Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-Finance | L1 | Accepted-Finance Lowest rate | |
| 2 | L2₹18.8 L+₹3,711.27 (0.20%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L2 | Rejected-Finance higher rate | |
| 3 | L3₹21.3 L+₹2.4 L (13.0%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L3 | Rejected-Finance highest rate |
| Sl No | Description | Qty | Unit | ORIENTAL ENGINEERING CO. L3 | WEST BENGAL ENGINEERING CO. L2 | JDJ ENTERPRISE. A UNIT OF JDJ TRADERS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00 | Procurement, transportation, and safe handling at site of 3-pole Air Circuit Breaker (ACB), EDO type with LSIG protection, 2000 A rated current (In), 600 V rated voltage (Ur), and 50 kA short-circuit breaking capacity (Ics), 12 KV rated impulse withstand voltage (Uimp), 1000 V rated insulation voltage (Ui), fitted with shunt opening coil -YO-220~240 V AC, shunt closing coil -YC-220~240 V AC, spring charging motor 220~240 V AC, trip indication, micro switch including standard accessories and documentation as per manufacturer’s practice.
[Make- ABB / any equivalent Dept. approved] | 2 | nos | 7,98,700 ₹15,97,400 | 6,98,000 ₹13,96,000 | 6,97,018 ₹13,94,036 Lowest |
| 2.00 | Installation, retrofitting, and commissioning of the above newly supplied Air Circuit Breaker [ref. sl.no. 1.00], including disconnection and removal of the existing damaged ACB and its base from the LT PDB Panel in the Electrical Substation (location - 1) and the MCC Panel in the Clear Water Pump House (location - 2), disconnection of incoming/outgoing bus-bar terminals and control/power wiring; carrying out necessary retrofitting works; reconnection of bus-bar terminals and control/power wiring to the new ACB base; fitting of the new ACB; supply of all required retrofitting materials; and final testing, including manual/electrical ON–OFF operation checks and manual/electrical spring-charging operation checks, all to be executed by highly skilled technicians to the complete satisfaction of the EIC. | 2 | item | 93,200 ₹1,86,400 | 92,700 ₹1,85,400 | 92,125 ₹1,84,250 Lowest |
| 3.00 | Add: GST @ 18% | 1 | item | 3,21,084 ₹3,21,084 | 2,84,652 ₹2,84,652 | 2,84,091.48 ₹2,84,091.48 Lowest |
| 4.00 | Add: LWC @ 1% | 1 | item | 21,048.84 ₹21,048.84 | 18,660.52 ₹18,660.52 | 18,623.78 ₹18,623.78 Lowest |
Tender Value
Refer Docs
EMD Value
₹38,800
Closing Date
25 Sept 2026, 5:00 pmClosed
Executive Engineer Eastern Mechanical Division P.
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG kol 73
Replacement of existing damaged ACB with new 2000 A, 600 V, 50 kA ACB, including Supply, Retrofitting, and Commissioning at WTP under Surface Water Based Water Supply Scheme for Arsenic Affected Area, Southern Sector, Haringhata in the Dist. of Nadia
2026_PHED_5023152_2
WBPHED/EE/EMD/NIET-07/2026-27
Open Tender
MECHANICAL
Item Rate
60 days
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG
Please refer Tender documents.
6 documents required · 6 mandatory
₹38,800
29 Sept 2026
10 Sept 2026
28 Sept 2026
10 Sept 2026
25 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Procurement, transportation, and safe handling at site of 3-pole Air Circuit Breaker (ACB), EDO type with LSIG protection, 2000 A rated current (In), 600 V rated voltage (Ur), and 50 kA short-circuit breaking capacity (Ics), 12 KV rated impulse withstand voltage (Uimp), 1000 V rated insulation voltage (Ui), fitted with shunt opening coil -YO-220~240 V AC, shunt closing coil -YC-220~240 V AC, spring charging motor 220~240 V AC, trip indication, micro switch including standard accessories and documentation as per manufacturer’s practice.
[Make- ABB / any equivalent Dept. approved] | 2 | nos | - | - |
| 2 | Installation, retrofitting, and commissioning of the above newly supplied Air Circuit Breaker [ref. sl.no. 1.00], including disconnection and removal of the existing damaged ACB and its base from the LT PDB Panel in the Electrical Substation (location - 1) and the MCC Panel in the Clear Water Pump House (location - 2), disconnection of incoming/outgoing bus-bar terminals and control/power wiring; carrying out necessary retrofitting works; reconnection of bus-bar terminals and control/power wiring to the new ACB base; fitting of the new ACB; supply of all required retrofitting materials; and final testing, including manual/electrical ON–OFF operation checks and manual/electrical spring-charging operation checks, all to be executed by highly skilled technicians to the complete satisfaction of the EIC. | 2 | item | - | - |
| 3 | Add: GST @ 18% | 1 | item | - | - |
| 4 | Add: LWC @ 1% | 1 | item | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
Tendernotice_2.pdf
PDF • 1.65 MB
Tendernotice_3.pdf
PDF • 2.33 MB
Tendernotice_4.pdf
PDF • 0.86 MB
BOQ_5106611.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .