Tender Value
₹63.5 L
EMD Value
₹1.3 L
Closing Date
23 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
PLANNING
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnoverof V/N or 'V' whichever is less; where V= Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet.
Tenderer shall have a valid Electrical Contractor's License issued in thename of the firm by any State Government and shall furnish/attach allthe particulars of the Electrical license along with their offer.
(a)The Tenderer must have successfully completed or substantiallycompleted any one of the following categories of work(s) during last 07(seven) years, ending last day of month previous to the one in whichtender is invited: (i)Three similar works costing not less than the amountequal to 30% of advertised value of the tender, or (ii)Two similar workscosting not less than the amount equal to 40% of advertised value of thetender, or (iii)One similar work costing not less than the amount equal to@10<37@ of advertised value of the tender. (b)(i) In case of tender forcomposite works (e.g. works involving more than one distinctcomponent, such as Civil Engineering works, S&T works, Electrical works,OHE works etc. and in the case of major bridges - substructure,superstructure etc.), tenderer must have successfully completed orsubstantially completed any one of the following categories of work(s)during last 07 (seven) years, ending last day of month previous to theone in which tender is invited: (i)Three similar works costing not lessthan the amount equal to 30% of advertised value of each component oftender, or (iii)Two similar works costing not less than the amount equalto 40% of advertised value of each component of tender, or (iv)Onesimilar work costing not less than the amount equal to 60% of advertisedvalue of each component of tender. Note :- Work experience certificatefrom private individual shall not be considered. However, in addition towork experience certificate issued by any Govt. Organization, workexperience certificate issue by Public listed company having averageannual turnover of Rs. 500 crore and above in last 3 financial yearsexcluding the current financial year, listed on National Stock Exchange orBombay Stock Exchange, incorporated /registered at least 5 years priorto the date of closing of tender, shall also be considered provided thework experience certificate has been issued by a person authorized bythe Public listed company to issue such certificates. In case tenderersubmits work experience certificate issued by public listed company, thetenderer shall also submit along with work experience certificate, therelevant copy of work order, bill of quantities, bill wise details of paymentreceived duly certified by Chartered Accountant, TDS certificates for allpayments received and copy of final/last bill paid by company in supportof above work experience certificate.
Definition of similar nature of work:- For this tender the following workonly will be considered similar work for judging the technical eligibilitycriteria. "Supply, Installation, testing and commissioning of Electrical works/General services works having a part of SITC of High Volume Low Speed (HVLS) fans with all accessories. OR Any of the OEM or Authorized Dealer of OEM for HVLS fans"
24 conditions · 3 needing a document upload
If firm ( Partnership Firm, Registered Society & Registered Trust)is required to submit Power of attorney it should be submitted asper given proforma enclosed in tender document.
if firm (Company registered under Companies Act 2013) isrequired to submit a copy of Authorization/Power of Attorneyissued by the Company (backed by the resolution of Board ofDirectors) in favour of the individual to sign the tender on behalfof the company and create liability against the company itshould be submitted as per given proforma enclosed in tenderdocument.
If firm LLP (Limited Liability Partnership) is required to submit acopy of Power of Attorney/Authorization issued by the LLP infavour of the individual to sign the tender on behalf of the LLPand create liability against the LLP, it should be submitted as pergiven proforma enclosed in tender document
1.0 The tenderer should indicate clearly replies against itemincluded in this check list. 2.0 Furnished the details of credentialAlongwith attested copies of supporting document. 3.0 Quotedthe accessories and essential spares. 4.0 Furnished your ITCC(income Tax clearance Certificates. 5.0 Quoted period ofcompletion correctly. 6.0 Kept your offer valid for 60 days. 7.0Visited the site and have studied the methodology To beadopted for completion of the work. 8.0 Submitted theintegration scheme. 9.0 Submitted the BAR CHART /PERTCHART. 10.0 Submitted scheme of completion of work. 11.0Submitted details of staff working under tenderer. 12. Submitthe bid security certificate in appropriate form
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of High Volume Low Speed (HVLS) fans & illuminated signage boards at Ayodhya dham station building & Lucknow station building over Lucknow Division.
1220-SrDEE-NR-LKO~NR
1220-SrDEE-NR-LKO
Open
Works - General
6 Months
Lucknow, Uttar Pradesh
₹0
₹1.3 L
1 Sept 2026
1 Sept 2026
9 Sept 2026
35 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 63,53,677.08 | ||
| — | 1500.00 | — | — | ||
| Supply & fixing of PVC conduit pipe conforming to IS 9537 part-III/1983(latest version) on surface with accessories , junction box,bends etc. including fixing,clamping etc. As per technical scope of work. Size-25 mm dia (Medium) | — | — | — | 49,350 | |
| — | 70.00 | — | — | ||
| Supply of Batten/Angle Holder conforming to IS : 1258-2005 or ceiling rose, 3 plate conforming to IS : 371-1999 & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and as per technical scope of work. | — | — | — | 1,176.7 | |
| — | 2500.00 | — | — | ||
| Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (Latest Version) , and drawing in Laid (recessed /surface) M.S / PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning. As per technical scope of work. Size-1.5 sq mm | — | — | — | 38,075 | |
| — | 3000.00 | — | — | ||
| Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (Latest Version) , and drawing in Laid (recessed /surface) M.S / PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning. As per technical scope of work.Size-2.5 sq mm | — | — | — | 68,700 | |
| — | 2500.00 | — | — | ||
| Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (Latest Version) , and drawing in Laid (recessed /surface) M.S / PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning. As per technical scope of work.Size-4.0 sq mm | — | — | — | 80,625 | |
| — | 12.00 | — | — | ||
| Earthing with 40 mm dia GI pipe class 'B' 3 meter long earth electrode as per IS:3043 (latest version) to achieve earth resistance less than 5 Ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. inner size 400mm x 400mm) on top, provision of earth plate. As per technical scope of work. | — | — | — | 24,752.76 | |
| — | 600.00 | — | — | ||
| Supply, laying, connection & commissioning of 8 SWG GI wire & drawing in laid/on surface MS/PVC conduit pipe,confirming to relevant IS Buried in ground/recessing in floor from earth electrode to earth terminal of equipment's. Including supply of material. As per technical scope of work. | — | — | — | 8,412 | |
| — | 150.00 | — | — | ||
| Supply, laying, connection & commissioning of G.I. strip 40 x 5 mm (Galvanized) confirming to relevant IS , fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement. As per technical scope of work. | — | — | — | 12,369 | |
| — | 6.00 | — | — | ||
| Supply, erection, fixing, testing and commissioning of CRCA sheet- 8 way, SPN MCB distribution board, IP 54,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. a) DP MCB 25-32 A,10 KA "C" curve (incoming)-1 No, b)25A DP RCCB = 01 No. having a sensitivity current 30 ma c) 6- 32A ,10 KA MCB SP "C" curve = 04 Nos.(Outgoing). Make of MCB/RCCB & DB: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per technical scope of work. | — | — | — | 38,929.98 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall mounted/ recessed LT double door 2-way,IP54, distribution board made up of steel sheet, Phosphatized powder painted complete with neutral link, earth paint, din rail and prewired with DP RCBO's 25 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2 & IEC-61009-1 or latest. Make of RCBO & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per technical scope of work. | — | — | — | 16,173.3 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall mounted/ recessed LT double door 2-way,IP54, distribution board made up of steel sheet, Phosphatized powder painted complete with neutral link, earth paint, din rail and prewired with DP RCBO's 40 (2P, 30 mA) Amp outgoing confirming to IS: 12640-2 & IEC-61009-1 or latest. Make of RCBO & DBs: Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager. As per technical scope of work. | — | — | — | 23,597.36 | |
| — | 2.00 | — | — | ||
| Design, Manufacture, supply, erection, testing & commissioning of front Operated Double door type weather proof feeder pillar suitable for IP-65 degree of protection with Digital measuring instrument & Aluminium bus-bar arrangement, conforming to IS/IEC 61439 -1 & 2,Edition 3, 2020 with latest amendments. Comprising with the following MCCB's fixed in it. a) Incoming 63A Microprocessor MCCB 4P 36 KA= 01 No. b) Outgoing 40A 4P RCCB = 01 No. c) Outgoing 6-32A MCB DP "C"series = 06 Nos. As per drawing approved by Railways and Technical Scope of Work. Make of MCCB's :- Schneider Electric, ABB, GE, Siemens, L&T, Legrand, Hager conforming to IS/IEC 60947-2 or latest. The LT panel manufacturer should be CPRI-approved . | — | — | — | 98,475.78 | |
| — | 6.00 | — | — | ||
| Design, Manufacture, supply, erection, testing & commissioning of High Volume Low Speed (HVLS) gearless, direct drive Permanent Magnet Synchronous Motor (PMSM) ceiling mounted fan of diameter 7.3 metres (24 feet), complete with safety guy wire / safety retainer link, vibration isolation pads, DC motor , touchscreen HMI, and integrated VFD control suitable for operation on 230V AC single phase 50Hz or 415V AC three phase 50Hz supply. The system shall also provide a suitable interface port for connection with SCADA system for remote operation. sound level at 100% speed shall be less than 45 dB,coverage area of minimum 16,900 sq.ft., supplied with universal mounting arrangement, hardware mounting kit, and all other accessories including necessary wiring and cabling upto control panel, complete in all respects as per RDSO Specification No IS/RDSO- PSE/1002:2023 ,Date 20.01.2023 or latest , For HVLS fan. As per Technical Scope of work. | — | — | — | 19,71,186.72 | |
| — | 8.00 | — | — | ||
| Design, Manufacture, supply, erection, testing & commissioning of High Volume Low Speed (HVLS) gearless, direct drive Permanent Magnet Synchronous Motor (PMSM) ceiling mounted fan of diameter 4.9 metres (16 feet), complete with safety guy wire / safety retainer link, vibration isolation pads, DC motor , touchscreen HMI, and integrated VFD control suitable for operation on 230V AC single phase 50Hz or 415V AC three phase 50Hz supply. The system shall also provide a suitable interface port for connection with SCADA system for remote operation. sound level at 100% speed shall be less than 45 dB,coverage area of minimum 10,000 sq.ft., supplied with universal mounting arrangement, hardware mounting kit, and all other accessories including necessary wiring and cabling upto control panel, complete in all respects as per RDSO Specification No IS/RDSO- PSE/1002:2023 ,Date 20.01.2023 or latest , For HVLS fan. As per Technical Scope of work | — | — | — | 22,83,598.08 | |
| — | 460.00 | — | — | ||
| Design, manufacture, display, Erection and installation of wall mounted, hanging, ceiling-mounted, pole-mounted, or floor-mounted LED illuminated sign/direction boards in various shapes (Single & double sided horizontal & vertical Elliptical/Parabolic - Full Elliptical/Half Elliptical/Semi Elliptical or other types as per site requirement /Flat Single & double sided wall mounted etc.as per enclosed specification and as per site requirement (decided by engineer incharge). The display sheet shall be of unbreakable 040 grade translucent polycarbonate sheet of 2 mm to 3 mm thickness. The text / graphics matter visibility angle shall not be less than160 degree. The approved colour text and graphics shall be printed / router-cut on monomeric calendared vinyl of minimum 100 micrometer thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting, and entry of dust. The LED Board shall have uniform illumination with 6-8 W / sqft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. As per technical scope of work. | — | — | — | 12,62,143.4 | |
| — | 28.00 | — | — | ||
| Supply, erection, testing and commissioning of Cable End termination kit including glands and lugs, for energization of cable, Suitable for Cable Size 25-150 sqmm cable 2 Core. As per Technical Scope of work. | — | — | — | 5,320 | |
| — | 400.00 | — | — | ||
| Supply and fixing of of ISI Marked L.T XLPE ( Cross linked polyethylene insulated cable ) PVC Outed sheated strip with copper conductor cable rated 1100 Volt confirming to IS : 7098 Part -I-2025 or latest as per Technical Scope of Work of the following sizes : 4x16 sq mm | — | — | — | 3,70,792 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Signage Guidelines
ATTACHMENT
ACStoGCC1-12.pdf
ATTACHMENT
Signage Guidelines
ATTACHMENT
Tender_document_12201.pdf
ATTACHMENT
GCC_IndianRailways-April-2022.pdf
ATTACHMENT
RDSOSpecificationofHVLSfan_1.pdf
ATTACHMENT
GuidelinesonStandardSignagesatStationsonIndianRailwaysPart-2.pdf
ATTACHMENT
GuidelinesonStandardSignagesatStationsonIndianRailwaysPart-11_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .