| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 CrAdmitted-Finance | ₹25.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹27.9 CrAdmitted-Finance | ₹27.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹28.1 CrAdmitted-Finance | ₹28.1 Cr | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Jainco Buildcon Private Limited L1 | TIRUPATI CEMENT PRODUCTS L2 | M/s PARVEEN KUMAR JAIN L3 |
|---|---|---|---|---|---|---|
| 1.00Installation of Tubewells for Augmentation of water supply through extraction of ground water, construction of tube wells rooms and laying water lines network in WTP complex Bawana under EE(Project)W-VII/EE(E&M)-II. | ||||||
| 1.01 | S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 20 HP, Discharge - 1400 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 3 nos. tube well + 1 nos. p/set standby) | 3 | Nos | - | - | - |
| 1.02 | S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 30 HP, Discharge - 1650 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 6 nos. tube well + 3 nos. p/set standby) | 4 | Nos | - | - | - |
| 1.03 | S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 40 HP, Discharge - 1900 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 6 nos. tube well + 3 nos. p/set stand by) | 3 | Nos | - | - | - |
| 1.04 | S/o submersible cable with copper conductor having three core sizes 6 sq. mm working on 1100V. 1 roll = 100 mtr. Make:-Finolex/Plaza/Unistar or any other make approved by DJB. | 5 | Nos | - | - | - |
| 1.05 | S/o submersible cable with copper conductor having three core sizes 10 sq. mm working on 1100V. 1 roll = 100 mtr. Make:-Finolex/Plaza/Unistar or any other make approved by DJB. | 2 | Nos | - | - | - |
| 1.06 | Making and supply of MS clamp of 700 mm long x 75 width x 12 mm thick complete with nut and bolts and washers for holding the 100/150 mm dia pipe including bending and shaping etc. as required. | 7 | Nos | - | - | - |
| 1.07 | S/o NRV 100 mm dia CI double flanges PN1.0 Make:-Kirloskar /IVC or any other make approved by DJB. | 5 | Nos | - | - | - |
| 1.08 | S/o NRV 150 mm dia CI double flanges PN1.0 Make:-Kirloskar /IVC or any other make approved by DJB. | 2 | Nos | - | - | - |
| 1.09 | S/o CI sluice valve , non rising S.S. spindle, D/F P.N 1.0 of size 100 mm Make:- Kirloskar /IVC or any other make approved by DJB. | 5 | Nos | - | - | - |
Tender Value
₹17.5 Cr
EMD Value
₹35.1 L
Closing Date
25 May 2022, 3:00 pmClosed
EXECUTIVE ENGINEER (C) DR-XII
EXECUTIVE ENGINEER (C) DR-XII MU BLOCK, PITAMPURA, DELHI-110034
Providing/Laying 900 mm dia rising main from Uttam Nagar SPS to Keshopur STP.
2022_DJB_221070_1
NIT No. 02/ EE (C) Dr XII /2022-23(Re-invite)
Open Tender
Miscellaneous Works
180 days
OFFICE OF THE EXECUTIVE ENGINEER (C) DR-XII
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
A/c No. 50448339804 at Allahabad Bank, Copernicus
₹35.1 L
CE(Dr)Proj-III
6 Jun 2022
25 Apr 2022
25 May 2022
25 Apr 2022
25 May 2022
25 Apr 2022
2 May 2022
Amount
Installation of Tubewells for Augmentation of water supply through extraction of ground water, construction of tube wells rooms and laying water lines network in WTP complex Bawana under EE(Project)W-VII/EE(E&M)-II.
S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 20 HP, Discharge - 1400 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 3 nos. tube well + 1 nos. p/set standby)
S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 30 HP, Discharge - 1650 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 6 nos. tube well + 3 nos. p/set standby)
S/O submersible pump set fitted with dynamically balanced SS impeller mounted on stainless steel shaft protective sleeves. The pump set directly coupled with submersible motor having normal speed of 2900 RPM, 50 HZ, Three phase, 415 Volt, A.C supply having specification :- HP- 40 HP, Discharge - 1900 LPM, Head - 50 mtr. Make : BS/KSB/SU/Approved make in DJB ( 6 nos. tube well + 3 nos. p/set stand by)
S/o submersible cable with copper conductor having three core sizes 6 sq. mm working on 1100V. 1 roll = 100 mtr. Make:-Finolex/Plaza/Unistar or any other make approved by DJB.
S/o submersible cable with copper conductor having three core sizes 10 sq. mm working on 1100V. 1 roll = 100 mtr. Make:-Finolex/Plaza/Unistar or any other make approved by DJB.
Making and supply of MS clamp of 700 mm long x 75 width x 12 mm thick complete with nut and bolts and washers for holding the 100/150 mm dia pipe including bending and shaping etc. as required.
S/o NRV 100 mm dia CI double flanges PN1.0 Make:-Kirloskar /IVC or any other make approved by DJB.
S/o NRV 150 mm dia CI double flanges PN1.0 Make:-Kirloskar /IVC or any other make approved by DJB.
S/o CI sluice valve , non rising S.S. spindle, D/F P.N 1.0 of size 100 mm Make:- Kirloskar /IVC or any other make approved by DJB.
S/o CI sluice valve , non rising S.S. spindle, D/F P.N 1.0 of size 150 mm Make:- Kirloskar /IVC or any other make approved by DJB.
S/o GI bend 100 mm dia 90deg. Double flange. Heavy class Make: - Ganesh/ ISI
S/o GI bend 150 mm dia 90deg. Double flange. Heavy class Make: - Ganesh/ ISI
S/o of GI pipe 100 mm diasize ,medium class with GI flange welded in both sides 3 Mtr long with ms strips complete with threading work on each side of pipe each flange should be 4 holes and cut for cables. make :- Jindal / TATA.
S/o of GI pipe 150 mm diasize ,medium class with GI flange welded in both sides 3 Mtr long with ms strips complete with threading work on each side of pipe each flange should be 4 holes and cut for cables. make :- Jindal / TATA.
S/o G.I required off size threaded heavy duty nut-bolts of good quality.
Supply of MS bore cover 4 mm thick suitable for bore size in 2 pieces complete with bolting arrangement angle iron frame and provision of 100/150 mm dia hole in the center.
S/o pressure gauge of 100 mm dia, 0-30 PSI complete with socket, bush Make:-H-Guru/Fiebig
Making and Supply of G.I tail piece of 100 mm dia. , one mtr. Long size made out of medium class pipe complete with one end threaded and other end fitted with G.I. flange heavy and cut for submersible cable. Mak of Pipe - Jindal/Tata.
Making and Supply of G.I tail piece of 150 mm dia. , one mtr. Long size made out of medium class pipe complete with one end threaded and other end fitted with G.I. flange heavy and cut for submersible cable. Mak of Pipe - Jindal/Tata.
Supply, installation, testing and commissioning of RTU with PLC for tube well’s with Radio/ GPRS/ Wifi/LoRa communication compatible to central SCADA. RTU/PLC should by suitable for Harsh environment, Robust & well-designed controller with a long life cycle RTU shall have 3MB internal RAM memory & built-in 4 digital inputs, 4 digital outputs & 4 Analog Inputs, along with 1no USB Port, 1no Serial port (RS232/RS485), having 1 no Ethernet port. Make: Rockwell/Schneider/ Siemens/ ABB/ E&H
Supply, installation, testing and commissioning of AC Drive Module for tube well’s suitable for 20 HP Motor VFD module should have built-in 6 Digital Inputs, 3 Relay Outputs, 3 Analog Inputs and 2 Analog Outputs along with Modbus TCP/IP communication. VFD Should be by default conformal coated 3C3 suitable for harsh environment.VFD should have following features-- AC Drive should have following protections:- Over Current, Under and Over Voltage, Earth Fault in Motor or cable, Motor Stall, Motor Overload & Under load, Short Circuit, Single Phasing Prevention, Motor Unbalance, Under Voltage, Over Voltage, Over temperature- Accurate open loop torque control- 110% overload capacity for 60 second.- The AC Drive should provide a Cavitation’s Pump Protection- AC Drive display on panel door with display features like Motor / Drive parameters, Energy parameters (KWH).The AC Drive should provide a inlet protection in order to avoid system dry running system.
Supply, installation, testing and commissioning of AC Drive Module for tube well’s suitable for 30 HP Motor VFD module should have built-in 6 Digital Inputs, 3 Relay Outputs, 3 Analog Inputs and 2 Analog Outputs along with Modbus TCP/IP communication. VFD Should be by default conformal coated 3C3 suitable for harsh environment. VFD should have following features- - AC Drive should have following protections:- Over Current, Under and Over Voltage, Earth Fault in Motor or cable, Motor Stall, Motor Overload & Under load, Short Circuit, Single Phasing Prevention, Motor Unbalance, Under Voltage, Over Voltage, Over temperature - Accurate open loop torque control - 110% overload capacity for 60 second. - The AC Drive should provide a Cavitation’s Pump Protection - AC Drive display on panel door with display features like Motor / Drive parameters, Energy parameters (KWH). The AC Drive should provide a inlet protection in order to avoid system dry running system.
Supply, installation, testing and commissioning of AC Drive Module for tube well’s suitable for 40 HP Motor VFD module should have built-in 6 Digital Inputs, 3 Relay Outputs, 3 Analog Inputs and 2 Analog Outputs along with Modbus TCP/IP communication. VFD Should be by default conformal coated 3C3 suitable for harsh environment.VFD should have following features-- AC Drive should have following protections:- Over Current, Under and Over Voltage, Earth Fault in Motor or cable, Motor Stall, Motor Overload & Under load, Short Circuit, Single Phasing Prevention, Motor Unbalance, Under Voltage, Over Voltage, Over temperature- Accurate open loop torque control- 110% overload capacity for 60 second.- The AC Drive should provide a Cavitation’s Pump Protection- AC Drive display on panel door with display features like Motor / Drive parameters, Energy parameters (KWH).The AC Drive should provide a inlet protection in order to avoid system dry running system.
Non Redundant UPS for 1 KVA capacity with 1 hour backup with SMF battery for RTU Locations.
Supply, installation, and commissioning of cubical fabricated Panel for RTU and VFD of the tube well’s. The panel shall be supplied with CPRI approved manufactures and Panel need to be IP-54 protection class.
Supply of neoprene rubber sheet having 50% neoprene , 3 mm thick Make Jyoti/Worth/DJB approved
Supply and fixing (Permenaent)of electric insulated sheet for AC & DC which is moisture proof, U.V. protected, fire retardant, high di-electric strength, easy to clean, auto glow path, coloured strips on both sides, glow in emergency, CPRI approved, confirming to BISDOC No. ET-02 (5440). Dt: 30-04-04, meeting requirement of IS:3043, IS:5216 (Part 1,2 & 3), IS: 8437 and IEC: 479 PUB-1 tested for breakdown strength tensile, elongation aging properties, insulation resistance effect of acid, alkaline, diesel and transformer oil, leakage current test etc. Considering 2 mtrs at each tube well. Make: Electromat/Safevolt
Supply, installation, testing and commissioning of level indicator with vented cable for SCADA interface preferably 4-20 mA and with display as site as per site requirement for ground water
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 2018 5.6
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 2018 5.15
Installation of all E&M Equipments, lowering pump set in to the bore all piping work fixing of valves and accessories executing minor civil works, making electrical connections with cable as required size I/C hiring cost of hydra/tripod to lower pump sets as required and making of civil platform made out from bricks, cement etc. upto suitable height required for installation of starter panel; if required and watch and ward cartage, taking all safety measures all tools an tackles testing and commissioning of all E&M equipments at no load and full load conditions as per standard from full satisfaction of Engineer-in-Charge. (10% of Rs. 47,75,900.00 i.e sum of sr. 1 to 19 & 26 = Rs. 477590/15 =31,839.33)
Bidder Name
Amount
Jainco Buildcon Private Limited(GSTN-07AABCJ6852B1ZS)
TIRUPATI CEMENT PRODUCTS(GSTN-07AACFT2702L1Z9)
M/s PARVEEN KUMAR JAIN(GSTN-07AAIPJ3338A1Z5)
TIRUPATI CEMENT PRODUCTS
M/s PARVEEN KUMAR JAIN
TIRUPATI CEMENT PRODUCTS
M/s PARVEEN KUMAR JAIN
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
BOQ_285295.xls
BOQ • 0.33 MB
2.pdf
Tender Documents • 4.48 MB
Download all tender documents and submit your bid