Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.8 LAdmitted-Finance NEHRANWALI DHANI TEHSIL RAHWATSHAR DISTRICT HANUMANGARH RAJASTHAN | GANGANAGAR | RAJASTHAN | 335062 | +5.00% | ₹4.8 L | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹5.1 L
EMD Value
₹10,280
Closing Date
16 Feb 2026, 5:00 pmClosed
SE CIVIL RVPN KOTA
NEW CIRCLE BUILDING SAKATPURA KOTA
RNM of Control room building at 132KV GSS RIICO Dholpur
2026_RRVPN_535314_1
NIT28SEIVILKOTA202526
Open Tender
Civil Works
132 KV GSS RIICO Dholpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
AO TNC RRVPNL Hindaun
₹10,280
Yes
10 Mar 2026
5 Feb 2026
17 Feb 2026
5 Feb 2026
16 Feb 2026
5 Feb 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: SE Civil RVPNL Kota
Name of Work: R&M of control room building at 132kv GSS RIICO Dholpur
Contract No: RVPN/SE/CIVIL/KOTA/NIT No.28 (2025-26)
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description(PWD Integrated BSR 2022 Rajasthan ) Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) (B-13.1) BI01010001010000000000000515BI0100001113 sqm Excess(+) Full Conversion INR
2 B-12/12.46.2:- Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work BI01010001010000000000000515BI0100001114 sqm Excess(+) Full Conversion INR
3 B-13/13.24:- Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. BI01010001010000000000000515BI0100001115 sqm Excess(+) Full Conversion INR
4 B-10/10.22:-Providing batta (gola) 75mm x 75mm in cement concrete (1 : 2 : 4) including finishing with cement mortar 1 : 3 as per standard design. BI01010001010000000000000515BI0100001116 Rm Excess(+) Full Conversion INR
5 B-8/8.13.2.1:-Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :30 mm thick . Commercial veneer both side BI01010001010000000000000515BI0100001117 Sqm Excess(+) Full Conversion INR
6 Providing and fixing Nigeria / Ghana/Ivory Coast teak wood grade-I moulding and beadings in doors and windows size 25x12mm (B-8.23.3) BI01010001010000000000000515BI0100001118 Mtr Excess(+) Full Conversion INR
7 B-14.43.1:-Dismantling G.I. pipes (external work) including excavation & refilling trenches after taking out the pipes & including stacking of pipes within 50m lead:15 to 40mm nominial bore BI01010001010000000000000515BI0100001119 Mtr Excess(+) Full Conversion INR
8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 15 mm niminal bore(S-2.37.1) BI01010001010000000000000515BI0100001120 Mtr Excess(+) Full Conversion INR
9 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.25 mm niminal bore(S-2.2.3) BI01010001010000000000000515BI0100001121 Mtr Excess(+) Full Conversion INR
10 S-2/2.7.4:- P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. brass long body 15mm nominal bore weight not less than 690 gm BI01010001010000000000000515BI0100001122 each Excess(+) Full Conversion INR
11 S-2/2.11.1:- P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete : Brass wt.300 gm,15mm BI01010001010000000000000515BI0100001123 each Excess(+) Full Conversion INR
12 S-3/3.16.3:-P & F rigid PVC pipe (IS: 4985 mark ) class II/( 4 Kg./Sq. cm.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia BI01010001010000000000000515BI0100001124 Mtr. Excess(+) Full Conversion INR
13 S-3.17.9 (a) P&F rigid PVC pipe fittings (IS 4985 mark of approved quality /make including jointing the pipe with Cement rubber ring and lubricant 75 mm dia Bend (87.5 degree) BI01010001010000000000000515BI0100001125 each Excess(+) Full Conversion INR
14 S-2/2.15.1-P & F Full way valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. BI01010001010000000000000515BI0100001126 each Excess(+) Full Conversion INR
15 S-2/2.15.3-P & F Full way valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 25mm nominal bore. BI01010001010000000000000515BI0100001127 each Excess(+) Full Conversion INR
16 (S-2.26.3)P & F PVC storage tank ( IS :12701 marked indicating the BIS license No.) of approved make with cover, 25mm dia 1mtr. Long G.I. Over flow pipe & 25cm.long wash out pipe with plug & socket, including making connection etc. complete of approved design: 500 liters capacity BI01010001010000000000000515BI0100001128 Each Excess(+) Full Conversion INR
17 (B-12.37.2(b) Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding old work ( one or more coats ) over and including scraping and priming coat with Cement primer. Same colour BI01010001010000000000000515BI0100001129 Sqm Excess(+) Full Conversion INR
18 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8nominal Mix .B-3.1.6 BI01010001010000000000000515BI0100001130 Cum Excess(+) Full Conversion INR
19 Providing & laying Chequered plain cement concrete embossed specially manufactured non slipping tiles of approved make 20mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete. (B-11.16.3) BI01010001010000000000000515BI0100001131 sqm Excess(+) Full Conversion INR
20 B-14.23.1:-Dismantling of tile work in floors & roofs laid in CM incl.stacking of serviciable material& disposal of unserviceable material within 50 m lead for c.conc flooring Thickness of tiles 10mm to 25mm BI01010001010000000000000515BI0100001132 sqm Excess(+) Full Conversion INR
21 (B-12.43.2):-Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including sand papering, prime coat, making smooth surface with cement based putty etc complete in all respect: . old Work BI01010001010000000000000515BI0100001133 sqm Excess(+) Full Conversion INR
22 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm B/7.18.2 BI01010001010000000000000515BI0100001134 sqm Excess(+) Full Conversion INR
23 (B-1.2)Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil BI01010001010000000000000515BI0100001135 Cum Excess(+) Full Conversion INR
24 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).B/7.12 BI01010001010000000000000515BI0100001136 SQM Excess(+) Full Conversion INR
25 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).B/7.13 BI01010001010000000000000515BI0100001137 SQM Excess(+) Full Conversion INR
26 Renewing glass panes with wooden fillets wherever necessary : 4mm thick plain glass panes.(B-13.5.1) BI01010001010000000000000515BI0100001138 sqm Excess(+) Full Conversion INR
27 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. (B-14.7.3) BI01010001010000000000000515BI0100001139 Cum Excess(+) Full Conversion INR
28 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm thick nominal size aggregate.(B-11.3.1) BI01010001010000000000000515BI0100001140 sqm Excess(+) Full Conversion INR
29 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).(B-6.1.6) BI01010001010000000000000515BI0100001141 cum Excess(+) Full Conversion INR
30 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick.(B-12.3.2) BI01010001010000000000000515BI0100001142 sqm Excess(+) Full Conversion INR
31 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: B-9.2 BI01010001010000000000000515BI0100001167 kg Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: SE Civil RVPNLKota
Name of Work: R&M of control room building at 132kv GSS RIICO Dholpur
Contract No: RVPN/SE/CIVIL/KOTA/NIT No.28 (2025-26)
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description (PWD Electrical BSR 2022 Jaipur) Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR:Short point (up to 3 mtr.) (E-1.1.1) BI01010001010000000000000515BI0100001113 5 P.Point 359 Excess(+) Full Conversion INR
2 Medium point (up to 6 mtr.) (E-1.1.2) BI01010001010000000000000515BI0100001114 4 P.Point 578 Excess(+) Full Conversion INR
3 Long point (up to 10 mtr.) (E-1.1.3) BI01010001010000000000000515BI0100001115 1 P.Point 772 Excess(+) Full Conversion INR
4 P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .:(E-7.1) BI01010001010000000000000515BI0100001116 5 each 23 Excess(+) Full Conversion INR
5 P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .:(E-7.2) BI01010001010000000000000515BI0100001117 5 each 50 Excess(+) Full Conversion INR
6 Providing & Fixing of of 3/5 pin 6 amp. flush type non modular socket made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(E-7.10) BI01010001010000000000000515BI0100001118 4 each 33 Excess(+) Full Conversion INR
7 Providing & Fixing of 3/6 pin 16 amp flush type non modular socket made out from Industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(E-7.11) BI01010001010000000000000515BI0100001119 4 each 78 Excess(+) Full Conversion INR
8 Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .(E-17.2.2) BI01010001010000000000000515BI0100001120 8 each 270 Excess(+) Full Conversion INR
9 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm (E-4.1.7) BI01010001010000000000000515BI0100001121 30 Mtr. 81 Excess(+) Full Conversion INR
10 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . LED Street Light fixture with Minimum lumen output 3700 lm (E-18.12.2) BI01010001010000000000000515BI0100001122 3 each 3370 Excess(+) Full Conversion INR
11 E-17/17.4.1.1 Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. RECESSED MOUNTED Minimum lumen output 3000 lm BI01010001010000000000000515BI0100001123 4 each 2288 Excess(+) Full Conversion INR
12 Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Minimum lumen output 3000 lm Post top Luminarie (E-18.10.2) BI01010001010000000000000515BI0100001131 5 each 5703 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.22 MB
BIDRIICO28.pdf
Tender Documents • 1.42 MB
FinalContractagreement.pdf
Other Document • 2.05 MB
Amendmentcontractagreement.pdf
Other Document • 0.38 MB
circularofunbalacedbid.pdf
Other Document • 0.07 MB
BOQ_953689.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid