E E Chandrapur Medium Project Dn No.1 Chandrapur
E E Chandrapur Medium Project Dn No.1 Chandrapur Civil Line Nagpur Road Chandrapur
Quotation for Preparation Of Supply Erection, Testing and Successfully Commissioning of Surge Protection System Comprising of Minimum 15m3 Bladder Vessel with load cell Arrangement, Three stage surge Suppression Air Valve for the Project of Dindora
2024_CEWRN_997491_1
E-Quotation No 01/2023-2024
Open Tender
Civil Works
Item Rate
8 days
Chandrapur
Please Rafer Tender Documents
3 documents required · 3 mandatory
₹0
Exempted
19 Mar 2024
6 Feb 2024
16 Feb 2024
6 Feb 2024
14 Feb 2024
6 Feb 2024
Amount
For R.M.-1
Providing, supplying, Erecting & Commissioning of 3. stage Surge Suppression Air Valve (Confirming to AWWA C 512 ) of Dia 150 mm. Pressure rating minimum 12 Bar with all cutting, welding of pipe for Tee (T) connection, Isolation Valve (Butterfly valve-confirming to API 609/BS 5155/EN593)- 150 mm dia. For maintenance purpose and necessary accessories as per the site requirement. Valve should have a simple and robust construction offering high reliability and free operation with high intake capacity It should be Non Slam surge Suppression high flow Combination 3-Stage air valve, including all lead & lifts (Location of Valves as per Surge analysis report)
Providing, supplying, Erecting & Commissioning of Surge Protection System comprising of Bladder Vessel with minimum Volume of 10 m3, Pressure rating minimum 12 Bar with shell-SA 516 Gr.70, Elliptic Cap-SA 516 Gr.70, Coating inside & Outside – Thk 110 mm along with sand blasting SA 2.5 with Buty1 Bladder in Vertical position, Vessel Connection Size 600 mm and connecting Pipe Size 400 mm dia.M.S., 400 mm Isolation Valve (Confirming to DIN 3352/BS 5163), Load cell arrangement, necessary piping, Flanges, Fasteners, complete including all lead & lifts. (Location of Bladder Vessel as per Surge analysis report)
For R.M.-2
Providing, supplying, Erecting & Commissioning of 3-Stage Surge Suppression Air Valve (Confirming to AWWA C 512 ) of Dia. 150 mm. Pressure rating minimum 12 Bar with all cutting, welding of pipe for Tee (T) connection Isolation Valve (Butterfly Valve- Confirming to API609/BS 5155/EN593)- 150mm dia. For maintenance purpose and necessary accessories as per the site requirement. Valve should have a simple and robust construction offering high reliability and free operation with high intake capacity it should be Non Slam Surge Suppression high flow Combination 3-Stage air valve, including all lead & lifts (Location of Valves as per surge analysis report)
Providing, supplying, Erecting & Commissioning of Surge Protection System Comprising of Bladder Vessel with minimum Volume of 15m3, Pressure rating minimum 12 Bar with shell-SA 516 Gr.70, Elliptic Cap-SA 516 Gr.70, Coating inside & Outside – Thk 110 mm along with sand blasting SA 2.5 with Butyl Bladder in vertical position, Vessel Connection size 400mm and connecting Pipe Size 300mm dia. M.S. 300 mm Isolation Valve (Confirming to DIN 3352/BS 5163), Load cell arrangement, necessary piping, Flanges, Fasteners, complete including all lead & lifts. (Location of Bladder Vessel as per Surge analysis report)
saisanket enterprises
Rachana Construction Limited
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .