Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
2 Jun 2022, 2:00 pmClosed
Executive Engineer MHCHD, Srinagar
Office of the Executive Engineer, MHCHD, Srinagar
SITC of Manifold System along with operation, transportation of filled/empty Bulk Oxygen Cylinders along with refilling of Oxygen Cylinders for PHC Phalgam/PHC Sonamarg, Baltal/ Chandanwari and Base Camp Lower holy Cave/ Upper holyCave/Panchtarni/ Sh
2022_PWDJK_171202_1
MHCHD/TS /2022-23/34/e-tendering Dt28-05-2022
Open Tender
Miscellaneous Works
Item Wise
5 days
Yatra routes of Phalgam and Sonamarg
As Detailed in NIT
4 documents required · 4 mandatory
₹1,000
Executive Engineer MHCHD, Srinagar
₹40,000
Yes
9 Jun 2022
28 May 2022
2 Jun 2022
28 May 2022
2 Jun 2022
28 May 2022
Amount
Part A Manifold System at PHC Sonamarg
SITC of manual oxygen control panel with alarm made of powder coated SS contining pressure regulators,one line regulator and ahigh pressure gauge.The job includes providing and fitting of oxygen cylinder manifold battery bank with support and copper tailpiece along with NRVS for twin battery of 5x5 cylinder on each side.The job includes providing and fitting of seamless copper tubing of 15 mm dia length 3 meters for connecting the panel to pipeline.Allied jobs like cutting of copper pipe,silver brazing ,polishing,copper fittings,supporting piping/tubing using saddles,testing at a double pressure ,painting of the same using standard colours.The job also includes p/f of 15 mm dia isolation valve of cim /leader make on both sides oxygen control panel.The manifold shall be able to withstand the working pressure of 200 PSI.
Providing and Fitting of 5x5Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
12 mm dia
Part B Manifold System at PHC Pahalgam
SITC of manual oxygen control panel with alarm made of powder coated SS contining pressure regulators,one line regulator and ahigh pressure gauge.The job includes providing and fitting of oxygen cylinder manifold battery bank with support and copper tailpiece along with NRVS for twin battery of 5x5 cylinder on each side.The job includes providing and fitting of seamless copper tubing of 15 mm dia length 3 meters for connecting the panel to pipeline.Allied jobs like cutting of copper pipe,silver brazing ,polishing,copper fittings,supporting piping/tubing using saddles,testing at a double pressure ,painting of the same using standard colours.The job also includes p/f of 15 mm dia isolation valve of cim /leader make on both sides oxygen control panel.The manifold shall be able to withstand the working pressure of 200 PSI.
Providing and Fitting of 5x5Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
12 mm dia
Part C Baltal
Providing and Fitting of 3x3Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part D Chandanwari
Providing and Fitting of 3x3Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part E Base Camp Lower Cave
Providing and Fitting of 2x2Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part F Base Camp Upper Cave
Providing and Fitting of 2x2Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part G Panchtarni
Providing and Fitting of 3x3Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part H Sheeshnag
Providing and Fitting of 3x3Manifold battery for connecting the oxygen Cylinders of 7 Cum capacity along with copper tail pipes fitted with valves. The Job shall include fitting the Manifold on the wall as shall be identified at site.
Providing,Fitting& testing of seamless copper tubing, solid drawn of thickness 0.9mm for oxygen line.The copper tubing shall be seamless hard tempered suitable for medical grade. The job includes cutting of copper tubing, silver brazing, polishing etc. Providing and fitting of copper fittings like nipples, sockets, elbows, reducers, tees etc.The copper tubing shall be fitted on the wall with the help of saddles, clamps etc and shall have to be tested at a pressure 3 times than the working pressure of oxygen.The tubing shall be applied with 2 coats of paint as per standard colour code.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow, with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings ,probe complete in all respects.
Providing, fitting and testing of Oxygen self sealing valve assembly (front loaded double locking) including cover for oxygen supply .The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The job further includes providind and fitting of suitable probe at the front end of the existing Oxygen pipe line.The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas color coded.
Providing and fitting of brass metal ball type isolation valve.The job includes fitting of the valve on the pipeline by means of brazing with silver electrode alongwith necessary fittings required to complete the job.
15 mm dia
Structural Steel of ISA/ISMC of required size work for making a holding of copper pipe and support for self sealing outlets, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
Part I Operation of Manifold System and Transportation of filled, empty Bulk Oxygen Cylinders
Operation of Manifold Systems at lower cave, upper cave, Sheshnag, Panchtarni by way of providing of additional 04 Semi Skilled Persons for a period of 45 days. The providing of additional manpower in these facilities shall work with the staff who is on roll of MHCHD but presently working in various hospitals of DHSK.
Transportation of Bulk Oxygen Cylinders in Mechanical Transport for refilling from Ganderbal/Bijbehara to filling stations at Khunmoh/ Rangret and Vice versa.
Transportation of Filled Bulk Oxygen Cylinders in mechanical transport from Bijbehara to Chandanwari and vice versa with empty cylinders.
Transportation of Filled Bulk Oxygen Cylinders in mechanical transport from Ganderbal to Baltal and vice versa for empty cylinders.
Transportation of filled Oxygen Cylinders by ponies from Chandanwari to Sheshnag/Panchtarni and cave and vice versa for empty cylinders.
Transportation of filled Oxygen Cylinders by ponies from Baltal to Panchtarni and Cave and vice versa for empty cylinders.
Part J Refilling charges of Bulk, Medium Oxygen Cylinders
Refilling charges of Medical Oxygen to Bulk Cylinders of 7 Cum Capacity at 140 Kgf/cm2
Refilling charges of Medical Oxygen to Medium Cylinders at 140 Kgf/cm2
NIGHTINGALE TRADING ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .