the fan should be less than 65dba @3M distance- Plant Room Exhaust (With attenuator)
15,000 CFM, 30mm ESP, Noise level of the fan should be less than 65dba @3M distance- Transformer Room Exhaust (With attenuator)
10,000 CFM, 25mm ESP, Noise level of the fan should be less than 65dba @3M distance- LT Panel Room & chiller Pump Room Exhaust (With attenuator)
8000 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- Pump Room Exhaust (With attenuator)
18,000 CFM, 25mm ESP, Noise level of the fan should be less than 65dba @3M distance- STP Plant Room Fresh air (With attenuator)
16,000 CFM, 25mm ESP, Noise level of the fan should be less than 65dba @3M distance- Chiller Plant Room Fresh air (With attenuator)
12500 CFM, 25mm ESP, Noise level of the fan should be less than 65dba @3M distance- Transformer Room Fresh air (With attenuator)
8500 CFM, 20mm ESP, Noise level of the fan should be less than 65dba @3M distance- LT panel & Chiller Pump Room Fresh air (With attenuator)
Outdoor Mount Cabinet Fans
Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
11000 CFM, 40mm ESP - Electrical Room Exhaust
12000 CFM, 40mm ESP - Toilet Exhaust
14000cfm -40MM ESP - Fresh air for Electrical Room
7000cfm -50MM ESP - Kitchen Fresh air Duct with Pre & fine filter (MERV 08 & 13) (Ceiling Suspended Unit).
DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:
b). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
c. The cost of the Inline Fan also includes DOL Starter with On/off push button staton, A/M Status and PF/relays etc for BMs integration and along with inbuilt fan regulator.
d. All Inline fan shall be provided with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.
1600 CFM, 15mm ESP - Toilet Exhaust
1500 CFM, 15mm ESP - Toilet Exhaust
500 CFM, 25mm ESP
250 CFM, 25mm ESP
KITCHEN FAN SISW FAN
a). Supply, Installation, testing & Commissioning of Fan - SISW backward curved centrifugal fan with necessory supports arrangement, sq cage induction motor, GSS frame support work, belt drive with required size pullys and belts, spring type vibratioin isolator, base frame along complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by PMC/Employer
c). Fan motor shall be class IE4 and suitable to 415+/-10% V, 50 hz, 3 phase AC supply. Fan shall be suitable for Kitchen exhaust. Fan total efficiency shall not be less than 70%. However; If OEM is not able to meet 70% efficiency for any specific case, 65-70% fan efficiency can be accepted subject to detail technical justifications from Vendor/OEM." Max. noise level shall be 75 dBA at 3 meter in hemispherical reverberant room condition.Fan power should not exceed 0.0006 BHP / CFM.
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Note- "The Variation in Static Pressure Rise more than 20% will only be consider for Extra item, If there is change in layout w.r.t Tender drawing."
8000 CFM @ 125 mm ESP
Kitchen Dry Scrubber
b). Operating voltage - 220 VAC+/-10%, 50 Hz (Single phase) Cell - Ionizing voltage - 12 KVdc Collector voltage - 6 KVdc One cell comprising of 9 ionizing wires and 25 collection plates Controls - Auto cut-off when door is opened. Indicator lights for fault, normal or wash function. Pre-filter - Aluminium mesh, washable Dry contact for BMS. Unit must be of Autowash type.
Chemical Passivation of System as per below requirement for below Mentioned Chilled Water Piping Quantity. All Pipes need to be flushed before initiaion of Chemical Flushing. Water quality tests before and intermediate between adding of chemicals to be done and report to be generated. Necessary auto dosing system PLC based with TDS Analyser, pH Sensor etc. to be considered. for automatic working of the system. Contractor to submit the chemical weight calculations, standard operating procedures and operations manual before initiations of work. 1 Yeat weight of chemicals to be considered in the cost. i, Pre-Cleaning & Passivation with chemicals, ii, Surfactant cleaning, iii, Bioflushing, iv, Low pH cleaning, v, Passivation Chemical
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES (PLANT ROOM & OUTDOOR PIPES)
Supply, erection, testing and commissioning of pre-insulated pipes for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be PUF as per the specification. The pre-insulated pipe shall be covered with 24 Gauge aluminium spiral casing. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia Pipe dia – mm Thickness - upto 200 mm dia - 5 mm thickness 250 mm to 350 mm dia - 6 mm thickness. above 350 mm dia - 8 mm thickness insulation details Up to 32 mm : 30mm thick 49 mm to 100 mm : 40mm thick 125mm up to 300 mm : 50 mm thick 350 & above : 75 mm thick All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item.
450 mm dia.
400 mm dia
350 mm dia.
300 mm dia
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
80 mm dia
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES (RISERS & CONNECTIONS) Supply, erection, testing and commissioning for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be with Closed Cell Nitrile Rubber with Al Foil / Glass Cloth as per the specification. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia. All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item.
250 mm dia (45 mm thick insulation)
200 mm dia (45 mm thick insulation)
150 mm dia (45 mm thick insulation)
125 mm dia (45 mm thick insulation)
100 mm dia (32 mm thick insulation)
80 mm dia (32 mm thick insulation)
65 mm dia (25 mm thick insulation)
50 mm dia (25 mm thick insulation)
40 mm dia (19 mm thick insulation)
32 mm dia (19 mm thick insulation)
25 mm dia (19 mm thick insulation)
Supply and erection of Insulated PN-16 Manual Butterfly valves with C I body SS Disc, Nitrile Rubber Seal & O- Ring (as per specifications) complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc. The valve shall be gear operated for 200NB and above. Insulation shall be as per piping insulation specification.
450 mm dia
400 mm dia
350 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
Supply and erection of Insulated PN-16 Dual plate Check valves of C I body SS plates vulcanized NBR seal flanged end complete with pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.
250 mm dia
200 mm dia
125 mm dia
Supply, Installing, testing and commissioning of PN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod & Nitrile rubber insulated covered with 24G aluminium sheet box, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications. As per specification/drawings and as directed by PMC/Employer.
250 mm dia
200 mm dia
125 mm dia
Design, Supply, installation, testing and commissioning of Insulated PN-16 Balancing Valve with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation. It shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.
250 mm dia
200 mm dia
150 mm dia
125 mm dia
100 mm dia
Supply and erection of Insulated PN-16 ‘Y’ type strainer of Ductile CI Body flanged ends with stainless steel strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.
250 mm dia
200 mm dia
125 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
Design, Supply, installation, testing and commissioning of Insulated PN-16 Motorized Valves (ON / OFF Type) with thermal insulation provided with spring return function in chilled water lines at chillers and condenser water line at cooling towers. Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. The Actuator shall be supplied along with its Actuator panel.
250 mm dia
200 mm dia
125 mm dia
100 mm dia
Design, Supply, Installation, testing and commissioning of Insulated Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves with Thermal Insulation for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat (modulation type) suitable for the given actuator, required length of 2Cx1.5Sqmm shielded communication cable, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation, etc The Actuator shall be supplied along with its Actuator panel.
65 mm dia
50 mm dia
40 mm dia
32 mm dia
BTU METER
Supply, installation, testing and commissioning of BTU Meter - to measure the HVAC Consumption Purpose. The Unit shall include an Heat Meter Integrator, Ultrasonic type Flow meter, matched pair of Temperature Sensors (along with the protection pockets). The Integrator shall have Battery backup for 12 years, Data Logging for 15 years, 230V AC power supply provision, 8 Digit LCD Display The Unit should be capable of displaying the CHW Flow Rate, BTU / Hr, KWH, CHW Temperature. The Unit shall be with IP55 grade of protection (Maximum Pressure drop across BTU meter 0.2 WC) The BTU Meter shall be MID approved In-Line Flange Connection type. The Integrators shall be capable of communicating on a communication bus to the BMS on one of Standard Open Protocols such as MODBUS / Bacnet over IP etc. BTU Meters shall be tested for performance and accuracy before delivery.
a) Inline Flow Meter, b) Match Pair Sensors c) Heat Integrator d) Minimum 4 Data / Meter to Master Contoroller - T1 / T2 / Flow / KWH - with 2 mtr 2C shielded communication cable
Btu Transmitters as per the specification for tenant billing. Btu Meters shall consist of following items of following sizes:-
400 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Power supply cable for BTU Meters - 3 core 1.5 sqmm shielded FRLS cable including glands along with 25 mm pvc conduit
Supply and erection of PN-16 pressure rating extended stem ball valve, bronze forged body, Stainless Steel ball and control level etc. in position complete as per technical specifications with all the necessary mounting accessories, end flanges / matching flanges, additional supports, fixing accessories, thermal insulation, etc.as required for complete installation as per specification.
40 mm dia
32 mm dia
25 mm dia
Supply, installation testing & commissioning of Thermometers - Dial Type - 4" Dia (ALL SS TYPE) Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services. It should be installed in the thermowells as explained in the tender specifications. Extension nipple shall be provided for a minimum depth of 150 mm.
Supply, installation testing & commissioning of Automatic Air Vents with Ball valve shall be installed at all high sections of piping as well as in the AHU room piping. The discharge from this air vents shall be piped via copper tubes of appropriate size to the nearest waste drain pipe. 15 mm dia. With 15mm ball valve
EXPANSION TANK & PRESSURISING UNIT
b). Supply, Installing, Testing and commissioning of Pressurizing unit consisting of Inline vertical multistage, centrifugal clear water pumps ( 1W+1S) with S.S. 304 casing, S.S. 304 impeller and S.S. 316 shaft, CI Base,TEFC motor (with mechanical seal) with control panel with duty cycling and dry run protection and set of accessories such as pressure transmitter, suction and discharge pipe manifolds, pressure gauges, valves etc. conforming to the specifications. The make up tank location should be at least 1 meter above the pump level. As per specification/drawings and as directed by PMC/Employer.
2000 litres
AIR SEPARATOR
a).Supply, Installing, Testing and commissioning of centrifugal/ coalescence / microbubble type air separator with pall rings for following pipe size. The unit shall have an internal stainless steel collector tube with 5/32” (4mm) diameter perforations and 63% open area designed to direct accumulated air to the compression tank on an air control system or an air vent on an air elimination via an NPT vent connection at top of the unit. As per specification/drawings and as directed by PMC/Employer. b). Air separator shall duly insulated with closed cell elastometric nitrile rubber as per Header Piping Specifications
450 dia - PN 16
CONDENSER WATER PIPE AND VALVES
Condenser Water Piping. Suppling, fixing testing & commissioning of condenser water pipes of following sizes of MS C' Class along with nececessary clamps, vibration isolators and fittings sich as bends, tees etc. but excluding valves, strainers, gauges etc, adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc, as per slecification and as required complete in all respect. Note: The pipes size 150mm & below shall be M.S C class as per IS : 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. sheet for pipe upto 350mm dia. And from minimum 7mm thick MS sheet for pipes of 400mm dia and above.
500 mm dia
450 mm dia
350 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
50 mm dia
Supply fixing testing and commissioning of BUTTERFLY VALVE Manual with C I body SS disc nitrile sheet % O - ring & PN 16 pressure rating complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc
500 mm dia
250 mm dia
150 mm dia
100 mm dia
80 mm dia
50 mm dia
Supply fixing testing and commissioning of Non Return Valve for condenser water circulation as per specification. Non-Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating complete with end flanges/matching flanges, additional supports, fixing accessories, etc.as specified.
250 mm dia
Supply, Installing, testing and commissioning of PN 16 rating Flexible Pipe Connections (Expansion bellows) with connecting rod & Nitrile rubber insulated covered with 24G aluminium sheet box, in position complete with flanges,bolts,nuts, including gaskets etc.conforming to specifications. As per specification/drawings and as directed by PMC/Employer.
250 mm dia
Design, Supply, installation, testing and commissioning of PN-16 Balancing Valve with C I body flanged construction with EPDM coated disc shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.
250 mm dia
200 mm dia
Supplying, fixing, testing and commissioning of following sizes Motorized butterfly valve with CI Body, SS Disc, O-ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20mA electric signal and providing simillar transduced feedback output to control system as required. The Actuator shall be supplied along with its Actuator panel.
250 mm dia
200 mm dia
Supply, installation testing & commissioning of Thermowells. Extension shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.
Supply, installation testing & commissioning of Binder type Test Points. Extension nipple shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.
Supply and installation of PN-16 Pot strainer of size suitable for 500NB pipeline to remove the dirt particles in the condenser water loop with necessary flanges, washers, painting, etc. complete as required. MS (IS 2062-1992 Gr A) body and bonnet with Stainless Steel 3 mm perforated x 24 G thick filter screen, black rubber gasket, heavy duty mild steel hand wheel & stainless steel-410 drain plug etc. Testing confirming to BS - 6755 Part-1.
Providing, fixing and testing GI 'B' Class (Medium class) drain piping for condensate complete with 9 mm thick nitrile rubber insulation with class O, covered with interwoven glass fabric for UV and mechanical protection, all required fittings and providing clean out plug at suitable location for roding the pipe when required.As per technical specifications with all the necessary mounting accessories as required for complete installation. As per specification/drawings and as directed by PMC/Employer.
50mm dia
40mm dia
Supply Insulated CPVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire drain pipe needs to be insulated with 6mm thick closed cell Nitrile rubber.
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
LOWDISE DUCTING WORKS
Supply, installation balacing and commissoning of factroy fabricated GSS sheet metel rectangular/ round duct complete with neoprene rubber gaskets, elbows, spliter dampers, vanes, hangers suppots, etc. As per approved drawings and specifications of following sheet thickness complete as required. All ducts shall be fabricated either from Galvanised Sheet Steel (GSS) conforming to IS: 277 or aluminium sheets conforming to IS:737. The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. The Duct with TDF Flanges shall be accepted as per SMACNA. Duct pressure test to be considered (0-500 Psi) with nessarry supporting materials part of this item (Vendor need to be submit detailed report before applying insulation.
0 to 750 mm - 0.63 mm ( With Ductmate Flanges)
751 to 1200 mm 0.8 mm ( With Ductmate Flanges)
1201 to 1500 mm - 1.0 mm ( With Ductmate Flanges)
1501 & Above - 1.2 mm (With Ductmate Flanges)
Supply, installation, balancing and commissioning of Flat Oval / Spiral Oval / Round Ducts (Shall be approved as per Architect) base complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. All ducts shall be fabricated either from Galvanised Sheet Steel (GSS) conforming to IS: 277 or aluminium sheets conforming to IS:737. The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. Note:- The Duct with shall be accepted with following: 1.For reinforcement of Duct shall be followed as per IS-655:2006 table number 23. 2.Ducts shall be tested as per specifications post installation. 3. Necesary steel wire rod supports / rigid supports for Installation to be considered 4. All ducts to be Insulated with 9mm Closed Cell Nitrile Rubber Insulation internally as per Tender Specifications
Thickness 0.63 mm sheet- 0 to 650 mm
Thickness 0.80 mm sheet - 651 to 1250 mm
Thickness 1.00 mm sheet - 1251 to 2200 mm
Thickness 1.25 mm sheet - 2201 & Above
LOWDISE AIRTERMINAL WORKS
Supplying, fixing testing commissioning of supply air square / plaque diffusers of powder coated aluminium as per approved shade with aluminium volume control dampers, necessary insulated plenum box with anti smudge ring & removable core. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer. The Billing Area shall be based on Neck Size.
Supplying, fixing testing commissioning of Return air square / plaque diffusers of powder coated aluminium as per approved shade without volume control dampers with anti smudge ring & removable core. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer. The Billing Area shall be based on Neck Size.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills 1.6mm thickness as per standards as per approved shade with aluminium anodized opposed blade volume control dampers as per specifications. Note- Grill shall be provided with 0 deg / 15 deg or with double delfection type as per interior requirment. Colour: Approval shall be obtained from Interior consultant.
Supplying & fixing of powder coated extruded aluminium Return Air Grills 1.6mm thickness as per standards as per approved shade without volume control dampers. Note- Grill shall be provided with 0 deg / 15 deg or with double delfection type as per interior requirment. Colour: Approval shall be obtained from Interior consultant.
Supplying & fixing of powder coated extruded aluminium removable core type Supply Air Slot Diffusers (1 Slot / Multiple Slot as per Drawing) 1.6mm thickness as per standards as per approved shade with aluminium anodized opposed blade / hit & miss volume control dampers & inusulated plenum boxes as per specifications. Colour: Approval shall be obtained from Interior consultant.
Supplying & fixing of powder coated extruded aluminium removable core type Return Air Slot Diffusers (1 Slot / Multiple Slot as per Drawing) 1.6mm thickness as per standards as per approved shade. Colour: Approval shall be obtained from Interior consultant.
Supply, installation of Collar Dampers of opposed blade type made out of Aluminium alloy extrusion with anodised matt black finish.
Supply, Installing, testing and comissioning of Powder coated extruded aluminium construction fresh air/ Exhaust air louvers with min. 60 % free area, bird screen as per specifications. Louvers need to be suitable in order to avoid rain water entry @ 45 degree deflection.As per technical specifications with all the necessary mounting accessories as required for complete installation. Colour: Approval shall be obtained from Interior consultant. As per specification/drawings and as directed by Architect & PMC/Employer
Supply and installation of Powder coated extruded aluminium Disc Valve of the following diameter for exhaust air. The rate shall be inclusive of volume control damper and necessary fixing and supporting arrangement for the valve. Size:150mm Dia neck
Supply, installation of JET NOZZLES of powder coated aluminium with volume control dampers & removable core for supply air distribution. Colour: Approval shall be obtained from Interior consultant.
350 mm dia
300 mm dia
Supply, installation of JET DIFFUSER of powder coated aluminium with volume control dampers & removable core for supply air distribution. Colour: Approval shall be obtained from Interior consultant.
350 mm dia
300 mm dia
Supply, installation of Insulated Flexible Ducting Factory Fabricated Insulated with 32 kg/mr3 dense Glasswool Flexible ducts made out aluminium for connecting from main duct to diffuser box duly supported at regular interval as per site requirement etc. The length of the flexible duct shall be around 1.0 to 1.5 mtr.
150 mm dia (Un-Insulated Semi flexible duct)
250 mm dia
300 mm dia
Supply installations of Butterfly Dampers made out of 20G GI sheets similar duct specifications.
150mm dia
200 mm dia
250mm dia
300mm dia
Oppossed blade Low leakage Aluminium volume control damper with locking arrangement. VCD Construction16G GI in multi blade with handle and wing nut , clearly marked with open/close, for supply and return air duct branches. Low Leakage Volume Control Dampers of Class 1. VCD shall be complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. (Extended shaft of minimum 150mm length with GI base plate shall be provided wherever required during drawing Approval). Volume Control damper may be without AMCA certification. However, OEM's Self Certification is required for leakage Class-I.
Supply, installation, testing and balancing of Pressure Relief Dampers made out of 1.6 mm thick galvanized sheet steel frame and blades of 1.6 mm galvanised sheet steel with linkages capable of maintaining constant pressure at various airflows & close upon decrease in differential pressure. The damper shall be designed to provide pressure relief at 50 Pascals & 15 m/s velocity.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper and necessary control wire (minimum 1.5 sqmm) for integration within AHU room / Equipment Volume Control damper may be without AMCA certification. However, OEM's Self Certification is required for leakage Class-I.
Supply and installations Motorized Modulating type low leakage air dampers made out of 1.6mm thick galvanised steel frame & blade. damper shall be complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Extended shaft of minimum 150mm length with GI base plate shall be provided wherever required during drawing Approval). Volume Control damper may be without AMCA certification. However, OEM's Self Certification is required for leakage Class-I.
Supply and installations testing & commissioning of Modulating type damper actuator with control panel, fresh air modulation with actuator complete with all accessories like Actuator,control panel etc and any necessary requirement which can perform the controlling the Damper. It shall be integrated with Co2 sensor and based on CO2 levels, damper shall be modulate. The damper shall be set at minimum 100 % fresh air supply and it shall modulate from 100 to 130 % fresh air supply as per the signals recieved from the CO2 sensor. Panel should be compatible for third party BMS integration via Rs485 / Modbus controller, necessary fire integrator should be consider in part HVAC vendor scope.
Supply and installations testing & commissioning of CO2 sensor with necessary cable between CO2 sensor to modulating actuator panel.
Fire & Smoke damper with Sleeves as per specifications.
Fire & Smoke damper without Sleeves as per specifications.
Actuator - 5 Nm
Actuator - 10 Nm
Fusible Link
Supply, installation of Back Draft Dampers made of 1.6 mm thick galvanised steel frame and blades of 1.6 mm galvanised sheet steel
LOWSIDE DUCT INSULATION MATERIALS
Duct Acoustic Insulation - Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Open Cell Elastromeric Nitrile Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. Density shall be 140 -180 kg/m3 Thickness shall be 15mm
Duct Acoustic Insulation - Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Open Cell Elastromeric Nitrile Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. Density shall be 140 -180 kg/m3 Thickness shall be 9mm
Duct Thermal Insulation - Supply and fixing of Duct / Floor Insulation of class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . The insulation manufactured as per BS 476 Part 6 & 7 should have thermal conductivity of 0.033W/m.k @ 0 deg C as per DIN EN 12667. and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide & 3 mm thick Aluminium foil self adhesive tape (Black Cotton Tape not acceptable). Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. for floor, ceiling, wall upt to false floor. As per specification/drawings and as directed by PMC/Employer. Note - Insulation shall be Anti-Microbial type, UL approved & must have factory laminated aluminium foil.
9 mm - Supply / Return / Floor Insulation
13 mm - Return Air Ducting
19 mm - Supply / Fresh Air Ducts through Conditioned Space
25 mm - Supply / Fresh Air Ducts through Un-conditioned Space
Duct Thermal Insulation (For Outdoor) - Supply and fixing of Floor Insulation of class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . The insulation manufactured as per BS 476 Part 6 & 7 should have thermal conductivity of 0.033W/m.k @ 0 deg C as per DIN EN 12667. and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide & 3 mm thick Aluminium foil self adhesive tape (Black Cotton Tape not acceptable). Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre. for floor, ceiling, wall upt to false floor. The Insulation at Terrace shall be painted with UV Resistant Paint Note - Insulation shall be Anti-Microbial type, UL approved & must have factory laminated aluminium foil.
25 mm - Supply / Fresh Air Ducts through Un-conditioned Space
SITC of underdeck insulation for all AC areas exposed to directly Sun shall be provided with 50 mm thick TF quality Expanded Polystyrene slab or material of equivalent u value. The material shall be conform to IS:4671 & shall be of type ‘N’ unless specified otherwise. The apparent density shall be of 24 Kg/m³. The thickness of the material to be of 50mm. The vendor to include the cost of all material related to installation of the same for the top slab level with cleaning and making surface dust free, applying adhesive and providing 600x600 mm wire mesh grid with 26 G GI wire along with EPS slabs pasting on the surface. Vendor to ensure the installation as per PMC/Employers satisfaction.
Room Acoustic Insulation -Supply and fixing of acoustic lining with 50 mm thick resin bonded glass wool having density of 48 kg/m³, with 50 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Canvass connection : Supply, installation of Heavy duty double layered Canvass connection consisting of a flame retardnat fabric secured between galvanized sheet metal on either side by a double lock seam inserted between the equipment / Duct to provide wear resistant air tight flexible connection to eliminat vibrations, noise and rattles with fire rating EN532 and 533. The connection shall be 150mm in width. Only extra connections apart from those already mentioned in Fan Description shall be certified.
FIRE SEALENT
Supply and installation of Acrylic fire stop sealant CP606 or Approved Equivalent )with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. Sealant to provide sufficient MAF, water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation . The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall be FM approved. All installations to be in full accordance with the manufacturer. The sealant should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. The rate shall include the mineral wool backing material and other miscellaneous items etc.., Assumed 15% Penetrants Ocupancy. Firestop installation should be done by HAFSC ( Accredated Firestop Speciality Contractor by providing complete installation report using CFS DM). Or using FIT (Firestop Installer Training) Program. As per IFC Guideliness EJ is recomended for non standard openings.-( supply & return air ducts.)
Kitchen exhaust ducting and accessories
MS Ducting - grade material 16 G with complete joints, & MS supports at every 1.5 mts capable of taking 600 kgs point load - Floor,Shaft & Terrace Area. Necessary scafollding required for erecting above within the shafts from 16th floor to terrace should be considered in the scope of works. Fire rated gasket material to be used for duct joining. Mockup to be provided for the duct support arrangement along with duct joints before going ahead.
Grease Collection Box near the unit. Construction of Grease Collection Box should be similar to same as Ducting specified above
20 Inches x 20 Inches Trap Door fabricated of same material / specs as Ducting specified above. Acess panel shall have a gasket which can sustain 1500 deg F (815 deg C) temperature. Same need to be located in the kitchen area, shafts , units etc
Volume control Damper made out of MS material (higher than ducting material) for air balancing. Frame: High quality Stainless Steel sheet (Grade 304/316L) of thickness 16 G depending on size Frame shall be made of 125mm depth and standard flange height of 25mm. Blades shall be single skin ridge shaped blade constructed out of 16G thick S.S sheet as standard.
Pressure relief damper for kitchen exhaust duct. In case of pressure build up in the kitchen, the damper shall release the pressure to the atmosphere. Needs to fixed on the exhaust duct near the exhaust fan with all accessories, supports, etc. Shall be made of 16 G GI of the following sizes.
MS duct insulation with Al. Foil faced fibre glass wool 25 mm thick, 32 kg /m3 density
Supply, installation, testing and commissioing of Emergency Lockable Push button station for the above, Fire rated type with required GI angle iron support
Supply, installation, testing and commissioing of Emergency Lockable Push button station cabling for the above, 3 core 1.5 square XLPE copper armoud fire rated cable length shall be 100rmt between motor to Push button
Supply, installation, testing and commissioing of MS channel support with two coat of enamal painting for Unit additonal supports, Support shall be with cushy foot mounting or spring mounting as per the manufacter standard
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 6 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level < 60DB for (Door Ht. - 3.5 mtrs.)
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 4 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level < 60DB for (Door Ht. - 3.5 mtrs.)
Indoor Air quality testing (IAQ testing) for Parameter Such as VOC, CO2 and Bacteria Count After the installation of HVAC indoor units
VARIABLE REFRIGERANT FLOW UNITS :
(100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant
Supply & Installation of VRV /VRF airconditioning system comprising of Modular type high efficiency Twin Rotary Multiple Compressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below:
The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal.
All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint.
Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system
All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC/VRF vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF indoor and outdoor units and same to be located in a specific location as per client requirement.
Factory acceptance test to be conducted for all the units and cost of the same to be included
Testing tools and instruments of approved make and required quantity tobe maintained by Contractor
Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations
INDOOR UNITS / Ms Stands / Gas
Indoor Unit (IDU): Cooling type All the units should be supplied with Cordless remote control. The following Indoor unit capacities are required for each type of Room. Drycontact should be considered for Auto change over,failure status,overload sequencing etc..
Ductable units
Serving Area: 3TR 4-Way Cassette unit for BMS Room
Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration
Filling, testing, commissioning including topping up of R410 A Refrigerant.
REFRIGERANT PIPING & REFNET JOINTS
Insulated Refrigerant piping between the indoor units and the outdoor units with minimum pipe thickness of 1.6 mm. The Route length of Refrigerant piping between the outdoor units & Indoor units shall be as per the drawings furnished. The price quoted shall include liquid receiver, on-line accumulator, oil separator & other safety devices for required for total nos of circuits, if required for long distance and first charge of refrigerant & oil for the complete system including piping length required.
All refrigerant pipes shall be of hard drawn pipes in straight lengths shall be used. Wall thickness of all piping shall be 16 guage, 1.6 mm thick
Thick Thermal Insulation of VRV/VRF piping should be Closed cell Elastomeric Nitrile Rubber Insulation. Thermal conductivity of the insulation material shall not exceed 0.035 W/mºK at an average temperature of 0ºC.The product shall have temperature range of -50 ºC to 104ºC. The insulation material shall be fire rated for Class O as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch. The density of core Insulation shall be 40 to 60 kg/m3. The Insulation shall be factory finished with Co-extruded UV polymer flexible covering with fire resistance of ASTM E84. Water Vapour permeability as per ASTM E96 for the Jacket Materials < 0.05 perm in. UV Resistance (Artifiacial Aging) of the Jacket Material should be complying to ASTM G153.
34.3mm OD (insulation =19 mm thick)
28.6mm OD (insulation =19 mm thick)
22.2mm OD (insulation =13 mm thick)
19.1mm OD (insulation =13 mm thick)
15.9mm OD (insulation =13 mm thick)
12.7mm OD (insulation =13 mm thick)
9.5mm OD (insulation =13 mm thick)
Imported fittings like Y-Joints and headers etc as per the layout( additional supports should consider for both ends of the Y joint)
Electrical Cable between Isolator to ODU.Suitable size copper flexible cable with necessary earthing insulation Note:Cable from Electrical panel to isolator excluded in VRV vendor scope.same should capture in Electrical vendor scope. Cable from Isolator to ODU is part of VRV Vendorscope.
Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unit through PVC Conduit. Control cabling between the indoor unit, outdoor unit. The cables shall be armoured copper cable and shall be clamped to the wall / truss heavy duty GI clamps.
size:150x 50mm
size:300x 50mm
Supply, and installation insulated CPVC medium class Condensate drain piping with 8 kg/cm2 density, cut to required lengths and installed with all solvent joints, providing and fixing the necessary fittings like flanges,elbows tees, reducers, etc. Supporting arrangements as per site conditions. The rate quoted shall include the cost of nitrile rubber insulation for pipes running in unconditioned space of 9 mm thick.
32 mm dia
25 mm dia
DX HI-WALL SPLIT UNIT
Supply, Installation, Testing & Comissioning of factory made Hi wall mounted minimum 5star rating R32 gas Type Air conditioner units complete with centrifugal blower cooling coil etc., enclosed the insulation along with matching air cooled condenser with Rotary compressor all in with microprocessor control & Remote Control, Stablizer including gas charging, Supports for outdoor units, Safety controls, Power cabling and refrigerant piping between indoor and outdoor units and drain piping, etc. Units are included with all Refrigeration Controls .Refrigerant pipe shall be included with Tubular pipe insulation. including Minor civil works required if any. Cost Inclusive of Indoor & Outdoor unit Stand.
2.0TR Split AC unit with Inbuilt drain Pump for Office, Gate office area & UPS Room
1.5TR Split AC unit with Inbuilt drain Pump for Gate Office
1.0TR Split AC unit with Inbuilt drain Pump for
SITC of Soft drawn copper pipe with suitable suction line & liquid line pipe. The suction & liquid line shall be insulated with 13mm thick sleeveless nitrile rubber insulation.The rate shall be inclusive of Electrical & Control cable between IDU & ODU & MCB ( Provided by others) to ODU etc)- R 410 A Refrigerent should be consider
Copper Pipe for 2.0TR Split AC (Gas +Liquid Line)
Copper Pipe for 1.5TR Split AC (Gas +Liquid Line)
Copper Pipe for 1.0TR Split AC (Gas +Liquid Line)
Battery Room Exhaust
1000 Cfm - 15 mm external static inline fan with Flame / Explosion proof type all necessary supports. Battery room exhaust.
Multi sensor with sequential timer suitable control panel to operate Battery room exhaust fan at regular 2hrs interval fan run 5.0 minutes and when increse the Hyderagen level above 1% switch ON the fan. Controller shall have bypass mode to switch ON / OFF manually with necessary control wiring. panel shall provided with BMS compartability via Modbus over RS485.
FIRE PROTECTION SYSTEM WORK
FIRE PUMPS AND ACCESSORIES
2850 lpm at 120 m Head
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required. a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 2850 LPM against a total head of 120 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring, etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. Suitable HP,1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. c. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dynamo, solenoid switches etc. d. Diesel engine's day oil tank shall be of capacity sufficient to hold fuel up to 6 hrs of engine operation and mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre filter, after filter etc.First fill of all consumables including grease, lubricants, oil and diesel fuel. Contractor shall also refill all the consumables after successful testing at the time of handing over the system. e. Exhaust system having flexible metallic mufler, 150mm dia MS heavy pipe extended upto 10m height outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition.
f. Dash board consisting of the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency Stop and all other protection equipments as per specification, stop solenoid for auto stop in the event of fault with audio indications, g. 12 V / 24 V, storage battery, maintenance free tape, 180AH rating. MS fabricated common base plate, coupling guard, foundation bolts, etc., as required. h. Positioning the Diesel Engine Driven Fire Pump over cement concrete foundation using suitable size anti vibration mounting arrangements. i. Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer All works including conveying, fixing and incidental charges, etc., completed as per standard specification and as directed by the PMC/Employer. LOCATION: PUMP ROOM
2850 lpm at 120 m Head
180 lpm at 120 m Head
Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency cicumstances, coupled with 11 KW / 15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the PMC/Employer. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts, with anti vibration pads. etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Post Office Red / Fire Red Paint shall be as per specification/drawings complete as directed by the PMC/Employer. LOCATION: TERRACE FLOOR
900 lpm at 40 m Head
PIPES WORK
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
15 mm dia
50 mm dia
80 mm dia
100 mm dia
Providing, laying, testing and commissioning of Centrifugally cast (spun) Ductile Iron pipe with tyton jointed class "K9" confirming to IS 8329 with class K12 fittings confirming to IS 9523 including metallic zinc coating and finished layer of bituminous paints, fittings, elbows, nuts, bolts, gaskets etc. in ground including excavation & providing cement concrete block as supports like anchor block / thrust block, concrete bedding etc. of following sizes complete as required and as per technical specifications. NOTE: 1.All Above ground Hydrant pipe headers/riser shall be worded indicating the direction of the flow and its purpose such as "TO RISER NO.1" as per PMC/Employer /CFO requirement etc. 2.one coat metal primer and two coat Post Office Red / Fire Red as directed by PMC/Employer painting including conveyance, all incidental charges. 3. The pipe shall not be less than 1.0 m below ground level at any point. 4. Laying and Jointing of DI pipes and fittings shall be done as per IS: 12288 and manufacturer’s recommendations. 5. M.S to D.I Flanged connection as per IS 8329 LOCATION: EXTERNAL HYDRANTS SYSTEM
4mm thick Wrapping and Coating Anti-Corrosive Treatment for under ground MS pipe having one coat of anti-corrosive metal primer, one layer of asphalt tar tape wound over the MS pipe as per standard methods as per standard specification as directed by the PMC/Employer.
100mm dia
80mm dia
VALVES
Supplying, fixing, testing & commissioning of Double flanged Sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 / IS 780 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, ALL FLOORS
200 mm dia
150 mm dia
100 mm dia
Supply, lnstallation, Testing and Commissioning of Tamper Switch for Butterfly valves with BMS compatible of the following diameters complete with all necessary accessories, the tamper switch shall be provided with potential free contact with 2 nos. NO/NC as per specification/drawings and as directed by PMC/Employer. LOCATION: SPRINKLER RISER TAPPING AT EACH FLOOR
150 mm dia
Supply, lnstallation, testing and Commissioning of Male/ female screwed end full way lever operated forged brass Ball valve of PN 16 rating brass body with forged brass hard chrome plated ball & teflon seat, with (threaded joints) complete as required. including necessary teflon tape etc complete as per specification as specified inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: ALL FLOOR
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
Supply, lnstallation, testing and Commissioning of Male/ female screwed end full way lever operated forged brass Ball valve of PN 20 rating brass body with forged brass hard chrome plated ball & teflon seat, with (threaded joints) complete as required. including necessary teflon tape etc complete as per specification as specified inclusive of all accessories required for satisfactory installation as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
Providing, installation, testing and commissioning of non-return valve of PN 16 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM & ALL FLOOR
250 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 150 mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer LOCATION: PUMP ROOM, SPRINKLER RISER
Providing, installation, testing and commissioning of Stainless Steel body Y- strainer screen fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with Stainless Steel flange. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, TERRACE
300 mm dia
150 mm dia
Supplying and fixing of Air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM, HYDRANT RISER AT TERRACE
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved pilot operated Pressure relief valve - of Ductile Iron body,Brass trim,Buna-N Synthetic Rubber with Direct Acting - Precise Pressure Control,Drip Tight Closure,drain arrangement. It shall have adjustable setting in range suitable for operating range of the pump. The relief valve outlet shall be led back to the tank. All accessories nuts, bolts, washer, connector and pipe fittings etc. as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM
Providing and fixing UL listed Pressure reducing valve set for Sprinkler system comprising of 1 No pilot valve,2 Nos C.I Butterfly valves on inlet & outlet, 1 No. UL listed pressure reducing valve with flanged connection, 2 Nos Pressure gauge on inlet & outlet. The complete system is tested to a pressure not less than 18 Kg/Sq.cm and suitable to reduce the pressure upto 3.5 Kg/Sq.cm) Including flanges/ unions, nuts, bolts and washers complete as required as per specification/drawings and as directed by PMC/Employer. NOTE: The PRV shall be installed in an accessible location. Inlet Pressure: Max. 12 Kg/Sq.cm Outlet Pressure: 9.5 Kg/Sq.cm LOCATION: PUMP ROOM FOR ICV
200 mm dia (Brass Housing - PRV)
Supply, lnstallation, testing and Commissioning heavy duty floating flange EPDM rubber expansion joint with unit control (tie rod & gusset plate) as per manufacturers specifications of standard length complete with all accessories tested to a pressure not less than 15 Kg./sqcm including rubber gaskets, flanges, nuts, bolts & washers complete as required as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM
200 mm dia
100 mm dia
80 mm dia
65 mm dia
Providing & fixing bronze Globe valve, PN16, conforming to IS 778 screwed in bonnet, Bronze body, disc & stem union flanges, washer nuts & bolts, rising stem, connectors, adapters etc. complete, high quality PTFE gland packing with necessary unions, complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ALL FLOORS
15 mm dia
20 mm dia
25 mm dia
Providing & fixing bronze Globe valve, PN 20, conforming to IS 778 screwed in bonnet, Bronze body, disc & stem union flanges, washer nuts & bolts, rising stem, connectors, adapters etc. complete, high quality PTFE gland packing with necessary unions, complete as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM
15 mm dia
20 mm dia
25 mm dia
INSTRUMENTATION
Supply, erection, testing and commissioning of suitable Pressure Switch of approved make including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the PMC/Employer. NOTES: Adjustable type pressures switches suitable for operating with hydrant, water curtain & sprinkler systems for working pressure of 18Kg/cm² pressure including electrical wiring complete as required. Vendor also need to submit the calibration certificate of Pressure switch. LOCATION: PUMP ROOM
Supply & installation of Pressure gauge(suitable for working pressure of (0-20 Kg/cm2(g)) of Stainless Steel with 6 inch phenolic dial (white dial with black numerals), 316 SS Bourdon tube, nylon movements and micrometer type adjustable aluminium pointer with accuracy of +/-0.1% of span including accessories like siphons for steam services, snubbers for pump discharge applications and chemical diaphragm for corrosive and oil services and name plate, etc. Material of accessories shall be SS. IP65 degree of protection for enclosure. Over range protection shall be 50% above maximum pressure. Armoured capillary of 15 M shall be provided as per specification. LOCATION: PUMP ROOM, ALL FLOORS FHC
Supply, lnstallation, testing and Commissioning of FM approved Venturi Type Flow Test Meter on Test Line to measure 150% of pump flow and suitable for mounting on 150 mm dia pipe as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM
HYDRANT ACCESSORIES
Supply and fixing of Fire fighting application oblique type Single Headed Stainless Steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E” as per BS-10 standard, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the PMC/Employer LOCATION: ALL FLOORS FHC SHAFT
Supplying and fixing Single Headed External Yard Hydrant Valve with 1 No. 63 mm dia instantaneous FM Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Stainless Steel cap and chain as required : LOCATION: EXTERNAL YARD HYDRANTS
Supply, and fixing in position of Fire Fighting Application 63mm dia Stainless Steel Short length Branch Pipe with hexagonal type spray nozzle of 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS
Supply, and fixing in position of Fire Fighting Application RRL Type-A Hose confirming to IS 636 of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel (Grade 304) male and female instantaneous fire fighting special coupling as per IS 901 as directed by the PMC/Employer Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum painted in post office red conforming to IS 884 with 20mm dia braided thermoplastic hose as per IS 12585 of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any approved make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the PMC/Employer. LOCATION: ALL FLOORS FHC SHAFT
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer NOTE: 1.16 swg. with glass fronted ( 4mm thick glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm 2.Floor mounted / Wall mounted hose cabinets shall be provided with minimum 1 m high structural support legs of ISMC 100 as per the standard drawing. 3.Canopy (sloping top) is required for hose cabinets to be located outdoors. 4.The word “fire”, in 150 mm letter size in red, shall be painted on the cabinet glass. 5.The cabinet shall be provided with clamps for holding branch pipe, nozzle and hose reel where applicable. 6.Provision to keep one key and one hammer in glass covered recess on the side of the cabinet shall be made. 7.The colour shall be uv resistant fade proof integral type suitable for external atmosphere. LOCATION: IINTERNAL & EXTERNAL HYDRANT SYSTEM
Providing & fixing lockable Indoor type Fire Hose Cabinet, frames fabricated from 40 x 40 x 5 angle iron sections and 16 gauge MS sheet with glass door (with M.S. frame) and locking arrangement, suitable to accommodate landing valves, 2 nos. 15 m long hoses, first-aid hose reel and branch pipe nozzle & fire mans’ axe. The cabinet frame shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade of as required (Approx. 1.5 m (high) x 0.9 m (wide) x 0.6 m (deep) ). The item shall be complete of MS housing with front door Colour/shade of Paint shall be as per specification/drawings and as directed by PMC/Employer . LOCATION: EXPOSED FHC SHAFTS
Supplying and fixing standard Fireman Axe with heavy duty insulated rubber handle as per IS: 926 with clamps as per specifications LOCATION: ALL FLOORS FHC SHAFT , EXTERNAL YARD HYDRANTS
Supply, erection, testing and commissioning of Fire Fighting Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements .so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers.. LOCATION: EXTERNAL
(a) 2 way-100 mm dia G.I. Pipe (Drawout)
(b) 4 way - 150 mm dia G.I. Pipe (Inlet)
Providing & fixing SS cabinet (to enclose Fire Brigade and draw-out connection as per Item above) fabricated from 16 g SS 304 sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx. 0.6 m x 0.6 m x 0.45 m) LOCATION: EXTERNAL
Supply, erection, testing and commissioning of following sizes of CI flanged end Heavy Duty Foot Valve as per IS 4038/1979 including all accesories, such as, MS flange of table ‘E’ as per BS-10 standard, gaskets, bolts & nuts, etc., installed at end of 100/ 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the PMC/Employer. LOCATION: UNDER GROUND FIRE WATER & DOMESTIC WATER TANK
Size: 100 mm dia
Supplying and fixing Orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required as per specifications. NOTE: The bore of the orifice shall be designed by the Contractor in order to get hydrants valve outlet pressure of 3.5 kg/cm2”. LOCATION: FHC SHAFTS AS REQUIRED , EXTERNAL YARD HYDRANTS
Supply & Fixing of " J " type hooks supports made of 25 mm dia MS pipe to support 2 Number 15 m long hoses and 1 Number short branch pipe. Cost should be inclusive of required anchor fastener, nuts, etc as per specifications LOCATION: FHC SHAFTS
AUTOMATIC SPRINKLER SYSTEM
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required NOTE: Post Office Red / Fire Red color paint shall be as per specification/drawings and as directed by PMC/Employer LOCATION: PUMP ROOM
200 mm dia
Supply, lnstallation, testing and Commissioning of UL Listed Zone/Floor Control Valve flanged end with fitting, suitable for working pressure of 18kg/sq.m including 50 mm Inspectors test drain valve assembly complete with test bronze valve, bronze sight glass, sectional drain valve, union with pressure gauge, electrically operated flow indicating switch (vane type) of following diameter with threaded connection with flexible full bore paddle & NO/NC contact terminals with all accessories and necessary wiring all complete strictly as per specification/Drawing as per specification/drawings and as directed by PMC/Employer. LOCATION: SPRINKLER SYSTEM ALL FLOORS
Dia 150 mm dia
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: ALL FLOORS COMMON AREAS
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Upright type, Standard Response, Quartzoid bulb type sprinkler Coverage Area 9 sq.mtr, teflon tape, lock tite solution with required accessories etc. complete as per specification/drawings and as directed by PMC/Employer. LOCATION: GROUND AND ABOVE FLOORS
Supply, lnstallation, testing and Commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. LOCATION: FOR ALL PENDANT SPRINKLERS
Providing & fixing spare sprinkler MS cabinet fabricated from 16 gauge MS sheet (duly painted over a coat of primer) with full front glass door & locking arrangement with suitable shealves for keeping spare sprinkler of each type (as desired below) & two nos spanner properly fixed in shelves. Cost shall be for individual cabinet comprising of spare sprinkler stored as indicated below :
UL Listed/FM Approved 15 NB, with 68°C. temperature rating for Sprinkler bulb and 57°C. for Cover Plate, K-Factor 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler adjustable royal flush Concealed sprinkler
UL Listed/FM Approved 15 NB, 68 deg. , K-Factor 5.6 (80), Upright type, Standard Response, Quartzoid bulb type sprinkler
UL Listed/FM Approved 15 NB, 68 deg. K 5.6 (80), Pendant type, Standard Response, Quartzoid bulb sprinkler
CLEAN AGENT BASED FIRE SUPPRESSION SYSTEM
CLEAN AGENT BASED FIRE SUPPRESSION SYSTEM Assumed Areas to be protected:- IBMS SERVER ROOM AT FIRST FLOOR & HUB ROOM GROUND FLOOR NOTE:- 1-System to be designed with Individual Risk with Main + Standby System 2-100% online Stand-by cylinders of clean agent shall be provided for restoring the area protection after discharge of main bank of cylinders. 3-Clean Agent Gas based suppression system shall be halon Free.
Design, Supply, Installation, Testing & Commissioning of CCOE/PESO Approved UL/ FM/ VDS Listed agent FK-5-1-12 or equivalent Cylinder and Valve Assembly,120 Ltrs Ltr seamless cylinder capacity, Liquid at site (fill density not more than 0.89Kg/ litre), pressurised to 25 / 42 bar along with Hydraulic UL/ VD Flow Calculations for the Suppression areas, and vetting of the Software from the OEM Factory Engineer as per specification/drawings and as per specification/drawings and as directed by PMC/Employer . Below compliance are mandatory to comply with PESO, Gas cylinder rule and compressed gas cylinder rule. a) PESO License for Valve & b) PESO License for Cylinder
The fire suppression agent FK-5-1-12 or equivalent . The Hydraulic software report should have the dead volume agent quantities reflected for IBMS Server Room as per UL 2166 testing and approval standard as per specification/drawings and as directed by PMC/Employer .
Supply, Installation, Testing & Commissioning of Tank Bracket Assembly complete with C Channel Stand and Supports for above Cylinder as per specification/drawings and as directed by PMC/Employer. The Price Shall include MS Fabricated Floor Supported Cylinder Support Stand, wherever Required complete with 1 coat of Primer and 2 coat of Black Enamel Paint.
Cylinder Bracket with C Chanel from OEM supply
MS Fabrication floor support for cylinder stand 150mm above floor level with 1 coat of primer and 2 coat of Black Enamel Paint.
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Discharge hose with Manifold Check Valve (Check Valve if More than one Cylinder in Bank) for above Cylinders, complete with Listed Actuation Hose, Swivel, stainless Braided, 24in , 1/4in Female, Male adaptor (1/4" BSPT x 1/4" BSPP), Male elbow (1/4" NPT x 1/4" BSPP ) & Accessories as required as per specification/drawings and as directed by PMC/Employer.
Supply, Installation, Testing & Commissioning of UL/ FM/ VDS Listed Electrical Actuator with placement indicator switch for Master Cylinder as per NFPA requirement and as per specification/drawings and as directed by PMC/Employer.
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Local Manual Actuator as per specification/drawings and as directed by PMC/Employer .
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Pneumatic Actuator Shipping Assembly with actuation hose & Elbow as per specification/drawings and as directed by PMC/Employer.
Standard Nozzle 15mm
Standard Nozzle 20mm
Standard Nozzle 25mm
Standard Nozzle 32mm
Supply, Installation, Testing & Commissioning of Warning Sign Board of of size 150mm X 400mm with Marking "GAS DISCHARGE. DO NOT ENTER".Shall Operate on 24 V DC, Driven Through Gas Release Panel. (for use outside room)as per specification/drawings and as directed by PMC/Employer .
Supply, Installation, Testing & Commissioning of Warning Sign Board of of size 150mm X 400mm with Marking "GAS DISCHARGE. EVACUATE IMMEDIATELY". Shall Operate on 24 V DC, Driven Through Gas Release Panel. (for use inside room) as per specification/drawings and as per specification/drawings and as directed by PMC/Employer .
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Cylinder Low Pressure Switchs per specification/drawings and as directed by PMC/Employer.
Supply, Installation, Testing & Commissioning of UL/ VDS Listed Cylinder Discharge Pressure Switch, Shall be install on the piping after discharge hose as per specification/drawings and as directed by PMC/Employer.
Supply, Installation, Testing & Commissioning of Piping & Manifold as required, Sch 80; ASTM A106 Gr B, as per flow calculations for the specific hazard volume and stand to hold,position & Support the Manifold and Piping properly including Pressure testing for piping with nitrogen as per NFPA 2001 as per specification/drawings and as directed by PMC/Employer.
Supply & Installation of Manifold fabricated out of Sch 80 pipe with 150 mm pipe with 1 port main and 1 port standby cylinders. The Manifold should include all the support and fittings.
Supply, Installation, Testing & Commissioning of Seamless Pipe Sch 40 distribution pipe along which shall include all the support and fittings for pipes like U Clamps, Elbows, Sockets, Reducers, Tees, Flanges, Fasteners etc.for pipes for 7 cylinder system as per specification/drawings and as directed by PMC/Employer.
Supply & Installation Structural support for manifold along with fabrication of cylinder support stand,angle, channel and pipe support along with fittings to make system complete
Supply, Installation and commissioning of UL/ VDS/ FM listed Single zone gas release panel facility to connect manual abort/ release switch. The panel shall provide potential free contacts for first knock, second knock, trouble/ fault/ VDS status. The Panel shall be including 2 Core x 1.5 mm², Multistranded AT Copper, ZHFR Armoured cable, RED in Colour. The cable shall be laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling, required fittings, jointing, bracing, clamping, fastening.The panel shall be complete red color housing , monitored power supply unit, battery charger and batteries as per specification/drawings and as directed by PMC/Employer .
Supply, installation, testing and commissioning of Manual abort stations, shall be fitted with transparent hinged covers to avoid possibility of accidental operation. The abort will be monitored simultaneously by the fire alarm or BMS system as per specification/drawings and as directed by PMC/Employer .
Supply installation, testing and commissioning of Manual release station , shall be fitted with transparent hinged covers to avoid possibility of accidental operations. The Release switch shall be monitored simultaneously by the fire alarm or BMS system as per specification/drawings and as directed by PMC/Employer .
Towards Conducting Room Integrity Test : Door Fan test to meet the Requirements of the NFPA 2001, and predicting the efficacy of the Protected Area Enclosure from the perspective of Fire Suppression as per specification/drawings and as directed by PMC/Employer.
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/ EMployer.
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the PMC/ EMployer.
Supply, laying, termination, testing and Commissioning of armoured FRLS control wires 2C x 2.5 sqmm made of PVC insulated copper conductor, PVC sheathed,confirming to IS 1554 etc. shall include all fittings, jointing, glands, lugs, bracing, clamping, fastening, chasing, termination and testing. complete as per specification/drawings and as directed by PMC/Employer. For Detectors & Hooters
FIRE EXTINGUISHER SYSTEM
Supply, lnstallation, testing and Commissioning of Carbon Dioxide (CO2) type Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by PMC/Employer .
Supply, lnstallation, testing and Commissioning of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the PMC/Employer .
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 6 kg Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by PMC/Employer .
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 9 kg Fire Extinguisher with all required accessories, conforming to IS:15683, with ISI marked approved fitted with required accessories including flool mounting stand and all accessories required as per specification/drawings and as directed by PMC/Employer .
Supply, lnstallation, testing and Commissioning of Mechanical Foam type (AFFF media) 9 Liter. cylindrical shape fire extinguisher with gas cartridge, hose and all required accessories, complete as per IS:15683 - trolley mounted type for portable use as per technical specifications with all the necessary accessories as required for complete installation shall also be included as per specification/drawings and as directed by PMC/Employer .
Supply, lnstallation, testing and Commissioning of Mechanical Foam type (AFFF media) 45 Liter. cylindrical shape fire extinguisher with gas cartridge, hose and all required accessories, complete as per IS:15683 - trolley mounted type for portable use as per technical specifications with all the necessary accessories as required for complete installation shall also be included as per specification/drawings and as directed by PMC/Employer .
Supply, Installation of Floor mounted bucket stand with GI buckets to hand 4 nos. of 9 ltrs buckets sand filled (as per IS: 2546). The stand shall be 5'(L) x 3'(H) x 2"(W) made out of 30 x 300 x4mm MS angle frame duly coated with 2 coats of red oxide primer & 2 coats of red finish paint as per specification/drawings and as directed by PMC/Employer.
Supply, lnstallation, testing and Commissioning of ISI Marked Wet Chemical Stored Pressure Type Fire Extinguisher, Capacity 2L, Fire rating 5F, Deep drawn cylinder body with Metal Skirt, Squeeze Grip CE marked Valve made of forged brass with nickel chromium plating and Stainless Steel Carrying and Operating Handles, In built pressure release device & NRV at pressure gauge mounting port, Polyvinyl Siphon Tube, Stainless Steel safety pin,Brass Nickel Chrome plated nozzle, High Quality Vinyl label, QR code for product traceability, Testing and Inspection - As per IS 15683:2018.( For Kitchen & pantry)
Supply, lnstallation, testing and Commissioning of 2 kg Fire Extinguisher UL listed FE-36 (HFC-236 fa) gas Electrically nonconductive, non corrosive, colorless and non-residual clean agent Suitable for Class A, B, C, and electrical fires approved with US EPA (Environmental Protection Agency), listing under USA Signification New Alternative Policy ( SNAP) & also approved by (Environmental Protection Agency) listing under USA Signification New Alternative Policy SNAP) & also approved by UL, compliant with ASTM -D6541-11. low toxicity, also its replacement for Halon 1211, Halon 1201. Controllable discharge mechanism with EPDM Discharge Hose with Specially designed Unique Nozzle, UGTS Pressure Gauge, Body Construction Deep Drawn with MIG Welding technology, External Pure polyester and Internal Epoxy polyester powder coated, Brass forged CE marked valves with safety pressure release mechanism, safety Pin is of SS material, and Welding Procedure approved by TPI with 6 G certification. Fire Class 1A:21B rating as per IS 15683 and ISI MARK.
Supply, lnstallation, testing and Commissioning of FE36 Automatic ceiling Mounted Clean agent Extinguisher with Ceiling mount accessories including nozzle(57 deg), pressure guage. ISI approved
ELECTRICAL PANELS, STARTER PANELS, CABLES, TERMINATIONS
FIRE FIGHTING PANEL-1
Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering , MS steel channels for panel mounting etc. complete in all respect, suitable for main fire pump, pressurization pump & set complete as per specification with following incoming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 55 bottom entry as required. Operation Logic shall be as per specification/drawings and as directed by PMC/Employer. LOCATION: PUMP ROOM
STARTER ISOLATOR PANELS
MV CABLE AND CABLE LAYING
“Supply, loading, transportation unloading and storages at site , shifting from storage place to site, laying, installation, commissioning of following sizes of Stranded Annealed Bare Copper Conductor , 950° for 3 hours Mica Tape Wrapped, Xlpe Insulation, Cores Laid up together, Fiber Glass Tape Wrapped, LSZH Inner Sheathed, GI Wire Strip Armoured, LSZH Outer sheathed Fire Survival Cables of 1.1 KV grade conforming to BS 7846 amended up to date, and cable should pass circuit integrity test as per BS 6387. LOCATION: PUMP ROOM & TERRACE
240 Sq.mm x 3.0C Cu. Fire Survival Cable
185 Sq.mm x 3.0C Cu. Fire Survival Cable
50 Sq.mm x 3.0C Cu. Fire Survival Cable
25 Sq.mm x 3C Cu. Fire Survival Cable
MV CABLE TERMINATION
Supplying and making Flame Proof end termination with brass double compression Flame Proof gland and Copper lugs for following sizes of XLPE insulated and PVC sheathed Copper conductor cable of 1.1 KV grade as required
3c 240Sqmm
3c 185Sqmm
3C 50 sqmm
3C 25 sqmm
CABLE TRAYS
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE
GI Hot Dip 16 SWG Cable Tray with 150mm width and 50mm height
GI Hot Dip 16 SWG Cable Tray with 300mm width and 50mm height
GI Hot Dip 16 SWG Cable Tray with 600mm width and 50mm height
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. LOCATION: PUMP ROOM & TERRACE
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. LOCATION: PUMP ROOM & TERRACE
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. LOCATION: PUMP ROOM & TERRACE
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
600 mm width X 50 mm depth X 2.0 mm thickness
STATUTORY APPROVAL
Taking STATUTORY APPROVALS (Liasioning) of all fire fighting system from local fire authority and any other relevant statutory authority at initial & various other stages of works, including preparation of report / drawings as per fire authority. Contractor shall include cost of all liaison works which are not explicitly mentioned above but are mandatory to have fire authority approval (any statutory charges will be reimbursed as per actual upon production of the invoice / challan).
MISCELLANEOUS
Supply, Installation, Testing & Commissioning of Triple Spur Gear, Top & bottom hook with safety latch hand hoist, 3 Ton capacity, Swivel for Top & Bottom block Chain pulley block (12.0 m lift) with long travel rail track (40 mm sq. bar), moving or cross girder, all three motions electrically operated by with all accessories as complete The chain blocks should be tested to a proof load of 1.5 times the working load limit. It should be light weight & sturdy for ease of handling. Chain pulley blocks must confirm to IS 3832 and Safety approval from reputed national / international agencies along with test certificate. LOCATION: PUMP ROOM
Supply, Installation, Testing and commissioning of Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like Metal/Plastic Pipes, Duct & Cable trays with combustibel/Non Combustible insulations. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method for seismic zone 3. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The system shall be UL listed & classified and product shall bear the UL and FM approval logo on the packing. A firestop submittal shall be produced by manufacturer , in accordance with approved passive fire protection method statement, for technical approval. Firestop installation shall be done by supplier Accredited Firestop Speciality Contractor or by certified installers inline with UL system test certificates. Firestop Speciality Contractor needs to submitt work completition certificate along with installation report with supplier warranty certificate for periodic inspection & maintenance purpose. The gaps around combustible penetrants like plastic pipes or ducts with insulation shall be sealed with an appropriate material as recommended by the supplier. LOCATION: ALL FLOORS FHC, PHE SHAFT, ELECTRICAL AND ELV SHAFTS & OPENINGS
Supply, Installation, Testing and commissioning of High performance Intumescent and Acrylic Firestop sealant that helps protect combustible penetrations for up to 2 hours fire rating in accordance to UL 1479 (American) standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. Movement capability approx.. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241meeting LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. LOCATION: ALL FLOORS FHC, PHE SHAFT, ELECTRICAL AND ELV SHAFTS & OPENINGS
Providing & Fixing First Aid Box complete with all First Aid Medicines
PLUMBING WORKS
Note : 1. "Procurement of items with astehetic value and visibility shall be on prior approval of architect and project office/PMC for specific arae of application."
PART-A SANITARY FIXTURES & CP FITTINGS
Supply, Installing, testing and commissioning of white colour vitreous European water closet wall hung with seat cover and twin flush fittings, with all internal parts of the open cistern for efficient functioning, with back inlet P or S trap by using conversion bend. The closet is mounted with GI Rag bolts and nuts, with 110 mm dia straight type syphon UPVC WC pan connector with neoprene rubber ring, 15 mm necessary valves. The cost shall include accessories of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour including lead and lift charges, all complete as per specifications..
EWC - ELEMENT PLUS Closet With SC Seat - White Cat. No.: 92566 (P-21.5)
Cistern - CONCEALO NEO CISTERN FULL FRAME & DRAIN SET - QF WITH PUSH BUTTON Cat. No. 525063
Flush plate Cat.No.525018
Supply, installing, testing and commissioning of under counter wash basin, 15mm dia sensor based ac & dc Pillar cock with waste coupling, 32mm dia CP bottle trap with extension pipe, supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges all of approved make etc., (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning ) complete.
Wash Basin - Cat. No.: Cat. No.: 10049 Size: 56 x 45 cm
Pillar cock - Cat. No.: Cat. No.: F240011CP ECO SENSOR FAUCET AC & DC
Angle cock - Cat. No.: F850077 Angular Stop Cock with Wall Flange
Bottle trap - F850072 300 mm & 250 mm
Cat. No.: F860010 Waste Coupling 32mm SS (Full Thread)
Receiving, Storing ing, installing, testing and commissioning White Vitreous large flat back urinal with sensor flush valve supported by CI/GI bracket duly painted, including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges, automatic flushing systems for urinal to ensure flushing only immediately after use, comprising of all plumbing, electronic and electrical items. , CP wall flange, infrared photo cells (Sensor), eyes electrically operated solenoid valve, step down transformer/equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting/chasing and making good, as required.
Urinal - Cat. No.: 96014 Size: 30.5 x 38 x 65 cm
sensor flush valve - Cat. No.: F860083 Urinal Sensor Flushing Battery Operated
Fixing & testing of curved shaped urinal partition with frosted glass including providing & fixing concealed CI bracket, cutting and making good.
Urinal partition- SU81OSC-C-STD-CR - Glass tk - 8mm-450/300 x 900
Supply, installing, testing and commissioning of handicapped toilet White color wall haung European water closet with dual flush cistern with necessary pan connecter, bend,checknut, angle cock, solid seat cover with polythene buffer and flap, CP flanges etc.,(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete., EWC dual flush cistern - E8299 Regular Seat Cover, C0771 Cistern Set including Fittings (Tank Capacity : 4.5/3 L for flush, 4.5L for solid waste & 3L for urinal waste) including rectangular wall hung wash basin, 15mm dia Pillar cock with waste coupling, CP angle cock, 32mm dia CP bottle trap with extension pipe, grab bar, supporting bracket with necessary steel to support basin, 450mm long CP connection pipe and CP wall flanges all of approved make etc.,(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete.
EWC - ELEMENT PLUS Closet With SC Seat - White Cat. No.: 92566 (P-21.5)
Cistern - CONCEALO NEO CISTERN FULL FRAME & DRAIN SET - QF WITH PUSH BUTTON Cat. No. 525063
Wash Basin - Cat. No.: Cat. No.: 10049 Size: 56 x 45 cm
Pillar cock - Cat. No.: Cat. No.: F240011CP ECO SENSOR FAUCET AC & DC
Angle cock - Cat. No.: F850077 Angular Stop Cock with Wall Flange
Bottle trap - F850072 300 mm & 250 mm
Cat. No.: F860010 Waste Coupling 32mm SS (Full Thread)
Hinge rail x 2, Grab bar x 4
Supply, Storing, Installing, testing and commissioning of 15mm CP health faucet of approved make with necessary CP flexible hose 1000mm long nozzle,CP wall flange, CP angle cock etc., (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning )
Health faucet Cat. No.: F160192 Flora Health Faucet with 1.2 M SS Flexible Tube & Wall Hook
Angle cock - Cat. No.: F850077 Angular Stop Cock with Wall Flange
Supply, Installing, testing and commissioning of stainless steel sink with drain board, with 15m dia CP sink mixer, CP waste coupling, 32mm dia CP bottle trap with extension pipe, supporting CI bracket to support sink, and CP wall flanges, all complete set of approved make.
Sink-513535-KS Classic SBSD 37x18x8 (Glossy) with waste coupling
Angle cock - Cat. No.: F850077 Angular Stop Cock with Wall Flange
Bottle trap - F850072 300 mm & 250 mm
Cat. No.: F860010 Waste Coupling 32mm SS (Full Thread)
Cat. No.: F690058 Sink Mixer J Spout (Wall Mounted)
Supply, Installing, testing and commissioning of approved make CP brass long body bib tap accessories, including cutting & making good of walls etc.. complete with wall flange etc.,
, 2way bib cock:Cat. No.: F570006
Supplying, installing, fixing, jointing, testing and commissioning of SS Water Dispenser (100 LPH), Outlet of Hot, Cold , Warm with sensor taps (3 nos).
Model : Conway-NHC-100
Angle cock - Hindware Cat. No.: F850077 Angular Stop Cock with Wall Flange
Supply, installation and fixing of stainless steel toilet paper holder with SS scres on the wall.
Cat. No.: F880003 Paper Holder with Cover
Supply, installation and fixing of stainless steel body liquid soap dispenser with PVC rawl plug & C.P. brass screw complete as required. (Material : SS 304, Dispense : Foam soap, Battery : 4 x AA alkaline duracell, sensing distance : 5-9cm, Dispense volume : 1-2ml)
Make : -ES82AS
Supply, installation and fixing of stainless steel body paper towel dispenser with SS screws on the breakout wall. (Cabinet :18-8 stainless steel 304, Capacity: 450 (M & Z fold), 600 multifold)
Make : - EP19 Auto HRT Tissue
Supply and fixing of Wall mounted SS body Hand Dryer with SS screws on the wall. (Auto cutoff: 30sec, Sensor range : 12 cm - 15 cm, Hand dry time: less than 20 secs, Motor; Brush type, dual ball bearings, Speed:30,000 RPM, Rated power:1KW, Operation: Touch free infra red activation)
Make : Euronics - EH 250NW
Supply, installation and fixing of Robe hook with PVC rawl plug & C.P. brass screw complete as required.
Cat. No.: F880004 Robe Hook
Supply, iinstallation and fixing testing and commissioning of apparoved make electically operated storage water heater inner container made from copper or stainless steel including the remal instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, angle valve, connection hose installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete.
evano 25L (524446) -horizontal
Angle cock - Cat. No.: F850077 Angular Stop Cock with Wall Flange
PART-B INTERNAL SOIL AND WASTE WATER SYSTEM
Providing, Fixing, Jointing, Testing and Commissioning of Rigid uPVC Pipe for Soil, Waste Installation confirming to IS 4985 Class 3 PN 6 and fitting confirming to IS 7834. Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door). The pipes shall be running over slab (in -filling) / concealed in wall in areas such as toilets, kitchen etc. Cost shall be inclusive of providing and laying 1:2:4 cement concrete below the joints of pipe. Cost shall be inclusive of making maximum of 100mm X 100mm chasing in wall / floors for the pipe; making good the same using 1:1 cement mortar over the embedded pipes and fittings, complete as required. If running through ceiling level cost shall be inclusive of galvanized clamps, hangers, anchor fastners at maximum of 1m interval etc. as per specification.
40mm dia
50mm dia
Providing, Fixing, Testing and Commissioning of uPVC SWR (Type B) Pipe for Soil, Waste, Rain water System Installation confirming to IS 13592-1992 and fitting confirming to IS 14735:99 (Pipe Class B). Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door), Vent Cowls with brass mosquito proof . Cost shall be inclusive of Fixing / Supporting the Pipes at Wall / Ceiling level supported by galvanized clamps, hangers, angle brackets, anchor fasteners etc. as per specification.
75mm dia
110mm dia
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).
160mm dia
110mm dia
75mm dia
Providing, fixing and testing C.I multi floor trap with SS gratings of self cleansing design with arm and provision for connection C.I /G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. Multifloor trap 75 mm outlet with 100 mm inlet. (Include) Supply and fixing 110mm dia PVC "BOSS TEE" of 400mm long with 1 No of 40/50mm inlet, fixing over floor trap by penetrating core cut/cutout in RCC slab etc., complete
Supplying, fixing and testing 110 dia PVC 'P' trap with SS gratings for urinals with boss connection suitable as per piping detail with fixed in bed of cement concrete. etc., complete.
Providing and fixing heavy duty SS Floor Clean out with frame of approved design including setting in floor with cement motor to match with floor finish as directed by PMC/Employer. (Include) Supply and fixing 110mm dia PVC "BOSS TEE" of 400mm long inlet, fixing over floor trap by penetrating core cut/cutout in RCC slab etc., complete
Providing, Fixing, testing and commissioning in position PVC Clean Out with plug suitable for pipe diaMetre with a seal tight cover. Making proper connection with refined drip seal joints, bringing the same in proper condition and shape after placing it in right position complete as required and as per drawings.
110 mm Dia
75 mm Dia
Designing, Providing, fixing, jointing, testing and commissioning of Pre-fabricated HDPE Centralized Grease Separator NS-3 with BMS compatibility including cutter type submersible pump, medium duty cover, inlet outlet, overflow, sludge suction connection, excavation & backfilling of grease storage tank of cap minimum 200 liters including all accessories complete as required or as per manufacturer specification as and directed by PMC/Employer. suitable for below ground application, conforming to EN 1825 / DIN 4040-100.
200 mm dia
110 mm dia
pipes with suitable material, nominal reinforcement wherever required for all levels/ all height, after approval of PMC/Employer etc complete. Measurement shall be taken for the depth of holes in running Metre for specified diaMetre. Holes shall made by authorized approved agency. Sealing material and reinforcement shall be paid in relevant tender items.
150mm Dia
PART-C INTERNAL & EXTERNAL WATER SUPPLY
Supplying, fixing, testing and commissioning of approved make chlorinated polyvinyl chloride (CPVC) pipes, fittings SDR 11 ASTM CTS, for the following dia, pipes with necessary specials elbows, tee, reduce, plug, union, bend, couple, nipple, gate valve, check and wheel valve wherever necessary including labour below ground level(or) fixing on walls fully concealed to the proper gradient and alignment etc. all complete as directed by dept. Officers. (Internal DWS, RO & FWS)
25mm Dia
32mm Dia
40mm Dia
50mm Dia
Shaft, transfer & Terrace
25mm Dia
40mm Dia
50mm Dia
65mm Dia
80mm Dia
100mm Dia
External (inclusive of backfilling with excavated earth with proper compaction etc)
25mm Dia
50mm Dia
80mm Dia
100mm Dia
Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with suitable size brass valve adopter union, ferrule, nipple, rubber "O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification.
25mm Dia
32mm Dia
40mm Dia
50mm Dia
Supply ,Installing, testing and commissioning Air release valves confirming to IS standard 13039 with necessary flanges, nuts and bolts etc.,(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning.) complete.
25mm Dia
Supply, installation, testing and commissioning approved make CI Non - return valves conforming to IS:778 with necessary companion flanges, neoprene gaskets (10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. ( Sample should be got approved )
80mm Dia
Supply, installation, testing and commissioning approved make CI Y-type Strainer conforming to IS standard with necessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications.
80mm Dia
100mm Dia
Supply, fixing, testing and commissioning of CI body slim seal butterfly valves as per detailed specifications complete with vertical/horizontal liver operated unit with handle, companion flanges, gaskets, nuts and bolts etc., complete confirming to IS: 13095. The valve shall be suitable for a working pressure of 16.0 kg/sqcm.
65mm Dia
80mm Dia
100mm Dia
Supplying, installing, testing and commissioning approved make Brass pressure reducing station including pressure reducing valve ,3 Nos Isolation valves, 2 Nos Pressure Gauges with union, flanges etc., complete.
25mm Dia
65mm Dia
100mm Dia
Supply ,Installing, testing and commissioning of PN 16 mechanical type float valve with an isolation valve complete confirming to IS standards, necessary flanges, nuts and bolts etc.,(The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning.) complete.
25mm Dia - Fire OHT (Utility)
50mm Dia - Metro for UG sump inlet
80mm Dia - OHT for Flush & Mockup water
100mm Dia - Fire OHT
Supply, installing, testing and commissioning of Electromagnetic Flowmeter:- Operating Pressure: 12 bar, Type: Pulsed DC, Flow tube: SS 304, Coil housing: Fully welded Sheet Steel, Liner: Hard Rubber, Electrodes: SS 316, Grounding type: Rings, Grounding ring material: SS 316, Process connection : ANSI Class #150, Flange Material : CS, Area classification : Non-Hazardous, Cable entry : M20 x 1.5 with blind plug, Protection class : IP 67, Mounting : Horizontal/Vertical, Installation :Outdoor. Signal Converter:- Type : Microprocessor Based, Output : 4-20mA, Area classification : Non-Hazardous, Protection class : IP 67 & with all necessary fitting such as threaded pieces, unions pressure gauge, isolation cock, flanges piece for future removal, flanges / unions complete with all necessary testing charges and obtaining test certificates from authorities, on following size pipe lines (2no valves, 1 no. strainer shall be provided at inlet & outlet and cost shall be inclusive for the same). The meter shall comply to ISO 4064 standard, feasible for class B or Class A installation.
25mm Dia
40mm Dia
50mm Dia
80mm Dia
100mm Dia
Fabrication & fixing of hot dip galvanized GI puddle flanges fabricated out of GI pipes and GI plates and duly hot dip galvanized after fabrication. The puddles of various diameter shall be as shown the UG & OHT, rain water, domestic treated water, flush water, HVAC make up water storage, pump room dewatering,drawings
600 mm dia
450 mm dia
250 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
25 mm dia
Supply, Installation, of Manhole cover 60 X 60 cm Heavy grade with frame (For UG sump & OHT)
Supply, Installation, of PVC mould CI Steps for Sump
Constructing RCC valve Chamber of M25 Grade with Medium duty FRP cover 600mm x 600mm for sluice valve, i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5
1200 X 1500mm & 1500 mm deep
Providing, fixing, testing and commissioning of water meter confirming to IS 2372 - 1981, with direct reading dia in KL with all integral parts of gun metal or brass with neccesary fitting such as 2nos ball valve, 1no check valve, 1no Y-stainer, threaded pieces, unions and check nuts complete. with all necessary testing charges and obtaining test certificates from municipal authorities
50mm dia
PART-D EXTERNAL DRAINAGE & RAIN WATER SYSTEM
Supplying and fixing the following dia PVC (SWR) pipe with ISI mark confirming to IS 13952 :1992 - TYPE B for soil with relevant specials conforming to IS14735 including jointing with seal ring conforming to IS 5382 with leaving a gap about 10mm to allow thermal expansion fixing the pipes into valves with necessary wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necesaary connections to sanitary fittings etc.,complete in all respects and as directed by the departmental officers. as specified by the Consultant / Engineer-in-Charge at site inclusive of backfilling with excavated earth with proper compaction etc.
75mm dia
110mm dia
160mm dia
Supply and Delivery of DWC Structured Wall Polyethylene Piping Systems (Pipe with online/offline coupler and elastomeric sealing ring) with required specials non-smooth external annular corrugated and smooth internal surface (Double wall) (SN 8 Class) for non-pressure underground sewerage, drainage application generally as per IS-16098 (Part-2) type B.. as specified by the Consultant / Engineer-in-Charge at site inclusive of backfilling with excavated earth with proper compaction etc. (External)
160mm dia
200mm dia
250mm dia
300mm dia
400mm dia
600mm dia
Providing and fixing square mouth cast iron gully trap complete with RCC Chamber of M25 Grade 900 x 900 mm clear opening depth upto 2000mm i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5.150 x 150 mm size “P” trap including 450 x 450 mm double seal C.I cover with frame. Note : Cost shall include excavation dewatering and watering proofing of chambers as directed at site
Constructing RCC Inspection Chamber of M25 Grade with Medium duty FRP cover 600mm x 600mm for sluice valve, i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5
900 x 800 mm up to 900 mm deep
900 x 1200 mm up to 2500 mm deep
Construction of RCC catch basin of M25 Grade with Medium duty FRP cover 600mm x 600mm for sluice valve, i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5
Supplying and laying of RCC Hume NP4 Class conforming to IS:458, with collars and jointing cement soaked Hessian cloth and finished smooth the joint with cement mortar 1:1, including Earth work excavation for the required depth with dewatering if required, laying pipe, providing and laying cement concrete 1:3:6, 75mm thick at the side of joints to the required line, level and slope and backfilling etc., complete (For Road Crossing)
300 mm dia
PART-E PUMP ACCESSORIES
Supply, delivery, testing, commissioning of Vertical Multi stage Centrifugal Pump with suitable capacity 415V, 3-phase,50Hz motor and coupling with base frame having discharge capacity of 10 Cum/Hr against total head of 25m from all causes, with common starter panel, each starter consists of suitable MPCB, Contactor, Overload relay, Single Phase Preventer, Push buttons, LED on indicators, all are in Weather Proof box (IP55) and necessary suitable copper cables from starter panel to pump (Appx.20Mtrs/each pump) etc. Pumps shall be IE-3 class rated. complete with necessary accessories. The panel shall have 2nos incomers with auto changeover switch. The panel shall be compatible with BMS (MODBUS RS 485 / MSTP) Scope included auto level controller and cable between sump and OHT.
For Domestic water Lifting from sump to OHT
Each Pump capacity : 5.6 LPS
No of Pumps : 1 working + 1 working
Delivery head : 75 m
For STP treated water Lifting from sump to Flush OHT
Each Pump capacity : 4.2 LPS
No of Pumps : 1 working + 1 working
Delivery head : 85 m
For STP treated water Lifting from sump to Gardening
Each Pump capacity : 4.2 LPS
No of Pumps : 1 working + 1 working
Delivery head : 60 m
For STP treated water Lifting from sump to HVAC mackup tank
Each Pump capacity : 5.6 LPS
No of Pumps : 1 working + 1 working
Delivery head : 65 m
For UG sump water Lifting from sump to HVAC mackup tank
Each Pump capacity : 5.6 LPS
No of Pumps : 1 working + 1 working
Delivery head : 45 m
Supply, Installation, delivery, testing, commissioning of De-watering submersible pump made of Cast Iron Construction .Impeller shaft shall be S.S construction with mechanical seal suitable for building application. The unit shall include TEFC motor suitable for 415V,3Phase,50Hz & Insulation -Class F,IP 68 Protection and Base plates,Coupling,Nylon ropes for lifting pumps with Automatic ON/OFF Level Switch with common starter panel, each starter consists of suitable MPCB, Contactor, Overload relay, Single Phase Preventer, Push buttons, LED on indicators, all are in Weather Proof box (IP55) and necessary suitable copper cables from starter panel to pump (Appx.20Mtrs/each pump) etc. Pumps shall be IE-3 class rated. complete with necessary accessories. The panel shall have 2nos incomers with auto changeover switch. The panel shall be compatible with BMS (MODBUS RS 485 / MSTP) (For pump room)
Drain water lifting pumps for PHE PUMP Room
Each Pump capacity : 5.4LPS
No of Pumps : 1 working + 1 working
Delivery head : 25 m
Drain water lifting pumps for STP Room
Each Pump capacity : 5.4LPS
No of Pumps : 1 working + 1 working
Delivery head : 25 m
Drain water lifting pumps for service trench
Each Pump capacity : 5.4LPS
No of Pumps : 1 working + 1 working
Delivery head : 25 m
OHT & UG SUMP Transfer Pumping System
Automatic Level Control System for the OHTs and UG SUMP.
Supply, Installation, Testing, Commissioning and handing over of automatic tank level controller comprising of the following:Level Control with Motorised valves comprising of following:
Magnetic ball float type Level sensor for tank - High Level & Low level - 1 set. valve actuator, suitable for the following ball / butterfly valve. The mechanism shall be of tight shut-off type. - 1 set. butterfly / ball valve, with suitable adaptor for the above valve actutaor - 1 no. Wiring with 2C x 2.5 sqmm copper wires in 20-mm GI conduits interconnecting the level sensor and the valve actuator - Assume 50 RMT. Power transformer, if necessary for supplying power to the valve actuator from field available power supply of 230V, 1Ph., 50hz, complete with powder coated, weather proof mounting box, incoming 5A MCB, etc., complete.- 1 set.
For Domestic, Flush ,HVAC MAKEUP Water OHTs & UG SUMP:
a) With 80mm butterfly valve - Flush & HVAC mackup
b) With 100mm butterfly valve - Domestic
Supplying, installing, testing, commissioning and Handing over of approved make Rain water filteration for Pressure sand filter of MS construction with Epoxy coating complete with necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate. The filter shall also include initial charge of under bed and multi – grade filter media to suite the requirement complete. Etc. as per the detailed specification for the efficient working of system. The inside of filter should have Food grade Neoprene rubber line of 4mm thick. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete. The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 12 Cum / hr - (8hr operation time)
a. Filter Feed Pumps - Horizontal, centrifugal Pumps Self priming type complete with motor, base plate, coupling etc with wetted parts, in CI - 2 Nos. (1W+1S) complete with panel and accessories and shall have dry run protection and weather proof enclosure : 12 Cum / hr @ 25-30m head
b. Hypo Dosing system of electromechanical type pf capacity 0-4 Lph, dosing pump, storage tank of as per suitable capacity
c. Dual media Filter with a filtration rate of 12 Cum / hr, Filter media, Multiport valve and with necessary accessories
Design, engineering, and providing all equipment's, installation and commissioning of equipment's/electrical panel /piping for 160 KLD water treatment plant as description given in below: (8HRS. OPERATION)
a. Filter Feed Pumps - Horizontal, centrifugal Pumps Self priming type complete with motor, base plate, coupling etc with wetted parts, in CI - 2 Nos. (1W+1S) complete with panel and accessories and shall have dry run protection and weather proof enclosure : 20 Cum / hr @ 30-35m head
b. Hypo Dosing system of electromechanical type pf capacity 0-4 Lph, dosing pump, storage tank of as per suitable capacity
c. Supplying, installing, testing, commissioning and Handing over of approved make Pressure sand filter of MS construction with Epoxy coating complete with necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate. The filter shall also include initial charge of under bed and multi – grade filter media to suite the requirement complete. Etc. as per the detailed specification for the efficient working of system. The inside of filter should have Food grade Neoprene rubber line of 4mm thick. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 20 Cum / hr
d. Supplying, installing, testing and commissioning and handing over of approved make Activated carbon filter of MS construction with Epoxy coating and initial charge and complete with all necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate etc. The filter should comply to all technical specifications for the efficient working of the system. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 20 Cum / hr.
e. Hardness measuring Kit to measure the hardness of the treated water at the outlet of the filter with necessary connections as required
Supplying, installing, testing, commissioning and Handing over of approved make RO plant 17KLD - 5hrs operation time
FILTER FEED WATER PUMPS:
Supplying, installing, testing and commissioning of 2 Nos. of transfer pumps (one working + one stand by) for pumping the water from treated water Tank (OHT). The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts, nuts,saddle and mesh..
Suitable indoor wall mounting type control panel with auto / manual change - over switch including dry run protection arrangement, wiring upto panel, earthing etc. complete.
1 no. pressure gauge 4" dial with needle valve and tee fittings.
2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Suction side.
2 nos. of UPVC ball valve SCH 40/80 Rating suitable on delivery side.
UPVC manifold of suitable dia on Suction & delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.
Dual media filter
MICRON CARTRIDGE FILTER
Supply, installation, testing and commissioning of Micron Cartridge Filter for removal of finer suspended particles in the water. The micron cartridge filter shall be suitable for following requirements / specifications.
Maximum pressure drop across the unit - 0.5 kg / sq.cm
Silt Density Index (SDI) -- less than 5
Micron cartridge filter shall be provided with pressure guage with needle valve 2 nos. (1 on the inlet and 1 on the out let)
HIGH PRESSURE PUMP
Supplying, installing, testing and commissioning of 1 no. vertical type Monobloc in - line High pressure pumps for pumping the water to RO membrane assembly. The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with SS manifold.
MOC - CI / SS 304
The rate quoted shall be inclusive of:
1 no. pressure gauge 4" dial with needle valve and tee fittings.
1 no. of ball valve of brass body nickel plated with stainless steel ball, lever operated (RB/TBS / Cimbrio make) and tested to 20 kg / sq.cm.on Suction side.
1 no. of ball valve of brass body nickel plated with stainless steel ball, lever operated (RB/TBS / Cimbrio make) and tested to 20 kg / sq.cm.on Delivery side.
SS manifold of suitable dia on delivery side with flanged end on either sides and collar provision for connectivity of above mentioned valves.
RO MEMBRANE & PRESSURE VESSEL
Supplying, installing and commissioning of the RO membrane assembly unit with necessary manifold, supporting system, clamps, brackets, interconnecting piping, valves, pressure guages etc., with backish water membrane (filmtec / Hydranautics make) for removal of TDS in the tanker / metro / borewell water. The RO membrane assembly shall be as per the following requirement and specification (However the actual requirement of membrane as per the system design / demand shall be verified by the vendor with respect to "ROSA" Analysis)
Type of Membrane: Brackish
Size of membrane:
No. of pressure vessel / tube - 1 Element
No. of elements in one vessel / tube
Total qty of membrane
Type of pressure vessel / tube - PVC Pipe ( 6 kg - 10 kg/ sq.cm)
RO SKID
Supplying, installing, testing and commissioning of SS 304 SKID with required supports and accessories of Reverse Osmosis Unit. The SS 304 skid should enclose the following:
RO membranes of Total no of Membranes mentioned above
SS 304 Pipe lines for Complete High Pressure lines
UPVC Pipe lines for Complete Low Pressure lines
Two numbers of 4" Dial Glycerin filled Pr.Gauge at RO Feed & RO Reject line of 21 kg/cm2 Pr.rating.
One number of Flowmeter / Rotometer at RO Feed, RO Reject & RO product line
Low pr.switch & High pr.switch at Inlet and outlet
One number of Brine control valve, By pass valve, Chemical cleaning valve at inlet and outlet, required bolts and nuts etc.,
ULTRAVIOLET STERILIZER
Supply, installation, testing and commissioning of the ultraviolet sterilizer suitable for flow rate. The unit shall be suitable for removing the bacteria in RO Permeate water.
The unit shall comply with the following technical specifications.
The quartz sleeve protection for UV lamp.
Unit shall be suitable for a working pressure of 5 sq.cm
Mounting brackets to be provided.
Suitable for 220V single phase power supply operation.
Stainless steel type 304 electropolished purification chamber.
Single port providing visual indication of lamp.
High instensity UV lamps rated for min of 7500 hours continuous use
MEMBRANE CLEANING SOLUTION TANK
Supply erecting, testing and commissioning of circular double layered HDPE Chemical Cleaning Tank of capacity as mentioned below.Tank with Top Lid.
Storage tank of capacity 200 litres
RO MEMBRANE CLEANING SYSTEM PUMP
Supply, installing, testing and commissioning of 1 No. of Monobloc type RO membrane cleaning system pumps (One working) for pumping the primary treated water through Micron cartridge filter, high pressure pump.The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with mani fold.
MOC - SS 316 (Complete parts in SS 316)
The rate quoted shall be inclusive of:
1 no. pressure gauge 4" dial with needle valve and tee fittings.
1 no. of UPVC ball valve SCH 40/80 Rating suitable on Suction side.
1 no. of UPVC ball valve SCH 40/80 Rating suitable on delivery side.
Alarm indication with signal in the event of pump failure etc.
UPVC manifold of suitable dia on delivery side and suction side for connectivity of above mentioned valves.
MCC PANEL
Supply, fabrication, erection, testing and commissioning of control panel (CP). The panel shall be of "non comparmentalised" for RO Feed Pump, High Pressure Pump & Dosing Pumps. The Panel shall be sheet steel fabricated, finished with powder coating of approved color, and of floor mounted, free standing cubicle type with incoming MCC TP and N bus bars and outgoing with fuse switch units, starter relays, over load,he panel shall have Voltmeter, Ammeter and indicating lamps on the incoming side only indicating lamps for the pumps on outgoing side to indicate the operation mode. The panel shall be complete in all respectsand prior to the supply, fabrication drawing shall be submitted for consultants approval.
The rate quoted shall be inclusive of the following:
Earthing for panels .
Dry run protection arrangement for the following :
RO Feed Pump
High Pressure pump
Dosing pump
Chemical cleaning pump
Audio/visual alarm indication in the event of malfuntioning of RO Plant
RO STORAGE TANK
Supply erectioning, testing and commissioning of circular / rectangular / Square double layered SS Tank of capacity as mentioned below. Open Top Lid.
Storage tank of capacity 9000 litres (Half day storage)
Design, engineering, and providing all equipment's, installation and commissioning of equipment's / electrical panel /piping for 240 KLD MBR Sewage treatment plant as description given in below:
1. Pump capacity / head may vary and bidder to provide as per their design. Should be substantiated during detailed engineering
2. Provision of pump sets can change as per bidders design and hydraulics
3. Necessary lifting arrangement should be provided for submersible pumps and submersible Mixers.
Supply, installation, testing and commissioning of following electro mechanical works and equipments -
S.S. 316 Manual coarse bar screen in screen chamber for peak flow- 10 mm opening with suitable lifting arrangements complete as required.(1 no.)
S.S. 316 Manual fine bar screen in screen chamber for peak flow- 6 mm opening with suitable lifting arrangements complete as required. (1 no.)
Providing & fixing of MSEP slotted pipe oil skimmer of suitable capacity .Slotted pipe type with necessary arrangements in Oil & Grease Trap. (1 No.)
Equalised Sewage Transfer pumps of 2Nos. (1W +1S) of duty, vertical submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, alongwith lifting arrangement etc. From Equalisation Tank to Fine screen prior to Anoxic tank (Cutter type Pumps) Solid handling capacity shall be 20 mm.
Equalised Sewage Bypass pumps of 2 Nos. (1W +1S) of duty, vertical submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. alongwith lifting arrangement etc. From Equalisation Tank to nearest sewer drain during festive season only (Cutter type Pumps) Solid handling capacity shall be 20 mm.
Twin lobe type rotary air blowers for Equalisation Tank & Sludge Holding Tank with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor suitable for 415 + 10% volts, 3 phase, 50 cycles A/C supply, coarse bubble air grid, complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 2 nos (1W+1S)
Common Air blowers shall be used to supply compressed air in Equalisation tank and Sludge Holding tank.
Coarse bubble air grid for Equalisation tank and Sludge Holding tank ,MOC- UPVC (1 Lot)
Drum Screen prior to Anoxic Tank - 2 mm Punched Hole MOC : Body CS Drum : SS 304
Providing Submersible Mixers and its associated accessories and lifting arrangements etc. all complete in all respect. For Anoxic Tank. MOC : SS 304
Twin lobe type rotary air blowers (VFD Driven) for Aeration Tank As per design (Approximately 100-120 Nm3/hr) with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, supply of fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 3 Nos.
Non clog type retrievable air diffuser system tubular type capable of handling desired flow of air. Air diffuser grid shall be assembled in modular form so that they can be replaced/ repaired easily from platform at the top. Air diffuser system shall be provided with fine air bubble type diffusers for Aeration tank as per Bidders design. MOC- EPDM
Air flow rate per diffuser- 8 m3/hr per diffuser. (1 Lot.)
Nitrifying liquor transfer pumps of 2nos. (1W +1S) of duty of suitable capacity Min. 24 m3/hr and 12 m head , horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring mix liquor from MBR tank to Anoxic tank.
Providing MBR modules (for 22 hrs operation) submerged type housed in cabinet with membrane add on provision, to handle sewage of 240 KLD flow transmitter, turbidity analyser, automatic cleaning and recovery systems for the membrane, of Immersed hollow fiber, ultra filtration membrane with SS skid for housing the membranes alongwith Membrane Module Lifting Arrangements. Maximum Flux Permitted : 25 LMH
Membrane MOC : PVDF Braket MOC : SS
Membrane Lifting Arrangements : Monorail and electric hoist with electric travelling trolley of suitable capacity equivalent to 1.5 times the load of equipment to be lifted
Providing twin lobe type rotary air blowers (VFD Driven) for MBR Tank As per design with suitable capacity with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, supply of fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required.
SPECS FOR ACOUTIC HOOD - For Air Blowers supplying air to Equalisation Tank & Sludge Holding Tank, Aeration Tank and MBR Tank -Supplying acoustical hood for each blowers in STP. Hood shall be made out of 16G GI sheet with 50mm thick open cell nitrile rubber of density 140-180 kg/cum. Care shall be taken for heat dissipation of motor while enclosed on hood. Openings in hood for piping shall be acoustically closed with fibre glass and silicon sealant etc. all complete in all respect as directed by manufacturer and site in charge.
MBR Permeate pumps (VFD Driven) - 2Nos. (1W +1S) of duty horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. From MBR Tank to MBR Permeate tank and Irrigation tank (For Blending)
Backpulse pumps (VFD Driven) - 2Nos. (1W +1S) of Suitable capacity - As per Membrane Manufacturer's deign - horizontal centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. for Membrane Cleaning
Hypochlorite Dosing System for Disinfection of Treated Sewage and CTBD Effluent
NaOCl dosing Pumps MOC: PP - 2 Nos. (1W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity. (1 Set)
Hypochlorite Dosing System for CIP of Membrane System
NaOCl dosing Pumps MOC: PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity. (1 Set)
Citric Acid Dosing system along with agitator for CIP of Membrane System
NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity with Agitator MOC- SS 304. (1 Set)
Centrifuges shall produce a dewatered sludge cake of no less than 20% dewatered solids. At least 95- 98% of the solids shall be captured in the dewatered cake and less than 2% of the solids shall be in the centrate.
Dewatering Polyelectrolyte (DWPE) Dosing System
For Poly dosing 2 nos. Dosing pump MOC : PP - (1W+1S) with 1 No. HDPE Tank of suitable capacity with SS Mixer
Dosage : 1.5-2.5 kg / ton of dry solids @ 0.1% solution strength
PIPING
Providing and fixing all piping (as described below) and isolation control Ball / butterfly valves (Min. PN 10) of required sizes and numbers with all accessories, fittings, supports, clamps, double flanged flexicon rubber expansion joint with rubber gasket as per system pressure, nuts, bolts, washers, fasteners, puddle flanges for all tanks, other flanges, all required type of valves such as NRV's, flow control valves, sampling valves, flow measurement device, butterfly valves, ball valves, globe valves etc., SS 304 screen strainers Y type at suction of clear water pumps, for making the system complete in all respects with anti corrosive protection. Details are as follows:
Butterfly Valve : Cast Iron Wafer type butterfly valves (PN 10) as per IS:13095, with SS disc, SS shaft, SS seating rings, SS internal fastening, EPDM seat, CS external nuts-bolts.
Check Valve: Cast Iron body dual plate wafer type check valve (NRV) (PN 10) with SS disc, SS stem, EPDM seat, spring & pin, SS stem, SS internal fastening, CS external fastening.
PVC Flexible Breaded Hose Pipe: Submerged piping for raw sewage transfer pumps / Submerged piping for diffusers.
Interconnecting pipes with required pipe fittings, control valves, manual valves as per the system design, flange connections, gaskets,GI fasteners, pipe supports etc for making the system completed.
MSEP : All interconnecting piping & Frontal Piping for filters
CI for Pump suction and discharge
UF System : UPVC
RO High pressure piping - SS 316 with Victaulic coupling
Low pressure piping - uPVC
GI (Class 'C') : Air grid piping-non submerged & UPVC for submerged Piping
INSTRUMENTS
Capacitance type Level Transmitters in Equalisation Tank, MBR Tank, MBR Permeate Tank, CTBD effluent collection Tank, UF Feed Tank, UF Permeate Tank/RO Feed Tank, RO permeate Tank, RO reject tank with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.
Level switches in Sludge Holding Tank, Plant Room Sump, Centrate collection Sump, all Dosing Tanks with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.
DO meter in Aeration tanks
Electro- magnetic Flow transmitter with indicator and totalizer
‒ At the discharge of Equalized sewage transfer Pumps
‒ At the discharge of Equalized sewage Bypass Pumps
‒ At the discharge of MBR Permeate Pumps
‒ At the discharge of MBR Backpulse Pumps
‒ Any location wherever necessary as per bidder’s design
Pressure Transmitter at the discharge Backpulse Pumps
DPS across bag filter, Cartridge Filter, RO system
Pressure switch at the suction & Discharge of RO High Pressure Pump
Turbidity meter on the discharge pipe of MBR Permeate Pumps and UF permeate pumps
Flow Transmitter on RO Reject Line
pH Transmitter at discharge of RO Inlet and RO Permeate Line
Conductivity Transmitter at RO Inlet and Permeate Line
ORP analyser with transmitter and controller
Dump valve & Auto valve for RO system
Pressure gauges
If required, Instrument air compressor with an air receiver tank, air filter-dryer and air filter regulator along with instrument air piping and tubing for pneumatically operated valves
PLC PANEL
Providing Complete instrumentation system including PLC for Automatic Operation. Vendor Should provide PLC Logic as required to operate their System. PLC controller with SCADA software system should be integrated with BMS through Open protocol including all necessary accessories, material ,tools takcles required to complete the job in all respects alongwith UPS. BMS compatible with any open communication protocol for 3rd party integration.
PLUMBING RELATED ELECTRICAL WORKS
Supply, installation, testing and commissioning of following electro mechanical works and equipments -
ELECTRICAL INSTALLATION FOR SEWAGE TREATMENT PLANT SYSTEM
LT Panel for Sewage Treatment Plant
Design, Engineering, Manufacture, Supply, Commissioning, Documentation of LT Switchgears for STP area as per the scope of work including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of wiring material, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing, and calibration of relays and metres etc., including all labour and materials, as per approved drawings, specification of this tender and directions of PMC/Employer The panel incommer shall not exceed the 400A of MCCB & 25 numbers of outgoing including spare feeder.
Supply, Installation testing & commissioning of local push button with all necessary accessories including all labour and materials required for STP system as per approved drawings, specification of this tender and directions of PMC/Employer
LT Power & Control Cable
Supply, laying,testing and commissioning of power,control & communication cables along with cable tray and supports of required size for STP System as per the scope of work.
Earthing System
Supply, installation and connection of required size of earthing strip required for STP area as per the scope of work including welding at joints, providing anti-corrosive paint or bitumen for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials,as per specification of this tender and directions of PMC/Employer (Earthing will be Pipe earthing with 3000mm depth &40 mm Dia pipe, Strip size will be decide as per the fault level calculation.)
Supply and laying of 1000mm wide safety insulation mats of 415V,required for HVAC system grades required for maintenance of electrical equipment in substation, including cutting to required shape as per IS
ADDITIONAL ITEMS /OTHER WORKS / SYSTEM
Any other items, works, systems not specifically mentioned above but necessary for satisfactory performance of the system
Miscellaneous Items
Sewage parameter:
Inlet:
TSS (mg/l/) = 150
BOD (mg/l/) = 600
Total nitrogen (mg/l/) = 50
Oil & grease (mg/l/) = 10
Total coliform = 10000
Outlet:
TSS (mg/l/) = <20
BOD (mg/l/) = <10
COD (mg/l/) = <50
Total nitrogen (mg/l/) = <10
Oil & grease (mg/l/) = Nil
Total coliform = 100
SOIL WASTE MANAGEMENT
Supply, Installation, testing and commissioning Composting machine OWC - 130 (SS)
Supply, Installation, testing and commissioning Composting Curing system - 200kgs/day
Supply, Installation, testing and commissioning Composting Curing system - 100kgs/day
Supply, Installation, testing and commissioning Garden shredder - 5HP
Supply, Installation, testing and commissioning Bone shredder - 2HP
INTELLIGENT FIRE ALARM SYSTEM
DVC (Digital Voice Command) system for fire fighters telephone. Supplying, installing, testing and commissioning of Digital Voice Command Extended Memory and Keypad. The DVC Should support 2 ways Communication for Fire Fighters.The Fire Fighters Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers. This has to be installed in one of the above 10 loop fire alarm panel. This inclusive of necessasy accessories, amplifiers (suitable for fire fighters telephone quantity mentioned in this BOQ), modules & should be seamless integration with all fire alarm panels. This should be the same make of main fire alarm panel. Vendor shall consider the suitable size cabinet of fire alarm panel to accomodate this DVC equipments
Supplying, installation, testing and commissioning of Central Graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required
Supplying, installation, testing and commissioning of Addressable Active Repeater Panel consists of display board having 160 Character Display with Touch key pad, Mother board which will have 64 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking.
Supplying, installation, testing and commissioning of Intelligent / Analog Addressable Detectors - Multi Sensor - Heat Cum Smoke Detector with mounting Base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with mounting base complete as required, with Back box, Glands
Supplying, installation, testing and commissioning of Response indicator for all detectors located above false ceiling / Below False Floor complete with all connections etc as required with Back box, Glands
Supplying, installation, testing and commissioning of Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications as required with Back box, Glands
Supplying, installation, testing and commissioning of fixed type Intelligent Addressable Heat Detector / Thermal Detector with base with Binary coded address setting / Rotary Switches / Electronic codec programable address setting. Dual LED’s for 360° visibility complete with base as required Back Box, Glands
Supplying, installation, testing and commissioning of addressable Fire Control Module / Control Relay Module for AHU / CSU / HRW / TFA Tripping, Access Control Door Tripping, Smoke Exhaust Fan activation, Fire Damper Activation / PA System Activation etc complete as required with back Box, Glands
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing and commissioning of Intelligent Addressable Beam Detector (5-50mtrs) with Binary coded address setting Dual LED’s for 360° visibility comprising of 4 wire system with Infra-Red Emiter and Receiver in a single housing and single reflector platecomplete with emitter and received including connections with remote test features etc complete as required with back box, Glands. The rate shall inclusive of Response Indicator. Also the rate shall inclusive of External dedicated 24VDC Power Supply Unit with Battery backup in case the Beam Detector shall not have loop pwered. Power Supply Unit shall be provided with necessary Enclosures.
Supplying, installation, testing and commissioning of Intelligent Addressable Manual Pull Station Dual Action type, complete as required with back Box, Glands.
Supplying, installation, testing and commissioning of addressable horn cum strobe complete as required with Back Box, Glands
Supplying, installation, testing and commissioning of fire fighter telephone handset complete as required Back Box, Glands
Supplying, installation, testing and commissioning of intelligent interface Gateway Module Unit Modbus / BACNet Protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required.
Supplying, installation, testing and commissioning of fire fighter telephone jack complete as required.
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/Employer.
Supply, installation, fixing, testing and commissioning of Analogue Addressable Monitor module with back box (1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided withSPDT contact with required fixing accessories
Supply and installation of MS Powder coated Trunking 300 x 50 mm x 1.6mm with cover & fixing suppports etc as required (Cable dressing for Fire & PA panel)
Supply and installation, testing and commissioning of Power Supply : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON, Battery Fail, Battery Charging, battery back up etc. (inclusive of Battery ckt & shall have inbuilt charger circuit, 2x12V 7.1AH Battery and enclosure)
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Fire Alarm System OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the Fire Alarm System OEM do not have an objection. No deviation shall be accepeted.
WATER LEAK DETECTION SYSTEM
Supplying, installation, testing and commissioning of Water Leak Detection sensing cables with end of line connectors along with Hold-down clips at every 0.3M interval.
Supplying, installation, testing and commissioning of Addressable Water leak detection panel including battery backup (12 hr) as per the below specification inclusive of all necessary accessories - Inbuilt with Modbus for BMS integration - Relay output for Alarm and fault - 230V AC 5A - LED Indications (power ON, Alarm, fault etc) - 100 event log - Wall mount type with enclosure and PSU with battery backup
Supplying, installation, testing and commissioning of Water Leak Detection Module Water leak tape interface module with display, enclosure, PSU with battery backup and alarm out for Hooter, relay out for fire integration as per specification
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the PMC/Employer
RODENT REPELLENT SYSTEM
Supplying, installation, testing and commissioning of Master Console panel including support bracket (12 Transducer per console) with modbus for BMS integration
Supplying, installation, testing and commissioning of 1 pair flexible 14/40 SWG Specially coated wire, PVC sheathed Cable
Supplying and fixing of following sizes of M.S steel conduit along with accessories in surface / recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required 25 mm
PUBLIC ADDRESS SYSTEM
Supply , Installation, Testing & Commissioning of ceiling loudspeaker of 6 W, 100 V line speaker with fire rated dome having the following specifications : - Power: 9W or better, - Rated Power: 6Watts or better, - Power Tapping: 6/3/1.5W or better - Effective frequency range (-10 dB): 57 Hz to 24KHz - SPL at rated power (6W at 1 m) 94dB or better, With other neccessary accessories to make system complete as per specification/drawings Note: The rate shall inclusive of back box for True Ceiling Speaker wherever applicable. The Quantification of the True Ceiling Speaker shall be quantified as per the tender drawing.
Supply , Installation, Testing & Commissioning of wall mount loudspeaker of 6 W, 100 V line speaker having the following specifications : - Max Power: 9W or better, - Rated Power:15Watts or better, -Power Tapping: 15/7.5/3.75/1.9 W -Effective frequency range(-10 dB): 95 Hz to 20 kHz -SPL at rated power (10W at 1 m) 99/87 dB (SPL)r, With other neccessary accessories to make system complete as per specification/drawings Note: The rate shall inclusive weather proof cabinet for Outdoor wall mount 6W Speaker. The Quantification of the True Weather Proof Speaker shall be quantified as per the tender drawing.
Supply , Installation, Testing & Commissioning of Wall mount 15W full-range Speaker, with following specifications and as directed by PMC/Employer. - Woofer: 4” & Tweeter: 1” or better - Housed in a fire rated ABS plastic metallic grille - Maximum SPL 94.3dB or better, - Sensitivity 82.5dB or better, - Operating Temperature of -25ºC ~ +55ºC - Transformer with 8 Ohm pass- through. - Transformer taps: 100V: 15 W, 7.5 W, 3.75 W & 1.8 W, 8Ohm. - Frequency response (-10 dB) 83Hz - 23 kHz. - Coverage Angle(1Khz) Horizontal 180° Vertical 186° or better - IP-65 as per IEC268-5 WIth other neccessary accessories to make system complete as per specification/drawings
Supply, installation, testing & commissioning of Master 12 Zone Digital Voice Alarm Network Controller & be able to handle up to 2000 Watt load. •A single system controller shall be able to manage up to 20 routers, 16 call stations and up to 492 loudspeaker circuits.•The system controller shall be an EN54-16 compliant and certified device in a 2 RU, 19”-cabinet. The TCP/IP capable network device shall contain all controlling and monitoring functions of a voice evacuation system. An additional network card enables Dante network audio transport between the different system controllers. Digital Voice Alarm Network Controller should be able to comply with the following requirement a. Pre-recorded messages (up to 255). b. 2000 W RMS power unit and control of 12 Speaker Zones. c. 2 eruo audio inputs & 2 Rca audio input (line)Control inputs and control outputs for connection to external systems d. Supervision of the amplifier, the speaker lines, the emergency microphone, the pre-recorded messages, e. Possibility of redundant connection with routers and microphone desks, up to 1000 m All are digital PA System. Analog system shall not be accepted. The rate shall inclusive of all necessary accessories line communication cables from Controller to Amplifier, Amplifier to Microphone Console etc.
Supply, installation, testing & commissioning of 1 x 500 W Power Amplifier @ 4/8Ω 70/100V, Class D shall have following features & shall comply to technical specifications 1. Protected against overload, short circuits and over-heating 2. Built-in fan with temperature-controlled rotation speed control, with airflow from front to back of device.
Supply, installation, testing & commissioning of 4 x 250 W Power Amplifier @ 4/8Ω 70/100V, Class D shall have following features & shall comply to technical specifications. 1. Protected against overload, short circuits and over-heating 2. Built-in fan with temperature-controlled rotation speed control, with airflow from front to back of device.
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port with audio management software The system software shall converts multi audio input to SIP extension broadcasting and RTP Muliticast. It can manage and control various PA System professionally. Efficient manageable audio system. Support RTP Multicast. Support SIP extensions. Support built-in bell ringing. Multi zones management. Multi kinds of audio streams. Flexible schedule configuration. Compatible with all windows music players. Provide all-in-one unified IP audio solutions. Manage and control various PA System excellently. Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Public Address System OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified
Supplying, installation, testing and commissioning Rack Mounted Multimedia Player as per specifications
Supply and laying of 2 Core - 1.5 sq.mm Armoured Speaker Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the PMC/Employer.
ACCESS CONTROL SYSTEM
Reader Controller: Supply, Installation, Testing and Commssioining of 2 reader controller, power supply unit, TCP IP connectivity with tamper detection provision as per the tender specifications.Cost shall inclusive of enclosure and power supply unit for controller/EM locks (power supply unit shall inclusive of battery backup 8 hrs). Controller Should Support global Antipass back.
Supply, installation, testing & commissioning of Multi-Technology contactless smart card reader, Mullion mount, IP65, Converge multiple credential technologies onto one reader platform with support for Smart and Mobile credentials, Bluetooth, OSDP, encrypted communication between credential and reader, supports Secure Identity Object on Seos, iClass SE/SR, Mifare DESFire EV2/Ev3 and Mifare Classic , Certification: UL 294/cUL, FCC certification CE including RoHS II,BIS, EAL 5+ certified secure with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories.UL Certified.
Supply, installation, testing and commissioning of 8K contactless smart card support 13.56 Mhz, support multi-layered trusted management of secure identities using the portable Secure Identity Object data model, supports AES 128 bit cryptographic algorithm for data protection, printable cards with corporate 1000 programming to avoid duplication.with Lanyard to hold the cards as per specification. (The card reader is capable of rewriting type)
Supply, installation, testing and commissioning of Access Control System Server: Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection.(Web Based Enterprise level Application for Access Control security Management software for Access Control & Alarm Monitoring and Software with Access control platform and door licence) Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted
Supply, installation, testing and commissioning of Client workstation (Access Control System Client Workstation) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" FULL HD LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port (Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the Access Control System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if theAccess Control System Software OEM do not have an objection. No deviation shall be accepeted.)
Supplying, installation, testing and commissioning of Single Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for single door as per the tender specifications
Supplying, installation, testing and commissioning of Double Leaf EM Lock 600LBS in each Leaf Electromagnetic Lock with required mounting brackets for double door as per the tender specifications
Supplying, installation, testing and commissioning of surface / flush mounted Magnetic Contact (Door position sensor) for access controlled doors as per the tender specifications
Supplying, installation, testing and commissioning of Local scare alarm with required wiring between LSA & door contacts (For fire exit doors). Rate shall inclusive of door contacts
Supplying, installation, testing and commissioning of panic bar for fire exit doors (single leaf) as per Specification (For fire exit doors, Panic BAR shall be RED in color).
Supplying, installation, testing and commissioning of 4 core 1.0 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories for connecting controller to Lock & door position sensors, Buzzer, BGU, Pushbutton as per the tender specifications
Supplying, installation, testing and commissioning of 2 core x 1 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories
Supplying, installation, testing and commissioning of Buzzer for access controlled doors as specified in the Tender Specifications
Supplying, installation, testing and commissioning of EDR (Emergency Door Release)
Supplying, installation, testing and commissioning of MS Powder coated Trunking 300 x 50 mm x 2mm with cover & fixing suppports etc as required for panel dressing
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.
Supplying, installation, testing and commissioning of X-Ray Single Generator Indoor Bagage Scanner with following technical parameters. Tunnel Size: Min 600 mm (W) x 400 mm (H) or Better, Dimensions: Length: Min 2000 mm or Better, Height: Max 1300 mm or Better. Single view of 160KV high energy XBS which provides steel penetration of 34mm Steel block and wire resolution of 38-AWG. 2 built-in Full HD cameras which helps to monitor the Tunnel Entry & Exit. Software with Inbuilt Artificial Intelligence tool that has 24 types of items to display the Scanned images with AI overlay. Single Screen that displays both Scanned images and video surveillance of Fisheye camera simultaneously. Complete with 0.5 meter Discharge SS Tables with dedicated computer for Monitoring, Image storage and archiving with necessary software. Along With Dual Core Processor at min 3.6 GHz, 8GB RAM, 4TB Harddisk, With Wired Mouse & Customised Keyboard with Emergency stop function, Linux OS and CMS to be incorporated for Centralised monitoring at the premises. Min 1 million images storage along with video recording of Full HD camera, Threat image protection (TIP) enabled in the software with 100 knives, 100 explosives, 100 guns to be loaded in the TIP library which enables the operator to active during security check. HIT, MISS & FALSE Alarm features must be included with different colour code as Green for HIT, Red for MISS and Yellow for FALSE alarm to be enabled in the software. Daily reports to be generated for TIP along with date, time, screener particulars and number of bags screened. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010
Supplying, installation, testing and commissioning of Door frame metal detector (DFMD) with Dual side detection, 18 overlapping detector Multi-zones, Displaying panel, Indication of alarm areas, Adjustable area of sensitivity, Two Way operation, Static counting (Directional Counter - In, Out, Net and Alarm), Battery backup 6 to 8 hours. Shall be compatible to integrate with Barriers. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010
Supplying, installation, testing and commissioning of High Speed Swing Barrier of (4+1) lane configuration, flaps made of transparent acrylic with 10 mm thickness, RGB indication, Clear passageway, Indoor, opening / closing time of 0.2 seconds minimum. The housing and the base columns shall be made of SS304 with semigloss smooth finish. The barrier shall be equipped with Servo motor and controlled in both directions. In the event of a power failure, both directions shall be freely accessed, Automatic reset upon resumption of power supply. The dimensions shall be Max of 100mm width or better, Max of 1400mm length or better, min 600mm height or Better and the passage width of ~600mm for Normal lane & ~900mm for wide lane. It shall be above 5 million cycles with provisions to mount Smart Card Reder & QR Card Reader, power supply module, wiring & necessary components. It shall Compatible for Integration with Access control & CCTV system. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010
Supply, Installation, Testing and Commissioning of Boom Barrier of 6 meter wide with power supply and necessary manual control components. Barrier should operate with 24V Servo motor not less than 5 million cycles. Shall be suitable to control through access control system & Compatible for Integration with CCTV System, Perimeter security system. Barrier arm with LED light and Red reflective strips and to provide accessories such as Wireless remote, Push button, Loop detector, Dual eye Photocell, light with buzzer and boom resting post. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010
IP CCTV SURVEILLANCE SYSTEM
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Dome camera; 1/2.8" CMOS or better; 5MP (2592x1944) resolution, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3.2 ~ 10 mm (3X) motorized varifocal; IR viewable length: 30m (98.42ft); DC auto iris,; Day & Night (ICR), WDR (120dB); BLC, WDR, SSDR; H.265, H.264, MJPEG, Minimum 3Nos. individually configurable simultaneous streams in H.265 @ 2592 x 1944 & 30 Fps or better supported;Audion in and out Micro SD/SDHC/SDXC IP66, IK10. Other technical detail shall be satisfied / complied as per the technical specifications.
Supply, Installation, Testing and Commissioning of 5MP resolution Varifocal lens IR Bullet camera; 1/2.8" CMOS or better; 5MP (2592x1944) resolution, 30fps; Color : 0.07Lux (F1.3, 1/30sec), B/W : 0Lux (IR LED On); 3.2 ~ 10 mm (3X) motorized varifocal; IR viewable length: 30m (98.42ft); DC auto iris,; Day & Night (ICR), WDR (120dB); BLC, WDR, SSDR; H.265, H.264, MJPEG, Minimum 3Nos. individually configurable simultaneous streams in H.265 @ 2592 x 1944 & 30 Fps or better supported;Audion in and out. Micro SD/SDHC/SDXC IP66, IK10. Other technical detail shall be satisfied / complied as per the technical specifications.
Supply, Installation, Testing and Commissioning of 5MP IR PTZ Camera with built-in Wiper, Image Sensor:1/2.8" Progressive Scan CMOS, Min. Illumination: Color: 0.1Lux, BW: 0Lux (IR LED On), 30fps, Image Compression H.264 / H.265 / MJPEG or better, White Balance, Noise Reduction: 2D/3D DNR, Blur Detection: Yes, Shutter Speed: 2 - 1/12,000 sec or better, Day & Night: True Day/Night with ICR, Optical Zoom: 30X, Digital Zoom: 12X. Focus Mode: Auto / Manual, Focal Length: 5-150 mm IR Distance: 200 Meter or better built-in wiper, Optimized IR with adjustable intensity, and angle IR or better depending on the zoom ratio, Working Temperature: -30°C ~ +55°C Protection Level: IP66 rated. The PTZ Camera shall be powered by POE also the cost shall inclusive of POE injector for required power to energies the PTZ Camera. Other technical detail shall be complied as per the technical specifications.
Supply, Installation, Testing and Commissioning of ANPR Camera - 2MP IR Bullet Camera, 6~60mm (10x) Zoom, Color: 0.03 Lux (F1.6, 1/30 sec, 30IRE), 0 Lux (IR LED on), Max. 120 fps (H.265/H.264), Min. 3 individually confrigurable stream in H.265 at 2MP & 120fps, Maximum IR viewable length 90mtr, Day & Night (ICR), extremeWDR (150 dB), DIS with built-in Gyro sensor, Analytics events based on AI engine (NPU) : Object detection (Person/Face/Vehicle - car, truck, bus, bicycle, motorcycle/License plate), IVA (Virtual line/Area, Enter/Exit, Loitering, Direction, Intrusion), Analytics events : Defocus detection, Motion detection, Tampering, Fog detection, Audio detection, Sound classification, Shock detection, Appear/Disappear, IP67, NEMA4X, IK10, PoE, CE, FCC, BIS, UL.
Supply, installation, testing and commissioning of ANPR Camera Software
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" 4K / UHD LED MONITOR LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port. (For ANPR Camera) Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.
Supplying, installation, testing and commissioning of IP Based Ultrakey Lite Control keyboard with function key,Roller joystick, LED display, Dedicated Programmable keys for Operations
Supply, installation, testing & commissioning of Main / Primary Recording Server required for 400 cameras or Higher, VMS embedded Server, recording - Live/playback via Workstation, Max. each server support Recording bandwidth min 700Mbps for min 128 CH in each Server, Intel Xeon Processor, 4 x 16GB ECC memory, min 24 Bay 3.5” HDD, system must have N+1 Fail-Over, Auto backup from SD card,Normal, Schedule (Continuous / Event), Event (Pre / Post),, Event Action- Instant Viewer, Preset, Alarm Out, Pop-up for (Smoke, Fire) , Sound and E-mail notification RAID 5, NAS with 128TB TB Storage Windows 10 IoT Enterprise, CE, & BIS. a. 45 days storage retention with 720P Resolution, 2mbps bandwidth of each camera encoding, 25 Frames per second, H.265 Compression for 400 Cameras. b. All required storage devices with minimum of 8TB Surveillance Internal Hard Drive HDD-3.5 Inch SATA 6Gb/s 256MB Cache + Drive Health Management & 3-Year Recovery Service, speed of 7200rpm or better Surveillance Hard Disk Drive in each HDD Bay shall be included. However, total Camera storage calculation shall be generated from CCTV Camera OEM Software and the same shall be considered.
Supply, installation, testing and commissioning of Client workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center client application, 1TB SATA Hard disk with 7200rpm, GbE network interface card, DVD-RW standard keyboard & Mouse with Dual NVIDIA® GeForce® RTX 2080 video card with 21" 4K / UHD LED MONITOR LED MONITOR. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 video, 1 Microphone jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port. Note: The Configuration mentioned is only Minimum requirement. Vendor shall be consider as per the CCTV Camera OEM & Video Managment System Software OEM recommendations, in case of higher configurations shall be required to enable the functional requirements and consider the cost for the same & quote accordingly. Bidder shall be considered the specified configuration if the CCTV Camera OEM & Video Managment System Software do not have an objection. No deviation shall be accepeted.
Supply, Installation, Testing & Commissioning of Main Viewing Screens with wall mount 6 x 55" 4K UHD LED Screens, with HDMI/VGA outputs, PC inputs. Screens should have 2 ms or better response time, Energy Star compliant & capable to operate for 24x7 operation. It shall come with remote control and shall have various picture mode options for data representation with all necessary fixing accessiories for viewing. Note: The display shall be mounted 3 x 2 matrix and all four screen to be considered as single display screen / monitor. One input from Server / Client / CCTV Client PC shall be interfaced with Monitor Station. All necessary display controller, Encoder, Decoder, Splitter and Display configuration software etc., shall be considered to complete the successful installation of Video Display. Bidders shall be considered the necessary additional equipment cost in this line item. No additional cost shall be provided if will require to comply the above requirement.
Supply, installation, testing and commissioning of 3 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 3000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.
Supply, installation, testing and commissioning of 6 Metre Length Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length Integral junction chamber flush with the pole for termination of CAT-6A and power cables. Including Bakelite sheet. Provided with a camera mounting plate - fixed to the pole with provision of holes for camera mounting - holes dimensions to be provided by you. PU coated through 5 tank cleaning process and with 2 coats of primer and 2 coats of PU paint and topcoat for extra weather protection. Poles are fine finished. The rate shall inclusive of all the necessary camera mounting accessories, back boxes, Termination Junction Boxes for power supply (if required), 4 Nos of Anchor bolt shall be 25mm dia and 500mm length, 2 Nos of 32mm GI pipe medium class collar bend for cable entry at the bottom of the foundation etc., to be considered. The Pole Cost shall be inclusive of all required RCC foundations as mentioned the foundation details of 450mm (L) x 450mm (W) x 1000mm (H) RCC M25 Grade. The Pole cost shall inclusive of excavation, shuttering, foundations and backfilling the soil etc. no extra cost shall be provided to Civil contractor.
DATA NETWORKING & TELECOM SYSTEM (ICT)
Supply, installation, testing and commissioning of Core Switch shall have minimum 48 x 1/10 SFP, 4*1/10G SFP Ports. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.
Supply, installation, testing and commissioning of 1G SFP Transceiver Module for Uplink for Segment / Distribution POE switch
Supply, installation, testing and commissioning of 10G SFP Transceiver Module for Uplink / Downlink for Core switch
48 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Layer 3 managable Edge Switch shall have minimum 48 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (48Port * 30W = 1440) 1440 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.
Supply, Installation, testing and Commissioning of Layer 2 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports- Min 1GBPS - 2 Nos SFP Fiber Ports with Modules loaded & Include all required components for multiple switch stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning.. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of Layer 2 Managed POE Switch- 8 ports of 10/100/1000 MBPS or more with 2 SFP Ports- Min 1GBPS - 2 Nos SFP Fiber Ports with Modules loaded & Include all required components for multiple switch stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Wi-Fi Manager / Controller: Supply, installation, testing and commissioning of Centralized management Wi-Fi Manager / Controller Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.
Wi-Fi Access Points: Supply, installation, testing and commissioning of Wi-Fi Access Points Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.
Supply, installation, Testing and Commissioning of Firewall and the key features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. a. Major supported features: b. Anti-Virus c. Intrusion Prevention System (IPS) d. Web filtering e. E-mail filtering, including protection against spam and grayware f. Data Leak Prevention (DLP) g. Application Control h. Traffic inspection i. Content inspection and filtering j. Security Profiles components k. Security Profiles/lists/sensors l. Logging and reporting
Supply, installation, Testing and Commissioning of Enterprises Network Management System (EMS) and the same shall be subcription shall be considered for 36 months from the handing over the project. The Key Features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. To ensure that ICT systems are delivered at the performance level envisaged, it is important that an effective monitoring and management system be put in place. It is thus proposed that a proven Enterprise Management System (EMS) is proposed by the bidder for efficient management of the system, reporting, SLA monitoring and resolution of issues. Various key components of the EMS to be implemented as part of this engagement are a. Network Monitoring System b. Server Monitoring System c. Helpdesk System d. The solution should provide a unified web-based console which allows role-based access to the users.
Supply, installation, Testing and Commissioning of Network Managment System Server with the following configuration for Enterprises Network Management System for Building Operations: Netowrk Management Server machine: Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted
Supply, laying, termination of both end (Field & Rack end) and Testing of Cat 6A U/FTP Cable, 4 pair, 23 AWG & UL listed and ETL tested. Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.
Supply, Installation, Testing & Commissioning of 4 Pair Un-armoured 0.5mm Cable - Telephone
Supply, Installation, Testing & Commissioning CAT 6A Modular 24 Port Patch Panel fully loaded
Supply, Installation, Testing & Commissioning of Tool-less Cat 6A UTP Information Outlet with shutter or integrated dustcover
Supply, Installation, Testing & Commissioning of RJ 11 Information Outlet with shutter or integrated dustcover
Supply, Installation, Testing & Commissioning of Single / Dual Face plate for Field side, the rate shall inclusive of Flush Box - 3 Module to mount the face plate in surface, conseal, ceiling etc.
Supply, Installation, Testing & Commissioning of Cat 6A - RJ 45 IDC plug / CCA connector UL listed and ETL tested for CCTV - Camera Side
Supply, Installation, Testing & Commissioning of CAT 6A UTP 1 mtr Patch Cord
Supply, Installation, Testing & Commissioning of CAT 6A UTP 2 mtr Patch Cord
Supply, laying, termination of both end (Field & Rack end) and Testing of 12 Core OM4 Multi Mode fiber, Outdoor ECCS Armoured Unitube - LSZH outer sheath, 1500N Tensile Strength, 2000N Crush Resistance and OD 9mm. Bidder shall refer the details of technical requirement in Technical Specifications document. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.
Supply, Installation, Testing & Commissioning of 1U Sliding Fibre panel (LIU) rack-mount 24-Fiber with splice holder, cable spool and loaded with LC Adapter and LC OM4 Pigtail at Each HUB Room
Supply, Installation, Testing & Commissioning of LC/LC Single Mode / Multi mode Patch Cord 2mtr
Supply and Installation of 19", 42U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.
Supply and Installation of 19", 32U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.
Supply and Installation of 19", 12U Rack, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.
Supply and Installation of 19", Rack 9U, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.
Supply, Installation, Testing & Commissioning of Server Gateway like Architecture VoIP Based IP PBX, with Industry Standard CPU based on IP at core with support for hot redundant configuration. IP PBX System Machine should be inbuilt 256 Analog and 100 IP Extensions and it can be expandable upto 896 Analog & 400 IP Extensions, 8 Trunk line + 30 SIP Trunk + 8 Digital Extension. Note: Software shall be installed in Access Control System Servers and Client licenses to be installed in Access Control System Workstation.
Supply, Installation, Testing & Commissioning of 24 Key Digital phone - Operator phone.
Supply, Installation, Testing & Commissioning of Basic IP Phone: Display Size: 2.8 Inch, 320x240 Color Display Gigabit Ethernet Port
Supply, Installation, Testing & Commissioning of Caller ID Telephone with Speaker
Supply, Installation, Testing & Commissioning of 10 Pair Un-armoured 0.5mm Cable - Telephone
Supply, Installation, Testing & Commissioning of 20 Pair Un-armoured 0.5mm Cable - Telephone
Supply, Installation, Testing & Commissioning of 50 Pair Un-armoured 0.5mm Cable - Telephone
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.
Supplying and Laying of following Size DWC HDPE pipe ISI Marked along with all accessories like socket, bend, coupler etc., confirming to IS 14930 Part II complete with fitting, cutting and joining etc., direct in ground (750mm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 63mm dia (OD-63mm & ID-51mm Nominal) Note: OD - Outer Diameter & ID - Inner Diameter
Supply, Installation, Testing & Commissioning of 10 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.
Supply, Installation, Testing & Commissioning of 20 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.
Supply, Installation, Testing & Commissioning of 50 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.
Supply, Installation, Testing & Commissioning of 500 (250 + 250) pair Master MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.
INTEGRATED BUILDING MANAGEMENT SYSTEM
INTEGRATED BUILDING MANAGEMENT SYSTEM SERVER SITC of 4th Gen Intel Xeon Scalable (1.9 GHZ / 6-CORE / 15MB / 85W) Processor, 8DIMM Slots 2Nos. of 8GB DDR4 RAM, with NVIDIA Graphics Card, 8 LFF (3.5 inch) Hot Plug SAS/SATA Open Bay 4 Nos.of HP 2TB 6G SATA 7.2K 3.5IN MDL SC HDD SAS/SAT H240 Smart HBA with encryption key external DVD R/W 1 x 800W/900W Gold HT PLG PWR Ethernet 1GB 2-Port 36I Adapter with 2GB NAND, Standard Keyboard & Mouse + Microsoft Windows Server Latest Edition, Standard with Anti-virus and MS SQL Server License, The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, ModBus, TCP/IP, LonWorks etc. through IP Protocol (Not in MSTP protocol) System should be scalable. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations required as per System requirements to fulfil the complete functionality of the system and Bidder to consider the cost for the same & quote accordingly. No Additional Cost shall be paid for Redundancy Server. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted.
BMS SOFTWARE: SITC of the following window based graphical software for IBMS system with 1 No. Client for Operator workstation. The Software shall have 3D & HD vector dynamic graphics with Autocad import of plan with Zoom In & Zoom Out facility, Native 64 Bit System, Multi-Monitor Support-( Max 4 Nos), Multi-language support, BTL, UL, EN Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing, dot net platform, Certified OPC DA Server by OPC Foundation, Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP. Cybersecurity audit trail, 4-eye principle, Seamless integration of certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, Use of network infrastructure that supports physical network or VLAN segmentation, Placing the web server in a “demilitarized zone” (DMZ), End-to-end encryption, from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups. The Software shall be considered for 5000 IO Points and cablaple of connecting minimum of 5 Client License. The Sofftware should support Eenrgy Billing software for the Tenant Billing with required customisation as per the client requirement. Special Note - The Software should have cloud connectivty and can be access remotively using User Name and Password from anywhere. For further compliance vendor to follow the Tender specifications.
SITC of Software Additional IO Points for Soft and Hard IO's of any combination - for 10000 IO's
SITC of BTU billing software capable of generating necessary report / billing format for direct billing to the tenants. Provision for Customisation of Software as per customer. Third party software shall be accepted for BTU Billing activities. However the same software shall be proven technology in India Market and the OEM of BTU Meter Billing Software must submit the completion certificate and healthy certificate of the Software functional from Multi-User Tenant Corporate Customer.
Client version BMS software for "Monitor & Control" application, complete with Advance Graphics for Realtime Graphical Depiction of the Statuses and Controls as per the Detailed IO Summary .
SMS & E-mail alarm notification module with unlimited user capability,SMS Paging & Email Facility for transmitting specified alarms to designated personnel.
GPRS / GSM Modem of 4G / 5G Modem
Internet Router Which can support upto 100 MBPS Speed
SITC of A 3 size Laserjet olour Printer suitable for the application, with driver software.
SITC of Client Workstation for BMS Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center Client Application, 1TB SATA Hard Disk Drive with 7200rpm, GbE Network Interface Card, DVD-RW Standard Keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 Video Card with 32 " 4K UHD LED Monitor. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2 Optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 Video, 1 Microphone Jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.
SITC of Client Workstation for CCTV ( at HUB ROOM ) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 500 GB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center Client Application, 500GB SATA Hard Disk Drive with 7200rpm, GbE Network Interface Card, DVD-RW Standard Keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 Video Card with 32 " 4K UHD LED Monitor. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2 Optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 Video, 1 Microphone Jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.
SITC of Client Workstation for ACS ( At Security Gate ) Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 500 GB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center Client Application, 500GB SATA Hard Disk Drive with 7200rpm, GbE Network Interface Card, DVD-RW Standard Keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 Video Card with 32 " 4K UHD LED Monitor. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2 Optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 Video, 1 Microphone Jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.
IP DDC CONTROLLERS WITH NATIVE BACNet / IP CONFIGURABLE: SITC of DDC Controllers, Standalone and Networkable 32 Bit DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable IP 55 enclosure for indoor mounted type and for all outdoor type controllers it shall be IP66 complete with all wiring and accessories. DDC Controller must have a inbuilt IoT enabled communication protocol to connect and configuring directly with Cloud BMS Server. Bidder shall Quote Accordingly. Gateway controllers shall not be accepted. The IO Count shall be referred from the IO Data Summary
The controller shall have inbuilt 2-port Ethernet switch. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The DDC shall have IT security including HTTPS and BACnet Secure Connect communication, Operating voltage AC 24 V / DC 24V . The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Each DDC shall have WLAN interface for local operation, engineering and commissioning. It should have one integration port inbuilt and port for POT for local interface. For further compliance vendor to follow the Tender specifications . Automation stations / DDC Controller with I/O module etc., The controllers shall be NATIVE BACNET IP based. The controller shall be with 32 bit microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The controller should have minimum of 24 onboard IO Points in case of Compact Controller and Modular controller as per the IO counts necessary modules to be included with inbuilt Port for RS485 communication. The DDC's shall store programs and program parameters in non volatile memory. The DDCs shall be housed within a suitable powder coated MS enclosure complete with all protection, terminals, wiring and accessories as mentioned.
DDC - 1 to DDC - 10 ( Main building - GF to 9F ) - HRW and Floor Panel - Left Wing
DDC- 11 to DDC - 20 ( Main building - GF to 9F ) - HRW and Floor Panel - Right Wing
DDC- 21 to DDC - 22 ( Main building - GF to 9F ) - Damper Control - Right Wing
DDC- 23 ( Main building-Terrace Floor ) - Left Wing - FAN's
DDC- 24 ( Main building-Terrace Floor ) - Right Wing - FAN's
DDC- 25 ( Main MV Panel ) - Utility Building
DDC- 26 ( Chiller and Pump Feeders ) Utility building
DDC- 27 ( CT and CDW Pumps ) Utility building
DDC- 28 ( TRANSFORMER PANEL ) Utilty Building
DDC- 29 ( DG ROOM Panel ) - Utility Building
DDC- 30 ( IBMS and UTILITY PANEL ) - Utility Building
DDC- 31 ( Fire Pump Room ) - Utility Building
DDC- 32 - EV CHARGING PANEL - Main Building
DDC- 33 & 34 ( Floor Panel ) - Main Building
Electrical Multifunction Meters through Modbus over RS485 protocol ) - 525 nos ( Each Meter 15 Points )
Chiler Plant Manager through Modbus over RS485 protocol - 1 Set ( Total CPm 500 Points )
Lift Integration through Modbus over RS485 protocol - 16 nos ( 20 points per lift )
UPS Integartion through Modbus over RS485 protocol - 5 nos ( 25 points per lift )
Fire Alam System Integartion through Modbus over RS485 protocol - 2 Panel ( 1500 points / Panel )
Thermostat / EC Fan Integartion through Modbus over RS485 protocol - 360 nos ( 5 points per device )
BTU meter Integartion through Modbus over RS485 protocol - 500 ( 5 points per Meter )
Access Controller Integartion through Modbus over RS485 protocol - 22 nos ( 10 points per system ) - To be connected in nearest DDC
Temperature Sensors - Duct Type - Indoor. SITC of Temperature Sensors - Duct Type - Indoor. shall be of the Resistance Temperature detector Ni 1000 type. These shall be two wire type . It shall be with rigid stem and of averaging type. These shall be suitable for duct installation. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.
Temperature Sensors - Immersion type - Chilled Water - Indoor SITC of Temperature Sensors - Immersion type - Chilled Water - Indoor shall be of the Resistance Temperature detector Ni 1000 type. These shall be two wire type. It shall be provided with separate SS thermowell. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C. The rate shall inclusive of SS Thermowell. No additional cost shall be provided for Thermowell.
Pressure Transmitter - Water Type SITC of Pressure Transmitter to mount across the Supply / Return headers to monitor the Pressure in both Inlet & outlet at the CHW water near Main building The Sensor Range should be 0- 10 Bar and accuracy shall be ± 2%.
Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). SITC of Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). shall be provided with a sun shield. Sensors shall be of capacitance type with an effective sensing range of 0% to 95 % RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Sensors shall be provided with a housing. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C.
Co2 Sensors - Wall Mount type - Outdoor (For Ambient Co2 Level Measuring). SITC of Ambient type CO2 Sensor. Carbon Dioxide Transmitter should be wall mounted with 0 – 2000 PPM Range. These shall work on 24V AC/DC supply with +/- 10% variation the output being standard type i.e. 4-20 mA / 0 - 10 Volts etc with an accuracy of +/- 2%
Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display SITC of Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C.
Duct Static Pressure Sensor (For AHU static pressure monitoring). SITC of Duct Static Pressure Sensor (For AHU static pressure monitoring). Range shall be 0-500 Pa, Accuracy at ±1% FS, It shall be IP54 rated. Vertically mounted with pressure connections pointing downwards.
Differential Pressure Switch for Fan Status (Indoor type) SITC of Differential Pressure Switch for Fan Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct
Differential Pressure Switch - Filter Status (Indoor type) SITC of Differential Pressure Switch - Filter Status (Indoor type) shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit
Water Level Sensor SITC of Water Level Sensor to monitor the Tank / Sump level interms of Volume and the Level Sensor shall be suitable for Sump / OH Tank of liquid and the Output shall be 0-10V / 4-20 ma
Hydrogen Sensor: SITC of Wall Mount type - Indoor shal be flame proof type. Accuracy shall be +/- 10% FSD of H2%. Response time shall be less than 3 seconds
CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) SITC of CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) 24V AC/DC supply with the output being standard type i.e. 4-20 mA / 0- 10 Volts etc. Response time of the detector shall be <10 minutes. Range of the sensor shall be 0 to 2000 PPM
Water Leak Detaection System SITC of WLD System with 4 zone Control panel necessary power supply with 4 nos of 5 mtrs Ribbon Cable for WLD with suitable Modbus Rs 485 Communication
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable unarmoured Shielded ATC FRLS cable.
Supplying, laying, termination, testing and commissioning of signal cables. 3 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable unarmoured Shielded ATC FRLS cable.
Supplying, laying, termination, testing and commissioning of signal cables. 4 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable unarmoured Shielded ATC FRLS cable.
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.5 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.
Supplying, laying, termination, testing and commissioning of signal cables. 3 Core x 1.5 Sqmm, PVC insulated, copper conductor cable Un-Armoured / Flexible FRLS cable.
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 20mm PVC Conduit.
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing of perforated Hot dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc.as required. 100 mm width x 50 mm depth x 1.6 mm thickness
Supply and providing of PVC cable truf complete with all fittings and accessories 100mm (W) x 75mm (D)
SITC of Managable Network Switch : 24 port layer Network switch with 10/100/1000 Mpbs with 24-Port Gigabit Smart Managed Switch with 4 Gigabit RJ45/SFP COMBO ports
SITC of 24U Rack - 19" type Equipment racks for mounting the Servers/ Switches in the BMS Equipment Room, & for mounting field mounted Switches at every Floor. Racks shall be complete with Modular Patch Panels for Patching the Field Cables ( Cu and FO) with the Edge Switches on floor as required. Racks shall be provided with Dual Power A&B, and should have 2 PDU Strips, Redundant Fans and Door to have Tamper Switch.
SITC of 4 pair Armoured OFC Cable in suitable GI Conduit from Network Switch to Switch connectivity
SITC of OFC Cable Slicing with nceessary termination kit with OFC to Cat6e Convertor
SITC of Cat 6 e Cable in suitable PVC Conduit from IP connectivity from DDC Controller to Network Switch
230 V Realy with 2 NO NC for status monitoring
Media Convertor from RS 232 / 485 / Ethernet for Integration
Any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies,fiber converters, LIUs, Specific System cables etc. to complete the installation. Contractor to mention the quantity of the below items with cost apart from the below item if any other acceroiers are required , controator to add the same Patch Panels,1mtrs Cat6 Patch Cords LIU’s Pigtail cables 1mtr LC to LC Single Mode Patch Cords,Labels,any Other component to complete the design intent
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.52 MB
VolumeIPQC.pdf
Tender Documents • 1.97 MB
VolumeIIConditionsofContract.pdf
Tender Documents • 2.69 MB
VOL5AArchitecturalDrawings.pdf
Tender Documents • 36.90 MB
VOL5CHVACFIREDrawings.pdf
Tender Documents • 30.36 MB
VOL5DMEPELVDrawings1.pdf
Tender Documents • 29.60 MB
VOL5EPHEDrawings.pdf
Additional Documents • 35.35 MB
VOL5BSTRUCTUREELECTRICALDrawings.pdf
Tender Documents • 37.43 MB
VolumeIIITechnicalSpec.pdf
Tender Documents • 22.30 MB
BOQ_771804.xls
BOQ • 1.86 MB
Download all tender documents and submit your bid