Loading…
Loading…
Tender Value
₹10.2 L
EMD Value
₹20,360
Closing Date
31 Aug 2026, 2:00 pm7d left
Estate Manager
O/o EMU (R and D), DRDO Complex, Near Airport, Jagdalpur - 494001.
Maintenance of gasket, breather, HT or LT bushing, oil filtration and BDV test for various power and distribution transformers at site-G, SF Complex, Jagdalpur.
2026_DRDO_921436_1
EMU/JPR/ENQ/EM/BDV/34/2026-27
Open Tender
Electrical Works
Item Rate
365 days
Jagdalpur
Please refer tender documents.
7 documents required · 7 mandatory
₹0
₹20,360
10 Aug 2026
10 Aug 2026
1 Sept 2026
10 Aug 2026
31 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 33/11 Kv, 3000 KVA ONAN outdoor transformer: -
Volts HV - 33000, Volts LV - 11000
Line Amps HV - 52.48, Line Amps LV - 157.46
Make : Alsthom.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container).
(a) 33 KV Current Transformer - 12
(b) 33 KV Potential Transformer - 03
(c) 11 KV Current Transformer - 09
(d) 11 KV Potential Transformer - 09
ON Load Tap Changer of 33/11 Kv Transformer (03 Nos): -.
Volts HV - 33000, Volts LV - 11000
Line Amps HV - 52.48, Line Amps LV - 157.46
Make : Alsthom.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 2 | 11KV / 433, ONAN, 2000 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Kirloskar.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 3 | 11KV/ 433, ONAN 1000 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Alsthom.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 4 | 11KV/433, ONAN, 750 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Alsthom.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 5 | 11KV/433, 500 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Kirloskar.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 6 | 11KV/433, 315 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Alsthom.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 7 | 11KV/433, 100 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Essennar.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 8 | 11KV/433, 160 KVA Transformer: -
Volts HV - 11000, Volts LV - 433
Make : Kirloskar.
(i) Filteration of transformer oil along with BDV test with supply and replacement of transformer oil, Gasket, Silica Gel, repairing of LT, HT bushing, Diaphragm, Buchholz Relay, Conservator & Tap Changer.
(ii) Conduct BDV test of top & bottom, sample of transformer oil, before & after filteration and report submission.
(iii) Supply, filter & topup of transformer oil / power oil.
(Mentioned transformer oil should be delivered at site in sealed container). | - | Ltrs | - | - |
| 9 | 11KV/433, 400 KVA Transformer. Location -Substation - 11. | - | Ltrs | - | - |
| 10 | 11KV/433, 200 KVA Transformer. Location -Substation - Nursery pump house. | - | Ltrs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Enquiry.pdf
Tender Documents • 0.20 MB
ANNEXURE-IXBG_FORMAT.pdf
Tender Documents • 0.11 MB
ANNEXURE-VISimilarWorks.pdf
Tender Documents • 0.10 MB
ANNEXURE-VIICompletionPerformance.pdf
Tender Documents • 0.05 MB
ANNEXURE-VIIIAnnualTurnover.pdf
Tender Documents • 0.05 MB
ANNEXURE-XBannedBusiness.pdf
Tender Documents • 0.08 MB
GCC_2023.pdf
Additional Documents • 1.16 MB
FORM-ABiddingCapacity.pdf
Tender Documents • 0.36 MB
BOQ_968313.xls
BOQ • 0.29 MB
ANNEXURE-VUndertaking.pdf
Tender Documents • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].