| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹47.1 L+₹4.6 L (10.8%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹49.1 L+₹6.6 L (15.6%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹49.4 L+₹6.9 L (16.3%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹49.5 L+₹7.0 L (16.6%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jul 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR TO TOILETS SUNKEN FLOOR RAIN WATER PIPES AND OTHER CONNECTED BR WORKS IN ZONE A AREA INCLUDING REPAIR REPLACEMENT OF UG CABLES LT SWITCHGEARS JOINT KITS CABLES AND OTHER CONNECTED WORKS AT ZONE B AREA AT GMS UNDER GE I GOS
2021_MES_448515_1
8000/50/21-22/0949/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹80,000
Yes
9 Aug 2021
4 Jun 2021
14 Jul 2021
4 Jun 2021
12 Jul 2021
21 Jun 2021
Amount
Taking down rain water pipe of any size or pattern incl all fittings head,shoe,band,swan neck etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 75 mm bore of pipe etc complete all as specified and directed.
S&F PVC stack clamps to walls or roof for 100 mm bore of pipe etc complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed.
M&L for removing demolished material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed.
M&L for Cleaning the concerned RCC surface by means of wire brush to expose the concrete surface which should be free from all loose particles, dust, laitance, etc complete all as specified and directed.
M&L for Making corner fillets with Polymer modified cementitious (PMC) mortar (PMC:C:M :: 1:2:4 by weight) at all joints of horizontal and vertical surface and doing bore packing with PMC mortar complete all as specified and directed.
M&L for the joints of pipes and concrete/masonry are to be sealed with epoxy putty or epoxy mortar (PMC:C :: 1:2 by weight) and the same is semi-rounded upto 5mm above surface level all along the periphery of PVC pipes complete all as specified and directed.
M&L for application of one coat of Acrylic Polymer Modified Cementitious (APMC) slurry (APMC:C :: 1:2 by weight) coating over the RCC slab surface and carried upto finished floor level on vertical portion (walls) complete all as specified and directed. (Note : This coat is allowed to get dry for 4-6 hours.)
M&L for application of one coat of Acrylic Polymer Modified Cementitious topping rendering (APMC:C:M :: 1:2:2) 1-1.5mm thick over the first coat Acrylic Polymer Modified Cementitious complete all as specified and directed. (Note : This coat is cured for 48 hours.)
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface, finishing even and smooth using extra cement incl Integral Waterproofing Compound (0.2 % or 100 ml per bag of cement) complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded brick coarse aggregate as in sunken floors etc complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on newly prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coat of white wash complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of cement based paint complete all as specified and directed.
M&L for preparation of old decorated wooden painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer including, rubbing with sand paper complete all as specified and directed.
M & L for preparation of old painted surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
M&L for preparation of old painted surfaces of wall and applying one coat of acrylic exterior weather proof emulsion paint complete all as specified and directed.
Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in loose/soft soil complete all as speified and directed.
Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cm each layer complete all as speified and directed.
Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as speified and directed.
Supply and laying double wall corrugated HDPE pipe 50mm outer dia for protection of UG cable complete all as speified and directed.
Supply and laying double wall corrugated HDPE pipe 80mm outer dia for protection of UG cable complete all as specified
Supply and laying double wall corrugated HDPE pipe 100 mm outer dia for protection of UG cable complete all as speified and directed.
M&L for PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for filling of pole and stay complete all as speified and directed.
M&L for PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole and stay complete all as speified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as speified and directed.
M & L for 50 mm bore tubing light grade galvanised with all fittings laid along the pole/in trenches / under road or floor including removing the rusted old one complete all as specified and directed.
M & L for 80 mm bore tubing light grade galvanised with all fittings laid along the pole/in trenches / under road including removing the rusted old one complete all as specified and directed.
M & L for 100 mm bore tubing light grade galvanised with all fittings laid along the pole/in trenches / under road or floor including removing the rusted old one complete all as specified and directed.
Taking out old unserviceable PCC/steel tubular pole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete all as speified and directed.
Taing out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint complete all as speified and directed.
S & F in replacement of Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat of paint incl taking down the old unserviceable cross arms complete all as speified and directed.
S&F in replacement of insulator pin type porcelain vitereous , white brown or green insulator including one galvanised mild steel spindle, two galvinised washer and one GI nut 100 mm height and 65 mm dia for 1100 Volt grade complete all as speified and directed.
S&F in replacement of insulator shackle type, porcelain, vitereous, white brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washer and nuts for working pressure 1100 Volts height 100mm, dia 115mm, section of strap (31x5) mm dia of bolt 14 mm complete all as speified and directed.
M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down complete all as speified and directed.
S&F in replacement of loop type insulator vitreous white,brown or green insulator small size,with over all dimensions 65 x 90 mm,clearance of hole 16 mm complete all as speified and directed.
Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete all as speified and directed:- (a) 10 Sqmm 2 Core
All as per Item No.64 above but 16 Sqmm 2 Core.
All as per Item No.64 above but 16 Sqmm 4 Core.
All as per Item No.64 above but 25 Sqmm 3.5 Core.
All as per Item No.64 above but 35 Sqmm 3.5 Core
All as per Item No.64 above but 50 Sqmm 3.5 Core
All as per Item No.64 above but 70 Sqmm 3.5 Core
All as per Item No.64 above but 95 Sqmm 3.5 Core
All as per Item No.64 above but 120 Sqmm 3.5 Core
All as per Item No.64 above but 150 Sqmm 3.5 Core
All as per Item No.64 above but 185 Sqmm 3.5 Core
All as per Item No.64 above but 240 Sqmm 3.5 Core
M&L for replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 100/63Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 in incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 In incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 in incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 315 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 in incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of moulded case circuit breaker Four pole 400 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 in incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital voltmeter 0 to 500 volts 96 x 96mm flush type in LT Panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing of LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete all as specified and directed.
Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete all as specified and directed.
M&L for painting steel tubular pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
M&L for painting PCC pole 9 mtrs long alongwith bends with two coats of weather proof paint and two coats of black bituminous paint over a coat and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE. 2. While painting of the panels protection of MCCB's and MCB's to be taken care of by the contractor. Any damage occured during the painting will be bear by the contractor.
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 25-50 sqmm complete all as specified and directed.
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete all as specified and directed.
S&F of Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm complete all as specified and directed.
Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply and fixing Aluminium tube terminal/ lugs of undermentioned size complete all as specified and directed. (a) 10 to 25 Sqmm
All as per Item No. 95 above but 35 to 50 Sqmm
All as per Item No. 95 above but 70 to 120 Sqmm
All as per Item No. 95 above but 150 to 185 Sqmm
Supply only PVC Electrical insulation self adhesive tape 1.8cmx7mx0.125mm for Red, Yellow, Blue & Green complete all as specified and directed.
Supply, fabricate, erect, test and commission in replacement outdoor LT SMC Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.15 mm thick MS sheet, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etc as required with and including the following, supplied fitted and connected internally complete 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators complete all as specified and directed.
S & F in replacement of old UNSV. Cable loop box with SMC Junction box shock and rust proof , rot/termite resistance, tamper proof, with necessary pole mounting arrangements FR type ( (270mm x 225mm x 135mm) with in-built /housed terminal for 04 pole wire termination and 6AMCB din-rail mounted , hinged door with locking arrangements incl necessary Galvanised iron clamps, bolts/nuts suitable to hold/accommodate to the exisitng pole(any type)/ bldg etc by removing the exisiting electrical connections and reconnecting back the same cable complete all as specified and directed. (Note : any glands/lugs/lock-pads reqd for the same is within the the rates quoted)
S&F PVC line spacer of superior quality of 2/3 way spiral type complete all as specified and directed.
S&F PVC line spacer of superior quality of 4 way spiral type complete all as specified and directed.
S&F PVC line spacer of superior quality of 5 way spiral type complete all as specified and directed.
MM ENGINEERING SYSTEMS
M/s TECH TEAM
V.Venkata Ramaiah
M/S K MURALIDHARA PATRA
M/s BLUE WHEEL AGENCIES
M/s Bapujee Builders and Traders
Likitha Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .