| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | ₹29.6 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical documents not in order |
| Sl No | Description | Qty | Unit | MD ABDUL WAHID L1 |
|---|---|---|---|---|
| 1.00 | NS Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes-PE 100) confirming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine.(50 mm & above fusion jointed & below 50mm mechanical jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code.
(a) 110 mm dia HDPE PN 6 | 400 | RM | 636 ₹2.5 L |
| 2.00 | NS Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes-PE 100) confirming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine.(50 mm & above fusion jointed & below 50mm mechanical jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code.
(b) 90 mm dia HDPE PN 6 | 1,000 | RM | 451 ₹4.5 L |
| 3.00 | NS Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes-PE 100) confirming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine.(50 mm & above fusion jointed & below 50mm mechanical jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code.
(c) 75 mm dia HDPE PN 6 | 2,350 | RM | 372 ₹8.7 L |
| 4.00 | NS Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes-PE 100) confirming to IS 4984/2016 (with up to date amendment) with necessary jointing material like mechanical connector of jointing pipes by heating the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine.(50 mm & above fusion jointed & below 50mm mechanical jointed). The HDPE fitting should be ISI marked conforming to relevant BIS code.
(d) 63 mm dia HDPE PN 6 | 1,717 | RM | 316 ₹5.4 L |
| 5.00 | NS Supplying,fitting,fixing,testing and commissioning of Functional Household Tap Connection at various PWSS under different divisions of the state | 178 | Each | 2,976 ₹5.3 L |
| 6.00 | 458 11 KV 1C X 50 SQMM AAAC Covered Conductor | 650 | RM | 338.5 ₹2.2 L |
| 7.00 | 18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):
18.34.1 100 mm dia | 4 | Nos. | 4,097.9 ₹16,391.60 |
| 8.00 | 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:
18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 | 4 | Nos. | 17,578.1 ₹70,312.40 |
Tender Value
₹30.0 L
EMD Value
₹60,075
Closing Date
9 Sept 2025, 4:00 pmClosed
Superintending Engineer PHE Guwahati Circle
O/o Superintending Engineer (PHE), Guwahati Circle, amunimaidan, Guwahati-781021
Utility shifting and repairing of (Water distribution pipeline of PWSS) damaged during PWD road widening for Borgaon PWSS under Rangia (PHE) Division under SOPD-G for the year 2025-26
2025_PHED_46302_1
SEPH/GC/TB-152/Vol-XXI/25-26
Open Tender
Civil Works
Borgaon Village
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
₹60,075
Yes
O/o Superintending Engineer (PHE), Guwahati Circle
21 May 2026
12 Aug 2025
10 Sept 2025
12 Aug 2025
9 Sept 2025
19 Aug 2025
19 Aug 2025
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf