Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹19.3 LAdmitted-Finance ADD HANUMAN MANDIR ROAD KRISHNAPURI CHUTIA DORANDA CHUTIYA RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | -2.55% | ₹19.3 L | L1 | Admitted-Finance |
| 2 | L2₹19.4 LAdmitted-Finance | -2.00% | ₹19.4 L | L2 | Admitted-Finance |
| 3 | L3₹19.8 LAdmitted-Finance MADARSA ROAD SONPURWA DISTRICT GARHWA | +0.00% | ₹19.8 L | L3 | Admitted-Finance |
Tender Value
₹19.8 L
EMD Value
₹40,000
Closing Date
3 Feb 2026, 5:00 pmClosed
EE, RMC
RMC
Restoration of Atal Clinic at Jogo Pahad under Ward No 02
2026_UDD_109905_1
207/ENG 2026
Open Tender
Civil Works
120 days
AS PER NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹40,000
16 May 2026
29 Jan 2026
4 Feb 2026
29 Jan 2026
3 Feb 2026
29 Jan 2026
Labour for cleaning the work site before and after work etc.
Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I.
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. 4mm
Polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking Suitable Locking system in Double layer confriming to ISI 12701-1996 with Latest revision
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 25 mm nominal dia pipes
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of "Hindustan" " Parry" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l. standing corner 600 mm x 300 mm
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l.
FLUSH (b) 10.0 Litres capacity P.V.C. low design cistern (lSl Marked)
LED BULB
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge.
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface toremove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready touse, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." (Product Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°CTensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370. (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured."" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured(e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years."
Covering of treated surface with PCC :-providing 25 mm thick Cement Concrete M20 (1:1:5:3) maintaining slope in alternate 2 mt x 2mt panels With approved quality of stone chips of 20mm to 6 mm size graded and Cleaned sand of F.M.2.5 to 3 including screening, shuttering, and mixing Cement concrete in mixer with admixture of integral water proofing and Placing in position, striking curing, taxes and royalty all complete as per Building specification and direction of E/I. Panels that has been left should Be casted next day. There should be 6 mm gap between panels .brand- Sika _ plastocrate plus, MYK proof WP 10, Fosroc- Conplast X 421 ic Dr Fixit Pidiproof LM+
Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M. including all lifts, levelling, ramming the foundation trenches removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankement site with in all lifts and lead upto 100 m in including rolling , compacting & watering
Drilling BX (41 mm to 59 mm) size dia test and grout holes in all kinds of hard rock including finishing etc till grouting operation is completed as per specification and direction of E/I
Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level PCC 1.2.4
Providing designation 75B brick work in C.M(1:6) in foundation and plinth -do-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering shuttering, finishing and renforcement-all work up to plinth level PCC 1:1.5:3
Reinforced cement concrete work in walls (any Thickness), including attached pilasters, buttresses, abutments, posts and structs etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size)
Providing designation 75B brick work in C.M(1:6) in foundation and plinth -do-
Providing TMT reinforcement of 8mm dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
Providing TMT reinforcement of 10 mm dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
Providing TMT reinforcement of 12 mm dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.
Providing 12mm Thick cement plaster(1:4)-do-do-E/I
Supplying .fitting and fixing MS Grill Made with M.S Grills made of 20 x 60 mm M.S Flats or 16 mm M.S Square bars fitted on 25 x25x6 mm M.S Angle frame-do-(when steel steel is not supplied department)
Providing two coats of synthetic enamel Paint of approved shade and make over steel surface -do-do/E/I
Providing primer one coat of red lead paint of approved make over new steel surface surface including preparing the surface after cleaning removing dust ,dirt,scales smoke and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per specification and direction of E/I
Providing two coats of snowcem of approved shade and make over coat of cement primer on new surface including preparing the plastered surface smooth with sand paper,scaffolding,curing and taxes all complete as per building specification and direction of E/I
Centering and shuttering including strutting,propping, etc and removal of form for foundation, footing, bases of column etc
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (B) From 51 M to 100 M below G.L.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying ,fitting and fixing panel board with MCB Voltmeter and main with starter having stating capacity and running capacity with indicator etc all complete as per specification
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
Granular Sub-Base with Coarse Graded Material (Table:-400-1) :- Construction of granular sub- base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. (For Grading-II Material)
Providing and laying 80mm thick factory made concrete interlocking pavour block of M-40 grade made by block making machine with strong vibratory compaction of approved size, design and shaped, laid in required colour and pattern over bed as per relevant IRC code filling the joints with fine sand etc all complete as per the direction of E/I
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:1.5:3 (1 Cement : 1.5 coarse sand zone(III): 3 graded stone aggregate 20mm nominal size)
Sand (Lead Upto 49 km)
Bricks (Lead 36 KM)
Stone Chips (Lead 22KM)
Earth
Good & Service Tax (GST)
Labour Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
Tendernotice_2.pdf
PDF • 1.73 MB
BOQ_148496.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid